To report the development of the technique for minimally invasive lumbar decompression using robotic-assisted navigation. Robotic planning software was used to map out bone removal for a laminar decompression after registration of CT scan images of one cadaveric specimen. A specialized acorn-shaped bone removal robotic drill was used to complete a robotic lumbar laminectomy. Post-procedure advanced imaging was obtained to compare actual bony decompression to the surgical plan. After confirming accuracy of the technique, a minimally invasive robotic-assisted laminectomy was performed on one 72-year-old female patient with lumbar spinal stenosis. Postoperative advanced imaging was obtained to confirm the decompression.Aims
Methods
The February 2024 Spine Roundup. 360. looks at: Surgeon assessment of bone – any good?; Robotics reduces radiation exposure in some spinal surgery; Interbody fusion cage versus anterior lumbar interbody fusion with posterior instrumentation; Is robotic-assisted
Aims. The aim of this study was to assess the accuracy of
The February 2023 Spine Roundup. 360. looks at: S2AI screws: At what cost?; Just how good is spinal deformity surgery?; Is 80 years of age too late in the day for spine surgery?; Factors affecting the accuracy of
The use of 3D printing has become increasingly popular and has been widely used in orthopaedic surgery. There has been a trend towards an increasing number of publications in this field, but existing literature incorporates limited high-quality studies, and there is a lack of reports on outcomes. The aim of this study was to perform a scoping review with Level I evidence on the application and effectiveness of 3D printing. A literature search was performed in PubMed, Embase, and Web of Science databases. The keywords used for the search criteria were ((3d print*) OR (rapid prototyp*) OR (additive manufactur*)) AND (orthopaedic). The inclusion criteria were: 1) use of 3D printing in orthopaedics, 2) randomized controlled trials, and 3) studies with participants/patients. Risk of bias was assessed with Cochrane Collaboration Tool and PEDro Score. Pooled analysis was performed.Aims
Methods
To benchmark the radiation dose to patients during the course of treatment for a spinal deformity. Our radiation dose database identified 25,745 exposures of 6,017 children (under 18 years of age) and adults treated for a spinal deformity between 1 January 2008 and 31 December 2016. Patients were divided into surgical (974 patients) and non-surgical (5,043 patients) cohorts. We documented the number and doses of ionizing radiation imaging events (radiographs, CT scans, or intraoperative fluoroscopy) for each patient. All the doses for plain radiographs, CT scans, and intraoperative fluoroscopy were combined into a single effective dose by a medical physicist (milliSivert (mSv)).Aims
Methods
Continuous technical improvement in spinal surgical procedures, with the aim of enhancing patient outcomes, can be assisted by the deployment of advanced technologies including navigation, intraoperative CT imaging, and surgical robots. The latest generation of robotic surgical systems allows the simultaneous application of a range of digital features that provide the surgeon with an improved view of the surgical field, often through a narrow portal. There is emerging evidence that procedure-related complications and intraoperative blood loss can be reduced if the new technologies are used by appropriately trained surgeons. Acceptance of the role of surgical robots has increased in recent years among a number of surgical specialities including general surgery, neurosurgery, and orthopaedic surgeons performing major joint arthroplasty. However, ethical challenges have emerged with the rollout of these innovations, such as ensuring surgeon competence in the use of surgical robotics and avoiding financial conflicts of interest. Therefore, it is essential that trainees aspiring to become spinal surgeons as well as established spinal specialists should develop the necessary skills to use robotic technology safely and effectively and understand the ethical framework within which the technology is introduced. Traditional and more recently developed platforms exist to aid skill acquisition and surgical training which are described. The aim of this narrative review is to describe the role of surgical robotics in spinal surgery, describe measures of proficiency, and present the range of training platforms that institutions can use to ensure they employ confident spine surgeons adequately prepared for the era of robotic spinal surgery. Cite this article:
With the identification of literature shortfalls on the techniques employed in intraoperative navigated (ION) spinal surgery, we outline a number of measures which have been synthesised into a coherent operative technique. These include positioning, dissection, management of the reference frame, the grip, the angle of attack, the drill, the template, the pedicle screw, the wire, and navigated intrathecal analgesia. Optimizing techniques to improve accuracy allow an overall reduction of the repetition of the surgical steps with its associated productivity benefits including time, cost, radiation, and safety. Cite this article:
Intraoperative 3D navigation (ION) allows high accuracy to be achieved in spinal surgery, but poor workflow has prevented its widespread uptake. The technical demands on ION when used in patients with adolescent idiopathic scoliosis (AIS) are higher than for other more established indications. Lean principles have been applied to industry and to health care with good effects. While ensuring optimal accuracy of instrumentation and safety, the implementation of ION and its associated productivity was evaluated in this study for AIS surgery in order to enhance the workflow of this technique. The aim was to optimize the use of ION by the application of lean principles in AIS surgery. A total of 20 consecutive patients with AIS were treated with ION corrective spinal surgery. Both qualitative and quantitative analysis was performed with real-time modifications. Operating time, scan time, dose length product (measure of CT radiation exposure), use of fluoroscopy, the influence of the reference frame, blood loss, and neuromonitoring were assessed.Aims
Methods
Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics. A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers.Aims
Materials and Methods
The aim of this study was to compare the outcomes of surgery
using growing rods in patients with severe A review of a multicentre EOS database identified 107 children
with severe EOS (major curve ≥ 90°) treated with growing rods before
the age of ten years with a minimum follow-up of two years and three
or more lengthening procedures. From the same database, 107 matched
controls with moderate EOS were identified.Aims
Patients and Methods
Tuberculosis (TB) remains endemic in many parts
of the developing world and is increasingly seen in the developed world
due to migration. A total of 1.3 million people die annually from
the disease. Spinal TB is the most common musculoskeletal manifestation,
affecting about 1 to 2% of all cases of TB. The coexistence of HIV,
which is endemic in some regions, adds to the burden and the complexity
of management. This review discusses the epidemiology, clinical presentation,
diagnosis, impact of HIV and both the medical and surgical options
in the management of spinal TB. Cite this article:
We present an analysis of manual and computer-assisted preoperative
To introduce a new robot-assisted surgical system for spinal posterior fixation which called TiRobot, based on intraoperative three-dimensional images. TiRobot has three components: the planning and navigation system, optical tracking system and robotic arm system. By combining navigation and robot techniques, TiRobot can guide the screw trajectories for orthopedic surgeries. In this randomised controlled study approved by the Ethics Committee, 40 patients were involved and all has been fully informed and sign the informed consent. 17 patients were treated by free-hand fluoroscopy-guided surgery, and 23 patients were treated by robot-assisted spinal surgery. A total of 190 pedicle screws were implanted. The overall operation times were not different for both groups. None of the screws necessitated re-surgery for revised placement. In the robot-assisted group, assessment of pedicle screw accuracy showed that 102 of 102 screws (100%) were safely placed (<2 mm, category A+B). And mean deviation in entry point was 1.70 +/− 0.83mm, mean deviation in end point was 1.84 +/− 1.04mm. In the conventional freehand group, assessment of pedicle screw accuracy showed that 87 of 88 (98.9%) were safely placed (<2 mm, category A+B), 1 screw fall in category C, mean deviation in entry point was 3.73 +/− 2.28mm, mean deviation in end point was 4.11 +/− 2.31mm. This randomised controlled study verified that robot-assisted
Minimally invasive transforaminal lumbar interbody fusion (MITLIF)
has been well validated in overweight and obese patients who are
consequently subject to a higher radiation exposure. This prospective
multicentre study aimed to investigate the efficacy of a novel lumbar
localisation system for MITLIF in overweight patients. The initial study group consisted of 175 patients. After excluding
49 patients for various reasons, 126 patients were divided into
two groups. Those in Group A were treated using the localisation
system while those in Group B were treated by conventional means.
The primary outcomes were the effective radiation dosage to the
surgeon and the exposure time.Aims
Patients and Methods
Background. The overall incidence of neurological symptoms attributed to lumbar misplaced screws has been described to occur in 3.48% of patients undergoing surgery. These lumbar radicular neurological lesions are undetected with conventional intraoperative neurophysiological and radiological controls. The hypothesis of this study was that direct stimulation of the
Summary. Optimum position of pedicle screws can be determined preoperatively by CT based planning. We conducted a comparative study in order to analyse manually determined pedicle screw plans and those that were obtained automatically by a computer software and found an agreement in plans between both methods, yet an increase in fastening strengths was observed for automatically obtained plans. Hypothesys. Automatic planning of pedicle screw positions and sizing is not inferior to manual planning. Design. Prospective comparative study. Introduction. Preoperative planning in spinal deformity surgery starts by a proper selection of implant anchors throughout the instrumented spine, where pedicle screws provide the optimum choice for bone fixation. In the case of severe spinal deformities, dysplastic pedicles can limit screw usage, and therefore studying the anatomy of vertebrae from preoperative images can aid in achieving the safest screw position through optimal fastening strength. The purpose of this study is to compare manually and automatically obtained preoperative pedicle screw plans. Materials and Methods. CT scans of 17 deformed thoracic spines were studied by two experienced spine deformity surgeons, who placed 316 pedicle screws in 3D using a software positioning tool by aiming for the safest trajectory that permitted the largest possible screw sizes. The resulting manually obtained screw sizes, trajectory angles, entry points and normalised fastening strengths were compared to those obtained automatically by a dedicated computer software that, basing on vertebral anatomy and bone density in 3D, determined optimal screw sizes and trajectories. Results. Statistically significant differences were observed between manually and automatically obtained plans for screw sizes (p < 0.05) and trajectory angles (p < 0.001). However, for automatically obtained plans, screws were not smaller in diameter (p < 0.05) or shorter in length (p < 0.001), while screw normalised fastening strengths were higher (p < 0.001). Conclusions. In comparison to manual planning, automatically obtained plans did not result in smaller screw diameters or shorter screw lengths, which is in agreement with the definition of the pull-out strength, but in different screw trajectory angles, which is reflected by higher normalised fastening strengths. Captions. Fig. 1. Visual comparison among automatically obtained (green colour) and manually defined