Background. Postoperative dislocation is one of the main surgical complications and the primary cause for revision surgery after 2-stage implant exchange due to periprosthetic infection of a total hip arthroplasty. Objective. The aims of our study were (1) to determine the incidence of dislocation after two-stage THA reimplantation without spacer placement, (2) to evaluate relevant risk factors for dislocation and (3) to assess the final functional outcome of those patients. Method. We prospectively analyzed 187 patients who underwent a two-stage total hip arthroplasty (THA) revision after being diagnosed with periprosthetic joint infection (PJI) from 2013 to 2019. The mean duration of follow-up was 54.2 ± 24.9 months (>36 months). The incidence of postoperative dislocation and subsequent revision was estimated through Kaplan-Meier curves and potential risk factors were identified using Cox hazard regression. The functional outcome of the patients was assessed using the modified Harris Hip Score (mHHS). Results. The estimated cumulative dislocation-free survival was 87.2% (95% CI: 81.2%-91.3%) with an estimated 10% and 12% risk for dislocation within the first 6 and 12 months, respectively. The use of a dual-mobility construct had no significant impact on the dislocation rate. Increasing body mass index (BMI) (HR=1.11, 95% CI: 1.02-1.19, p=0.011), abductor mechanism impairment (HR=2.85, 95% CI: 1.01-8.01, p=0.047), the extent of elongation of the affected extremity between stages (HR=1.04, 95% CI: 1.01-1.07, p=0.017), the final
Introduction. The management of pathologic fractures (PF) following osteomyelitis (especially acute subtype) has not been widely investigated. This is challenging due to the infection-induced destructive process causing bone architecture defects. Therefore, this study aims to assess a stepwise treatment plan for the acute incidence of PF in long bone following pediatric acute Hematogenous osteomyelitis(AHO) (the most common mechanism in children). Method. This case series was conducted in a tertiary pediatric center. Patients with fracture incidence within the first 10 days after AHO diagnosis were included. Patients’ characteristics were retrospectively reviewed. Result. Nine patients (7 boys, involved bone: the femur(4), tibia(3), Radius(1), and Ulna(1)) were included, with a mean age of 52.56±66.18 months (7-216) and a follow-up time of 11.62±3.61 years (6.5-16 years). The etiology in all patients was hematological(Methicillin-resistant Staphylococcus aureus). Our stepwise treatment plan was as follows:. 1. Intravenous antibiotics until ESR<20, then oral to ESR<5. 2. Debridemnt surgery was performed if abscesses were detected. 3. Fracture type determined initial fixation: external fixation (4 patients, 2 unions) or casting (2 patients, both unions). 4. If the union was not obtained, internal fixation (with (2 patients) or without (2 patients) bone graft) was applied (all obtained union). 5. Circular external fixation was applied if the union was not obtained or
Aims. Congenital pseudarthrosis of the tibia (CPT) has traditionally been a difficult condition to treat, with high complication rates, including nonunion, refractures, malalignment, and
Increasing the accuracy of information provided through X-Rays maximises pre-operative planning. Aim of this project is to determine the necessity of calibration probes that would improve the accuracy of pre-operative templating. This is a retrospective study involving leg length and pelvis X-Rays performed across the NHS Lanarkshire from 01/03/2023 until 31/04/2024. A total of 87 leg length X-Rays were identified, 18 had a calibration probe present. Leg length was measured on each and the X-Rays were calibrated against the existing probe. In 66.7% of cases there was a major
Total hip arthroplasty (THA) for congenital hip dysplasia (CDH) presents a challenge. In high-grade CDH, key surgical targets include cup placement in the anatomical position and leg length equality. Lengthening of more than 4 cm is associated with sciatic nerve injury, therefore shortening osteotomies are necessary. We present our experience of different shortening osteotomies including advantages and disadvantages of each technique. 89 hips, in 61 pts (28 bilateral cases), for high CDH were performed by a single surgeon from 1997 to 2022. 67 patients were female and 22 were male. Age ranged from 38 to 68 yrs. In all patients 5–8cm of
Sequelae of Legg-Calve -Perthes disease (LCPD) and treatment of developmental dysplasia of the hip (DDH) can present a coxa breva or coxa magna deformity, sometimes associated with coxa vara. This unique deformity decreases the efficiency of the abductor mechanism, causing a Trendelenburg gait and hip pain,
The results of total hip arthroplasty (THA) revisions to correct
The August 2024 Hip & Pelvis Roundup. 360. looks at: Understanding perceived
In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component. Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years).Aims
Methods
The June 2024 Foot & Ankle Roundup360 looks at: First MTPJ fusion in young versus old patients; Minimally invasive calcaneum Zadek osteotomy and the effect of sequential burr passes; Comparison between Achilles tendon reinsertion and dorsal closing wedge calcaneal osteotomy for the treatment of insertional Achilles tendinopathy; Revision ankle arthroplasty – is it worthwhile?; Tibiotalocalcaneal arthrodesis or below-knee amputation – salvage or sacrifice?; Fusion or replacement for hallux rigidus?.
This study aims to assess the relationship between history of pseudotumour formation secondary to metal-on-metal (MoM) implants and periprosthetic joint infection (PJI) rate, as well as establish ESR and CRP thresholds that are suggestive of infection in these patients. We hypothesized that patients with a pseudotumour were at increased risk of infection. A total of 1,171 total hip arthroplasty (THA) patients with MoM articulations from August 2000 to March 2014 were retrospectively identified. Of those, 328 patients underwent metal artefact reduction sequence MRI and had minimum two years’ clinical follow-up, and met our inclusion criteria. Data collected included demographic details, surgical indication, laterality, implants used, history of pseudotumour, and their corresponding preoperative ESR (mm/hr) and CRP (mg/dl) levels. Multivariate logistic regression modelling was used to evaluate PJI and history of pseudotumour, and receiver operating characteristic curves were created to assess the diagnostic capabilities of ESR and CRP to determine the presence of infection in patients undergoing revision surgery.Aims
Methods
Background. Total ankle replacements (TARs) are becoming increasingly more common in the treatment of end stage ankle arthritis. As a consequence, more patients are presenting with the complex situation of the failing TAR. The aim of this study was to present our case series of isolated ankle fusions post failed TAR using a spinal cage construct and anterior plating technique. Methods. A retrospective review of prospectively collected data was performed for 6 patients that had isolated ankle fusions performed for failed TAR. These were performed by a single surgeon (IW) between March 2012 and October 2014. The procedure was performed using a Spinal Cage construct and grafting in the joint defect and anterior plating. Our primary outcome measure was clinical and radiographic union at 1 year. Union was defined as clinical union and no evidence of radiographic hardware loosening or persistent joint lucent line at 1 year. Results. The mean follow-up was 37.3 months (SD 13.2). Union was achieved in 5 of the 6 patients (83%). One patient had a non-union that required revision fusion incorporating the talonavicular joint that successfully went on to unite across both joints. Another patient had radiographic features of non-union but was clinically united and asymptomatic and one required revision surgery for a bulky symptomatic lateral malleolus with fused ankle joint. Conclusion. The failing TAR presents a complex clinical situation. After removal of the implant there is often a large defect which if compressed leads to a
Dual-mobility acetabular components (DMCs) have improved total hip arthroplasty (THA) stability in femoral neck fractures (FNFs). In osteoarthritis, the direct anterior approach (DAA) has been promoted for improving early functional results compared with the posterolateral approach (PLA). The aim of this study was to compare these two approaches in FNF using DMC-THA. A prospective continuous cohort study was conducted on patients undergoing operation for FNF using DMC by DAA or PLA. Functional outcome was evaluated using the Harris Hip Score (HHS) and Parker score at three months and one year. Perioperative complications were recorded, and radiological component positioning evaluated.Aims
Methods
There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation. We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75).Aims
Methods
The aim of this study is to evaluate the surgical treatment with the best healing rate for patients with proximal femoral unicameral bone cysts (UBCs) after initial surgery, and to determine which procedure has the lowest adverse event burden during follow-up. This multicentre retrospective study was conducted in 20 tertiary paediatric hospitals in France, Belgium, and Switzerland, and included patients aged < 16 years admitted for UBC treatment in the proximal femur from January 1995 to December 2017. UBCs were divided into seven groups based on the index treatment, which included elastic stable intramedullary nail (ESIN) insertion with or without percutaneous injection or grafting, percutaneous injection alone, curettage and grafting alone, and insertion of other orthopaedic hardware with or without curettage.Aims
Methods
Aims. Pelvic discontinuity is a challenging acetabular defect without a consensus on surgical management. Cup-cage reconstruction is an increasingly used treatment strategy. The present study evaluated implant survival, clinical and radiological outcomes, and complications associated with the cup-cage construct. Methods. We included 53 cup-cage construct (51 patients) implants used for hip revision procedures for pelvic discontinuity between January 2003 and January 2022 in this retrospective review. Mean age at surgery was 71.8 years (50.0 to 92.0; SD 10.3), 43/53 (81.1%) were female, and mean follow-up was 6.4 years (0.02 to 20.0; SD 4.6). Patients were implanted with a Trabecular Metal Revision Shell with either a ZCA cage (n = 12) or a TMARS cage (n = 40, all Zimmer Biomet). Pelvic discontinuity was diagnosed on preoperative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed, with failure defined as revision of the cup-cage reconstruction. Results. The five-year all-cause survival for cup-cage reconstruction was 73.4% (95% confidence interval (CI) 61.4 to 85.4), while the ten- and 15-year survival was 63.7% (95% CI 46.8 to 80.6). Survival due to aseptic loosening was 93.4% (95% CI 86.2 to 100.0) at five, ten, and 15 years. The rate of revision for aseptic loosening, infection, and dislocation was 3/53 (5.7%), 7/53 (13.2%), and 6/53 (11.3%), respectively. The mean
Introduction. Coronal malalignment and
Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct. We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97).Aims
Methods
Aims. Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. Methods. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and
Children with spinal dysraphism can develop various musculoskeletal deformities, necessitating a range of orthopaedic interventions, causing significant morbidity, and making considerable demands on resources. This systematic review aimed to identify what outcome measures have been reported in the literature for children with spinal dysraphism who undergo orthopaedic interventions involving the lower limbs. A PROSPERO-registered systematic literature review was performed following PRISMA guidelines. All relevant studies published until January 2023 were identified. Individual outcomes and outcome measurement tools were extracted verbatim. The measurement tools were assessed for reliability and validity, and all outcomes were grouped according to the Outcome Measures Recommended for use in Randomized Clinical Trials (OMERACT) filters.Aims
Methods