Advertisement for orthosearch.org.uk
Results 1 - 20 of 1857
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1029 - 1033
1 Sep 2001
Jung JM Baek GH Kim JH Lee YH Chung MS

We studied radiographs of the wrists of 120 healthy volunteers in order to determine the normal range of ulnar variance. They had been taken in various positions under both unloaded (static) and loaded (dynamic) conditions. Pronation posteroanterior, supination anteroposterior and neutral posteroanterior views were taken of each wrist before and during a maximum grip under identical conditions. The mean normal ulnar variance in neutral rotation was +0.74 ± 1.46 mm, a value which was significantly lower in males than in females. We found negative variance in 26% of cases. We measured maximum ulnar variance (UV. max,. +1.52 ± 1.56 mm) when gripping in pronation and minimum ulnar variance (UV. min,. +0.19 ± 1.43 mm) when relaxed in supination. We subtracted UV. min. from UV. max. to calculate a mean maximum dynamic change in ulnar variance of 1.34 ± 0.53 mm. We consider this database of normal values to be useful for both the diagnosis and treatment of conditions related to discrepancy in radio-ulnar length and for clinical research


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 94 - 94
1 Mar 2009
Owers K Scougall P Dabirrahmani D Wernecke G Jhamb A Walsh W
Full Access

Negative ulnar variance, lunate shape and increased load transmission are associated with Kienbock’s disease. This may reflect trabecular alignment being more susceptible to shear forces along “fault planes” in Type 1 lunates, causing microfractures and avascular necrosis. The aim of this study was to assess the relationship between lunate bone structure, density and ulnar variance. Standard 90/90 radiographs of 22 cadaveric wrists were taken for ulnar variance and lunate shape. The lunates were harvested and routine CT scans (1mm) were taken in 22/22 in the coronal, sagittal and transverse planes. DICOM files were analysed using Mimics (Materialise, Belgium) to measure Hounsfield units. MicroCT scans (SkyScan, Belgium) (40 μm) were taken in 10/22 in the coronal plane and measured for trabecular angle at the proximal and distal joint surfaces and the ‘tilting angle’ (between scaphoid and radius joint surfaces). Data was anlaysed using one-way ANOVA tests using SPSS for Windows. Negative ulnar variance was noted in 7/22, neutral 10/22 and positive 5/22. Lunate shape according to Zapico was 0/22 Type 1, 18/22 Type 2 and 4/22 Type 3. Lunate bone density was significantly lower in the ulnar positive specimens compared to ulnar negative and neutral (p< 0.001) (fig. 1). The average trabecular angle measured 84.7° (+/− 4.5°) at the proximal and 90.3° (+/− 2.6°) at the distal joint surfaces and tilting angle was 115.7° (+/− 12.0°) (fig. 2). The 50% slice on the microCT correlated best with xray measurements of this angle. This study quantifies the previous finding that load transmission through the lunate and hence lunate bone density is related to ulnar variance and that this is higher in ulnar negative wrists. MicroCT is a useful modality to assess trabecular structure and supports the ‘fault plane’ hypothesis of Kienbock’s Disease


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 359 - 360
1 Mar 2004
Mayr E Kessler O Moctezuma J Krismer M Nogler M
Full Access

Aims: For planning of Total Hip Arthroplasties (THA) plain X-rays of the pelvis in anterior posterior orientation are used. New methods such as CT scans and intraoperative digitization with navigation devices introduce the third dimension into orthopaedic planning. In order to compare measurements derived from three-dimensional data-acquisition with standard pelvic measurements it is important to estimate the underlying variances of those standards. Methods: 120 patients were investigated and subdivided in 4 groups depending of their age or the condition of their hip joints. The patients were positioned in a supine position on a table and in a standing position. Three landmarks at the patientñs pelvis (left and right anterior superior iliac spine (ASIS) and the pubic tubercle (PT)) were percutaneously digitized with a digitizing arm (Micro-Scribe-3DX, Vizion, Glendale, CA). The pelvic positions in space were calculated in relation to the horizontal and the vertical plane. Results: Despite the anatomical deþnition (0¡), we found an inclination of 4-6¡. There is no signiþcant difference between supine and standing position and no signiþcant difference between the groups and no diffenrence between genders. All patients lyed ßat in supine position without special positioning effort Conclusions: The pelvis orientation ist very stable in standing as well in supine position no matter if the patient is old or young, has coxarthrosis ore none or a THA. Therefore it can be concluded that our knowledge derived from measurements of planar a.-p.x-rays is not inßuenced by a massive variance in pelvic positions


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 299 - 300
1 Nov 2002
Kligman M Sprecher E Roffman M Yarnitsky D
Full Access

Background: Quantitative sensory testing (QST) conventionally identifies threshold elevation as reflecting sensory deficit. A major disadvantage of the technique is its inability to distinguish organic from feigned sensory deficit, as both are characterized by an elevated threshold. Aim: To distinguish organic from feigned sensory deficit. Method: Vibratory thresholds and their variances were measured, at foot L4, L5 and S1 sites, in 14 patients with low back pain (LBP) suspected of non-organic sensory loss by clinical criteria of Waddell, 14 patient controls with abnormal neurological examination and CT of the low back, and 20 healthy controls. Results: Thresholds of non-organic patients and of patient controls were elevated to a similar extent compared to those of healthy controls. Variances, however, were higher for non-organic patients (6.7–10.5 for the various test sites) than for either patient controls (0.39–0.80, p: 0.001–0.05) or for healthy controls (0.20–0.54, p: 0.001–0.02). Of non-organic patients with high thresholds who would otherwise be identified as pathological, 30–67% were ‘spared’ the misdiagnosis and correctly identified as non-organic because of the inclusion of the variance criterion. Conclusion: Variance evaluation is therefore suggested for inclusion into QST methodology, together with threshold itself, as a quality assurance parameter


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 38 - 38
1 Jul 2020
Lalone E Suh N Perrin M Badre A
Full Access

Distal radius fractures are the most common upper extremity injury, and are increasingly being treated surgically with pre-contoured volar-locking plates. These plates are favored for their low-profile template while allowing for rigid anatomic fixation of distal radius fractures. The geometry of the distal radius is extremely complex, and little evidence within the medical literature suggests that current implant designs are anatomically accurate. The main objective of this study is to determine if anatomic alignment of the distal radii corresponds accurately with modern volar-locking plate designs. Additionally, this study will examine sex-linked differences in morphology of the distal radius.

Segmented CT models of ten female cadaver (mean age, 88.7 ± 4.57 years, range, 82 – 97) arms, and ten male cadaver (mean age, 86 ± 3.59 years, range, 81 – 91) arms were created. Micro CT models were obtained for the DePuy Synthes 2.4mm Extra-articular (EA) Volar Distal Radius Plate (4-hole and 5-hole head), and 2.4mm LCP Volar Column (VC) Distal Radius Plate (8-hole and 9-hole head). Plates were placed onto the distal radii models in a 3D visualization software by a fellowship-trained orthopaedic hand surgeon. The percent contact, volar cortical angle (VCA), border and overlap of the watershed line (WSL) were measured.

Both sexes showed an increase in the average VCA measure from medial to lateral columns which was statistically significant. Female VCA ranged from 28 – 36 degrees, and 38 – 45 degrees for males. WSL overlap ranged from 0 – 34.7629% for all specimens without any statistical significance. The average border distance for females was 2.58571 mm, compared to 3.52411 mm for males, with EA plates having a larger border than VC plates. The border distances had statistically significant differences between the plate types, and was approaching significance between sexes. Lastly, a maximum percent contact of 21.966 % was observed in specimen F4 at a 0.3 mm threshold. No statistical significance between plate or sex populations was observed.

This study investigated the incoherency between the volar cortical angle of the distal radius, and the pre-contoured angle of volar locking plates. It was hypothesized that if the VCA measures between plate and bone were unequal then there would be an increase in watershed line overlap, and decrease in percent contact between the surfaces. Our results agreed with literature, indicating that the VCA of bone was larger than that of the EA and VC pre-contoured plates examined in this study.

With distal radius fracture incidences and prevalence on the rise for elderly female patients, it is a necessity that volar locking plates be re-designed to factor in anatomical features of individual patients with a particular focus on sex differences. New designs should focus on providing smaller head sizes that are more accurately tailored to the natural contours of the volar distal radius. It is recommended that future studies incorporate expertise from multiple surgeons to diversify and further understand plate placement strategies.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 278 - 278
1 Nov 2002
Parkinson S Hooper G
Full Access

Hypotheses:

A subject’s response to commonly used knee assessment scores is variable, even in the presence of a normal knee.

The subjective response to a knee score is dependent on age and cultural expectations.

Methods: A group of 150 New Zealand subjects with normal knees were given three commonly used knee assessment questionnaires. There were three age groups with 50 subjects in each group: 20 to 40, 40 to 60 and above 60 years of age. All were examined to determine that each knee was objectively normal. This group was then compared with a similar group of Canadian subjects and the results were analysed.

Results: The results showed significant differences in expectation between the age groups, with the older age group less happy to score maximum points for their ‘normal’ knee. The Hospital for Special Surgery Knee Score scored the lowest followed by the Knee Society Knee Score. In the over 60 years group there was a significant difference between the New Zealand and Canadian subjects with the Canadians tending to score higher in all scores.

Conclusions: These results have implications when trying to compare results of total knee arthroplasty between different countries and age groups. This study has been expanded to include other countries in an attempt to find a mathematical formula to make future comparisons more relevant.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 76
1 Mar 2002
Hooper G
Full Access

A patient’s response to knee assessment questionnaires is often subjective and linked to age and cultural expectations.

In New Zealand 150 people, split into three groups of ages 20 to 40 years, 40 to 60 years and over 60 years, were given three commonly used knee assessment questionnaires. All were examined objectively to determine that their knees were normal. Scores in these groups were compared to similar groups of Canadian subjects and the results analysed.

The results show significant differences in expectations between the age groups. Older people were reluctant to score maximum points for their normal knees. The Hospital for Special Surgery’s knee score gave the lowest results, followed by the Knee Society score. In the over-60-year group there was a significant difference between scores in New Zealand and Canada, with Canadians tending to score higher in all scores.

These findings have implications when it comes to comparing results of total knee arthroplasty in different countries and age groups. This study has been expanded to include other countries in an attempt to find a mathematical formula that will make future comparisons more relevant.


Objectives/background: Flexion Stability and Patella tracking after Total Knee Replacement is mainly influenced from the rotational alignment of the femoral component. Different implant philosophies use different landmarks for rotational alignment, as the epicondylar line, the posterior condyles or the anteroposterior line. An individual variation of the different landmarks is known from manual implantation an cadaver and CT studies. The purpose of this study was to measure the variation of three different lines for femoral rotational alignment to show the possible difference and check the so far used values in manual instrumentation technique. Design/methods: Using the Navitrack Navigation system we performed 100 consecutive TKRs. The landmarks for the 3 most common lines for rotational alignment of the femoral component has been probed. The software calculated the position of the lines and the 3-dimensional ankle between the lines. Intraoperative snapshots were taken to postoperative data analysis of the numeric data. Results: The mean difference between the ECL and the PCL was –0,96 (SD 3,64; range −10.7 − 5,9). In varus knees −0,2 (−6 −4,5) in valgus knees 1,4 (–10,7 – 5,9). ECL to the APC was in mean 88,83 (SD 7,23; range 100,8 – 71,9). In varus knees 91,3 (99 – 76,2) in valgus knees 83,8 (100,8 – 71,9). Conclusions: Using a navigation system it is easy to perform an individual, intraoperative measurement of the relationship of different anatomical landmarks for rotational alignment of the femoral component. But the range of values shows that in the manual technique with fixed rotational alignment given by the instruments, there is a high risk for femoral rotational malalignment. The results depended on preoperative deformity could only be seen as a bias for higher variance in valgus knees. For the navigation procedures there is not one universal landmark which can be used. Furthermore the systems must be developed for intraoperative functional analysis, with integration of soft tissue balancing, to improve functional and long-term outcome in TKR


Bone & Joint Open
Vol. 3, Issue 10 | Pages 741 - 745
1 Oct 2022
Baldock TE Dixon JR Koubaesh C Johansen A Eardley WGP

Aims. Patients with A1 and A2 trochanteric hip fractures represent a substantial proportion of trauma caseload, and national guidelines recommend that sliding hip screws (SHS) should be used for these injuries. Despite this, intramedullary nails (IMNs) are routinely implanted in many hospitals, at extra cost and with unproven patient outcome benefit. We have used data from the National Hip Fracture Database (NHFD) to examine the use of SHS and IMN for A1 and A2 hip fractures at a national level, and to define the cost implications of management decisions that run counter to national guidelines. Methods. We used the NHFD to identify all operations for fixation of trochanteric fractures in England and Wales between 1 January 2021 and 31 December 2021. A uniform price band from each of three hip fracture implant manufacturers was used to set cost implications alongside variation in implant use. Results. We identified 18,156 A1 and A2 trochanteric hip fractures in 162 centres. Of these, 13,483 (74.3%) underwent SHS fixation, 2,352 (13.0%) were managed with short IMN, and 2,321 (12.8%) were managed with long IMN. Total cost of IMN added up to £1.89 million in 2021, and the clinical justification for this is unclear since rates of IMN use varied from 0% to 97% in different centres. Conclusion. Most trochanteric hip fractures are managed with SHS, in keeping with national guidelines. There is considerable variance between hospitals for implant choice, despite the lack of evidence for clinical benefit and cost-effectiveness of more expensive nailing systems. This suggests either a lack of awareness of national guidelines or a choice not to follow them. We encourage provider units to reassess their practice if outwith the national norm. Funding bodies should examine implant use closely in this population to prevent resource waste at a time of considerable health austerity. Cite this article: Bone Jt Open 2022;3(10):741–745


Bone & Joint Open
Vol. 4, Issue 6 | Pages 463 - 471
23 Jun 2023
Baldock TE Walshaw T Walker R Wei N Scott S Trompeter AJ Eardley WGP

Aims. This is a multicentre, prospective assessment of a proportion of the overall orthopaedic trauma caseload of the UK. It investigates theatre capacity, cancellations, and time to surgery in a group of hospitals that is representative of the wider population. It identifies barriers to effective practice and will inform system improvements. Methods. Data capture was by collaborative approach. Patients undergoing procedures from 22 August 2022 and operated on before 31 October 2022 were included. Arm one captured weekly caseload and theatre capacity. Arm two concerned patient and injury demographics, and time to surgery for specific injury groups. Results. Data was available from 90 hospitals across 86 data access groups (70 in England, two in Wales, ten in Scotland, and four in Northern Ireland). After exclusions, 709 weeks' of data on theatre capacity and 23,138 operations were analyzed. The average number of cases per operating session was 1.73. Only 5.8% of all theatre sessions were dedicated day surgery sessions, despite 29% of general trauma patients being eligible for such pathways. In addition, 12.3% of patients experienced at least one cancellation. Delays to surgery were longest in Northern Ireland and shortest in England and Scotland. There was marked variance across all fracture types. Open fractures and fragility hip fractures, influenced by guidelines and performance renumeration, had short waits, and varied least. In all, nine hospitals had 40 or more patients waiting for surgery every week, while seven had less than five. Conclusion. There is great variability in operative demand and list provision seen in this study of 90 UK hospitals. There is marked variation in nearly all injuries apart from those associated with performance monitoring. There is no evidence of local network level coordination of care for orthopaedic trauma patients. Day case operating and pathways of care are underused and are an important area for service improvement. Cite this article: Bone Jt Open 2023;4(6):463–471


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 180 - 189
1 Feb 2023
Tohidi M Mann SM Groome PA

Aims. This study aimed to describe practice variation in the use of total hip arthroplasty (THA) for older patients with femoral neck fracture and to determine the association between patient, surgeon, and institution factors and treatment with THA. Methods. We performed a cross-sectional analysis of 49,597 patients aged 60 years and older from Ontario, Canada, who underwent hemiarthroplasty or THA for femoral neck fracture between 2002 and 2017. This population-based study used routinely collected healthcare databases linked through ICES (formerly known as the Institute for Clinical Evaluative Sciences). Multilevel logistic regression modelling was used to quantify the association between patient, surgeon, and institution-level variables and whether patients were treated with THA. Variance partition coefficient and median odds ratios were used to estimate the variation attributable to higher-level variables and the magnitude of effect of higher-level variables, respectively. Results. Over the study period, 9.4% of patients (n = 4,638) were treated with THA. Patient factors associated with higher likelihood of treatment by THA included: younger age, male sex, and diagnosis with rheumatoid arthritis. Long-term care residence, use of home care services prior to hip fracture, diagnosis of dementia, higher comorbidity burden, and the most marginalized group were negatively associated with treatment by THA. Treating surgeon and institution accounted for 54.2% and 17.8% of the total variation in treatment with THA, respectively. Surgeon volume of THA procedures in the 365 days prior to surgery was the strongest higher-level predictor of treatment with THA. Specific treating surgeons and institutions still accounted for significant proportions of the variability in treatment with THA (40.3% and 19.5% of total observed variation, respectively) after controlling for available patient, surgeon, and institution-level variables. Conclusion. The strongest predictors for treatment of patients with femoral neck fracture with THA were patient age, treating surgeon, and treating institution. This practice variation highlights differential access to care for patients. Cite this article: Bone Joint J 2023;105-B(2):180–189


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1142 - 1147
3 Oct 2022
van den Berg C van der Zwaard B Halperin J van der Heijden B

Aims. The aim of this retrospective study was to evaluate the rate of conversion to surgical release after a steroid injection in patients with a trigger finger, and to analyze which patient- and trigger finger-related factors affect the outcome of an injection. Methods. The medical records of 500 patients (754 fingers) treated for one or more trigger fingers with a steroid injection or with surgical release, between 1 January 2016 and 1 April 2020 with a follow-up of 12 months, were analyzed. Conversion to surgical release was recorded as an unsuccessful treatment after an injection. The effect of patient- and trigger finger-related characteristics on the outcome of an injection was assessed using stepwise manual backward multivariate logistic regression analysis. Results. Treatment with an injection was unsuccessful in 230 fingers (37.9%). Female sex (odds ratio (OR) 1.87 (95% confidence interval (CI) 1.21 to 2.88)), Quinnell stage IV (OR 16.01 (95% CI 1.66 to 154.0)), heavy physical work (OR 1.60 (95% CI 0.96 to 2.67)), a third steroid injection (OR 2.02 (95% CI 1.06 to 3.88)), and having carpal tunnel syndrome (OR 1.59 (95% CI 0.98 to 2.59)) were associated with a higher risk of conversion to surgical release. In contrast, an older age (OR 0.98 (95% CI 0.96 to 0.99)), smoking (OR 0.39 (95% CI 0.24 to 0.64)), and polypharmacy (OR 0.39, CI 0.12 to 1.12) were associated with a lower risk of conversion. The regression model predicted 15.6% of the variance found for the outcome of the injection treatment (R. 2. > 0.25). Conclusion. Factors associated with a worse outcome following a steroid injection were identified and should be considered when choosing the treatment of a trigger finger. In women with a trigger finger, the choice of treatment should take into account whether there are also one or more patient- or trigger-related factors that increase the risk of conversion to surgery. Cite this article: Bone Joint J 2022;104-B(10):1142–1147


Bone & Joint Open
Vol. 4, Issue 3 | Pages 210 - 218
28 Mar 2023
Searle HKC Rahman A Desai AP Mellon SJ Murray DW

Aims. To assess the incidence of radiological lateral osteoarthritis (OA) at 15 years after medial unicompartmental knee arthroplasty (UKA) and assess the relationship of lateral OA with symptoms and patient characteristics. Methods. Cemented Phase 3 medial Oxford UKA implanted by two surgeons since 1998 for the recommended indications were prospectively followed. A 15-year cumulative revision rate for lateral OA of 5% for this series was previously reported. A total of 163 unrevised knees with 15-year (SD 1) anterior-posterior knee radiographs were studied. Lateral joint space width (JSW. L. ) was measured and severity of lateral OA was classified as: nil/mild, moderate, and severe. Preoperative and 15-year Oxford Knee Scores (OKS) and American Knee Society Scores were determined. The effect of age, sex, BMI, and intraoperative findings was analyzed. Statistical analysis included one-way analysis of variance and Kruskal-Wallis H test, with significance set at 5%. Results. The mean age was 80.6 years (SD 8.3), with 84 females and 79 males. The mean JSW. L. was 5.6 mm (SD 1.4), and was not significantly related to age, sex, or intraoperative findings. Those with BMI > 40 kg/m. 2. had a smaller JSW. L. than those with a ‘normal’ BMI (p = 0.039). The incidence of severe and moderate lateral OA were both 4.9%. Overall, 2/142 (1.4%) of those with nil/mild lateral OA, 1/8 (13%) with moderate, and 2/8 (25%) with severe subsequently had a revision. Those with severe (mean OKS 35.6 (SD 9.3)) and moderate OA (mean OKS 35.8 (SD 10.5)) tended to have worse outcome scores than those with nil/mild (mean OKS 39.5 (SD 9.2)) but the difference was only significant for OKS-Function (p = 0.044). Conclusion. This study showed that the rate of having severe or moderate radiological lateral OA at 15 years after medial UKA was low (both 4.9%). Although patients with severe or moderate lateral OA had a lower OKS than those with nil/mild OA, their mean scores (OKS 36) would be classified as good. Cite this article: Bone Jt Open 2023;4(3):210–218


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 331 - 340
1 Mar 2022
Strahl A Kazim MA Kattwinkel N Hauskeller W Moritz S Arlt S Niemeier A

Aims. The aim of this study was to determine whether total hip arthroplasty (THA) for chronic hip pain due to unilateral primary osteoarthritis (OA) has a beneficial effect on cognitive performance. Methods. A prospective cohort study was conducted with 101 patients with end-stage hip OA scheduled for THA (mean age 67.4 years (SD 9.5), 51.5% female (n = 52)). Patients were assessed at baseline as well as after three and months. Primary outcome was cognitive performance measured by d2 Test of Attention at six months, Trail Making Test (TMT), FAS-test, Rivermead Behavioural Memory Test (RBMT; story recall subtest), and Rey-Osterrieth Complex Figure Test (ROCF). The improvement of cognitive performance was analyzed using repeated measures analysis of variance. Results. At six months, there was significant improvement in attention, working speed and concentration (d2-test; p < 0.001), visual construction and visual memory (ROCF; p < 0.001), semantic memory (FAS-test; p = 0.009), verbal episodic memory (RBMT; immediate recall p = 0.023, delayed recall p = 0.026), as well as pain (p < 0.001) with small to large effect sizes. Attention, concentration, and visual as well as verbal episodic memory improved significantly with medium effect sizes over η. 2. partial. = 0.06. In these cognitive domains the within-group difference exceeded the minimum clinically important difference. Conclusion. THA is associated with clinically relevant postoperative improvement in the cognitive functions of attention, concentration, and memory. These data support the concept of a broad interaction of arthroplasty with central nervous system function. Cite this article: Bone Joint J 2022;104-B(3):331–340


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1086 - 1093
1 Oct 2023
Kolin DA Sculco PK Gonzalez Della Valle A Rodriguez JA Ast MP Chalmers BP

Aims. Blood transfusion and postoperative anaemia are complications of total knee arthroplasty (TKA) that are associated with substantial healthcare costs, morbidity, and mortality. There are few data from large datasets on the risk factors for these complications. Methods. We retrospectively reviewed the records of TKA patients from a single tertiary care institution from February 2016 to December 2020. There were a total of 14,901 patients in this cohort with a mean age of 67.9 years (SD 9.2), and 5,575 patients (37.4%) were male. Outcomes included perioperative blood transfusion and postoperative anaemia, defined a priori as haemoglobin level < 10 g/dl measured on the first day postoperatively. In order to establish a preoperative haemoglobin cutoff, we investigated a preoperative haemoglobin level that would limit transfusion likelihood to ≤ 1% (13 g/dl) and postoperative anaemia likelihood to 4.1%. Risk factors were assessed through multivariable Poisson regression modelling with robust error variance. Results. In multivariable analyses, each gram of tranexamic acid reduced transfusion likelihood by 39% (adjusted risk ratio (ARR) 0.61 (95% confidence interval (CI) 0.47 to 0.78)). Risk factors associated with an increased risk of transfusion included operating time (ARR 2.07 (95% CI 1.54 to 2.77)) and drain use (ARR 1.73 (95% CI 1.34 to 2.24)). Conclusion. In this study, we found that increased tranexamic acid dosing, decreased operating time, and decreased drain use may reduce transfusions following TKA. We also established a single preoperative haemoglobin cutoff of 13 g/dl that could help minimize transfusions and reduce postoperative complete blood counts. Cite this article: Bone Joint J 2023;105-B(10):1086–1093


Bone & Joint Research
Vol. 13, Issue 4 | Pages 193 - 200
23 Apr 2024
Reynolds A Doyle R Boughton O Cobb J Muirhead-Allwood S Jeffers J

Aims

Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies.

Methods

Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment.


Bone & Joint Open
Vol. 3, Issue 8 | Pages 607 - 610
1 Aug 2022
Wellington IJ Hawthorne BC Dorsey C Connors JP Mazzocca AD Solovyova O

Aims

Tissue adhesives (TAs) are a commonly used adjunct to traditional surgical wound closures. However, TAs must be allowed to dry before application of a surgical dressing, increasing operating time and reducing intraoperative efficiency. The goal of this study is to identify a practical method for decreasing the curing time for TAs.

Methods

Six techniques were tested to determine which one resulted in the quickest drying time for 2-octyle cyanoacrylate (Dermabond) skin adhesive. These were nothing (control), fanning with a hand (Fanning), covering with a hand (Covering), bringing operating room lights close (OR Lights), ultraviolet lights (UV Light), or prewarming the TA applicator in a hot water bath (Hot Water Bath). Equal amounts of TA were applied to a reproducible plexiglass surface and allowed to dry while undergoing one of the six techniques. The time to complete dryness was recorded for ten specimens for each of the six techniques.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 120 - 128
1 Mar 2023
Franco H Saxby N Corlew DS Perry DC Pigeolet M

Aims

Within healthcare, several measures are used to quantify and compare the severity of health conditions. Two common measures are disability weight (DW), a context-independent value representing severity of a health state, and utility weight (UW), a context-dependent measure of health-related quality of life. Neither of these measures have previously been determined for developmental dysplasia of the hip (DDH). The aim of this study is to determine the DW and country-specific UWs for DDH.

Methods

A survey was created using three different methods to estimate the DW: a preference ranking exercise, time trade-off exercise, and visual analogue scale (VAS). Participants were fully licensed orthopaedic surgeons who were contacted through national and international orthopaedic organizations. A global DW was calculated using a random effects model through an inverse-variance approach. A UW was calculated for each country as one minus the country-specific DW composed of the time trade-off exercise and VAS.


Bone & Joint Research
Vol. 11, Issue 2 | Pages 134 - 142
23 Feb 2022
Luo P Cheng S Zhang F Feng R Xu K Jing W Xu P

Aims

The aim of this study was to explore the genetic correlation and causal relationship between blood plasma proteins and rheumatoid arthritis (RA).

Methods

Based on the genome-wide association studies (GWAS) summary statistics of RA from European descent and the GWAS summary datasets of 3,622 plasma proteins, we explored the relationship between RA and plasma proteins from three aspects. First, linkage disequilibrium score regression (LD score regression) was applied to detect the genetic correlation between RA and plasma proteins. Mendelian randomization (MR) analysis was then used to evaluate the causal association between RA and plasma proteins. Finally, GEO2R was used to screen the differentially expressed genes (DEGs) between patients with RA and healthy controls.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 65 - 65
17 Nov 2023
Khatib N Schmidtke L Lukens A Arichi T Nowlan N Kainz B
Full Access

Abstract. Objectives. Neonatal motor development transitions from initially spontaneous to later increasingly complex voluntary movements. A delay in transitioning may indicate cerebral palsy (CP). The general movement optimality score (GMOS) evaluates infant movement variety and is used to diagnose CP, but depends on specialized physiotherapists, is time-consuming, and is subject to inter-observer differences. We hypothesised that an objective means of quantifying movements in young infants using motion tracking data may provide a more consistent early diagnosis of CP and reduce the burden on healthcare systems. This study assessed lower limb kinematic and muscle force variances during neonatal infant kicking movements, and determined that movement variances were associated with GMOS scores, and therefore CP. Methods. Electromagnetic motion tracking data (Polhemus) was collected from neonatal infants performing kicking movements (min 50° knee extension-flexion, <2 seconds) in the supine position over 7 minutes. Tracking data from lower limb anatomical landmarks (midfoot inferior, lateral malleolus, lateral knee epicondyle, ASIS, sacrum) were applied to subject-scaled musculoskeletal models (Gait2354_simbody, OpenSim). Inverse kinematics and static optimisation were applied to estimate lower limb kinematics (knee flexion, hip flexion, hip adduction) and muscle forces (quadriceps femoris, biceps femoris) for isolated kicks. Functional principal component analysis (fPCA) was carried out to reduce kicking kinematic and muscle force waveforms to PC scores capturing ‘modes’ of variance. GMOS scores (lower scores = reduced variety of movement) were collected in parallel with motion capture by a trained operator and specialised physiotherapist. Pearson's correlations were performed to assess if the standard deviation (SD) of kinematic and muscle force waveform PC scores, representing the intra-subject variance of movement or muscle activation, were associated with the GMOS scores. Results. The study compared GMOS scores, kinematics, and muscle force variances from a total of 26 infants with a mean corrected gestational age of 39.7 (±3.34) weeks and GMOS scores between 21 and 40. There was a significant association between the SD of the PC scores for knee flexion and the GMOS scores (PC1: R = 0.59, p = 0.002; PC2: R = 0.49, p = 0.011; PC3: R = 0.56, p = 0.003). The three PCs captured variances of the overall flexion magnitude (66% variance explained), early-to-late kick knee extension (20%), and continual to biphasic kicking (6%). For hip flexion, only the SD of PC1 correlated with GMOS scores (PC1: R = 0.52, p = 0.0068), which captured the variance of the overall flexion magnitude (81%). For the biceps femoris, the SD of PC1 and PC3 associated with GMOS scores (PC1: R = 0.50, p = 0.002; PC3: R = 0.45, p = 0.03), which captured the variance of the overall bicep force magnitude (79%) and early-to-late kick bicep activation (8%). Conclusions. Infants with reduced motor development as scored in the GMOS displayed reduced variances of knee and hip flexion and biceps femoris activation across kicking cycles. These findings suggest that combining objectively measured movement variances with existing classification methods could facilitate the development of more consistent and accurate diagnostic tools for early detection of CP. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project