Advertisement for orthosearch.org.uk
Results 1 - 20 of 608
Results per page:
Bone & Joint 360
Vol. 13, Issue 4 | Pages 31 - 35
2 Aug 2024

The August 2024 Trauma Roundup360 looks at: Does topical vancomycin prevent fracture-related infections in closed fractures undergoing open reduction and internal fixation? A randomized controlled trial; Is postoperative splinting advantageous after upper limb fracture surgery?; Does suprapatellar nailing resolve knee pain?; Locking versus non-locking plate fixation in comminuted talar neck fractures: a biomechanical study using cadaveric specimens; Revolutionizing recovery metrics: PROMIS versus SMFA in orthopaedic trauma care; Dorsal hook plating of patella fractures: reliable fixation and satisfactory outcomes; The impact of obesity on subtrochanteric femur fracture outcomes; Low-dose NSAIDs (ketorolac) and cytokine modulation in orthopaedic polytrauma: a detailed analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 842 - 848
1 Aug 2024
Kriechling P Whitefield R Makaram NS Brown IDM Mackenzie SP Robinson CM

Aims

Vascular compromise due to arterial injury is a rare but serious complication of a proximal humeral fracture. The aims of this study were to report its incidence in a large urban population, and to identify clinical and radiological factors which are associated with this complication. We also evaluated the results of the use of our protocol for the management of these injuries.

Methods

A total of 3,497 adult patients with a proximal humeral fracture were managed between January 2015 and December 2022 in a single tertiary trauma centre. Their mean age was 66.7 years (18 to 103) and 2,510 (72%) were female. We compared the demographic data, clinical features, and configuration of those whose fracture was complicated by vascular compromise with those of the remaining patients. The incidence of vascular compromise was calculated from national population data, and predictive factors for its occurrence were investigated using univariate analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 646 - 655
1 Jul 2024
Longo UG Gulotta LV De Salvatore S Lalli A Bandini B Giannarelli D Denaro V

Aims

Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures.

Methods

The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 2 - 2
17 Jun 2024
Fishley W Morrison R Baldock T Hilley A Baker P Townshend D
Full Access

Background. In fixation of the fibula in ankle fractures, AO advocate using a lag screw and one-third tubular neutralisation plate for simple patterns. Where a lag screw cannot be placed, bridging fixation is required. A local pilot service evaluation previously identified variance in use of locking plates in all patterns with significant cost implications. The FAIR study aimed to evaluate current practice and implant use across the United Kingdom (UK) and review outcomes and complication rates between different fibula fixation methods. Method. The study was supported by CORNET, the North East trainee research collaborative, and BOTA. Data was collected using REDCap from 22 centres in the UK retrospectively for a one-year period between 1. st. January 2019 and 31. st. December 2019 on injury mechanism, fracture characteristics, comorbidities, fixation and complications. Follow-up data was collected to at least two-years from the time surgery. Results. 1448 ankle fractures which involved fixation of the fibula were recorded; one-third tubular plate was used in 866 (59.8%) cases, a locking plate in 463 (32.0%) cases and other methods in 119 (8.2%) cases. There was significant difference between centres (p<0.001) in implant type used. Other factors associated with implant type were age, diabetes, osteoporosis, open fractures, fracture pattern and the presence of comminution. Incidence of lateral wound breakdown was higher in locking plates than one-third tubular plates (p<0.05). There was no significant difference in infection, non-union, fixation failure or removal of metalware. Conclusion. There is significant variation in practice in the UK in implant use for fixation of the fibula in ankle fractures. Potentially unnecessary use of locking plates, where a one-third tubular shows equivalent outcomes, incurs additional cost and may increase the risk of lateral wound breakdown. We would encourage surgeons with high locking plate usage to evaluate their own unit's practice against this data


Bone & Joint Open
Vol. 5, Issue 6 | Pages 489 - 498
12 Jun 2024
Kriechling P Bowley ALW Ross LA Moran M Scott CEH

Aims. The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs). Methods. All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution. Results. A total of 111 PDFFs (111 patients, median age 82 years (interquartile range (IQR) 75 to 88), 86% female) with 32 (29%) Su classification 1, 37 (34%) Su 2, and 40 (37%) Su 3 fractures were included. The median follow-up was 2.5 years (IQR 1.2 to 5.0). DP, SP, and DFA were used in 15, 66, and 30 patients, respectively. Compared to SP, patients treated with DP were more likely to have metaphyseal comminution (47% vs 14%; p = 0.009), to be low fractures (47% vs 11%; p = 0.009), and to be anatomically reduced (100% vs 71%; p = 0.030). Patients selected for DFA displayed comparable amounts of medial/metaphyseal comminution as those who underwent DP. At a minimum follow-up of two years, revision surgery for failure was performed in 11 (9.9%) cases at a median of five months (IQR 2 to 9): 0 DP patients (0%), 9 SP (14%), and 2 DFA (6.7%) (p = 0.249). Conclusion. Using a strategy of DP fixation in fractures, where the fracture was low but there was enough distal bone to accommodate locking screws, and where there is metaphyseal comminution, resulted in equivalent survival free from revision or reoperation compared to DFA and SP fixation. Cite this article: Bone Jt Open 2024;5(6):489–498


Bone & Joint 360
Vol. 13, Issue 3 | Pages 31 - 34
3 Jun 2024

The June 2024 Shoulder & Elbow Roundup360 looks at: Reverse versus anatomical total shoulder replacement for osteoarthritis? A UK national picture; Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; acid for rotator cuff repair: a systematic review and meta-analysis of randomized controlled trials; Metal or ceramic humeral head total shoulder arthroplasty: an analysis of data from the National Joint Registry; Platelet-rich plasma has better results for long-term functional improvement and pain relief for lateral epicondylitis: a systematic review and meta-analysis of randomized controlled trials; Quantitative fatty infiltration and 3D muscle volume after nonoperative treatment of symptomatic rotator cuff tears: a prospective MRI study of 79 patients; Locking plates for non-osteoporotic proximal humeral fractures in the long term; A systematic review of the treatment of primary acromioclavicular joint osteoarthritis.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 613 - 622
1 Jun 2024
Shen J Wei Z Wu H Wang X Wang S Wang G Luo F Xie Z

Aims

The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes.

Methods

Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 40 - 40
10 May 2024
Zhang J Miller R Chuang T
Full Access

Introduction. Distal femur fractures have traditionally been stabilized with either lateral locking plate or retrograde intramedullary nail. Dual-plates and nail-plate combination fixation have the theoretical biomechanical advantage, faster union and allows patients to weight bear immediately. The aim of this study is to compare single vs combination fixation, and evaluate outcomes and complications. Method. We retrospectively reviewed all patients over 60, admitted to Christchurch Hospital, between 1st Jan 2016 and 31st Dec 2022, with an AO 33A/33B/33C distal femur fracture. Patient demographics, fracture characteristics, operation details, and follow up data were recorded. Primary outcomes are union rate, ambulatory status at discharge, and surgical complications. Secondary outcomes include quality of reduction, operation time and rate of blood transfusions. Results. 114 patients were included. (92 single fixation, 22 combination fixation). Baseline demographic data and fracture characteristics did not differ between the cohorts. There was no difference in the rate of union or time to union between the two cohorts. Combination fixation patients were allowed to weight-bear as tolerated significantly more than single fixation patients (50% vs 18.9%, p=0.003). There was no difference in length of hospital stay, transfusion, complication and mortality rates. Medial translation of the distal articular block was significantly lower in the combination fixation cohort (1.2% vs 3.4%, p=0.021). Operation time was significantly longer in the combination fixation cohort (183mins vs 134mins, p<0.001). Discussion. The results show no difference in achieving union or time to union, despite better quality of fracture reduction with dual fixation. This differs to previously published literature. The clear benefit of combination fixation is immediate weight-bearing. As expected, operation times were longer with combination fixation, however this did not translate to more complications. Conclusion. Combination fixation allows earlier weight bearing, at the cost of longer operation times


Bone & Joint 360
Vol. 13, Issue 2 | Pages 35 - 38
1 Apr 2024

The April 2024 Trauma Roundup360 looks at: The infra-acetabular screw in acetabular fracture surgery; Is skin traction helpful in patients with intertrochanteric hip fractures?; Reducing pain and improving function following hip fracture surgery; Are postoperative splints helpful following ankle fracture fixation?; Biomechanics of internal fixation in Hoffa fractures: a comparison of four different constructs; Dual-plate fixation of periprosthetic distal femur fractures; Do direct oral anticoagulants necessarily mean a delay to hip fracture surgery?; Plate or retrograde nail for low distal femur fractures?.


Bone & Joint 360
Vol. 13, Issue 2 | Pages 26 - 29
1 Apr 2024

The April 2024 Wrist & Hand Roundup360 looks at: Lunocapitate versus four-corner fusion in scapholunate or scaphoid nonunion advanced collapse: a randomized controlled trial; Postoperative scaphoid alignment, smoking, and avascular necrosis determine outcomes; Grip strength signals broader health concerns in females with distal radius fractures; Clearing the smoke: how smoking status influences recovery from open carpal tunnel release surgery; Age matters: assessing the likelihood of corrective surgery after distal radius fractures; Is pronator quadratus muscle repair required after anterior plate fixation for distal radius fractures?; Efficacy of total wrist arthroplasty: a comparative analysis of inflammatory and non-inflammatory arthritis outcomes; A comprehensive review of the one-bone forearm as a salvage technique.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 236 - 242
22 Mar 2024
Guryel E McEwan J Qureshi AA Robertson A Ahluwalia R

Aims

Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest.

Methods

A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British Limb Reconstruction Society (BLRS).


Bone & Joint Research
Vol. 13, Issue 3 | Pages 124 - 126
11 Mar 2024
Shen J Wei Z Sun D Wu H Wang X Wang S Luo F Xie Z

Cite this article: Bone Joint Res 2024;13(3):124–126.


Aims

The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury.

Methods

Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 32 - 35
1 Feb 2024

The February 2024 Trauma Roundup360 looks at: Posterior malleolus fractures: what about medium-sized fragments?; Acute or delayed total hip arthroplasty after acetabular fracture fixation?; Intrawound antibiotics reduce the risk of deep infections in fracture fixation; Does the VANCO trial represent real world patients?; Can a restrictive transfusion protocol be effective beyond initial resuscitation?; What risk factors result in avascular necrosis of the talus?; Pre-existing anxiety and mood disorders have a role to play in complex regional pain syndrome; Three- and four-part proximal humeral fractures at ten years.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 107 - 107
2 Jan 2024
Pastor T Zderic I Berk T Souleiman F Vögelin E Beeres F Gueorguiev B Pastor T
Full Access

Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and optimized plate-to-bone fit design. On the other hand, mini-fragment plates used in dual plating mode have demonstrated promising clinical results. However, these two bone-implant constructs have not been investigated biomechanically in a human cadaveric model. Therefore, the aim of the current study was to compare the biomechanical competence of single superior plating using the new generation plate versus dual plating with low-profile mini-fragment plates. Sixteen paired human cadaveric clavicles were assigned pairwise to two groups for instrumentation with either a 2.7 mm Variable Angle Locking Compression Plate placed superiorly (Group 1), or with one 2.5 mm anterior plate combined with one 2.0 mm superior matrix mandible plate (Group 2). An unstable clavicle shaft fracture AO/OTA15.2C was simulated by means of a 5 mm osteotomy gap. All specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis and monitored via motion tracking. Initial stiffness was significantly higher in Group 2 (9.28±4.40 N/mm) compared to Group 1 (3.68±1.08 N/mm), p=0.003. The amplitudes of interfragmentary motions in terms of craniocaudal and shear displacement, fracture gap opening and torsion were significantly bigger over the course of 12500 cycles in Group 1 compared to Group 2; p≤0.038. Cycles to 2 mm shear displacement were significantly lower in Group 1 (22792±4346) compared to Group 2 (27437±1877), p=0.047. From a biomechanical perspective, low-profile 2.5/2.0 dual plates demonstrated significantly higher initial stiffness, less interfragmentary movements, and higher resistance to failure compared to 2.7 single superior variable-angle locking plates and can therefore be considered as a useful alternative for diaphyseal clavicle fracture fixation especially in unstable fracture configurations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 31 - 31
2 Jan 2024
Ernst M Windolf M Varjas V Gehweiler D Gueorguiev-Rüegg B Richards R
Full Access

In absence of available quantitative measures, the assessment of fracture healing based on clinical examination and X-rays remains a subjective matter. Lacking reliable information on the state of healing, rehabilitation is hardly individualized and mostly follows non evidence-based protocols building on common guidelines and personal experience. Measurement of fracture stiffness has been demonstrated as a valid outcome measure for the maturity of the repair tissue but so far has not found its way to clinical application outside the research space. However, with the recent technological advancements and trends towards digital health care, this seems about to change with new generations of instrumented implants – often unfortunately termed “smart implants” – being developed as medical devices. The AO Fracture Monitor is a novel, active, implantable sensor system designed to provide an objective measure for the assessment of fracture healing progression (1). It consists of an implantable sensor that is attached to conventional locking plates and continuously measures implant load during physiological weight bearing. Data is recorded and processed in real-time on the implant, from where it is wirelessly transmitted to a cloud application via the patient's smartphone. Thus, the system allows for timely, remote and X-ray free provision of feedback upon the mechanical competence of the repair tissue to support therapeutic decision making and individualized aftercare. The device has been developed according to medical device standards and underwent extensive verification and validation, including an in-vivo study in an ovine tibial osteotomy model, that confirmed the device's capability to depict the course of fracture healing as well as its long-term technical performance. Currently a multi-center clinical investigation is underway to demonstrate clinical safety of the novel implant system. Rendering the progression of bone fracture healing assessable, the AO Fracture Monitor carries potential to enhance today's postoperative care of fracture patients


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 80 - 80
2 Jan 2024
Mischler D Windolf M Gueorguiev B Varga P
Full Access

Osteosynthesis aims to maintain fracture reduction until bone healing occurs, which is not achieved in case of mechanical fixation failure. One form of failure is plastic plate bending due to overloading, occurring in up to 17% of midshaft fracture cases and often necessitating reoperation. This study aimed to replicate in-vivo conditions in a cadaveric experiment and to validate a finite element (FE) simulation to predict plastic plate bending. Six cadaveric bones were used to replicate an established ovine tibial osteotomy model with locking plates in-vitro with two implant materials (titanium, steel) and three fracture gap sizes (30, 60, 80 mm). The constructs were tested monotonically until plastic plate deformation under axial compression. Specimen-specific FE models were created from CT images. Implant material properties were determined using uniaxial tensile testing of dog bone shaped samples. The experimental tests were replicated in the simulations. Stiffness, yield, and maximum loads were compared between the experiment and FE models. Implant material properties (Young's modulus and yield stress) for steel and titanium were 184 GPa and 875 MPa, and 105 GPa and 761 MPa, respectively. Yield and maximum loads of constructs ranged between 469–491 N and 652–683 N, and 759–995 N and 1252–1600 N for steel and titanium fixations, respectively. FE models accurately and quantitatively correctly predicted experimental results for stiffness (R2=0.96), yield (R2=0.97), and ultimate load (R2=0.97). FE simulations accurately predicted plastic plate bending in osteosynthesis constructs. Construct behavior was predominantly driven by the implant itself, highlighting the importance of modelling correct material properties of metal. The validated FE models could predict subject-specific load bearing capacity of osteosyntheses in vivo in preclinical or clinical studies. Acknowledgements: This study was supported by the AO Foundation via the AOTRAUMA Network (Grant No.: AR2021_03)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 56 - 56
2 Jan 2024
Zderic I Warner S Stoffel K Woodburn W Castle R Penman J Saura-Sanchez E Helfet D Gueorguiev B Sommer C
Full Access

Treatment of both simple and complex patella fractures is a challenging clinical problem. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Twelve pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34C1 or five-part complex AO/OTA 34C3 patella fractures by means of osteotomies, with each fracture model created in six pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws, or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring, or a lateral rim variable angle locking plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full knee extension. Interfragmentary movements were captured via motion tracking. For both fracture types, the longitudinal and shear articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p<0.01. Lateral rim locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 56 - 56
2 Jan 2024
Kaneko Y Minehara H Sonobe T Kameda T Sekiguchi M Matsushita T Konno S
Full Access

The Masquelet technique is a variable method for treating critical-sized bone defects, but there is a need to develop a technique for promoting bone regeneration. In recent studies of bone fracture healing promotion, macrophage-mesenchymal stem cell (MSC) cross-talk has drawn attention. This study aimed to investigate macrophage expression in the induced membrane (IM) of the Masquelet technique using a mouse critical-sized bone defect model. The study involved a 3-mm bone defect created in the femur of mice and fixed with a mouse locking plate. The Masquelet (M) group, in which a spacer was inserted, and the Control (C) group, in which the defect was left intact, were established. Additionally, a spacer was inserted under the fascia of the back (B group) to form a membrane due to the foreign body reaction. Tissues were collected at 1, 2, and 4 weeks after surgery (n=5 in each group), and immunostaining (CD68, CD163: M1, M2 macrophage markers) and RT-qPCR were performed to investigate macrophage localization and expression in the tissues. The study found that CD68-positive cells were present in the IM of the M group at all weeks, and RT-qPCR showed the highest CD68 expression at 1 week. In addition, there was similar localization and expression of CD163. The C group showed lower expression of CD68 and CD163 than the M group at all weeks. The B group exhibited CD68-positive cells in the fibrous capsule and CD163-positive cells in the connective tissue outside the capsule, with lower expression of both markers compared to the M group at all weeks. Macrophage expression in IM in M group had different characteristics compared to C group and B group. These results suggest that the IM differs from the fibrous capsules due to the foreign body reaction, and the macrophage-MSC cross-talk may be involved in Masquelet technique