header advert
Results 1 - 20 of 152
Results per page:
Bone & Joint Research
Vol. 11, Issue 11 | Pages 787 - 802
1 Nov 2022
Sebastian S Tandberg F Liu Y Raina DB Tägil M Collin M Lidgren L

Aims. There is a lack of biomaterial-based carriers for the local delivery of rifampicin (RIF), one of the cornerstone second defence antibiotics for bone infections. RIF is also known for causing rapid development of antibiotic resistance when given as monotherapy. This in vitro study evaluated a clinically used biphasic calcium sulphate/hydroxyapatite (CaS/HA) biomaterial as a carrier for dual delivery of RIF with vancomycin (VAN) or gentamicin (GEN). Methods. The CaS/HA composites containing RIF/GEN/VAN, either alone or in combination, were first prepared and their injectability, setting time, and antibiotic elution profiles were assessed. Using a continuous disk diffusion assay, the antibacterial behaviour of the material was tested on both planktonic and biofilm-embedded forms of standard and clinical strains of Staphylococcus aureus for 28 days. Development of bacterial resistance to RIF was determined by exposing the biofilm-embedded bacteria continuously to released fractions of antibiotics from CaS/HA-antibiotic composites. Results. Following the addition of RIF to CaS/HA-VAN/GEN, adequate injectability and setting of the CaS/HA composites were noted. Sustained release of RIF above the minimum inhibitory concentrations of S. aureus was observed until study endpoint (day 35). Only combinations of CaS/HA-VAN/GEN + RIF exhibited antibacterial and antibiofilm effects yielding no viable bacteria at study endpoint. The S. aureus strains developed resistance to RIF when biofilms were subjected to CaS/HA-RIF alone but not with CaS/HA-VAN/GEN + RIF. Conclusion. Our in vitro results indicate that biphasic CaS/HA loaded with VAN or GEN could be used as a carrier for RIF for local delivery in clinically demanding bone infections. Cite this article: Bone Joint Res 2022;11(11):787–802


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 66 - 66
11 Apr 2023
Sebastian S Collin M Liu Y Raina D Tägil M Lidgren L
Full Access

There is a lack of carriers for the local delivery of rifampicin (RIF), one of the cornerstone second defence antibiotic for Staphylococcus aureus deep bone infections (DBIs). RIF is also associated with systemic side effects, and known for causing rapid development of antibiotic resistance when given as monotherapy. We evaluated a clinically usedbi-phasic calcium sulphate/hydroxyapatite (CaS/HA) biomaterial as a carrier for dual delivery of RIF with vancomycin (VAN) or gentamicin (GEN). It was hypothesized that this combined approach could provide improved biofilm eradication and prevent the development of RIF resistance. Methods: 1) Biofilm eradication: Using a modified crystal violet staining biofilm quantification method, the antibiotics released at different time points (Day 1, 3, 7, 14, 21, 28 and 35) from the hemispherical pellets of CaS/HA(500 mg)-VAN (24.57 mg) / GEN (10.35 mg) composites with or without RIF (8.11 mg) were tested for their ability to disrupt the preformed 48-h old biofilms of S. aureus ATCC 25923, and S. aureus clinical strain P-3 in 96-well microtitre plate. For each tested group of antibiotic fractions, five separate wells were used (n=5). 2) Testing for resistance development: Similar to the method mentioned above the 48-h biofilm embeded bacteria exposed to antibiotic fractions from different time points continuously for 7 days. The biofilms remained were then tested for RIF resistant strains of bacteria. Overall, there was clear antibiofilm biofilm activity observed with CaS/HA-VAN/GEN+RIF combinations compared with CaS/HA-VAN/GEN alone. The S. aureus strains developed resistance to RIF when biofilms were subjected to CaS/HA-RIF alone but not with combinations of CaS/HA-VAN/GEN+RIF. Enhanced antibiofilm effects without development of RIF resistance indicates that biphasic CaS/HA loaded with VAN or GEN could be used as a carrier for RIF for additional local delivery in clinically demanding DBIs. Acknowledgement: We deeply acknowledge the Royal Fysiographic Society of Lund, Landshövding Per Westlings Minnesfond and the Stina and Gunnar Wiberg fond for financial support


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 39 - 39
1 Jun 2023
Chandra A Trompeter A
Full Access

Atypical femoral fracture non-union (AFFNU) is both, rare (3–5 per 1000 proximal femur fractures) and difficult to treat. Lack of standardised guidelines leads to a variability in fixation constructs, use of bone grafting and restricted weight bearing protocols, which are not evidence based. We hypothesised that there is no change in union rates without the use of bone grafting and immediate weight bearing post-operatively does not lead to increased complications.

Materials & Methods

A retrospective review of all consecutively treated AFFNU cases between March 2015 to December 2019 was carried out. 9 patients with a mean age of 63.87 years and M:F ratio of 7:2 met the inclusion criteria. Primary outcome variable was radiographic union at 12 months after revision surgery. All surgeries were carried out by a single surgeon. Fixation construct, neck-shaft angle, use of bone graft and immediate postoperative weight bearing protocols were recorded.

Results

Radiographic union was achieved in 7 of 9 patients (78%) after first revision surgery. 1 patient achieved union after 2nd revision surgery and 1 patient died in the early post-operative period due to pulmonary embolism. No bone grafting was used in any of the patients and weight-bearing as tolerated was allowed from the first post-operative day. The mean neck-shaft angle after non-union surgery was 136 degrees.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 40 - 40
1 Jun 2023
Al-Omar H Patel K Lahoti O
Full Access

Introduction

Angular deformities of the distal femur can be corrected by opening, closing and neutral wedge techniques. Opening wedge (OW) and closing wedge (CW) are popular and well described in the literature. CW and OW techniques lead to leg length difference whereas the advantage of neutral wedge (NW) technique has several unique advantages. NW technique maintains limb length, wedge taken from the closing side is utilised on the opening side and since the angular correction is only half of the measured wedge on either side, translation of distal fragment is minimum. Leg lengths are not altered with this technique hence a useful technique in large deformities. We found no reports of clinical outcomes using NW technique. We present a technique of performing external fixator assisted NW correction of large valgus and varus deformities of distal femur and dual plating and discuss the results.

Materials & Methods

We have treated 20 (22 limbs – 2 patients requiring staged bilateral corrections) patients for distal femoral varus and valgus deformities with CWDFO between 2019 and 2022. Out of these 4 patients (5 limbs) requiring large corrections of distal femoral angular deformities were treated with Neutral Wedge (NW) technique. 3 patients (four limbs) had distal femoral valgus deformity and one distal femoral varus deformity. Indication for NW technique is an angular deformity (varus or valgus of distal femur) requiring > 12 mm opening/closing wedge correction. We approached the closing side first and marked out the half of the calculated wedge with K – wires in a uniplanar fashion. Then an external fixator with two Schanz screws is applied on the opposite side, inserting the distal screw parallel to the articular surface and the proximal screw 6–7 cm proximal to the first pin and at right angles to the femoral shaft mechanical axis. Then the measured wedge is removed and carefully saved. External fixator is now used to close the wedge and over correct, creating an appropriate opening wedge on the opposite side. A Tomofix (Depuoy Synthes) plate is applied on the closing side with two screws proximal to osteotomy and two distally (to be completed later). Next the osteotomy on the opposite side is exposed, the graft is inserted. mLDFA is measured under image intensifier to confirm satisfactory correction. Closing wedge side fixation is then completed followed by fixation of opposite side with a Tomofix or a locking plate.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 17 - 17
1 Jun 2023
Hoellwarth J Oomatia A Al Muderis M
Full Access

Introduction

Transfemoral osseointegration (TFOI) for amputees has substantial literature proving superior quality of life and mobility versus a socketed prosthesis. Some amputees have hip arthritis that would be relieved by a total hip replacement (THR). No other group has reported performing a THR in association with TFOI (THR+TFOI). We report the outcomes of eight patients who had THR+TFOI, followed for an average 5.2 years.

Materials & Methods

Our osseointegration registry was retrospectively reviewed to identify all patients who had TFOI and also had THR, performed at least two years prior. Six patients had TFOI then THR, one simultaneous, one THR then TFOI. All constructs were in continuity from hip to prosthetic limb. Outcomes were: complications prompting surgical intervention, and changes in subjective hip pain, K-level, daily prosthesis wear hours, Questionnaire for Persons with a Transfemoral Amputation (QTFA), and Short Form 36 (SF36). All patients had clinical follow-up, but one patient did not have complete mobility and quality of life survey data at both time periods.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 2 - 2
1 Jun 2023
Tay KS Langit M Muir R Moulder E Sharma H
Full Access

Introduction

Circular frames for ankle fusion are usually reserved for complex clinical scenarios. Current literature is heterogenous and difficult to interpret. We aimed to study the indications and outcomes of this procedure in detail.

Materials & Methods

A retrospective cohort study was performed based on a prospective database of frame surgeries performed in a tertiary institution. Inclusion criteria were patients undergoing complex ankle fusion with circular frames between 2005 and 2020, with a minimum 12-month follow up. Data were collected on patient demographics, surgical indications, comorbidities, surgical procedures, external fixator time (EFT), length of stay (LOS), radiological and clinical outcomes, and adverse events. Factors influencing radiological and clinical outcomes were analysed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 4 - 4
1 Jun 2023
Langit M Tay K Al-Omar HK Muir R Bates J Chuo CB Barlow G Sharma H
Full Access

Introduction

Wide, tumor-like resection for chronic osteomyelitis (COM), a standard practice previously, has been challenged recently with adequate, local debridement. This paper reviews the evolution of surgical debridement for long bone osteomyelitis, and presents the outcome of adequate debridement in a tertiary bone infection unit.

Materials & Methods

Retrospective review of records from 2014 to 2020 of patients with long bone osteomyelitis. All records were searched electronically and imaging reviewed. All patients were managed by Multidisciplinary Infection Team protocol.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 6 - 6
1 Jun 2023
Watts D Bye D Nelson D Chase H Nunney I Marshall T Sanghrajka A
Full Access

Introduction

Derotation osteotomies are commonly performed in paediatric orthopaedic and limb reconstruction practice. The purpose of this study was to determine whether the use of a digital inclinometer significantly improves the accuracy in attaining the desired correction.

Materials & Methods

We designed an electronic survey regarding derotation femoral osteotomy (DFO) including methods of intra-operative angular correction assessment and acceptable margins of error for correction. This was distributed to 28 paediatric orthopaedic surgeons in our region. A DFO model was created, using an anatomic sawbone with foam covering. 8 orthopaedic surgeons each performed two 30-degree DFOs, one using K-wires and visual estimation (VE), and the other using a Digital Inclinometer (DI). Two radiologists reported pre and post procedure rotational profile CT scans to assess the achieved rotational correction.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 11 - 11
1 Jun 2023
Doherty C McKee CM Foster A
Full Access

Introduction

Non-union is an unfortunate outcome of the fracture healing process for some patients; with an estimated annual incidence of 17.4- 18.9 per 100,00. The management of these patients depicts a significant clinical challenge for surgeons and financial burden to health services. External ultrasound stimulation devices (ExogenTM) have been highlighted as a novel non invasive therapy to achieve union in cases of delayed and non-union. The aim of the current study was to assess the rate of union in patients using ExogenTM therapy for delayed fracture union in a district general hospital.

Materials & Methods

This is a single centre retrospective continuous cohort study. Patients were identified from a prospective database of all patients prescribed ExogenTM therapy between June 2013- September 2021 in a district general hospital. Patient data was collected retrospectively using electronic patient records. Fracture union was assessed both clinically and radiographically and recorded in patient records. Failure of treatment was defined as progression to operative treatment due to lack of progression with ultrasound therapy or established asymptomatic non-union. Patient were excluded from the study if ExogenTM therapy was prescribed within 6 weeks of injury.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 43 - 43
1 Jun 2023
Mackey R Robinson M Mullan C Breen N Lewis H McMullan M Ogonda L
Full Access

Introduction

The purpose of this study is to evaluate the radiological and clinical outcomes in Northern Ireland of free vascularised fibular bone grafting for the treatment of humeral bone loss secondary to osteomyelitis. Upper limb skeletal bone loss due to osteomyelitis is a devastating and challenging complication to manage for both surgeon and patient. Patients can be left with life altering disability and functional impairment. This limb threatening complication raises the question of salvage versus amputation and the associated risk and benefits of each. Free vascularised fibula grafting is a recognised treatment option for large skeletal defects in long bones but is not without significant risk. The benefit of vascularised over non-vascularised fibula grafts include preservation of blood supply lending itself to improved remodeling and osteointegration.

Materials & Methods

Sixteen patients in Northern Ireland had free vascularised fibula grafting. Inclusion criteria included grafting to humeral defects secondary to osteomyelitis. Six patients were included in this study. Patients were contacted to complete DASH (Disabilities of the Arm, Shoulder and Hand) questionnaires as our primary outcome measure. Secondary outcome measures included radiological evaluation of osteointegration and associated operative complications. Complications were assessed via review of Electronic Care Record outpatient and in-patient documents.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 46 - 46
1 Jun 2023
Fernandes R Farid M Desai S McFadyen I Maamoun W Huq S
Full Access

Introduction

Fracture related infection (FRI) is a challenging complication to manage in an orthoplastic setting. Consensus guidelines have been created to standardise the diagnosis of FRI and comprise confirmatory and suggestive criteria. In this study, the aim is to assess the diagnostic criteria and management of FRI with a particular focus on soft tissue reconstruction.

Materials & Methods

A retrospective study to identify the outcomes of FRI in the lower limb over a five year period at a Major Trauma Centre. Fracture specific information that was analysed includes: open versus closed, fractured bone(s) and site, initial fracture management, method of diagnosis and soft tissue management.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 47 - 47
1 Jun 2023
Wilson G Prior C
Full Access

Introduction

The purpose of this study was to analyse the efficacy and complications associated with the use of Calcium Sulphate synthetic bone graft in a paediatric population. There are no published articles on the use in children.

Materials & Methods

A retrospective review was undertaken of the notes, microbiology, and X-Rays of 17 cases (in 15 patients) of calcium sulphate use in paediatric patients. As well as patient demographic data, data collected included indication, use of additional agents (antibiotics), return to theatre, and wound complications. Major complications were also assessed for.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 13 - 13
23 Apr 2024
Lister J McDaid C Hewitt C Leggett H James S Sharma H
Full Access

Introduction

There are concerns that patient-reported outcome measures (PROMs) currently used for adults requiring, undergoing or after undergoing lower limb reconstruction (LLR) are not adequately capturing the range of experiences important to these patients. The ‘Patient-Reported Outcome Measure for Lower Limb Reconstruction’ (PROLLIT) study developed a conceptual framework of outcomes identified as important and relevant by adult LLR patients. This review explored whether existing PROMs address these outcomes, and exhibit content validity in this population.

Materials & Methods

A range of key PROMs was selected (n=32). Systematic and hand-searches were employed to find studies assessing content validity of these PROMs in the adult LLR population, along with PROM content and development information. A systematic review of content validity of the measures was carried out following ‘COnsensus-based Standards for the selection of health Measurement Instruments’ (COSMIN) guidance, alongside conceptual mapping of the content of the PROMs against the PROLLIT conceptual framework.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 6 - 6
23 Apr 2024
Mistry D Rahman U Khatri C Carlos W Stephens A Riemer B Ward J
Full Access

Introduction

Continuous compression implants (CCIs) are small memory alloy bone staples that can provide continuous compression across a fracture site, which change shape due to temperature changes. Reviews of CCIs in orthopaedics have documented their use in mainly foot and ankle surgery, with very limited descriptions in trauma. They could be beneficial in the management of complex or open injuries due to their low profile and quick insertion time. The aim of this case series were to clarify the use of CCIs in modern day limb reconstruction practice.

Materials & Methods

This was a single centred study looking retrospectively at prospective data for patients who were treated for an acute fracture or non-union with a CCI between September 2019 and May 2023. Primary outcome was to determine the function and indication of the CCI as judged retrospectively and secondary outcomes investigated unplanned returns to theatre for infection or CCI failure.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 17 - 17
23 Apr 2024
Mackarel C Tunbridge R
Full Access

Introduction

Sheffield Children's Hospital specialises in limb lengthening for children. Soft tissue contracture and loss of range of motion at the knee and ankle are common complications. This review aims to look at therapeutic techniques used by the therapy team to manage these issues.

Materials & Methods

A retrospective case review of therapy notes was performed of femoral and tibial lengthening's over the last 3 years. Included were children having long bone lengthening with an iIntramedullary nail, circular frame or mono-lateral rail. Patients excluded were any external fixators crossing the knee/ankle joints.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 29 - 29
23 Apr 2024
Ahmed T Upadhyay P Menawy ZE Kumar V Jayadeep J Chappell M Siddique A Shoaib A
Full Access

Introduction

Knee dislocations, vascular injuries and floating knee injuries can be initially managed by a external fixator. Fixator design constructs include the AO pattern and the Diamond pattern. However, these traditional constructs do not adhere to basic principles of external fixation. The Manchester pattern knee-spanning external fixator is a new construct pattern, which uses beam loading and multiplanar fixation. There is no data on any construct pattern. This study compares the stability of these designs.

Materials & Methods

Hoffman III (Stryker, USA) external fixation constructs were applied to articulated models of the lower limb, spanning the knee with a diamond pattern and a Manchester pattern. The stiffness was loaded both statically and cyclically with a Bose 3510 Electroforce mechanical testing jig (TA Instruments). A ramp to load test was performed initially and cyclical loading for measurement of stiffness over the test period. The results were analysed with a paired t-test and ANOVA.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 27 - 27
23 Apr 2024
Howard A Harwood P Benton A Merrel C Culmer P Bolton W Stewart T
Full Access

Introduction

Ilizarov fixators are reliant on tensioned fine wires for stability. The tension in the wires is generated using specific tensioning devices. Loss of wire tension over time may lead of loss a stability and complications. A series of in vitro experiments were undertaken to explore wire tensioner accuracy, the impact of fixation bolt torque and initial tension on loss of tension in ilizarov constructs under static and dynamic loads.

Materials & Methods

Medical grade materials were applied to a synthetic bone analogue using surgical instruments in all experiments. Bolt torque was fixed at 6, 10 or 14 Nm using a torque limiting wrench. Wire tension was assessed using a strain measurement bridge. Wires were tensioned to 90, 110 and 130kg as measured by a commercial dynamometric tensioner. Static and dynamic testing was undertaken using an instron testing machine. Cyclical loads from 50–750N were applied for 5000 cycles.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 8 - 8
23 Apr 2024
Senan R Linkogel W Marwan Y Staniland T Sharma H
Full Access

Introduction

Knee arthrodesis is a useful limb salvage technique to maintain function in patients with complex and infected total knee arthroplasties (TKA). There are a number of commonly used external fixators, but no consensus on which of these are optimal.

The aim of this study was to synthesise the current literature to guide clinical decision making and improve patient outcomes. We systematically review the literature to compare outcomes of external fixators in arthrodesis following infected TKA.

Materials & Methods

A systematic review of the literature of primary research articles investigating the use of external fixators for knee arthrodesis after an infected TKA was conducted. Relevant articles were identified with a search strategy on online databases (EMBASE and Medline) and reviewed by two independent reviewers.

Clinical outcome measures were independently extracted by two reviewers which included union rate, infection eradication rate, complication rate, time to fusion, and time in frame.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 15 - 15
23 Apr 2024
Sharkey S Round J Britten S
Full Access

Introduction

Compartment syndrome can be a life changing consequence of injury to a limb. If not diagnosed and treated early it can lead to permanent disability. Neurovascular observations done on the ward by nursing staff, are often our early warning system to those developing compartment syndrome. But are these adequate for detecting the early signs of compartment syndrome? Our aim was to compare the quality and variability of charts across the UK major trauma network.

Materials & Methods

All major trauma centres in England and Scotland were invited to supply a copy of the neurovascular chart routinely used. We assessed how such charts record relevant information. Specific primary data points included were pain scores, analgesia requirements, pain on passive stretch and decreased sensation in the first web space specifically. As secondary objectives, we assessed how late signs were recorded, whether clear instructions were included, quantitative scores and the use of regional blocks recorded.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 36 - 36
1 Jun 2023
Rashid L Trompeter A Saw A
Full Access

Introduction

Osteotomy is a key step in distraction osteogenesis. Various techniques of osteotomy have been described with its own benefits and pitfalls. Percutaneous osteotomy using multiple drill holes is one of the most widely used osteotomy techniques. It still remains a challenge however to keep the drill holes aligned prior to the osteotomy. Moreover, the efficacy of percutaneous irrigation practice to keep the temperature low during drilling with this technique is also debatable. With an aim to overcome these challenges, we are introducing a device called the Double Barrel Drill Sleeve (DBDS) to perform percutaneous osteotomies. We attempted to compare this method to the conventional multiple drill holes technique using laboratory experiments and clinical data.

Materials & Methods

DBDS has two adjacent parallel barrels that can fit 3.2 to 3.5 mm diameter drill bits. It has a guide member at the drilling end that can be inserted through a pre drilled hole at the near and far cortices of a bone. This provides a constant rotating point for drilling of holes through the barrels. An osteotomy simulation was performed to compare percutaneous drilling with DBDS vis-a-vis a conventional single drill sleeve (SDS) by qualified orthopaedic surgeons, mainly to assess the drilling patterns of both techniques. Percutaneous drilling was done on PVC pipes wrapped in thick sponge to simulate tubular bone with surrounding soft tissue. We also assessed the effect of indirect irrigation on temperature during drilling using the DBDS against a control group on a cadaveric bone model. Ultimately we reviewed our patients who had undergone osteotomy for distraction osteogenesis with DBDS and the conventional technique, and compared their outcomes.