Advertisement for orthosearch.org.uk
Results 1 - 20 of 215
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 33 - 33
14 Nov 2024
Fallahy M Shaker F Ghanbari F Aslani MA Mohammadi S Behrouzieh S
Full Access

Introduction. Knee Osteoarthritis (KOA) is a prevalent joint disease requiring accurate diagnosis and prompt management. The condition occurs due to cartilage deterioration and bone remodeling. Ultrasonography has emerged as a promising modality for diagnosing KOA. Medial meniscus extrusion (MME), characterized by displacement of medial meniscus beyond the joint line has been recognized as a significant marker of KOA progression. This study aimed to explore potentials Ultrasound findings in timely detection of MME and compare it to magnetic resonance imaging (MRI) as a reference standard. Method. A comprehensive literature search was performed in 4 databases from inception to May 1 2024. Two independent reviewers, initiated screening protocols and selected the articles based on inclusion and exclusion criteria and then extracted the data. Meta-analysis was conducted using R 4.3.2 packages mada and metafor. Result. A total of 2500 articles from 4 databases was retrieved; however, following the application of inclusion and exclusion criteria 23 articles were finally extracted. These studies collectively encompassed a total of 777 patients with mean age of 53.2±7.4. The mean BMI calculated for patients was 28.31 ± 2.45. All patients underwent non-weight bearing knee ultrasonography in supine position with 0° flexion. The reported medial meniscus extrusion was 2.58 mm for articles using MRI and 2.65 mm for those using Ultrasound (MD: 0.05 ± 0.12, P= 0.65, I. 2. : 54%). Our meta-analysis revealed insignificant difference between US and MRI. (SMD: 0.03, 95% CI: -0.18 _0.23, P= 0.77, I. 2. : 56%) Meta analysis for diagnostic accuracy measures yielded a pooled sensitivity and specificity of 90.8% and 77% (95% CI: 84.2% – 94.8%, 35.5% – 95.3%, respectively, I. 2. : 44%). Conclusion. Our results indicate a close alignment in the accuracy of measurements obtained using Ultrasound modality. The narrow range suggests a minimal discrepancy in MME values between MRI and ultrasound, highlighting their comparable precision in diagnostic assessments


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 7 - 7
7 Aug 2024
Salimi H Ohyama S Terai H Hori Y Takahashi S Hoshino M Yabu A Kobayashi A Tsujio T Kotake S Nakamura H
Full Access

Background. Trunk muscles play an important role in supporting the spinal column. A decline in trunk muscle mass, as measured by bioelectrical impedance analysis (TMM–BIA), is associated with low back pain and poor quality of life. Purpose. The purpose of this study was to determine whether TMM–BIA correlates with quantitative and functional assessments traditionally used for the trunk muscles. Methods. We included 380 participants (aged ≥ 65 years; 152 males, 228 females) from the Shiraniwa Elderly Cohort (Shiraniwa) study, for whom the following data were available: TMM–BIA, lumbar magnetic resonance imaging (MRI), and back muscle strength (BMS). We measured the cross-sectional area (CSA) and fat-free CSA of the paravertebral muscles (PVM), including the erector spinae (ES), multifidus (MF), and psoas major (PM), on an axial lumbar MRI at L3/4. The correlation between TMM–BIA and the CSA of PVM, fat-free CSA of PVM, and BMS was investigated. Results. TMMBIA correlated with the CSA of total PVM and each individual PVM. A stronger correlation between TMM–BIA and fat-free CSA of PVM was observed. The TMM–BIA also strongly correlated with BMS. Conclusion. TMM–BIA is an easy and reliable way to evaluate the trunk muscle mass in a clinical setting. Conflict of interest. None. Sources of funding. None


Background. Magnetic resonance imaging (MRI) algorithm identifies end stage severely degenerated disc as ‘black’, and a moderately degenerate to non-degenerated disc as ‘white’. MRI is based on signal intensity changes that identifies loss of proteoglycans, water, and general radial bulging but lacks association with microscopic features such as fissure, endplate damage, persistent inflammatory catabolism that facilitates proteoglycan loss leading to ultimate collapse of annulus with neo-innervation and vascularization, as an indicator of pain. Thus, we propose a novel machine learning based imaging tool that combines quantifiable microscopic histopathological features with macroscopic signal intensities changes for hybrid assessment of disc degeneration. Methods. 100-disc tissue were collected from patients undergoing surgeries and cadaveric controls, age range of 35–75 years. MRI Pfirrmann grades were collected in each case, and each disc specimen were processed to identify the 1) region of interest 2) analytical imaging vector 3) data assimilation, grading and scoring pattern 4) identification of machine learning algorithm 5) predictive learning parameters to form an interface between hardware and software operating system. Results. Kernel algorithm defines non-linear data in xy histogram. X,Y values are scored histological spatial variables that signifies loss of proteoglycans, blood vessels ingrowth, and occurrence of tears or fissures in the inner and outer annulus regions mapped with the dampening and graded series of signal intensity changes. Conclusion. To our knowledge this study is the first to propose a machine learning method between microscopic spatial tissue changes and macroscopic signal intensity grades in the intervertebral disc. No conflict of interest declared.  . Sources of Funding. ICMR/5/4-5/3/42/Neuro/2022-NCD-1, Dr TMA PAI SMU/ 131/ REG/ TMA PURK/ 164/2020. A part of the above study was presented as an oral paper at the International Society for the Study of Lumbar Spine (ISSLS) meeting held on 1–5. th. May 2023, Melbourne, Australia


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 28 - 28
10 May 2024
Warindra T
Full Access

Discoid meniscus (DM) is a congenital variant of the knee joint that involves morphological and structural deformation, with potential meniscal instability. The prevalence of the Discoid Lateral Meniscus (DLM) is higher among the Asians than among other races, and both knees are often involved. Meniscal pathology is widely prevalent in the adult population, secondary to acute trauma and chronic degeneration. The true prevalence in children remains unknown, as pathologies such as discoid menisci often go undiagnosed, or are only found incidentally. A torn or unstable discoid meniscus can present with symptoms of knee pain, a snapping or clicking sensation and/or a decrease in functional activity, although it is not known if a specific presentation is indicative of a torn DM. While simple radiographs may provide indirect signs of DLM, magnetic resonance imaging (MRI) and arthroscopy is essential for diagnosis and treatment planning. Asymptomatic patients require close follow-up without surgical treatment, while patients with symptoms often require surgery. Partial meniscectomy is currently considered the treatment of choice for DLM. For children are more likely to achieve better results after partial meniscectomy


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 1 - 1
8 May 2024
Wiewiorski M Barg A Valderrabano V
Full Access

Introduction. Autologous Matrix Induced Chondrogenesis (AMIC) for surgical treatment of osteochondral lesions of the talus (OCLT) has shown excellent clinical and radiological results at short term follow up two years after surgery. However, no mid-term follow up data is available. Aim. 1. To evaluate the clinical outcome after AMIC-aided reconstruction of osteochondral lesions of the talus at a minimum follow up time of five years. 2. To evaluate the morphology and quality of the regenerated cartilage by magnetic resonance imaging (MRI) at on at a minimum follow up time of five years. Methods. Seventeen patients prospectively underwent surgery receiving a AMIC-aided repair of OCLT consisting of debridement, autologous grafting, and sealing of the defect with a collagen scaffold (Chondro-Gide, Geistlich Surgery, Wolhusen, Switzerland). Clinical and radiological assessment was performed before and after a minimum of 60 months after surgery (average 78 months, range, 60–120). Clinical examination included the American Orthopaedic Foot & Ankle Society (AOFAS) ankle score and the Visual Analogue Scale (VAS). Radiological imaging consisted of MRI. The Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) score was applied. Results. The AOFAS ankle score improved significantly from a mean of 60 points preoperatively (range, 17–79) to 91 points (range, 70–100) postoperatively (p< 0.01). The preoperative pain score averaged a VAS of 5 (range, 2–8), improving to an average of 1.1 (range 0–8) (p< 0.01). The MOCART score for cartilage repair tissue on postoperative MRI averaged 71 points (range, 50–90). Conclusion. The AMIC-procedure is safe for the treatment of OCLT with overall good clinical and magnetic resonance imaging results at five years follow up


Several studies have evaluated the risk of peroneal nerve (PN) injuries in all-inside lateral meniscal repair using standard knee magnetic resonance imaging (MRI) with the 30 degrees flexed knee position which is different from the knee position during actual arthroscopic lateral meniscal repair. The point of concern is “Can the risk of PN injury using standard knee MRIs be accurately determined”. To evaluate and compare the risk of PN injury in all-inside lateral meniscal repair in relation to both borders of the popliteus tendon (PT) using MRIs of the two knee positions in the same patients. Using axial MRI studies with standard knee MRIs and figure-of-4 with joint fluid dilatation actual arthroscopic lateral meniscal repair position MRIs, direct lines were drawn simulating a straight all-inside meniscal repair device from the anteromedial and anterolateral portals to the medial and lateral borders of the PT. The distance from the tip of each line to the PN was measured. If a line touched or passed the PN, a potential risk of iatrogenic injury was noted and a new line was drawn from the same portal to the border of the PN. The danger area was measured from the first line to the new direct line along the joint capsule. In 28 adult patients, the closest distances from each line to the PN in standard knee MRI images were significantly shorter than arthroscopic position MRI images (all p-values < 0.05). All danger areas assessed in the actual arthroscopic position MRIs were included within the danger areas as assessed by the standard knee MRIs. We found that the standard knee MRIs can be used to determine the risk of peroneal nerve injury in arthroscopic lateral meniscal repair, although the risks are slightly overestimated


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 23 - 23
7 Nov 2023
Mulaudzi NP Mzayiya N Rachuene P
Full Access

Os acromiale is a developmental defect caused by failure of fusion of the anterior epiphysis of the acromion between the ages of 22 and 25. The prevalence of os acromiale in the general population ranges from 1.4% to 15%. Os acromiale has been reported as a contributory factor to shoulder impingement symptoms and rotator cuff injuries, despite being a common incidental observation. In this retrospective study, we examined the prevalence of os acromiale in black African patients with shoulder pain. We retrospectively reviewed the clinical records, radiographs, and magnetic resonance imaging (MRI) scans of 119 patients who presented with atraumatic and minor traumatic shoulder pain at a single institution over a one-year period. Anteroposterior, scapula Y-view, and axillary view plain images were initially evaluated for the presence of os acromiale, and this was corroborated with axial MRI image findings. Patients with verified os acromiale had their medical records reviewed to determine their first complaint and the results of their clinical examination and imaging examination. Radiographs and MRI on 24 patients (20%) revealed an osacromiale. This cohort had a mean age of 59.2 years, and there were significantly more females (65%) than males. Meso-acromion was identified as the most prevalent type (n=11), followed by pre-os acromion (n=7). All patients underwent bilateral shoulder x-rays, and 45 percent of patients were found to have bilateral meso- acromion. Most patients (70%) were reported to have unstable os acromiale with subacromial impingement symptoms, and nine patients (36%) had confirmed rotator cuff tears based on clinical and Mri findings. Surgery was necessary for 47% of the 24 patients with confirmed Os acromiale (arthroscopic surgery, n=7; open surgery, n=1) in order to treat their symptoms. The prevalence of os acromiale in our African patients with atraumatic shoulder symptoms is greater than that reported in the general population. Os acromiale is a rare condition that should always be considered when evaluating shoulder pain patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 67 - 67
7 Nov 2023
Mogale N van Schoor A Scott J Schantz D Ilyasov V Bush TR Slade JM
Full Access

Pressure ulcers are a common occurrence in individuals with spinal cord injuries, and are attributed to prolonged sitting and limited mobility. This therefore creates the need to better understand soft tissue composition, in the attempt to prevent and treat pressure ulcers. In this study, novel approaches to imaging the soft tissue of the buttocks were investigated in the loaded and unloaded position using ultrasound (US) and magnetic resonance imaging (MRI). Twenty-six able-bodied participants (n=26, 13 males and 13 females) were recruited for this study and 1 male with a spinal cord injury. Two visits using US were required, as well as one MRI visit to evaluate soft tissue thickness and composition. US Imaging for the loaded conditions was performed using an innovative chair which allowed image acquisition in the seated upright position and MRI was done in the lateral decubitus position and loading was applied to the buttocks using a newly developed MRI compatible loader. The unloaded condition was a lateral decubitus position. Soft tissue was measured between the peak of the ischial tuberosity (IT) and the proximal femur and skin. Tissue thickness reliability for US was excellent, ICC=0.934–0.981 with no significant differences between the scan days. US and MRI measures of tissue thickness were significantly correlated (r=0.68–0.91). US underestimated unloaded tissue thicknesses with a mean bias of 0.39 – 0.56 for total tissue and muscle + tendon thickness. When the buttocks were loaded, total tissue thickness was reduced by 64.2±9.1%. US assessment of soft tissue thicknesses was reliable in both positions. The unloaded measurements using US were validated with MRI with acceptable limits of agreement, albeit tended to underestimate tissue thickness. Tissue thickness, but not fatty infiltration of muscle played a role in how the soft tissue of the buttocks responded to loading


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 45 - 45
23 Jun 2023
Lieberman JR
Full Access

Modular dual mobility (DM) articulations are increasingly utilized during total hip arthroplasty (THA). However, concerns remain regarding the metal liner modularity. This study aims to correlate metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) abnormalities with serum metal ion levels in patients with DM articulations. All patients with an asymptomatic, primary THA and DM articulation with >2-year follow-up underwent MARS-MRI of the operative hip. Each patient had serum cobalt, chromium, and titanium levels drawn. Patient satisfaction, Oxford Hip Score, and Forgotten Joint Score-12 (FJS-12) were collected. Each MARS-MRI was independently reviewed by fellowship-trained musculoskeletal radiologists blinded to serum ion levels. Forty-five patients (50 hips) with a modular DM articulation were included with average follow-up of 3.7±1.2 years. Two patients (4.4%) had abnormal periprosthetic fluid collections on MARS-MRI with cobalt levels >3.0 μg/L. Four patients (8.9%) had MARS-MRI findings consistent with greater trochanteric bursitis, all with cobalt levels < 1.0 μg/L. A seventh patient had a periprosthetic fluid collection with normal ion levels. Of the 38 patients without MARS-MRI abnormalities, 37 (97.4%) had cobalt levels <1.0 μg/L, while one (2.6%) had a cobalt level of 1.4 μg/L. One patient (2.2%) had a chromium level >3.0 μg/L and a periprosthetic fluid collection. Of the 41 patients with titanium levels, five (12.2%) had titanium levels >5.0 μg/L without associated MARS-MRI abnormalities. Periprosthetic fluid collections associated with elevated serum cobalt levels in patients with asymptomatic dual mobility articulations occur infrequently (4.4%), but further assessment of these patients is necessary. Level of Evidence: Level IV


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 89 - 89
17 Apr 2023
Alzahrani S Aljuaid M Bazaid Z Shurbaji S
Full Access

A Morel-Lavallee lesion (MLL) is a benign cystic lesion that occurs due to injury to the soft-tissue envelope's perforating vascular and lymphatic systems, resulting in a distinctive hemolymphatic fluid accumulation between the tissue layers. The MLL has the potential to make a significant impact on the treatment of orthopaedic injuries. A 79-year-old male patient community ambulatory with assisting aid (cane) known case of Diabetes mellitus, hypertension, bronchial asthma and ischemic heart disease. He was brought to the Emergency, complaining of right hip discomfort and burning sensation for the last 5 days with no history of recent trauma at all. Patient had history of right trochanteric femur fracture 3 years ago, treated with DHS in a privet service. Clinical and Radiological assessment showed that the patient mostly has acute MLL due to lag screw cut out. We offered the patient the surgical intervention, but he refused despite explaining the risks of complications if not treated and preferred to receive the conservative treatment. Compression therapy management explained to him including biker's shorts (instructed to be worn full-time a day) and regular follow up in clinic. Symptom's improvement was reported by the patient in the subsequent visits. In the polytrauma patient, a delayed diagnosis of these lesions is conceivable due to the presence of more visible injuries. It's located over the greater trochanter more commonly, but sometimes in other areas such as the lower lumbar region, the thigh, or the calf. Incorrect or delayed diagnosis and care can have unfavorable outcomes such as infection, pseudocyst development, and cosmetologically deformity. Magnetic resonance imaging (MRI) and ultrasound will aid in MLL diagnosis. However, the effectiveness of MLL therapy remains debatable. We strongly believe that the MLL caused due to tangential shear forces applied to the soft tissue leads to accumulation of the blood and/or lymph between the subcutaneous and overlying fascia and it often misdiagnosed due to other distracting injuries. Nontheless, in our case we reported MLL occur due to internal pressure on the fascia caused by cut out of DHS lag screw


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 88 - 88
17 Apr 2023
Aljuaid M Alzahrani S Alzahrani A Filimban S Alghamdi N Alswat M
Full Access

Cervical spine facet tropism (CFT) defined as the facets’ joints angles difference between right and left sides of more than 7 degrees. This study aims to investigate the relationship between cervical sagittal alignment parameters and cervical spine facets’ tropism. A retrospective cross-sectional study carried out in a tertiary center where cervical spine magnetic resonance imaging (MRI) radiographs of patients in orthopedics/spine clincs were included. They had no history of spine fractures. Images’ reports were reviewed to exclude those with tumors in the c-spine. A total of 96 patients was included with 63% of them were females. The mean of age was 45.53± 12.82. C2-C7 cobb's angle (CA) and C2-C7 sagittal vertical axis (SVA) means were −2.85±10.68 and 1.51± 0.79, respectively. Facet tropism was found in 98% of the sample in at least one level on either axial or sagittal plane. Axial C 2–3 CFT and sagittal C4-5 were correlated with CA (r=0.246, P 0.043, r= −278, P 0.022), respectively. In addition, C2-C7 sagittal vertical axis (SVA) was moderately correlated with axial c2-3 FT (r= −0.330, P 0.006) Also, several significant correlations were detected in our model Cervical vertebral slopes and CFT at the related level. Nonetheless, high BMI was associated with multi-level and multiplane CFT with higher odd's ratios at the lower levels. This study shows that CFT at higher levels is correlated with increasing CA and decreasing SVA and at lower levels with decreasing CA. Obesity is a risk factor for CFT


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 12 - 12
11 Apr 2023
Swain L Shillabeer D Wyatt H Jonkers I Holt C Williams D
Full Access

Biplane video X-ray (BVX) – with models segmented from magnetic resonance imaging (MRI) – is used to directly track bones during dynamic activities. Investigating tibiofemoral kinematics helps to understand effects of disease, injury, and possible interventions. Develop a protocol and compare in-vivo kinematics during loaded dynamic activities using BVX and MRI. BVX (60 FPS) was captured whilst three healthy volunteers performed three repeats of lunge, stair ascent and gait. MRI scans were performed (Magnetom 3T Prisma, Siemens). 3D bone models of the tibia and femur were segmented (Simpleware Scan IP, Synopsis). Bone poses were obtained by manually matching bone models to X-rays (DSX Suite, C-Motion Inc.). Mean range of motion (ROM) of the contact points on the medial and lateral tibial plateau were calculated using custom MATLAB code (MathWorks). Results were filtered using an adaptive low pass Butterworth filter (Frequency range: 5-29Hz). Gait and Stair ascent activities from one participant's data showed increased ROM for medial-lateral (ML) translation in the medial compartment but decreased ROM in anterior-posterior (AP) translation when comparing against the same translations on the lateral compartment of the tibial plateau. Lunge activity showed increased ROM for both ML and AP translation in the medial compartment when compared with the lateral compartment. These results highlight the variability in condylar translations between different activities. Understanding healthy in-vivo kinematics across different activities allows the determination of suitable activities to best investigate the kinematic changes due to disease or injury and assess the efficacy of different interventions. Acknowledgements: This research was supported by the Engineering and Physical Sciences Research Council (EPSRC) doctoral training grant (EP/T517951/1)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 18 - 18
4 Apr 2023
Stanley A Jones G Edwards T Lex J Jaere M
Full Access

Knee pain is common, representing a significant socioeconomic burden. Caused by a variety of pathologies, its evaluation in primary-care is challenging. Subsequently, an over-reliance on magnetic resonance imaging (MRI) exists. Prior to orthopaedic surgeon referral, many patients receive no, or incorrect, imaging. Electronic-triage (e-triage) tools represent an innovative solution to address this problem. The primary aim of this study was to ascertain whether an e-triage tool is capable of outperforming existing clinical pathways to determine the correct pre-hospital imaging based on knee pain diagnosis. Patients ≥18 years with a new presentation of knee pain were retrospectively identified. The timing and appropriateness of imaging was assessed. A symptom-based e-triage tool was developed, using the Amazon LEXbotplatform, and piloted to predict five common knee pathologies and suggest appropriate imaging. 1462 patients were identified. 17% of arthroplasty patients received an ‘unnecessary MRI’, whilst 28% of arthroscopy patients did not have a ‘necessary MRI’, thus requiring a follow-up appointment, with a mean delay of three months (SD 2.6, range 0.2-20.2). Using NHS tariffs, a wasted cost through unnecessary/necessary MRIs and subsequent follow-up appointments was estimated at £45,816. The e-triage pilot was trialled with 41 patients (mean age:58.4 years, 58.5% female). Preliminary diagnoses were available for 34 patients. Using the highest proportion of reported symptoms in the corresponding group, the e-triage tool correctly identified three of the four knee pathologies. The e-triage tool did not correctly identify anterior cruciate ligament injuries (n=3). 79.2% of participants would use the tool again. A significant number of knee pathology patients received incorrect imaging prior to their initial hospital appointment, incurring delays and unnecessary costs. A symptom-based e-triage tool was developed, with promising pilot data and user feedback. With refinement, this tool has the potential to improve wait-times and referral quality, whilst reducing costs


Increasing expectations from arthroscopic anterior cruciate ligament (ACL) reconstructions require precise knowledge of technical details such as minimum intra-femoral tunnel graft lengths. A common belief of having ≥20mm of grafts within the femoral tunnel is backed mostly by hearsay rather than scientific proof. We examined clinico-radiological outcomes in patients with intra-femoral tunnel graft lengths <20 and ≥20mm. Primary outcomes were knee scores at 1-year. Secondarily, graft revascularization was compared using magnetic resonance imaging (MRI). We hypothesized that outcomes would be independent of intra-femoral tunnel graft lengths. This prospective, single-surgeon, cohort study was conducted at a tertiary care teaching centre between 2015–2018 after obtaining ethical clearances and consents. Eligible arthroscopic ACL reconstruction patients were sequentially divided into 2 groups based on the intra-femoral tunnel graft lengths (A: < 20 mm, n = 27; and B: ≥ 20 mm, n = 25). Exclusions were made for those > 45 years of age, with chondral and/or multi-ligamentous injuries and with systemic pathologies. All patients were postoperatively examined and scored (Lysholm and modified Cincinnati scores) at 3, 6 and 12 months. Graft vascularity was assessed by signal-to-noise quotient ratio (SNQR) using MRI. Statistical significance was set at p<0.05. Age and sex-matched patients of both groups were followed to 1 year (1 dropout in each). Mean femoral and tibial tunnel diameters (P =0.225 and 0.595) were comparable. Groups A (<20mm) and B (≥20mm) had 27 and 25 patients respectively. At 3 months, 2 group A patients and 1 group B patient had grade 1 Lachman (increased at 12 months to 4 and 3 patients respectively). Pivot shift was negative in all patients. Lysholm scores at 3 and 6 months were comparable (P3= 0.195 and P6= 0.133). At 1 year both groups showed comparable Cincinnati scores. Mean ROM was satisfactory (≥130 degrees) in all but 2 patients of each group (125–130 degrees). MRI scans at 3 months and 1 year observed anatomical tunnels in all without any complications. Femoral tunnel signals in both groups showed a fall from 3–12 months indicating onset of maturation of graft at femoral tunnel. Our hypothesis, clinical and radiological outcomes would be independent of intra-tunnel graft lengths on the femoral aspect, did therefore prove correct. Intra-femoral tunnel graft lengths of <20 mm did not compromise early clinical and functional outcomes of ACL reconstructions. There seems to be no minimum length of graft within the tunnel below which suboptimal results should be expected


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 6 - 6
1 Dec 2022
Roversi G Nusiner F De Filippo F Rizzo A Colosio A Saccomanno M Milano G
Full Access

Recent studies on animal models focused on the effect of preserving tendon remnant of rotator cuff on tendon healing. A positive effect by combining tendon remnant preservation and small bone vents on the greater tuberosity in comparison with standard tendon-to-bone repair has been shown. The purpose of the present clinical study was to evaluate the efficacy of biologic augmentation of arthroscopic rotator cuff repair by maintaining tendon remnant on rotator cuff footprint combined with small bone vents of the greater tuberosity. A retrospective study was conducted. All patients who underwent arthroscopic rotator cuff repair associated with small bone vents (nanofractures) and tendon footprint preservation were considered eligible for the study. Inclusion criteria were: diagnosis of full-thickness rotator cuff tear as diagnosed at preoperative magnetic resonance imaging (MRI) and confirmed at the time of surgery; minimum 24-month of follow-up and availability of post-operative MRI performed not earlier than 6 months after surgery. Exclusion criteria were: partial thickness tears, irreparable tears, capsulo-labral pathologies, calcific tendonitis, gleno-humeral osteoarthritis and/or previous surgery. Primary outcome was the ASES score. Secondary outcomes were: Quick-DASH and WORC scores, and structural integrity of repaired tendons by magnetic resonance imaging (MRI) performed six months after surgery. A paired t-test was used to compare pre- and postoperative clinical outcomes. Subgroup analysis was performed according to tear size. Significance was set at p < 0.05. The study included 29 patients (M:F = 15:14). Mean age (+ SD) of patients was 61.7 + 8.9 years. Mean follow-up was 27.4 ± 2.3 months. Comparison between pre- and postoperative functional scores showed significant clinical improvement (p < 0.001). Subgroup analysis for tear size showed significant differences in the QuickDASH score (0.04). Particularly, a significant difference in the QuickDASH score could be detected between medium and large tears (p=0.008) as well as medium and massive lesions (p=0.04). No differences could be detected between large and massive tears (p= 0.35). Postoperative imaging showed healed tendons in 21 out of 29 (72%) cases. Preservation of tendon remnant combined with small bone vents in the repair of medium-to-massive full-thickness rotator cuff tears provided significant improvement in clinical outcome compared to baseline conditions with complete structural integrity in 72% of the cases


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 11 - 11
1 Dec 2022
Bergomi A Adriani M De Filippo F Manni F Motta M Saccomanno M Milano G
Full Access

Rotator cuff repair has excellent clinical outcomes but continues to be a challenge when it comes to large and massive tears as well as revision procedures. Reported symptomatic retear rates are still too high to be acceptable. The purpose of the present study was to evaluate the effectiveness of a combination of augmentation techniques consisting of microfractures of the greater tuberosity, extracellular matrix (ECM) patch graft and subsequent platelet concentrate (PC) subacromial injections in revision rotator cuff repair. The study was designed as a retrospective comparative study on prospectively collected data from a consecutive cohort of patients. All patients who underwent arthroscopic revision rotator cuff repair for symptomatic failure of previous posterosuperior rotator cuff repair were considered eligible for the study. Symptomatic failure had been diagnosed according to clinical examination and confirmed by magnetic resonance imaging (MRI). Structural integrity had been assessed on MRI and classified according to Sugaya classification. Only patients affected by stage IV-V were considered eligible. Tear reparability was confirmed during arthroscopy. Only patients with a minimum 2 years follow-up were included. Patients were divided in two groups. In group 1 (control group) a standard arthroscopic revision and microfractures of the greater tuberosity were performed; in group 2 (experimental group), microfractures of the greater tuberosity and a ECM patch graft were used to enhance tendon repair, followed by postoperative PC injections. Minimum follow-up was 12 months. Primary outcome was the Constant-Murley score (CMS) normalized for age and gender. Subjective outcome was assessed with the Disabilities of the Arm, Shoulder and Hand (DASH) score in its short version (Quick-DASH). Tendon integrity was assessed with MRI at 6 months after surgery. Comparison between groups for all discrete variables at baseline and at follow-up was carried out with the Student's t-test for normally distributed data, otherwise Mann-Whitney U-test was used. Within-group differences (baseline vs follow-up) for discrete variables were analyzed by paired t-test, or by Wilcoxon signed-rank test in case of data with non-normal distribution. Differences for categorical variables were assessed by chi-squared test. Significance was considered for p values < 0.05. Forty patients were included in the study (20 patients for each group). The mean follow-up was 13 ± 1.6 months. No patients were lost at the follow up. Comparison between groups did not show significant differences for baseline characteristics. At follow-up, mean CMS was 80.7 ± 16.6 points in group 1 and 91.5 ± 11.5 points in group 2 (p= 0.022). Mean DASH score was 28.6 ± 21.6 points in group 1 and 20.1 ± 17.4 points in group 2 (p= 0.178). Post-operative MRI showed 6 healed shoulders in Group 1 and 16 healed shoulders in Group 2 (p<0.004). No postoperative complications were reported in both groups. The combination of microfractures of the greater tuberosity, ECM patch graft, and subsequent PC subacromial injections is an effective strategy in improving tendon healing rate


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 25 - 25
1 Dec 2022
Spina G Napoleone F Mancuso C Gasparini G Mercurio M Familiari FF
Full Access

Magnetic resonance imaging (MRI) is the gold standard for the diagnosis of the pathologies affecting the glenohumeral joint and the rotator cuff diseases. MRI allows to highlight anatomic discontinuities of both muscles and tendons. However, MRI diagnostic accuracy has not proven to be highly sensitive in distinguishing between a partial-thickness tear and a full-thickness rotator cuff tear. The purpose of this study was to determine if MRI under axial traction can be helpful in increasing MRI sensitivity to identify partial-thickness rotator cuff tears. The study included 10 patients (4 males and 6 females) who had clinical examination and MRI suggesting a partial-thickness rotator cuff tear. They were candidates for shoulder arthroscopy because of persistent symptoms after at least three months of conservative treatment. The patients underwent a new MRI (under axial traction: MRI-AT) with a 4-kg weight applied to the affected arm. Then the patients underwent arthroscopy to confirm the diagnosis. Patients with a suspected full-thickness rotator cuff tear were excluded from the study. Patients’ average age was 52.4 years, and the dominant side was affected in 77.7% of the cases. Preoperative Constant-Murley Score was 57. MRI-AT showed that 3 patients were affected by a complete tear of the rotator cuff, 3 patients by a partial-thickness rotator cuff tear and 4 patients had no lesion. The analysis of data showed that: under axial traction the subacromial space increased by 0,2 mm (P value = 0,001075), the superior glenohumeral space decreased by 2.4 mm (P value = 0,07414), the inferior glenohumeral space increased by 0.3 mm (P value = 0,02942), the acromial angle decreased by 1.9° (P value = 0,0002104) and the acromion-glenohumeral angle decreased by 0.3° (P-value = 0,01974). Two experienced evaluators analyzed previous standard MRI and MRI-AT scans in a double-blinded fashion, with inter-rater evaluation of all the images and measures. Intraclass correlation coefficient (ICC) has been utilized to assess the reliability of the measures performed by different operators. ICC always resulted in more than 0.7, showing a high concordance among values in the same group. A comparative evaluation between standard MRI and MRI-AT has been conducted to highlight possible discrepancies and this has been compared to intraoperative findings. Concordance of the values was 89% between standard MRI and MRI-AT and 100% between MRI under axial traction and intraoperative findings. This study showed a high correlation between the diagnosis achieved with MRI-AT and the intraoperative arthroscopic findings. The use of MRI-AT in clinical practice may improve the diagnostic sensitivity of this method to detect a partial-thickness rotator cuff tear


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 84 - 84
1 Dec 2022
du Toit C Dima R Jonnalagadda M Fenster A Lalone E
Full Access

The opposable thumb is one of the defining characteristics of human anatomy and is involved in most activities of daily life. Lack of optimal thumb motion results in pain, weakness, and decrease in quality of life. First carpometacarpal (CMC1) osteoarthritis (OA) is one of the most common sites of OA. Current clinical diagnosis and monitoring of CMC1 OA disease are primarily aided by X-ray radiography; however, many studies have reported discrepancies between radiographic evidence of CMC1 OA and patient-related outcomes of pain and disability. Radiographs lack soft-tissue contrast and are insufficient for the detection of early characteristics of OA such as synovitis, which play a key role in CMC OA disease progression. Magnetic resonance imaging (MRI) and two-dimensional ultrasound (2D-US) are alternative options that are excellent for imaging soft tissue pathology. However, MRI has high operating costs and long wait-times, while 2D-US is highly operator dependent and provides 2D images of 3D anatomical structures. Three-dimensional ultrasound imaging may be an option to address the clinical need for a rapid and safe point of care imaging device. The purpose of this research project is to validate the use of mechanically translated 3D-US in CMC OA patients to assess the measurement capabilities of the device in a clinically diverse population in comparison to MRI. Four CMC1-OA patients were scanned using the 3D-US device, which was attached to a Canon Aplio i700 US machine with a 14L5 linear transducer with a 10MHz operating frequency and 58mm. Complimentary MR images were acquired using a 3.0 T MRI system and LT 3D coronal photon dense cube fat suppression sequence was used. The volume of the synovium was segmented from both 3D-US and MR images by two raters and the measured volumes were compared to find volume percent differences. Paired sample t-test were used to determine any statistically significant differences between the volumetric measurements observed by the raters and in the measurements found using MRI vs. 3D-US. Interclass Correlation Coefficients were used to determine inter- and intra-rater reliability. The mean volume percent difference observed between the two raters for the 3D-US and MRI acquired synovial volumes was 1.77% and 4.76%, respectively. The smallest percent difference in volume found between raters was 0.91% and was from an MR image. A paired sample t-test demonstrated that there was no significant difference between the volumetric values observed between MRI and 3D-US. ICC values of 0.99 and 0.98 for 3D-US and MRI respectively, indicate that there was excellent inter-rater reliability between the two raters. A novel application of a 3D-US acquisition device was evaluated using a CMC OA patient population to determine its clinical feasibility and measurement capabilities in comparison to MRI. As this device is compatible with any commercially available ultrasound machine, it increases its accessibility and ease of use, while proving a method for overcoming some of the limitations associated with radiography, MRI, and 2DUS. 3DUS has the potential to provide clinicians with a tool to quantitatively measure and monitor OA progression at the patient's bedside


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 1 - 1
1 Nov 2022
Patel R
Full Access

Abstract. Aims. The aim of this study was to evaluate the indications for patients presenting with knee pain undergoing magnetic resonance imaging of the knee prior to referral to the orthopaedic department and to ascertain whether plain radiograph imagining would be more beneficial prior to an MRI scan. Method. A retrospective review of all referrals received by the hospital over a 6-month period was performed. Patients with knee pain that underwent an MRI scan were classified into two age groups, under 50 years and over 50 years old. Patients having undergone Magnetic resonance imaging (MRI) prior to referral were identified, and findings of the scan were recorded. These patients were reviewed further to see if a plain radiograph had been completed prior to or after the MRI. Results. A total of 414 patients were referred. In the over 50's 228 MRI scans were performed. Of these 103/228 patients the predominate finding was meniscal tears and 72/228 had a finding of osteoarthritis. A plain radiograph of the knee was completed 99/228 cases, 28/99 before the MRI. In the under 50's 186 scans were performed and of these 85/186 the predominate finding was meniscal tears. A plain radiograph of the knee was completed in only eighty-three (83/186) cases, (69/83) before the MRI. Conclusion. In over 50s, 57% of patients (129 of 228) did not have a knee X-ray before having an MRI. For a single hospitals referral over 6 months these unnecessary MRI of knee cost the National Health Services £7,500


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 66 - 66
1 Oct 2022
Hulsen D Arts C Geurts J Loeffen D Mitea C
Full Access

Aim. Magnetic resonance imaging (MRI) and 2-[. 18. F]-fluoro-2-deoxy-D-glucose (. 18. F-FDG) Positron Emission Tomography, paired with Computed Tomography (PET/CT) are two indicated advanced imaging modalities in the complicated diagnostic work-up of osteomyelitis. PET/MRI is a relatively novel hybrid modality with suggested applications in musculoskeletal infection imaging. The goal of this study was to assess the value of hybrid . 18. F-FDG PET/MRI for chronic osteomyelitis diagnosis and surgical planning. Method. Five suspected chronic osteomyelitis patients underwent a prospective . 18. F-FDG single-injection/dual-imaging protocol with hybrid PET/CT and hybrid PET/MR. Diagnosis and relevant clinical features for the surgeon planning treatment were compared. Subsequently, 36 patients with . 18. F-FDG PET/MRI scans for suspected osteomyelitis were analysed retrospectively. Sensitivity, specificity, and accuracy were determined with the clinical assessment as the ground truth. Standardized uptake values (SUV) were measured and analysed by means of receiver operating characteristics (ROC). Results. The consensus diagnosis was identical for PET/CT and PET/MRI in the prospective cases, with PET/CT missing one clinical feature. The retrospective analysis yielded a sensitivity, specificity, and accuracy of 78%, 100%, and 86% respectively. Area under the ROC curve was .736, .755, and.769 for the SUVmax, target to background ratio, and SUVmax_ratio respectively. These results are in the same range and not statistically different compared to diagnostic value for . 18. F-FDG PET/CT imaging of osteomyelitis in literature. Conclusions. Based on our qualitative comparison, reduced radiation dose, and the diagnostic value that was found, the authors propose . 18. F-FDG PET/MRI as an alternative to . 18. F-FDG PET/CT in osteomyelitis diagnosis, if available