Background. RHF nail is an important tool for simultaneous ankle and subtalar joint stabilisation +/− fusion. Straight and curved RHF nails are available to use, but both seem to endanger plantar structures, especially the lateral plantar artery and nerve and Baxter's nerve. There is a paucity of literature on the structures at risk with a straight RHF nail inserted along a line bisecting the heel pad and the second toe (after Stephenson et al). In this study, plantar structures ‘at risk’ were studied in relation to a straight nail inserted as above. Methods. Re-creating real-life conditions and strictly following the recommended surgical technique with regards to the incision and guide-wire placement, we inserted an Orthosolutions Oxbridge nail into the tibia across the ankle and subtalar joints in 6 cadaveric specimens. Tissue flaps were then raised to expose the heel plantar structures and studied their relation to the inserted nail. Results. The medial plantar artery and nerve were always more than 10mm away from the medial edge of the nail, while the Baxter nerve was a mean 14mm behind. The lateral plantar nerve was a mean 7mm medial to the nail, while the artery was a mean 2.3mm away with macroscopic injury in one specimen. The other structures ‘at risk’ were the plantar fascia and small foot muscles. Conclusion. Lateral plantar artery and nerve are the most vulnerable structures during straight RHF nailing. The risk to heel plantar structures could be mitigated by making incisions longer, blunt dissection down to bone, meticulous retraction of soft tissues and placement of the protection sleeve down to bone to prevent the entrapment of plantar structures during guide-wire placement,
This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days. We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH).Aims
Methods
The aim of this study was to establish a reliable method for producing 3D reconstruction of sonographic callus. A cohort of ten closed tibial shaft fractures managed with intramedullary nailing underwent ultrasound scanning at two, six, and 12 weeks post-surgery. Ultrasound capture was performed using infrared tracking technology to map each image to a 3D lattice. Using echo intensity, semi-automated mapping was performed to produce an anatomical 3D representation of the fracture site. Two reviewers independently performed 3D reconstructions and kappa coefficient was used to determine agreement. A further validation study was undertaken with ten reviewers to estimate the clinical application of this imaging technique using the intraclass correlation coefficient (ICC).Aims
Methods
Limb-lengthening nails have largely replaced external fixation in limb-lengthening and reconstructive surgery. However, the adverse events and high prevalence of radiological changes recently noted with the STRYDE lengthening nail have raised concerns about the use of internal lengthening nails. The aim of this study was to compare the prevalence of radiological bone abnormalities between STRYDE, PRECICE, and FITBONE nails prior to nail removal. This was a retrospective case series from three centres. Patients were included if they had either of the three limb-lengthening nails (STYDE, PRECICE, or FITBONE) removed. Standard orthogonal radiographs immediately prior to nail removal were examined for bone abnormalities at the junction of the telescoping nail parts.Aims
Methods
The study objective was to prospectively assess clinical outcomes for a pilot cohort of tibial shaft fractures treated with a new tibial nailing system that produces controlled axial interfragmentary micromotion. The hypothesis was that axial micromotion enhances fracture healing compared to static interlocking. Patients were treated in a single level I trauma centre over a 2.5-year period. Group allocation was not randomized; both the micromotion nail and standard-of-care static locking nails (control group) were commercially available and selected at the discretion of the treating surgeons. Injury risk levels were quantified using the Nonunion Risk Determination (NURD) score. Radiological healing was assessed until 24 weeks or clinical union. Low-dose CT scans were acquired at 12 weeks and virtual mechanical testing was performed to objectively assess structural bone healing.Aims
Methods
Tibiotalocalcaneal (TTC) fusion is used to treat a variety of conditions affecting the ankle and subtalar joint, including osteoarthritis (OA), Charcot arthropathy, avascular necrosis (AVN) of the talus, failed total ankle arthroplasty, and severe deformity. The prevalence of postoperative complications remains high due to the complexity of hindfoot disease seen in these patients. The aim of this study was to analyze the relationship between preoperative conditions and postoperative complications in order to predict the outcome following primary TTC fusion. We retrospectively reviewed the medical records of 101 patients who underwent TTC fusion at the same institution between 2011 and 2019. Risk ratios (RRs) associated with age, sex, diabetes, cardiovascular disease, smoking, preoperative ankle deformity, and the use of bone graft during surgery were related to the postoperative complications. We determined from these data which pre- and perioperative factors significantly affected the outcome.Aims
Methods
Aim. Post traumatic distal tibia osteomyelitis (DTOM) with an upper ankle joint involvement is a serious complication after primary osteosynthesis and can be a nightmare for the patient and the surgeon as well. Our aim was to identify mayor complications during treatment and to find the way to prevent or treat them. Method. It is a retrospective analysis of eight patients with DTOM and an upper ankle joint involvement treated in our institution from 2012 to 2018. The average size of a bone defect after a debridement was 9 centimeters (4–15). Patients were treated in two stages. First stage was segmental bone resection, external fixation and soft tissue envelope reconstruction if necessary. At second stage a distraction frame was applied and proximal corticotomy performed. In all but one case a circular frame was used. Results. We have had one major intra-operative complication, an injury of arteria tibialis posterior during the corticotomy procedure. Except in one patient we did not observe major problems with pin-track infections. Despite bone-grafting in all patients, we observed three nonunions of docking site. We treated them by external fixator in two and retrograde intramedullar nail in one case. In two patient the distraction callus was weak. We had to bone graft and secure the callus with a plate in one and use a retrograde
Different criteria for assessing the reduction quality of trochanteric fractures have been reported. The Baumgaertner reduction quality criteria (BRQC) are relatively common and the Chang reduction quality criteria (CRQC) are relatively new. The objectives of the current study were to compare the reliability of the BRQC and CRQC in predicting mechanical complications and to investigate the clinical implications of the CRQC. A total of 168 patients were assessed in a retrospective observational study. Clinical information including age, sex, fracture side, American Society of Anesthesiologists (ASA) classification, tip-apex distance (TAD), fracture classification, reduction quality, blade position, BRQC, CRQC, bone quality, and the occurrence of mechanical complications were used in the statistical analysis.Objectives
Methods
Type IIIB open tibial fractures are devastating high-energy injuries. At initial debridement, the surgeon will often be faced with large bone fragments with tenuous, if any, soft-tissue attachments. Conventionally these are discarded to avoid infection. We aimed to determine if orthoplastic reconstruction using mechanically relevant devitalized bone (ORDB) was associated with an increased infection rate in type IIIB open tibial shaft fractures. This was a consecutive cohort study of 113 patients, who had sustained type IIIB fractures of the tibia following blunt trauma, over a four-year period in a level 1 trauma centre. The median age was 44.3 years (interquartile range (IQR) 28.1 to 65.9) with a median follow-up of 1.7 years (IQR 1.2 to 2.1). There were 73 male patients and 40 female patients. The primary outcome measures were deep infection rate and number of operations. The secondary outcomes were nonunion and flap failure.Aims
Patient and Methods
The aim of this study was to review the current evidence and future application for the role of diagnostic and therapeutic ultrasound in fracture management. A review of relevant literature was undertaken, including articles indexed in PubMed with keywords “ultrasound” or “sonography” combined with “diagnosis”, “fracture healing”, “impaired fracture healing”, “nonunion”, “microbiology”, and “fracture-related infection”.Objectives
Methods
Background. In a systematic review of 1125 distal tibia fractures treated with an intramedullary nail, the reported incidence of malalignment was 14%. The purpose of our study is to assess whether the addition of blocking screws during intramedullary nailing of a distal tibia fracture improved radiological outcomes. As a secondary outcome, the time to radiographic union was compared to see if a more rigid bone-implant construct had an effect on healing. Methods. We searched computerised records at a UK level 1 major trauma centre. The joint alignment was measured on the immediate post-operative radiograph and compared to the most recent radiograph. We used a difference of 2 degrees to indicate a progressive deformity and a RUST score greater or equal to 10, to indicate radiographic fracture union. Results. Twenty-seven patients were included. Nineteen patients had no blocking screw and 8 patients had a blocking screw. Five patients had a difference in their coronal plane alignment of 2 degrees or more (3/5 had no blocking screw). The results were analysed and found to be not statistically significant (p=0.88). The addition of a blocking screw has also been shown not to have an effect on the time to union. Conclusion. We have changed our surgical practice. We use a 2.5mm blocking wire to aid in fracture reduction prior to
Hindfoot arthrodesis with retrograde intramedullary nailing has
been described as a surgical strategy to reconstruct deformities
of the ankle and hindfoot in patients with Charcot arthropathy.
This study presents case series of Charcot arthropathy patients
treated with two different retrograde intramedullary straight compression
nails in order to reconstruct the hindfoot and assess the results
over a mid-term follow-up. We performed a retrospective analysis of 18 consecutive patients
and 19 operated feet with Charcot arthropathy who underwent a hindfoot
arthrodesis using a retrograde intramedullary compression nail.
Patients were ten men and eight women with a mean age of 63.43 years
(38.5 to 79.8). We report the rate of limb salvage, complications requiring
additional surgery, and fusion rate in both groups. The mean duration
of follow-up was 46.36 months (37 to 70).Aims
Patients and Methods
The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) with the immediate post-operative radiograph available for comparison. A total of 15 radiographs of tibial shaft fractures treated by intramedullary nailing (IM) were scored by three observers using the RUST system. Following discussion on how the criteria of the RUST system should be implemented, 45 sets (i.e. AP and lateral) of radiographs of IM nailed tibial fractures were scored by five observers. Finally, these 45 sets of radiographs were rescored with the baseline post-operative radiograph available for comparison.Objectives
Methods
The aim of this study was to identify risk factors for the failure
of exchange nailing in nonunion of tibial diaphyseal fractures. A cohort of 102 tibial diaphyseal nonunions in 101 patients with
a mean age of 36.9 years (15 to 74) were treated between January
1992 and December 2012 by exchange nailing. Of which 33 (32%) were
initially open injuries. The median time from primary fixation to
exchange nailing was 6.5 months (interquartile range (IQR) 4.3 to
9.8 months). The main outcome measures were union, number of secondary fixation
procedures required to achieve union and time to union. Univariate analysis and multiple regression were used to identify
risk factors for failure to achieve union. Aims
Patients and Methods
Fractures of the tibial shaft are common injuries,
but there are no long-term outcome data in the era of increased surgical
management. The aim of this prospective study was to assess the
clinical and functional outcome of this injury at 12 to 22 years.
Secondary aims were to determine the short- and long-term mortality,
and if there were any predictors of clinical or functional outcome
or mortality. From a prospective trauma database of 1502 tibial
shaft fractures in 1474 consecutive adult patients, we identified
a cohort of 1431 tibial diaphyseal fractures in 1403 patients, who
fitted our inclusion criteria. There were 1024 men, and mean age
at injury was 40.6 years. Fractures were classified according to
the AO system, and open fractures graded after Gustilo and Anderson.
Requirement of fasciotomy, time to fracture union, complications,
incidence of knee and ankle pain at long-term follow-up, changes in
employment and the patients’ social deprivation status were recorded.
Function was assessed at 12 to 22 years post-injury using the Short
Musculoskeletal Function Assessment and short form-12 questionnaires.
Long-term functional outcome data was available for 568 of the surviving
patients, 389 were deceased and 346 were lost to follow-up. Most
fractures (90.7%, n = 1363) united without further intervention.
Fasciotomies were performed in 11.5% of patients; this did not correlate
with poorer functional outcome in the long term. Social deprivation
was associated with a higher incidence of injury but had no impact
on long-term function. The one-year mortality in those over 75 years
of age was 29 (42%). At long-term follow-up, pain and function scores
were good. However, 147 (26%) reported ongoing knee pain, 62 (10%)
reported ankle pain and 97 (17%) reported both. Such joint pain correlated
with poorer functional outcome. Cite this article:
High-quality randomised controlled trials (RCTs)
evaluating surgical therapies are fundamental to the delivery of
evidence-based orthopaedics. Orthopaedic clinical trials have unique
challenges; however, when these challenges are overcome, evidence
from trials can be definitive in its impact on surgical practice.
In this review, we highlight several issues that pose potential
challenges to orthopaedic investigators aiming to perform surgical randomised
controlled trials. We begin with a discussion on trial design issues,
including the ethics of sham surgery, the importance of sample size,
the need for patient-important outcomes, and overcoming expertise
bias. We then explore features surrounding the execution of surgical
randomised trials, including ethics review boards, the importance
of organisational frameworks, and obtaining adequate funding. Cite this article:
Using human cadaver specimens, we investigated
the role of supplementary fibular plating in the treatment of distal
tibial fractures using an intramedullary nail. Fibular plating is
thought to improve stability in these situations, but has been reported
to have increased soft-tissue complications and to impair union
of the fracture. We proposed that multidirectional locking screws
provide adequate stability, making additional fibular plating unnecessary.
A distal tibiofibular osteotomy model performed on matched fresh-frozen
lower limb specimens was stabilised with
Intramedullary nailing of tibial fractures is commonplace and freehand techniques are increasingly popular. The standard freehand method has the knee of the injured leg flexed over a radio-lucent bolster. This requires the imaging C-arm to swing from antero-posterior to lateral position several times. Furthermore, guide wire placement;
Purpose. There is no clear definition of a critical sized defect of the tibia. We defined it as a fracture gap at least one centimeter in length and involving over 50% of the cortical diameter. We explored if the presence of a critical-sized defect predicted reoperation, and which other factors predict reoperation in patients with the critical defect. The patient based outcomes of these patients were compared to patients without a critical defect. Method. Patients enrolled in the SPRINT trial with a critical sized defect were evaluated for secondary interventions to gain union. Other factors predicting the need for reoperation were studied. We also compared the patients with critical sized defects to the larger cohort of patients without a defect with respect to demographics, injury mechanism, fracture characteristics, and patient-based outcome. Results. Tibial diaphyseal defects of greater than or equal to one centimeter and >50% cortical circumference healed without additional surgery in 47% of cases. Fewer reoperations were required in patients treated with a