Advertisement for orthosearch.org.uk
Results 1 - 20 of over 10000
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 112 - 119
1 Jan 2022
Pietton R Bouloussa H Langlais T Taytard J Beydon N Skalli W Vergari C Vialle R

Aims. This study addressed two questions: first, does surgical correction of an idiopathic scoliosis increase the volume of the rib cage, and second, is it possible to evaluate the change in lung function after corrective surgery for adolescent idiopathic scoliosis (AIS) using biplanar radiographs of the ribcage with 3D reconstruction?. Methods. A total of 45 patients with a thoracic AIS which needed surgical correction and fusion were included in a prospective study. All patients underwent pulmonary function testing (PFT) and low-dose biplanar radiographs both preoperatively and one year after surgery. The following measurements were recorded: forced vital capacity (FVC), slow vital capacity (SVC), and total lung capacity (TLC). Rib cage volume (RCV), maximum rib hump, main thoracic curve Cobb angle (MCCA), medial-lateral and anteroposterior diameter, and T4-T12 kyphosis were calculated from 3D reconstructions of the biplanar radiographs. Results. All spinal and thoracic measurements improved significantly after surgery (p < 0.001). RCV increased from 4.9 l (SD 1) preoperatively to 5.3 l (SD 0.9) (p < 0.001) while TLC increased from 4.1 l (SD 0.9) preoperatively to 4.3 l (SD 0.8) (p < 0.001). RCV was correlated with all functional indexes before and after correction of the deformity. Improvement in RCV was weakly correlated with correction of the mean thoracic Cobb angle (p = 0.006). The difference in TLC was significantly correlated with changes in RCV (p = 0.041). It was possible to predict postoperative TLC from the postoperative RCV. Conclusion. 3D rib cage assessment from biplanar radiographs could be a minimally invasive method of estimating pulmonary function before and after spinal fusion in patients with an AIS. The 3D RCV reflects virtual chest capacity and hence pulmonary function in this group of patients. Cite this article: Bone Joint J 2022;104-B(1):112–119


Bone & Joint Open
Vol. 3, Issue 12 | Pages 960 - 968
23 Dec 2022
Hardwick-Morris M Wigmore E Twiggs J Miles B Jones CW Yates PJ

Aims. Leg length discrepancy (LLD) is a common pre- and postoperative issue in total hip arthroplasty (THA) patients. The conventional technique for measuring LLD has historically been on a non-weightbearing anteroposterior pelvic radiograph; however, this does not capture many potential sources of LLD. The aim of this study was to determine if long-limb EOS radiology can provide a more reproducible and holistic measurement of LLD. Methods. In all, 93 patients who underwent a THA received a standardized preoperative EOS scan, anteroposterior (AP) radiograph, and clinical LLD assessment. Overall, 13 measurements were taken along both anatomical and functional axes and measured twice by an orthopaedic fellow and surgical planning engineer to calculate intraoperator reproducibility and correlations between measurements. Results. Strong correlations were observed for all EOS measurements (r. s. > 0.9). The strongest correlation with AP radiograph (inter-teardrop line) was observed for functional-ASIS-to-floor (functional) (r. s. = 0.57), much weaker than the correlations between EOS measurements. ASIS-to-ankle measurements exhibited a high correlation to other linear measurements and the highest ICC (r. s. = 0.97). Using anterior superior iliac spine (ASIS)-to-ankle, 33% of patients had an absolute LLD of greater than 10 mm, which was statistically different from the inter-teardrop LLD measurement (p < 0.005). Discussion. We found that the conventional measurement of LLD on AP pelvic radiograph does not correlate well with long leg measurements and may not provide a true appreciation of LLD. ASIS-to-ankle demonstrated improved detection of potential LLD than other EOS and radiograph measurements. Full length, functional imaging methods may become the new gold standard to measure LLD. Cite this article: Bone Jt Open 2022;3(12):960–968


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 7 - 7
1 Jun 2023
Harris PC Lacey S Steward A Sertori M Homan J
Full Access

Introduction. The various problems that are managed with circular external fixation (e.g. deformity, complex fractures) also typically require serial plain x-ray imaging. One of the challenges here is that the relatively radio-opaque components of the circular external fixator (e.g. the rings) can obscure the view of the area of interest (e.g. osteotomy site, fracture site). In this presentation we describe how the geometry of the x-ray beam affects the produced image and how we can use knowledge of this to our advantage. Whilst this can be applied to any long bone, we have focused on the tibia, given that it's the most common long bone that is treated by circular external fixation. Materials & Methods. In the first part of the presentation we describe the known attributes (geometry) of the x-ray beam and postulate what effect it would have when we x-ray a long bone that is surrounded by a circular external fixator. In the second part we demonstrate this in practice using a tibia and a 3 ring circular external fixator. Differing x-ray beam orientations are used to demonstrate both how the geometry of the beam affects the produced image and how we can use this to our advantage to better visualise part of the bone. Results. The practical part of the study confirmed the theoretical part. Conclusions. Knowledge of the beam geometry can be used to minimise the obscuring nature of the circular fixator. This technique is simple and can be easily taught to the radiographer. It is a useful adjunct for the limb reconstruction surgeon


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_9 | Pages 26 - 26
1 Oct 2022
Bell J Owen D Meek K Terrill N Sanchez-Weatherby J Le Maitre C
Full Access

Background. An improved understanding of intervertebral disc (IVD) structure and function is required for treatment development. Loading induces micro-fractures at the interface between the nucleus pulposus (NP) and the annulus fibrosus (AF), which is hypothesized to induce a cascade of cellular changes leading to degeneration. However, there is limited understanding of the structural relationship between the NP and AF at this interface and particularly response to load. Here, X-ray scattering is utilised to provide hierarchical morphometric information of collagen structure across the IVD, especially the interface region under load. Methodology. IVDs were imaged using the I22 SAXS/WAXS beamline at Diamond Light Source. Peaks associated with the D-banded structure of collagen fibrils were fitted to quantify their azimuthal distribution, as well the magnitude and direction of internal strains under static and applied strain (0–20%). Results. IVD tissue regions exhibited structural “AF-like” and “NP-like” fingerprints. Demonstrating high internal strains on collagen fibres particularly within the NP region of the disc. AF and NP regions showed distinct collagen orientation and internal strains with an apparent lack of bracing structure seen at the interface between the differential mechanical tissues. X-ray scattering under tensile strain provided structural information at high resolution, with clear differences observed between normal and degenerate discs under load. Conclusion. X ray scattering has been utilised to develop an improved understanding of collagen structure across the intervertebral disc which can be utilised to gain an increased understanding of load induced propagation of micro fissures and disc degeneration. Conflict of Interest: No conflict of interest. Funding: BioPro Network, UCL for funding this study through support from the MRC (MR/R025673/1)


Bone & Joint Open
Vol. 3, Issue 6 | Pages 502 - 509
20 Jun 2022
James HK Griffin J Pattison GTR

Aims. To identify a core outcome set of postoperative radiographic measurements to assess technical skill in ankle fracture open reduction internal fixation (ORIF), and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. An e-Delphi exercise was undertaken at a major trauma centre (n = 39) to identify relevant parameters. Feasibility was tested by two authors. Reliability and validity was tested using postoperative radiographs of ankle fracture operations performed by trainees enrolled in an educational trial (IRCTN 20431944). To determine construct validity, trainees were divided into novice (performed < ten cases at baseline) and intermediate groups (performed ≥ ten cases at baseline). To assess concurrent validity, the procedure-based assessment (PBA) was considered the gold standard. The inter-rater and intrarater reliability was tested using a randomly selected subset of 25 cases. Results. Overall, 235 ankle ORIFs were performed by 24 postgraduate year three to five trainees during ten months at nine NHS hospitals in England, UK. Overall, 42 PBAs were completed. The e-Delphi panel identified five ‘final product analysis’ parameters and defined acceptability thresholds: medial clear space (MCS); medial malleolar displacement (MMD); lateral malleolar displacement (LMD); tibiofibular clear space (TFCS) (all in mm); and talocrural angle (TCA) in degrees. Face validity, content validity, and feasibility were excellent. PBA global rating scale scores in this population showed excellent construct validity as continuous (p < 0.001) and categorical (p = 0.001) variables. Concurrent validity of all metrics was poor against PBA score. Intrarater reliability was substantial for all parameters (intraclass correlation coefficient (ICC) > 0.8), and inter-rater reliability was substantial for LMD, MMD, TCA, and moderate (ICC 0.61 to 0.80) for MCS and TFCS. Assessment was time efficient compared to PBA. Conclusion. Assessment of technical skill in ankle fracture surgery using the first postoperative radiograph satisfies the tested Van der Vleuten’s utility criteria for effective assessment. 'Final product analysis' assessment may be useful to assess skill transfer in the simulation-based research setting. Cite this article: Bone Jt Open 2022;3(6):502–509


Bone & Joint Research
Vol. 10, Issue 12 | Pages 830 - 839
15 Dec 2021
Robertson G Wallace R Simpson AHRW Dawson SP

Aims. Assessment of bone mineral density (BMD) with dual-energy X-ray absorptiometry (DXA) is a well-established clinical technique, but it is not available in the acute trauma setting. Thus, it cannot provide a preoperative estimation of BMD to help guide the technique of fracture fixation. Alternative methods that have been suggested for assessing BMD include: 1) cortical measures, such as cortical ratios and combined cortical scores; and 2) aluminium grading systems from preoperative digital radiographs. However, limited research has been performed in this area to validate the different methods. The aim of this study was to investigate the evaluation of BMD from digital radiographs by comparing various methods against DXA scanning. Methods. A total of 54 patients with distal radial fractures were included in the study. Each underwent posteroanterior (PA) and lateral radiographs of the injured wrist with an aluminium step wedge. Overall 27 patients underwent routine DXA scanning of the hip and lumbar spine, with 13 undergoing additional DXA scanning of the uninjured forearm. Analysis of radiographs was performed on ImageJ and Matlab with calculations of cortical measures, cortical indices, combined cortical scores, and aluminium equivalent grading. Results. Cortical measures showed varying correlations with the forearm DXA results (range: Pearson correlation coefficient (r) = 0.343 (p = 0.251) to r = 0.521 (p = 0.068)), with none showing statistically significant correlations. Aluminium equivalent grading showed statistically significant correlations with the forearm DXA of the corresponding region of interest (p < 0.017). Conclusion. Cortical measures, cortical indices, and combined cortical scores did not show a statistically significant correlation to forearm DXA measures. Aluminium-equivalent is an easily applicable method for estimation of BMD from digital radiographs in the preoperative setting. Cite this article: Bone Joint Res 2021;10(12):830–839


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1662 - 1668
1 Nov 2021
Bhanushali A Chimutengwende-Gordon M Beck M Callary SA Costi K Howie DW Solomon LB

Aims. The aims of this study were to compare clinically relevant measurements of hip dysplasia on radiographs taken in the supine and standing position, and to compare Hip2Norm software and Picture Archiving and Communication System (PACS)-derived digital radiological measurements. Methods. Preoperative supine and standing radiographs of 36 consecutive patients (43 hips) who underwent periacetabular osteotomy surgery were retrospectively analyzed from a single-centre, two-surgeon cohort. Anterior coverage (AC), posterior coverage (PC), lateral centre-edge angle (LCEA), acetabular inclination (AI), sharp angle (SA), pelvic tilt (PT), retroversion index (RI), femoroepiphyseal acetabular roof (FEAR) index, femoroepiphyseal horizontal angle (FEHA), leg length discrepancy (LLD), and pelvic obliquity (PO) were analyzed using both Hip2Norm software and PACS-derived measurements where applicable. Results. Analysis of supine and standing radiographs resulted in significant variation for measurements of PT (p < 0.001) and AC (p = 0.005). The variation in PT correlated with the variation in AC in a limited number of patients (R. 2. = 0.378; p = 0.012). Conclusion. The significant variation in PT and AC between supine and standing radiographs suggests that it may benefit surgeons to have both radiographs when planning surgical correction of hip dysplasia. We also recommend using PACS-derived measurements of AI and SA due to the poor interobserver error on Hip2Norm. Cite this article: Bone Joint J 2021;103-B(11):1662–1668


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1062 - 1071
1 Aug 2020
Cheung JPY Fong HK Cheung PWH

Aims. To determine the effectiveness of prone traction radiographs in predicting postoperative slip distance, slip angle, changes in disc height, and lordosis after surgery for degenerative spondylolisthesis of the lumbar spine. Methods. A total of 63 consecutive patients with a degenerative spondylolisthesis and preoperative prone traction radiographs obtained since 2010 were studied. Slip distance, slip angle, disc height, segmental lordosis, and global lordosis (L1 to S1) were measured on preoperative lateral standing radiographs, flexion-extension lateral radiographs, prone traction lateral radiographs, and postoperative lateral standing radiographs. Patients were divided into two groups: posterolateral fusion or posterolateral fusion with interbody fusion. Results. The mean changes in segmental lordosis and global lordosis were 7.1° (SD 6.7°) and 2.9° (SD 9.9°) respectively for the interbody fusion group, and 0.8° (SD 5.1°) and -0.4° (SD 10.1°) respectively for the posterolateral fusion-only group. Segmental lordosis (ρ = 0.794, p < 0.001) corrected by interbody fusion correlated best with prone traction radiographs. Global lumbar lordosis (ρ = 0.788, p < 0.001) correlated best with the interbody fusion group and preoperative lateral standing radiographs. The least difference in slip distance (-0.3 mm (SD 1.7 mm), p < 0.001), slip angle (0.9° (SD 5.2°), p < 0.001), and disc height (0.02 mm (SD 2.4 mm), p < 0.001) was seen between prone traction and postoperative radiographs. Regression analyses suggested that prone traction parameters best predicted correction of slip distance (Corrected Akaike’s Information Criterion (AICc) = 37.336) and disc height (AICc = 58.096), while correction of slip angle (AICc = 26.453) was best predicted by extension radiographs. Receiver operating characteristic (ROC) cut-off showed, with 68.3% sensitivity and 64.5% specificity, that to achieve a 3.0° increase in segmental lordotic angle, patients with a prone traction disc height of 8.5 mm needed an interbody fusion. Conclusion. Prone traction radiographs best predict the slip distance and disc height correction achieved by interbody fusion for lumbar degenerative spondylolisthesis. To achieve this maximum correction, interbody fusion should be undertaken if a disc height of more than 8.5 mm is attained on preoperative prone traction radiographs. Level of Evidence: Level II Prognostic Study. Cite this article: Bone Joint J 2020;102-B(8):1062–1071


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 59 - 65
1 Jul 2021
Bracey DN Hegde V Shimmin AJ Jennings JM Pierrepont JW Dennis DA

Aims. Cross-table lateral (CTL) radiographs are commonly used to measure acetabular component anteversion after total hip arthroplasty (THA). The CTL measurements may differ by > 10° from CT scan measurements but the reasons for this discrepancy are poorly understood. Anteversion measurements from CTL radiographs and CT scans are compared to identify spinopelvic parameters predictive of inaccuracy. Methods. THA patients (n = 47; 27 males, 20 females; mean age 62.9 years (SD 6.95)) with preoperative spinopelvic mobility, radiological analysis, and postoperative CT scans were retrospectively reviewed. Acetabular component anteversion was measured on postoperative CTL radiographs and CT scans using 3D reconstructions of the pelvis. Two cohorts were identified based on a CTL-CT error of ≥ 10° (n = 11) or < 10° (n = 36). Spinopelvic mobility parameters were compared using independent-samples t-tests. Correlation between error and mobility parameters were assessed with Pearson’s coefficient. Results. Patients with CTL error > 10° (10° to 14°) had stiffer lumbar spines with less mean lumbar flexion (38.9°(SD 11.6°) vs 47.4° (SD 13.1°); p = 0.030), different sagittal balance measured by pelvic incidence-lumbar lordosis mismatch (5.9° (SD 18.8°) vs -1.7° (SD 9.8°); p = 0.042), more pelvic extension when seated (pelvic tilt -9.7° (SD 14.1°) vs -2.2° (SD 13.2°); p = 0.050), and greater change in pelvic tilt between supine and seated positions (12.6° (SD 12.1°) vs 4.7° (SD 12.5°); p = 0.036). The CTL measurement error showed a positive correlation with increased CTL anteversion (r = 0.5; p = 0.001), standing lordosis (r = 0.23; p = 0.050), seated lordosis (r = 0.4; p = 0.009), and pelvic tilt change between supine and step-up positions (r = 0.34; p = 0.010). Conclusion. Differences in spinopelvic mobility may explain the variability of acetabular anteversion measurements made on CTL radiographs. Patients with stiff spines and increased compensatory pelvic movement have less accurate measurements on CTL radiographs. Flexion of the contralateral hip is required to obtain clear CTL radiographs. In patients with lumbar stiffness, this movement may extend the pelvis and increase anteversion of the acetabulum on CTL views. Reliable analysis of acetabular component anteversion in this patient population may require advanced imaging with a CT scan. Cite this article: Bone Joint J 2021;103-B(7 Supple B):59–65


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 43 - 43
7 Aug 2023
Lewis A Bucknall K Davies A Evans A Jones L Triscott J Hutchison A
Full Access

Abstract. Introduction. A lipohaemarthrosis seen on Horizontal beam lateral X-ray in acute knee injury is often considered predictive of an intra-articular fracture requiring further urgent imaging. Methodology. We retrospectively searched a five-year X-ray database for the term “lipohaemarthrosis”. We excluded cases if the report concluded “no lipohaemarthrosis” or “lipohaemarthrosis” AND “fracture”. All remaining cases were reviewed by an Orthopaedic Consultant with a special interest in knee injuries (AD) blinded to the report. X-rays were excluded if a fracture was seen, established osteoarthritic change was present, a pre-existing arthroplasty present or no lipohaemarthrosis present. Remaining cases were then studied for any subsequent Radiological or Orthopaedic surgical procedures. Results. 136 cases were identified and reviewed by an Orthopaedic Consultant. 31 were excluded for no lipohaemarthrosis (n= 11), for degenerative change (n=9), for fracture (n=4), for existing arthroplasty (n=4) and for data errors (n=3). The remaining 105 patients had a mean age of 32, and range 5–90 years. 66 patients underwent further imaging in the form of MRI scan (n=47), CT Scan (n=9) repeat x-rays (n=9) and ultrasound (n=1). 27 fractures were identified. Surgery was performed in 12 cases (11%). Two (2%) urgently (One ACL reconstruction plus meniscus repair, one for ORIF of tibial plateau fracture). Ten (10%) had elective surgery (6 for ACL reconstruction, 2 for ACL reconstruction plus meniscus repair, 2 for loose body removal. Conclusion. The presence of a lipohaemarthrosis on x-ray following acute knee injury was a poor predictor of intra-articular fracture (26%) or need for urgent surgery (2%)


Bone & Joint Research
Vol. 10, Issue 3 | Pages 173 - 187
1 Mar 2021
Khury F Fuchs M Awan Malik H Leiprecht J Reichel H Faschingbauer M

Aims. To explore the clinical relevance of joint space width (JSW) narrowing on standardized-flexion (SF) radiographs in the assessment of cartilage degeneration in specific subregions seen on MRI sequences in knee osteoarthritis (OA) with neutral, valgus, and varus alignments, and potential planning of partial knee arthroplasty. Methods. We retrospectively reviewed 639 subjects, aged 45 to 79 years, in the Osteoarthritis Initiative (OAI) study, who had symptomatic knees with Kellgren and Lawrence grade 2 to 4. Knees were categorized as neutral, valgus, and varus knees by measuring hip-knee-angles on hip-knee-ankle radiographs. Femorotibial JSW was measured on posteroanterior SF radiographs using a special software. The femorotibial compartment was divided into 16 subregions, and MR-tomographic measurements of cartilage volume, thickness, and subchondral bone area were documented. Linear regression with adjustment for age, sex, body mass index, and Kellgren and Lawrence grade was used. Results. We studied 345 neutral, 87 valgus, and 207 varus knees. Radiological JSW narrowing was significantly (p < 0.01) associated with cartilage volume and thickness in medial femorotibial compartment in neutral (r = 0.78, odds ratio (OR) 2.33) and varus knees (r = 0.86, OR 1.92), and in lateral tibial subregions in valgus knees (r = 0.87, OR 3.71). A significant negative correlation was found between JSW narrowing and area of subchondral bone in external lateral tibial subregion in valgus knees (r = −0.65, p < 0.01) and in external medial tibial subregion in varus knees (r = −0.77, p < 0.01). No statistically significant correlation was found in anterior and posterior subregions. Conclusion. SF radiographs can be potentially used for initial detection of cartilage degeneration as assessed by MRI in medial and lateral but not in anterior or posterior subregions. Cite this article: Bone Joint Res 2021;10(3):173–187


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 30 - 30
17 Nov 2023
Swain L Holt C Williams D
Full Access

Abstract. Objectives. Investigate Magnetic Resonance Imaging (MRI) as an alternative to Computerised Tomography (CT) when calculating kinematics using Biplane Video X-ray (BVX) by quantifying the accuracy of a combined MRI-BVX methodology by comparing with results from a gold-standard bead-based method. Methods. Written informed consent was given by one participant who had four tantalum beads implanted into their distal femur and proximal tibia from a previous study. Three-dimensional (3D) models of the femur and tibia were segmented (Simpleware Scan IP, Synopsis) from an MRI scan (Magnetom 3T Prisma, Siemens). Anatomical Coordinate Systems (ACS) were applied to the bone models using automated algorithms. 1. The beads were segmented from a previous CT and co-registered with the MRI bone models to calculate their positions. BVX (60 FPS, 1.25 ms pulse width) was recorded whilst the participant performed a lunge. The beads were tracked, and the ACS position of the femur and tibia were calculated at each frame (DSX Suite, C-Motion Inc.). The beads were digitally removed from the X-rays (MATLAB, MathWorks) allowing for blinded image-registration of the MRI models to the radiographs. The mean difference and standard deviation (STD) between bead-generated and image-registered bone poses were calculated for all degrees of freedom (DOF) for both bones. Using the principles defined by Grood and Suntay. 2. , 6 DOF kinematics of the tibiofemoral joint were calculated (MATLAB, MathWorks). The mean difference and STD between these two sets of kinematics were calculated. Results. The absolute mean femur and tibia ACS position differences (Table 1) between the bead and image-registered poses were found to be within 0.75mm for XYZ, with all STD within ±0.5mm. Mean rotation differences for both bones were found to be within 0.2º for XYZ (Table 1). The absolute mean tibiofemoral joint translations (Table 1) were found to be within ±0.7mm for all DOF, with the smallest absolute mean in compression-distraction. The absolute mean tibiofemoral rotations were found to be within 0.25º for all DOF (Table 1), with the smallest mean was found in abduction-adduction. The largest mean and STD were found in internal-external rotation due to the angle of the X-rays relative to the joint movement, increasing the difficulty of manual image registration in that plane. Conclusion. The combined MRI-BVX method produced bone pose and tibiofemoral kinematics accuracy similar to previous CT results. 3. This allows for confidence in future results, especially in clinical applications where high accuracy is needed to understand the effects of disease and the efficacy of surgical interventions. Acknowledgements: This research was supported by the Engineering and Physical Sciences Research Council (EPSRC) doctoral training grant (EP/T517951/1). Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 41 - 46
1 Jul 2020
Ransone M Fehring K Fehring T

Aims. Patients with abnormal spinopelvic mobility are at increased risk for instability. Measuring the change in sacral slope (ΔSS) can help determine spinopelvic mobility preoperatively. Sacral slope (SS) should decrease at least 10° to demonstrate adequate posterior pelvic tilt. There is potential for different ΔSS measurements in the same patient based on sitting posture. The purpose of this study was to determine the effect of sitting posture on the ΔSS in patients undergoing total hip arthroplasty (THA). Methods. In total, 51 patients undergoing THA were reviewed to quantify the variability in preoperative spinopelvic mobility when measuring two different sitting positions using SS for planning. Results. A total of 32 patients had standardized relaxed sitting radiographs, while 35 patients had standardized flexed sitting images. Of the 32 patients with relaxed sitting views, the mean ΔSS was 20.7° (SD 8.9°). No patients exhibited an increase in SS during relaxed sitting (i.e. anterior pelvic tilt or so-called reverse accommodation). Of the 35 patients with flexed sitting radiographs, the mean ΔSS was only 2.1° (SD 9.7°) with 16/35 (45.71%) showing anterior pelvic tilt, or so-called reverse accommodation, unexpectedly increasing the sitting SS compared to the standing SS. Overall, 18 patients had both relaxed sitting and flexed sitting radiographs. In patients with both types of sitting radiographs, the mean relaxed sit to stand ΔSS was 18.06° (SD 6.07°), while only a 3.00° (SD 10.53°) ΔSS was noted when flexed sitting. There was a mean ΔSS difference of 15.06° (SD 7.67°) noted in the same patient cohort depending on sitting posture (p < 0.001). Conclusion. A 15° mean difference was noted depending on the sitting posture of the patient. Since decisions on component position can be made on preoperative lateral sit-stand radiographs, postural standardization is crucial. If using ΔSS for preoperative planning, the relaxed sitting radiograph is preferred. Cite this article: Bone Joint J 2020;102-B(7 Supple B):41–46


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 94 - 94
1 Feb 2020
Hagio K Akiyama K Aikawa K Saito M
Full Access

Introduction. In our institution, we started to perform THA with SuperPATH approach, including preservation of soft tissue around the hip (James Chow et al. Musculoskelet Med 2011) since July 2014, aiming for fast recovery and prevention of hip dislocation. For minimally-invasive approaches, however, there have been a few reports on malalignment of the implants related to shortage of operative field. The purpose of this study is to examine the short-term results of THA using SuperPATH, especially implant alignment. Materials and methods. We performed a study of 45 patients (45 hips) with osteoarthritis of the hip joint who had a THA with SuperPATH approach. There were 8 men and 37 women with an average age of 73 years, which were minimally 24 months followed. Dynasty Bioform cup and Profemur Z stem (Microport Orthopaedics) were used for all cases. Patients were clinically assessed with Merle d'Aubigne score and complications. Implant alignment and stability were radiologically evaluated by annual X-ray and CT acquired two months after surgery. Results. Merle d'Aubigne score was 10.2 (pain:2.8, mobility:4.4 walking ability:3.0) preoperatively and 16.6(pain:5.8, mobility:5.8, walking ability:5.0) at the latest follow-up. There were no dislocation and infection, but intraoperative proximal femoral fracture was found for two cases, which was managed to treat with additional circulating wire intraoperatively. Latest follow-up X-ray image showed 95% of the stem A-P alignment to be within 2 degrees and 5% to be more than 2 degrees and less than 5 degrees, while 44% of the stem lateral alignment to be within 2 degrees, 47% to be more than 2 degrees and less than 5 degrees, and 8% to be more than 5 degrees. From CT images averaged cup position found to be 40±5 degrees for inclination, and 19±5 degrees for anatomic anteversion, averaged stem anteversion to be 33±9 degrees. Annual X-ray evaluation showed no radiolucent line and less than Grade 2 stress-shielding (Engh classification) around the implants for all cases. One case had more than 5mm subsidence of the stem in early postoperative period, but not progressively subsided. No loosening of components was evident. Discussion and Conclusion. Many minimally-invasive approaches have developed, there have been many reports on fast recovery and low incidence of postoperative hip dislocation, however, the risk of complications or malalignment related to shortage of operative field has been pointed out. In this study, intraoperative proximal femoral fracture occurred for two cases. Also, though there were no loosening and the components position seemed excellent but lateral view of the X-ray showed 8% to be more than 5 degrees tilting alignment, resulting from femoral broaching required before femoral neck resection. SuperPATH approach, including pass way from between the Gluteus Medius and the piriformis tendon, can preserve the whole short external rotators and capsule of the hip joint, leading to fast recovery and low incidence of postoperative dislocation. Moreover, this approach may be friendly to the surgeons familiar with the posterior approach because of easily conversion to the conventional posterior approach


Bone & Joint Open
Vol. 1, Issue 9 | Pages 594 - 604
24 Sep 2020
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The feasibility of taking these measurements was tested by two of the authors (HKJ, GTRP). Validity and reliability were examined using the radiographs of operations performed by orthopaedic resident participants (n = 28) of a multicentre randomized controlled educational trial (ISRCTN20431944). Trainees were divided into novice and intermediate groups, defined as having performed < ten or ≥ ten cases each for DHS and hemiarthroplasty at baseline. The procedure-based assessment (PBA) global rating score was assumed as the gold standard assessment for the purposes of concurrent validity. Intra- and inter-rater reliability testing were performed on a random subset of 25 cases. Results. In total, 327 DHS and 248 hemiarthroplasty procedures were performed by 28 postgraduate year (PGY) 3 to 5 orthopaedic trainees during the 2014 to 2015 surgical training year at nine NHS hospitals in the West Midlands, UK. Overall, 109 PBAs were completed for DHS and 80 for hemiarthroplasty. Expert consensus identified four ‘final product analysis’ (FPA) radiological parameters of technical success for DHS: tip-apex distance (TAD); lag screw position in the femoral head; flushness of the plate against the lateral femoral cortex; and eight-cortex hold of the plate screws. Three parameters were identified for hemiarthroplasty: leg length discrepancy; femoral stem alignment; and femoral offset. Face validity, content validity, and feasibility were excellent. For all measurements, performance was better in the intermediate compared with the novice group, and this was statistically significant for TAD (p < 0.001) and femoral stem alignment (p = 0.023). Concurrent validity was poor when measured against global PBA score. This may be explained by the fact that they are measuring difference facets of competence. Intra-and inter-rater reliability were excellent for TAD, moderate for lag screw position (DHS), and moderate for leg length discrepancy (hemiarthroplasty). Use of a large multicentre dataset suggests good generalizability of the results to other settings. Assessment using FPA was time- and cost-effective compared with PBA. Conclusion. Final product analysis using post-implantation radiographs to measure technical skill in hip fracture surgery is feasible, valid, reliable, and cost-effective. It can complement traditional workplace-based assessment for measuring performance in the real-world operating room . It may have particular utility in competency-based training frameworks and for assessing skill transfer from the simulated to live operating theatre. Cite this article: Bone Joint Open 2020;1-9:594–604


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 27 - 27
1 Jul 2020
Hurry J Spurway A Dunbar MJ El-Hawary R
Full Access

Radiostereometric analysis (RSA) allows for precise measurement of interbody distances on X-ray images, such as movement between a joint replacement implant and the bone. The low radiation biplanar EOS imager (EOS imaging, France) scans patients in a weight-bearing position, provides calibrated three-dimensional information on bony anatomy, and could limit the radiation during serial RSA studies. Following the ISO-16087 standard, 15 double exams were conducted to determine the RSA precision of total knee arthroplasty (TKA) patients in the EOS imager, compared to the standard instantaneous, cone-beam, uniplanar digital X-ray set-up. At a mean of 5 years post-surgery, 15 TKA participants (mean 67 years, 12 female, 3 male) were imaged twice in the biplanar imager. To reduce motion during the scan, a support for the foot was added and the scan speed was increased. The voltage was also increased compared to standard settings for better marker visibility over the implant. A small calibration object was included to remove any remaining sway in post-processing. The 95% confidence interval precision was 0.11, 0.04, and 0.15 mm in the x, y, and z planes, respectively and 0.15, 0.20, and 0.14° in Rx, Ry, and Rz. Two participants had motion artifacts successfully removed during post-processing using the small calibration object. With faster speeds and stabilization support, this study found an in vivo RSA precision of ≤ 0.15 mm and ≤ 0.20° for TKA exams, which is within published uniplanar values for arthroplasty RSA. The biplanar imager also adds the benefits of weight bearing imaging, 3D alignment measurements, a lower radiation dose, and does not require a reference object due to known system geometry and automatic image registration


Bone & Joint Research
Vol. 5, Issue 9 | Pages 436 - 441
1 Sep 2016
Pinsornsak P Naratrikun K Kanitnate S Sangkomkamhang T

Objectives. The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Methods. Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis was evaluated using the joint space width and Kellgren-Lawrence (KL) radiographic classification. The t-test was used for statistical analysis. Results. The mean medial joint space width found in the one-leg and in the both-legs standing view were measured at 1.8 mm and 2.4 mm, respectively (p < 0.001, 95% CI 0.5 to 0.7). 33%, 47.4% and 23.1% of the knees diagnosed with a KL grade of I, II and III in the both-legs standing views were changed to KL grade II, III and IV in the one-leg standing views, respectively. No changes for KL IV osteoarthritis diagnoses have been found between both- and one-leg standing views. Conclusions. One-leg standing radiographs better represent joint space width than both-legs standing radiographs. 32% of both-legs standing radiographs have changed the KL grading to a more severe grade than that in the one-leg standing radiographs. Cite this article: P. Pinsornsak, K. Naratrikun, S. Kanitnate, T. Sangkomkamhang. The one-leg standing radiograph: An improved technique to evaluate the severity of knee osteoarthritis. Bone Joint Res 2016;5:436–441. DOI: 10.1302/2046-3758.59.BJR-2016-0049.R1


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 5 - 5
17 Jun 2024
Aamir J Caldwell R Karthikappallil D Tanaka H Elbannan M Mason L
Full Access

Background. Lisfranc fracture dislocations are uncommon injuries, which frequently require surgical intervention. Currently, there is varying evidence on the diagnostic utility of plain radiographs (XR) and CT in identifying Lisfranc injuries and concomitant fractures. Our aim was to identify the utility of XR as compared to CT, with the nul hypothesis that there was no difference in fracture identification. Methods. A retrospective assessment of patients who had sustained a Lisfranc injury between 2013 and 2022 across two trauma centres within the United Kingdom who underwent surgery. Pre-operative XR and CT images were reviewed independently by 2 reviewers to identify the presence of associated fractures. Results. A total of 175 patients were included. Our assessment identified that XR images significantly under-diagnosed all metatarsal and midfoot fractures. The largest discrepancies between XR and CT in their rates of detection were in fractures of the cuboid (5.7% vs 28%, p<0.001), medial cuneiform (20% vs 51%, p=0.008), lateral cuneiform (4% vs 36%, p=0.113), second metatarsal (57% vs 82%, p<0.001), third metatarsal (37% vs 61%, p<0.001) and fourth metatarsal (26% vs 43%, p<0.001). As compared to CT, the sensitivity of XR was low. The lowest sensitivity for identification however was lateral foot injuries, specifically fractures of the lateral cuneiform (sensitivity 7.94%, specificity 97.3%), cuboid (sensitivity 18.37%, specificity 99.21%), fourth (sensitivity 46.7%, specificity 89.80%) and fifth metatarsal (sensitivity 45.00%, specificity 96.10%). Conclusion. From our analysis, we can determine that XR significantly under-diagnoses associated injuries in patient sustaining an unstable Lisfranc injury, with lateral foot injuries being the worst identified. We advised the use of CT imaging in all cases for appropriate surgical planning


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 2 - 2
1 Apr 2018
Jo S Lee S Kang S
Full Access

Introduction. The correct anteversion of the acetabular cup is critical to achieve optimal outcome after total hip arthroplasty. While number of method has been described to measure the anteversion in plane anteroposterior and lateral radiograph, it is still controversial which method provides best anteversion measurement. While many of the previous studies used CT scan to validate the anteversion measured in plane anteroposterior radiograph, this may cause potential bias as the anteversion measured in CT scan reflects true anteversion while the anteversion measurement methods in plane radiograph are design to measure the planar anteversion. Thus, in the current study, we tried to find the optimal anteversion measurement method free from the previously described bias. Material and method. Custom made cup model was developed which enables change in anteversion and inclination. Simple radiograph was taken with the cup in 10° to 70° degree of inclination at 10° increments and for each inclination angle, anteversion was corrected from 0° to 30° at 5° increments. The radiograph was taken with the beam directed at the center of the cup (mimicking hip centered anteroposterior radiograph) and at 9cm medial to the cup (mimicking pelvis anteroposterior radiograph). The measurements were done by two orthopaedic surgeons using methods described by 1) Pradhan et al, 2) Lewinak et al, 3) Widmer et al, and 4) Liaw et al. For each measurements, the anteversion were compared with the actual anteversion. Result. Interoverver correlation (kappa value) were high in all measurements ranging 0.988 to 0.998. Regardless of how the radiograph was taken, Pradhan method was the most accurate measurement method showing difference of 2.17° ± 1.69° and −2.5° ± 1.93° compare to the actual anteversion respectively for hip centered radiograph and pelvis anteroposterior radiograph. The Widmer method showed the least accuracy (pelvis AP : −6.75° ± 4.62°, hip centered AP : −14.84° ± 4.36°). However, when the anteversion were measured in the safe zone with the inclination in 30° to 50° Liaw's method in hip centered radiograph showed the highest accuracy (1.63° ± 1.4°). Conclusion. The study indicates that the Pradhan's method may provide the most accurate anteversion measurement. However, with the hip in 30° to 50° inclination, Liaw's method measured from hip centred radiograph will provide most accurate anteversion measurement


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 7 - 7
1 Oct 2019
Ransone M Fehring K Fehring TK
Full Access

Introduction. Patients with abnormal spinopelvic mobility are at increased risk for hip instability. Measuring the change in sacral slope (ΔSS) with standing and seated lateral radiographs is commonly used to determine spinopelvic mobility pre-operatively. Sacral slope should decrease at least 10 degrees to demonstrate adequate accommodation. Accommodation of <10 deg necessitates acetabular component position change or use of a dual mobility implant. There is potential for different ΔSS measurements in the same patient based on sitting posture. Methods. 78 patients who underwent THA were reviewed to quantify the variability in pre-operative spinopelvic mobility when two different seated positions (relaxed sitting v. pre-rise sitting) were used in the same patient. Results. 34 patients had standardized pre-rise sitting x-rays, while 44 patients had standardized relaxed sitting x-rays. Of the 44 patients with relaxed sitting x-rays, the mean ΔSS (ΔrSS) was 20.4 degrees. No patients exhibited an increase in sacral slope when sitting (ie; reverse accommodation). Of the 34 patients with pre-rise sitting x-rays, the mean pre-rise sit-stand change (ΔprSS) was only 1.85 degrees with 47% (16/34) showing reverse accommodation, actually increasing the seated sacral slope compared to standing sacral slope. 18 patients had both pre-rise and relaxed sitting x-rays. In patients with both seated x-rays, the mean relaxed sit-stand change in sacral slope (ΔrSS) was 18.1 ± 6.1 degrees and only 3.0 ± 10.5 degrees for pre-rise sit-stand (ΔprSS), with a mean ΔSS difference of the 15.1 degrees (p <0.0001). Conclusion. A 15 degrees error could be made in pre-operative planning depending on the seated posture of the patient. Since decisions on component position or use of dual-mobility are made on pre-operative lateral sit-stand radiographs, postural standardization is critical. The relaxed seated radiograph is the preferred posture at the time of the seated lateral radiograph. For any tables or figures, please contact the authors directly