Advertisement for orthosearch.org.uk
Results 1 - 20 of 481
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1377 - 1384
1 Dec 2024
Fontalis A Yasen AT Giebaly DE Luo TD Magan A Haddad FS

Periprosthetic joint infection (PJI) represents a complex challenge in orthopaedic surgery associated with substantial morbidity and healthcare expenditures. The debridement, antibiotics, and implant retention (DAIR) protocol is a viable treatment, offering several advantages over exchange arthroplasty. With the evolution of treatment strategies, considerable efforts have been directed towards enhancing the efficacy of DAIR, including the development of a phased debridement protocol for acute PJI management. This article provides an in-depth analysis of DAIR, presenting the outcomes of single-stage, two-stage, and repeated DAIR procedures. It delves into the challenges faced, including patient heterogeneity, pathogen identification, variability in surgical techniques, and antibiotics selection. Moreover, critical factors that influence the decision-making process between single- and two-stage DAIR protocols are addressed, including team composition, timing of the intervention, antibiotic regimens, and both anatomical and implant-related considerations. By providing a comprehensive overview of DAIR protocols and their clinical implications, this annotation aims to elucidate the advancements, challenges, and potential future directions in the application of DAIR for PJI management. It is intended to equip clinicians with the insights required to effectively navigate the complexities of implementing DAIR strategies, thereby facilitating informed decision-making for optimizing patient outcomes.

Cite this article: Bone Joint J 2024;106-B(12):1377–1384.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1443 - 1450
1 Dec 2024
Down B Ferguson J Loizou C McNally M Ramsden A Stubbs D Kendal A

Aims

Calcaneal osteomyelitis remains a difficult condition to treat with high rates of recurrence and below-knee amputation, particularly in the presence of severe soft-tissue destruction. This study assesses the outcomes of single-stage orthoplastic surgical treatment of calcaneal osteomyelitis with large soft-tissue defects.

Methods

A retrospective review was performed of all patients who underwent combined single-stage orthoplastic treatment of calcaneal osteomyelitis (01/2008 to 12/2022). Primary outcome measures were osteomyelitis recurrence and below-knee amputation (BKA). Secondary outcome measures included flap failure, operating time, complications, and length of stay.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 7 - 7
22 Nov 2024
Unsworth A McNally M Young B Scarborough M
Full Access

Aims. Bone and joint infections cause significant morbidity, often requiring combination medical and surgical treatment. The presence of foreign material reduces the number of organisms required to cause an infection. The aim of this study was to assess whether there was a difference in the species of organism identified on culture in osteomyelitis compared to prosthetic joint infection. Method. This was a retrospective observational cohort study of patients that had surgical intervention for prosthetic joint infection or osteomyelitis with positive microbial culture between 2019 and 2022. Data including patient demographics, site of injury, BACH score for osteomyelitis and JS-BACH score for prosthetic joint infection, organism classification and antibiotic resistance to vancomycin and gentamicin were extracted from the medical record. Logistic and multiple regressions were used to adjust for potential confounding variables. Results. A total of 445 patients were included in the study; 267 patients with osteomyelitis or fracture-related infection and 177 patients with prosthetic joint infection. The patients with prosthetic joint infection were older (Mean age 70 for PJI; IQR 60-77 vs 56 for OM/FRI; IQR 39-64), more likely to be female (55.6% vs 26.2%) and had a higher BMI and ASA compared to those with osteomyelitis. Symptom duration tended to be longer in osteomyelitis/FRI (p<0.001). Staphylococcus aureus was the most common pathogen isolated in both osteomyelitis (155/267 (58.1%)) and prosthetic joint infection (85/177 (48.9%), followed by other Gram negative pathogens with 77/267 (28.8%) in osteomyelitis and 48/177 (27.1%) in prosthetic joint infection. On multivariate analysis, there was no difference between the rate of Staphylococcus aureus infection between the two groups. The rate of polymicrobial infection was higher in patients with osteomyelitis (92/267 (34.5%)) compared to prosthetic joint infection (38/177 (23.7%), however after adjustment for confounders there was no difference, p = 0.842. There was no difference in the presence of gentamicin resistant organisms or vancomycin resistant Gram positive organisms in osteomyelitis compared to prosthetic joint infection. Conclusion. Causative pathogens are similar in these two common forms of bone and joint infection. There was no significant difference in the identification, presence of polymicrobial infection or gentamicin and vancomycin resistance in organisms isolated in osteomyelitis compared to prosthetic joint infection. This may have implications for empiric antibiotic choice and local antibiotic therapy in the management of bone and joint infection


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 84 - 84
22 Nov 2024
Unsworth A McNally M Scarborough M Young B
Full Access

Aim. Local antibiotics, delivered to the site of infection, achieve high tissue concentrations and are used as an adjunct to systemic therapy. Local gentamicin provides levels well above the minimum inhibitory concentration and may be sufficient on its own, however, the efficacy of single or combination local antibiotics has not been studied. This retrospective study evaluated the effect of combination aminoglycoside and vancomycin local antibiotic treatment compared to aminoglycoside alone in the surgical management of bone infection. Method. We studied patients with microbiologically confirmed osteomyelitis and fracture-related infection, who had implantation of antibiotic carriers as part of their surgical management. Data including patient demographics, type of surgery, microbiological characteristics, BACH score, duration of antibiotic treatment and clinical outcomes were collected. Failure of therapy was a composite of recurrence of infection, continued or new antimicrobial therapy, or reoperation with suspected or confirmed infection at one year after index surgery. Results. There were 266 patients who met the inclusion criteria. Nine patients died before the outcome endpoint at 12 months and five patients were lost to follow up so were excluded. 252 patients were included in the final analysis and were well matched with regard to demographics, BACH score and microbiology. 113 patients had treatment with aminoglycoside alone and 139 patients had combination aminoglycoside and vancomycin. There was no difference in the failure rate between groups; 10/113 (8.8%) in the aminoglycoside alone and 12/139 (8.6%) in the combination group, p = 0.934. There was no difference for reoperation, ongoing suppressive antibiotic use, or clinical suspicion of infection. Multivariate analysis showed that there was no added benefit of combination therapy (OR 1.54: 95%CI 0.59-4.04, p=0.38). BACH score and low BMI were associated with increased risk of failure (BACH OR 3.49: 95%CI 1.13-10.76, p=0.03; Low BMI OR 0.91: 95%CI 0.84-0.99, p-0.037). The form of the carrier material (pellets or injectable paste) had no effect on failure rate (p=0.434). Aminoglycoside resistance (confirmed and presumed) occurred in 39/113 (34.5%) of the aminoglycoside only group and 36/139 (25.9%) of the combination group (p=0.137). The presence of aminoglycoside resistance had no effect on failure rate (OR 0.39: 95%CI 0.05-3.01, p=0.37). Conclusions. Clinical outcome was not improved by the addition of vancomycin to aminoglycoside alone as local therapy for the management of osteomyelitis and FRI. Laboratory measured resistance, using currently accepted breakpoints, may not be relevant in local therapy


Bone & Joint Research
Vol. 13, Issue 10 | Pages 535 - 545
2 Oct 2024
Zou C Guo W Mu W Wahafu T Li Y Hua L Xu B Cao L

Aims

We aimed to determine the concentrations of synovial vancomycin and meropenem in patients treated by single-stage revision combined with intra-articular infusion following periprosthetic joint infection (PJI), thereby validating this drug delivery approach.

Methods

We included 14 patients with PJI as noted in their medical records between November 2021 and August 2022, comprising eight hip and seven knee joint infections, with one patient experiencing bilateral knee infections. The patients underwent single-stage revision surgery, followed by intra-articular infusion of vancomycin and meropenem (50,000 µg/ml). Synovial fluid samples were collected to assess antibiotic concentrations using high-performance liquid chromatography.


Bone & Joint Open
Vol. 5, Issue 9 | Pages 742 - 748
10 Sep 2024
Kodumuri P Joshi P Malek I

Aims

This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices.

Methods

Using a life-cycle assessment approach, we conducted a prospective study on ten cemented and ten hybrid THA cases, evaluating carbon emissions from anaesthetic room to recovery. Scope 1 and scope 2 emissions were considered, focusing on direct emissions and energy consumption. Data included detailed assessments of consumables, waste generation, and energy use during surgeries.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 8 - 8
19 Aug 2024
Kärrholm J Itayem R Angelomenos V Mohaddes M Rogmark C Rolfson O
Full Access

In 2022, approximately 60% of inserted cups and stems in Sweden utilized cemented fixation. Two predominant brands, Refobacin Bone Cement R and Palacos R+G, both incorporating gentamicin, were employed in over 90% of primary cemented Total Hip Arthroplasties (THAs) between 2012 and 2022. This study investigates whether the choice between these cement types affects the risk of revision. The five most frequently used cemented cups and the three most common stems were studied. Inclusion criteria encompassed hips with non-tumour diagnoses, operated through a direct lateral or posterior incision, featuring a 28–36 mm metal or ceramic head. Outcomes were assessed for cup revisions (n=55,457 Refobacin, 37,210 Palacos), stem revisions (n=51,732 Refobacin, 30,018 Palacos), and all-cemented THAs with either brand (n=45,265 Refobacin, 26,347 Palacos). Kaplan-Meier life tables and hazard ratios (HR) utilizing Cox regression were computed, adjusting for age, sex, diagnosis, implant type, femoral head size, and material. Over a 10-year period, the cumulative percent revision with Refobacin was consistently higher than Palacos in all three analyses (cups: Refobacin 2.4 (2.3–2.5), Palacos 2.1 (2.0–2.2); stems: Refobacin 2.6 (2.5–2.7), Palacos 2.1 (2,0–2,2); all-cemented: Refobacin 3.2 (2.9–3.5), Palacos 2.9 (2.6–3.2)). Both unadjusted and adjusted HR were 13–25% lower with Palacos. In the analysis of all-cemented THAs, the adjusted HR for Palacos was 0.85 (0.76–0.95). Separating revisions into infectious and non-infectious reasons revealed a lower risk of infectious revisions with Palacos in all three analyses (all-cemented: adjusted HR infection 0.66 (0.56–0.78); non-infectious 1.10 (0.94–1.28)). Hips cemented with Refobacin may face an increased risk of infection, potentially due to a smaller release of antibiotics into surrounding tissues. Unaccounted factors like different mixing systems or unknown biases could also influence outcomes, emphasizing the need for further investigation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 11 - 11
19 Aug 2024
Hamilton JL Gianotti S Impergre A AbuAlia M Markovics A Jacobs JJ Valle CJD Wimmer MA
Full Access

We created TiO. 2. nanotubes (TNTs) on the surface of titanium (Ti) implants with subsequential loading with gentamicin and chitosan, acting as a control release agent, by electrophoretic deposition (EPD). We hypothesized femoral implants with TNTs loaded with gentamicin and chitosan would localize antibiotic to the implant and surgical site and prevent PJI in a mouse model. Ti-6Al-4V ELI wires underwent TNT surface modification by two-step anodization. EPD was then used to load gentamicin and chitosan onto the Ti wire with surface TNTs. Control Ti wires contained TNTs with EPD of chitosan only. 12-week-old male C57BL/6J mice underwent received a right femoral intramedullary implant followed by inoculation at the surgical site with 1×10. 3. CFUs of bioluminescent Xen36 Staphylococcus aureus (S. aureus). Mice were randomly divided into two implant groups: 1) Gentamicin + Chitosan Group (n=7; experimental group); 2) Chitosan Group (n=7; control group). Outcomes included: 1) Relative S. aureus abundance by bioluminescence imaging; 2) Quantification of S. aureus at the implant and surrounding tissue by colony forming unit (CFU) analysis; 3) Scanning electron microscopy (SEM) for implant bacterial biofilm; 4) Radiographic signs of PJI. Over 14 days assessment following wire implantation and inoculation with S. aureus, the experimental group had no evidence of infection based on i) no increased Xen36 S. aureus bioluminescence signal and ii) no CFUs present. All control had increased bioluminescence signal, above baseline, at all time-points and presence of CFUs. Ti femoral implants modified with surface TNTs and coated with gentamicin and chitosan through EPD prevented PJI in all mice through 14 days. In comparison, all control mice demonstrated evidence of PJI over 14 days. Implants with TNTs and EPD of gentamicin were highly effective in this mouse PJI model


Bone & Joint Research
Vol. 13, Issue 8 | Pages 383 - 391
2 Aug 2024
Mannala GK Rupp M Walter N Youf R Bärtl S Riool M Alt V

Aims. Bacteriophages infect, replicate inside bacteria, and are released from the host through lysis. Here, we evaluate the effects of repetitive doses of the Staphylococcus aureus phage 191219 and gentamicin against haematogenous and early-stage biofilm implant-related infections in Galleria mellonella. Methods. For the haematogenous infection, G. mellonella larvae were implanted with a Kirschner wire (K-wire), infected with S. aureus, and subsequently phages and/or gentamicin were administered. For the early-stage biofilm implant infection, the K-wires were pre-incubated with S. aureus suspension before implantation. After 24 hours, the larvae received phages and/or gentamicin. In both models, the larvae also received daily doses of phages and/or gentamicin for up to five days. The effect was determined by survival analysis for five days and quantitative culture of bacteria after two days of repetitive doses. Results. In the haematogenous infection, a single combined dose of phages and gentamicin, and repetitive injections with gentamicin or in combination with phages, resulted in significantly improved survival rates. In the early-stage biofilm infection, only repetitive combined administration of phages and gentamicin led to a significantly increased survival. Additionally, a significant reduction in number of bacteria was observed in the larvae after receiving repetitive doses of phages and/or gentamicin in both infection models. Conclusion. Based on our results, a single dose of the combination of phages and gentamicin is sufficient to prevent a haematogenous S. aureus implant-related infection, whereas gentamicin needs to be administered daily for the same effect. To treat early-stage S. aureus implant-related infection, repetitive doses of the combination of phages and gentamicin are required. Cite this article: Bone Joint Res 2024;13(8):383–391


Bone & Joint Research
Vol. 13, Issue 7 | Pages 332 - 341
5 Jul 2024
Wang T Yang C Li G Wang Y Ji B Chen Y Zhou H Cao L

Aims

Although low-intensity pulsed ultrasound (LIPUS) combined with disinfectants has been shown to effectively eliminate portions of biofilm in vitro, its efficacy in vivo remains uncertain. Our objective was to assess the antibiofilm potential and safety of LIPUS combined with 0.35% povidone-iodine (PI) in a rat debridement, antibiotics, and implant retention (DAIR) model of periprosthetic joint infection (PJI).

Methods

A total of 56 male Sprague-Dawley rats were established in acute PJI models by intra-articular injection of bacteria. The rats were divided into four groups: a Control group, a 0.35% PI group, a LIPUS and saline group, and a LIPUS and 0.35% PI group. All rats underwent DAIR, except for Control, which underwent a sham procedure. General status, serum biochemical markers, weightbearing analysis, radiographs, micro-CT analysis, scanning electron microscopy of the prostheses, microbiological analysis, macroscope, and histopathology evaluation were performed 14 days after DAIR.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 613 - 622
1 Jun 2024
Shen J Wei Z Wu H Wang X Wang S Wang G Luo F Xie Z

Aims

The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes.

Methods

Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 516 - 521
1 Jun 2024
Al-Hourani K Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 372 - 379
1 Apr 2024
Straub J Staats K Vertesich K Kowalscheck L Windhager R Böhler C

Aims

Histology is widely used for diagnosis of persistent infection during reimplantation in two-stage revision hip and knee arthroplasty, although data on its utility remain scarce. Therefore, this study aims to assess the predictive value of permanent sections at reimplantation in relation to reinfection risk, and to compare results of permanent and frozen sections.

Methods

We retrospectively collected data from 226 patients (90 hips, 136 knees) with periprosthetic joint infection who underwent two-stage revision between August 2011 and September 2021, with a minimum follow-up of one year. Histology was assessed via the SLIM classification. First, we analyzed whether patients with positive permanent sections at reimplantation had higher reinfection rates than patients with negative histology. Further, we compared permanent and frozen section results, and assessed the influence of anatomical regions (knee versus hip), low- versus high-grade infections, as well as first revision versus multiple prior revisions on the histological result at reimplantation. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), chi-squared tests, and Kaplan-Meier estimates were calculated.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 352 - 358
1 Apr 2024
Wilson JM Trousdale RT Bedard NA Lewallen DG Berry DJ Abdel MP

Aims

Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct.

Methods

We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97).


Bone & Joint Research
Vol. 13, Issue 3 | Pages 91 - 100
1 Mar 2024
Yamamoto Y Fukui T Sawauchi K Yoshikawa R Takase K Kumabe Y Maruo A Niikura T Kuroda R Oe K

Aims. Continuous local antibiotic perfusion (CLAP) has recently attracted attention as a new drug delivery system for orthopaedic infections. CLAP is a direct continuous infusion of high-concentration gentamicin (1,200 μg/ml) into the bone marrow. As it is a new system, its influence on the bone marrow is unknown. This study aimed to examine the effects of high-concentration antibiotics on human bone tissue-derived cells. Methods. Cells were isolated from the bone tissue grafts collected from six patients using the Reamer-Irrigator-Aspirator system, and exposed to different gentamicin concentrations. Live cells rate, apoptosis rate, alkaline phosphatase (ALP) activity, expression of osteoblast-related genes, mineralization potential, and restoration of cell viability and ALP activity were examined by in vitro studies. Results. The live cells rate (the ratio of total number of cells in the well plate to the absorbance-measured number of live cells) was significantly decreased at ≥ 500 μg/ml of gentamicin on day 14; apoptosis rate was significantly increased at ≥ 750 μg/ml, and ALP activity was significantly decreased at ≥ 750 μg/ml. Real-time reverse transcription-polymerase chain reaction results showed no significant decrease in the ALP and activating transcription factor 4 transcript levels at ≥ 1,000 μg/ml on day 7. Mineralization potential was significantly decreased at all concentrations. Restoration of cell viability was significantly decreased at 750 and 1,000 μg/ml on day 21 and at 500 μg/ml on day 28, and ALP activity was significantly decreased at 500 μg/ml on day 28. Conclusion. Our findings suggest that the exposure concentration and duration of antibiotic administration during CLAP could affect cell functions. However, further in vivo studies are needed to determine the optimal dose in a clinical setting. Cite this article: Bone Joint Res 2024;13(3):91–100


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 67 - 73
1 Mar 2024
Laboudie P Hallé A Anract P Hamadouche M

Aims

The aim of this retrospective study was to assess the incidence of early periprosthetic femoral fracture (PFF) associated with Charnley-Kerboull (CK) femoral components cemented according to the ‘French paradox’ principles through the Hueter anterior approach (HAA) in patients older than 70 years.

Methods

From a prospectively collected database, all short CK femoral components implanted consecutively from January 2018 to May 2022 through the HAA in patients older than 70 years were included. Exclusion criteria were age below 70 years, use of cementless femoral component, and approaches other than the HAA. A total of 416 short CK prostheses used by 25 surgeons with various levels of experience were included. All patients had a minimum of one-year follow-up, with a mean of 2.6 years (SD 1.1). The mean age was 77.4 years (70 to 95) and the mean BMI was 25.3 kg/m2 (18.4 to 43). Femoral anatomy was classified according to Dorr. The measured parameters included canal flare index, morphological cortical index, canal-calcar ratio, ilium-ischial ratio, and anterior superior iliac spine to greater trochanter (GT) distance.


Bone & Joint 360
Vol. 12, Issue 6 | Pages 17 - 20
1 Dec 2023

The December 2023 Hip & Pelvis Roundup360 looks at: Early hip fracture surgery is safe for patients on direct oral anticoagulants; Time to return to work by occupational class after total hip or knee arthroplasty; Is there a consensus on air travel following hip and knee arthroplasty?; Predicting whether patients will achieve minimal clinically important differences following hip or knee arthroplasty; High-dose dual-antibiotic-loaded cement for hip hemiarthroplasty in the UK (WHiTE 8): a randomized controlled trial; Vitamin E – a positive thing in your poly?; Hydroxapatite-coated femoral stems: is there a difference in fixation?


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 20 - 20
24 Nov 2023
Morin B Tripathi V Iizuka A Clauss M Morgenstern M Baumhoer D Jantarug K Fuentes PR Kuehl R Bumann D Khanna N
Full Access

Aim. Staphylococcus aureus (SA) can cause various infections and is associated with high morbidity and mortality rates of up to 40%. Antibiotic treatment often fails to eradicate SA infections even if the causative strain has been tested susceptible in vitro. The mechanisms leading to this persistence is still largely unknown. In our work, we to reveal SA interactions with host cells that allow SA to persist at the site of infection. Method. We established a sampling workflow to receive tissue samples from patients requiring surgical debridement due to SA bone-and joint or soft-tissue infections. We developed a multiplex immunofluorescent staining protocol which allowed us to stain for SA, leukocytes, neutrophils, macrophages, B-cells, T-cells, DAPI and cytoplasmatic marker on the same sample slide. Further, distance of SA to cell nuclei was measured. Interaction of immune cells and SA on a single cell level was investigated with high-resolution 3D microscopy. We then validated our findings applying fluorescence-activated cell sorting (FACS) on digested patient samples. Finally, we aimed to reproduce our ex vivo patient results in an in vitro co-culture model of primary macrophages and clinical SA strains, where we used live cell microscopy and high-resolution microscopy to visualize SA-immune cell interactions and a gentamicin protection assay to assess viability of SA. Results. Here, we revealed that CD68+ macrophages were the immune cells closest to SA with a mean distance of 56μm (SD=36.4μm). Counting the amount of SA, we found in total >7000 single SA in nine patients. Two-thirds of SA were located intracellularly. Two-thirds of the affected immune cells with intracellular SA were macrophages. The distribution of intra- to extracellular SA was independent of ongoing antibiotic therapy and underlying infection type. FACS confirmed these findings. In our co-culture model, intracellular SA remained alive for the whole observation period of eight hours and resided in RAB5+ early phagosomes. Conclusions. Our study suggests an essential role of intracellular survival in macrophages in SA infections. These findings may have major implication for future treatment strategies


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 63 - 63
24 Nov 2023
Prebianchi SB Santos INM Brasil I Charf P Cunha CC Seriacopi LS Durigon TS Rebouças MA Pereira DLC Dell Aquila AM Salles M
Full Access

Aim. Community-acquired methicillin-resistant Staphylococcus aureus (CA-MRSA) is commonly associated with serious cases of community-onset skin and musculoskeletal infections (Co-SMSI). Molecular epidemiology analysis of CA-MRSA recovered from skin and soft tissues specimens is lacking in Latin America. This study aimed to identify phenotypic and genotypic features of MRSA isolates recovered from patients presenting Co-SMSI. Methods. Consecutive MRSA isolates recovered from Co-SMSI of patients admitted from March 2022 to January 2023 in a Brazilian teaching hospital were tested for antimicrobial resistance and characterized by their genotypic features. Identification was carried out by automated method and through MALDI-TOF MS. Antimicrobial susceptibility was tested by disk diffusion, broth microdilution and E-test strips for determination of the minimal inhibitory concentration (MIC) according to recommendations from the Brazilian Committee on Antimicrobial Susceptibility Testing (BrCAST) and European Committee on Antimicrobial Susceptibility Testing (EUCAST). Gene mecA characterization and Sccmec typing were performed by multiplex polymerase chain reaction (PCR) assay, and gene lukF detection by single PCR. Patients were prospectively followed up for two months, in order to determine their clinical characteristics and outcomes. Results. Overall, 48 Staphylococcus aureus isolates were obtained from 68 samples recovered from patients with Co-SMSI. Twenty two (42%) were phenotypically characterized as MRSA, although mecA gene was only identified in 20 of those samples. Sccmec was untypable in 12 isolates, Sccmec was type II in 4 isolates and 2 were classified as type IVa. LukF gene was identified in 5 isolates. Antimicrobial resistance profile showed that all isolates were susceptible to linezolid and vancomycin with MIC = 1 and MIC = 2 in 66,7% and 33.3%, respectively. Susceptibility to quinolones was worryingly low and none of the isolates were sensitive to usual doses of ciprofloxacin and levofloxacin, and showed increased rates of resistance to increased exposure to these drugs, as well. Isolates were both susceptible to gentamicin and tetracycline in 85% and resistance to also Sulfamethoxazole/Trimethoprim occurred in only 2 isolates. Mortality rate evaluated within 1 month of the initial evaluation was 10% among MRSA isolates. Conclusions. Our results showed that CA-MRSA isolates causing Co-SMSI demonstrated an alarming pattern of multidrug resistance, including to β-lactam and quinolones, which have been commonly prescribed as empirical therapy for patients with skin, soft tissue and musculoskeletal infections


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 32 - 32
24 Nov 2023
Azamgarhi T Warren S Ghert M Gerrand C
Full Access

Aim. Deep infection following endoprosthetic replacement (EPR) of long bones is a devastating complication occurring in 15% of musculoskeletal tumour patients. The recently published PARITY Trial demonstrated that extending antibiotic prophylaxis from 24 hours to 5 days does not reduce infection rates. However, questions remain about the optimal antibiotic choice and dose. Method. A 23-question multiple-choice questionnaire was designed and piloted through an iterative feedback process until the final version was agreed by all authors. Open and closed-ended questions were used to gather information on practice and Likert-type scale responses were used to grade responses to ascertain surgeon perceptions and preferences. The online survey was sent to all surgeon delegates of the 34th Annual Meeting of the European Musculo-Skeletal Oncology Society in London in October 2022. Results. Amongst 61 respondents, 43 were based in Europe and 18 outside of Europe. The majority (48/61) had been in clinical practice over 11 years. Antibiotic choice. 1st or 2nd generation cephalosporins were the first line choice practiced among 49 (80.3%) of respondents. Of these, 39 responded had a 2nd line protocol for beta-lactam allergy which was most commonly clindamycin (18), vancomycin (11) or a combination of a glycopeptide or clindamycin plus gentamicin (4). Respondents changed their first line regimen for radiotherapy in 6/61, chemotherapy in 8/61 and tumour site in 20/61. Re-dosing. Intraoperative re-dosing intervals of 1st and 2nd generation cephalosporins ranged from 2 to 8 hourly. Re-dosing for blood loss ranged from never to when 2 litres was lost. Of the 47 respondents, 24 said intraoperative re-dosing is always reliably administered. Duration. Six (10%) of 61 respondent routinely cover the intraoperative period only, whereas 30 (49%) give 24 hours, 16 (give 48 hours or longer and 8 continue until surgical drains are removed. 31 of 61 change duration depending on clinical situation. The most common reasons for changing were patient risk factors, soft tissue status and previous radiotherapy. 57/61 surgeons were aware of the PARITY Trial. When these respondents were asked whether they had changed practice based on PARITY, 12 said yes, 24 said no and 21 said they always give 24 hours anyway. Conclusions. Amongst an international cohort of orthopaedic oncology surgeons there was a wide variation in practice. Further research should focus on the optimum choice and re-dosing strategy, which have not been defined