The conversion of previous hip fracture surgery to total hip arthroplasty (CTHA) can be surgically challenging with unpredictable outcomes; reported complication rates vary significantly. This study aimed to establish the medium-term survival and outcomes of CTHA performed following a previous hip fracture surgery. All CTHAs performed at our tertiary orthopaedic institution between January 2008 and January 2020 following previous ipsilateral hip fracture surgery were included. Patients were followed up clinically using Oxford Hip Scores (OHS), and radiologically until death or revision surgery. Postoperative complications, radiological implant failure, and indications for revision surgery were reviewed.Aims
Methods
Unicompartmental knee arthroplasty (UKA) is associated with an accelerated recovery, improved functional outcomes, and retention of anatomical knee kinematics when compared to manual total knee arthroplasty (mTKA). UKA is not universally employed by all surgeons as there is a higher revision risk when compared to mTKA. Robotic arm-assisted (ra) UKA enables the surgeon to position the prosthesis more accurately when compared to manual UKA, and is associated with improved functional outcomes and a lower early revision risk. Non-randomized data suggests that, when compared to mTKA, raUKA has a clinically meaningful greater functional benefit. This protocol describes a randomized controlled trial that aims to evaluate the clinical and cost-effectiveness of raUKA compared to mTKA for individuals with isolated medial compartment osteoarthritis (OA). The total versus robotic-assisted unicompartmental knee arthroplasty (TRAKER) trial is a patient- and assessor-blinded, pragmatic parallel two-arm randomized superiority trial of adults undergoing elective primary knee arthroplasty for primary medial compartment OA at a single NHS hospital (ClinicalTrials.gov NCT05290818). Participants will be randomly allocated on a 1:2 basis to either raUKA or mTKA, respectively. The primary analysis will compare the Oxford Knee Score (OKS) six months after surgery. Secondary outcomes measured at three, six, and 12 months include the OKS, Forgotten Joint Score, patient expectations, EuroQol five-dimension questionnaire (EQ-5D), and EQ-visual analogue scale (EQ-VAS), patient satisfaction, range of motion, postoperative complications, need for further surgery, resource use, and financial costs. Cost-effectiveness will be measured over a ten-year time span. A total of 159 patients will be randomized (n = 53 raUKA vs n = 106 mTKA) to obtain 80% power to detect a five-point difference in OKS between the groups six months after surgery.Aims
Methods
The February 2025 Hip & Pelvis Roundup360 looks at: Postoperative periprosthetic femoral fractures after hip arthroplasty: quantifying the other half of the picture; Hip arthroscopy in patients with borderline dysplasia: how do we know when it will not work?; The morbidly obese patient remains a challenge for arthroplasty surgeons; Unexpected positive cultures in aseptic revision hip and knee arthroplasty: does it make a difference?; Failed spinal anaesthesia in hip and knee arthroplasty surgery; Clinical failure of femoral neck fracture is associated with varus necks; Navigating the angles: how variations in femoral and acetabular versions influence hip pain and treatment; High-tech or hands-on? Similar outcomes in direct anterior total hip arthroplasty.
While cementless fixation offers potential advantages over cemented fixation, such as a shorter operating time, concerns linger over its higher cost and increased risk of periprosthetic fractures. If the risk of fracture can be forecasted, it would aid the shared decision-making process related to cementless stems. Our study aimed to develop and validate predictive models of periprosthetic femoral fracture (PPFF) necessitating revision and reoperation after elective total hip arthroplasty (THA). We included 154,519 primary elective THAs from the Swedish Arthroplasty Register (SAR), encompassing 21 patient-, surgical-, and implant-specific features, for model derivation and validation in predicting 30-day, 60-day, 90-day, and one-year revision and reoperation due to PPFF. Model performance was tested using the area under the curve (AUC), and feature importance was identified in the best-performing algorithm.Aims
Methods
The purpose of this study was to directly compare the Modular Dual Mobility (MDM) Mobile Bearing Hip System (Stryker, USA) and large femoral heads (LFHs) in revision total hip arthroplasties (THAs) at mid-term follow-up, with specific emphasis on survival free of re-revision for dislocation, any re-revision, dislocation, and the risk of metal-related complications. We identified 299 revision THAs performed at a single tertiary care academic institution from March 2011 to July 2014. Aseptic loosening of the acetabular component (n = 65), dislocation (n = 58), and reimplantation as part of a two-stage exchange protocol (n = 57) were the most common reasons for index revision. MDM constructs were used in 123 cases, and LFHs were used in 176 cases. Mean age was 66 years (28 to 93), mean BMI was 31 kg/m2 (18 to 55), and 45% (n = 136) were female. Mean follow-up was seven years (2 to 12).Aims
Methods
Hemiarthroplasty (HA) and total shoulder arthroplasty (TSA) are often the preferred forms of treatment for patients with atraumatic avascular necrosis of the humeral head when conservative treatment fails. Little has been reported about the survival of HA and TSA for this indication. The aim of this study was to investigate the differences in revision rates between HA and TSA in these patients, to determine whether one of these implants has a superior survival and may be a better choice in the treatment of this condition. Data from 280 shoulders with 159 primary HAs and 121 TSAs, which were undertaken in patients with atraumatic avascular necrosis of the humeral head between January 2014 and January 2023 from the Dutch Arthroplasty Register (LROI), were included. Kaplan-Meier survival analysis and Cox regression analysis were undertaken.Aims
Methods
Aims. The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems. Methods. A systematic review of all studies reporting the use of short-length Exeter stems in primary total hip arthroplasty (THA) was undertaken. Survival data, the indication for revision, and patient-reported outcomes were gathered from observational and randomized studies. Studies based on registry data were analyzed separately. Results. The review included nine studies which covered a total of 2,190 short stems. The mean follow-up was 6.4 years (2 to 12) with an all-cause survival of 95.4%. When revisions due to aseptic acetabular loosening were excluded, the survival was 97.7%. Four stems fractured (0.18%). The mean Oxford Hip Score improved from 18.29 (1.33 to 21.6) preoperatively to 41.59 (32.9 to 43.4) at final follow-up. Three studies used data from national registries. A total of 25,895 short stems (offset ≤ 35.5 mm) were used compared with 336,218 standard-length stems. In these studies, short stems had a hazard ratio (HR) for all-cause survival of 1.19 (95% CI 0.96 to 1.43) with a rate of revision per 1,000 component-years of 0.037 compared with 0.035 for standard-length stems. One study from the New Zealand
Cite this article:
Arthroplasty has been shown to generate the most waste among all orthopaedic subspecialties, and it is estimated that hip and knee arthroplasty generate in excess of three million kg of waste annually in the UK. Infectious waste generates up to ten times more CO2 compared with recycled waste, and previous studies have shown that over 90% of waste in the infectious stream is misallocated. We assessed the effect of real-time waste segregation by an unscrubbed team member on waste generation in knee and hip arthroplasty cases, and compared this with a simple educational intervention during the ‘team brief’ at the start of the operating list across two sites. Waste was categorized into five categories: infectious, general, recycling, sharps, and linens. Each category was weighed at the end of each case using a digital weighing scale. At Site A (a tertiary orthopaedic hospital), pre-intervention data were collected for 16 total knee arthroplasy (TKA) and 15 total hip arthroplasty (THA) cases. Subsequently, for ten TKA and ten THA cases, an unscrubbed team member actively segregated waste in real-time into the correct streams. At Site B (a district general hospital), both pre- and post-intervention groups included ten TKA and ten THA cases. The intervention included reminding staff during the ‘team brief’ to segregate waste correctly.Aims
Methods
Aims. Cutibacterium acnes (C. acnes; previously known as Propionibacterium acnes or P. acnes) periprosthetic hip and knee infections are under-reported. While culture contamination with C. acnes occurs, true infections are important to recognize and treat. We sought to describe the demographics and treatment outcomes of patients with C. acnes periprosthetic joint infections (PJIs) of the hip and knee. Methods. Patients with C. acnes PJI between January 2005 and December 2018 were retrospectively reviewed utilizing the institutional total
Hip fractures pose a major global health challenge, leading to high rates of morbidity and mortality, particularly among the elderly. With an ageing population, the incidence of these injuries is rising, exerting significant pressure on healthcare systems worldwide. Despite substantial research aimed at establishing best practice, several key areas remain the subject of ongoing debate. This article examines the latest evidence on the place of arthroplasty in the surgical treatment of hip fractures, with a particular focus on the choice of implant, the use of cemented versus uncemented fixation, and advances in perioperative care. Cite this article:
Aims. The aim of this audit was to assess and improve the completeness and accuracy of the National
The December 2024 Shoulder & Elbow Roundup360 looks at: Predicting recurrence of instability after a primary traumatic anterior shoulder dislocation; Predictors of surgery and long-term outcomes in nonoperative management of full-thickness rotator cuff tears; Reverse shoulder arthroplasty viable despite acquired acromial compromise, but higher infection risk noted; LP-PRP reduces retear rates in rotator cuff repair but shows no functional outcome advantage; Long-term clinical outcomes of arthroscopic supraspinatus tendon repair using the single anchor tension band technique – minimum five-year follow-up; Arthroscopic stabilization for anterior shoulder dislocation shows low recurrence rates regardless of prior dislocations; ORIF outperforms arthroplasty for complex radial head fractures: mid-term outcomes; Routine use of surgical helmet systems may not reduce infection risk in shoulder arthroplasty.
Distal femoral osteotomies (DFOs) are commonly used for the correction of valgus deformities and lateral compartment osteoarthritis. However, the impact of a DFO on subsequent total knee arthroplasty (TKA) function remains a subject of debate. Therefore, the purpose of this study was to determine the effect of a unilateral DFO on subsequent TKA function in patients with bilateral TKAs, using the contralateral knee as a self-matched control group. The inclusion criteria consisted of patients who underwent simultaneous or staged bilateral TKA after prior unilateral DFO between 1972 and 2023. The type of osteotomy performed, osteotomy hardware fixation, implanted TKA components, and revision rates were recorded. Postoperative outcomes including the Forgotten Joint Score-12 (FJS-12), Tegner Activity Scale score, and subjective knee preference were also obtained at final follow-up.Aims
Methods
In 2015, we published the results of our ceramic-on-metal (CoM) total hip arthroplasties (THAs) performed between October 2007 and July 2009 with a mean follow-up of 34 months (23 to 45) and a revision rate of 3.1%. The aim of this paper is to present the longer-term outcomes. A total of 264 patients were reviewed at a mean of 5.8 years (4.6 to 7.2) and 10.1 years (9.2 to 10.6) to determine revision rate, pain, outcome scores, radiological analysis, and blood ion levels. Those who were unwilling or unable to travel were contacted by telephone.Aims
Methods
A review of the literature on elbow replacement found no consistency in the clinical outcome measures which are used to assess the effectiveness of interventions. The aim of this study was to define core outcome domains for elbow replacement. A real-time Delphi survey was conducted over four weeks using outcomes from a scoping review of 362 studies on elbow replacement published between January 1990 and February 2021. A total of 583 outcome descriptors were rationalized to 139 unique outcomes. The survey consisted of 139 outcomes divided into 18 domains. The readability and clarity of the survey was determined by an advisory group including a patient representative. Participants were able to view aggregated responses from other participants in real time and to revisit their responses as many times as they wished during the study period. Participants were able to propose additional items for inclusion. A Patient and Public Inclusion and Engagement (PPIE) panel considered the consensus findings.Aims
Methods
Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA. MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated.Aims
Methods
The survival of humeral hemiarthroplasties in patients with relatively intact glenoid cartilage could theoretically be extended by minimizing the associated postoperative glenoid erosion. Ceramic has gained attention as an alternative to metal as a material for hemiarthroplasties because of its superior tribological properties. The aim of this study was to assess the in vitro wear performance of ceramic and metal humeral hemiarthroplasties on natural glenoids. Intact right cadaveric shoulders from donors aged between 50 and 65 years were assigned to a ceramic group (n = 8, four male cadavers) and a metal group (n = 9, four male cadavers). A dedicated shoulder wear simulator was used to simulate daily activity by replicating the relevant joint motion and loading profiles. During testing, the joint was kept lubricated with diluted calf serum at room temperature. Each test of wear was performed for 500,000 cycles at 1.2 Hz. At intervals of 125,000 cycles, micro-CT scans of each glenoid were taken to characterize and quantify glenoid wear by calculating the change in the thickness of its articular cartilage.Aims
Methods