Aims. The outcomes of patients with unexpected positive cultures (UPCs) during revision total hip arthroplasty (THA) and total knee arthroplasty (TKA) remain unknown. The objectives of this study were to establish the prevalence and infection-free implant survival in UPCs during presumed aseptic single-stage revision THA and TKA at mid-term follow-up. Methods. This study included 297 patients undergoing presumed aseptic single-stage revision THA or TKA at a single treatment centre. All patients with at least three UPCs obtained during revision surgery were treated with minimum three months of oral antibiotics following revision surgery. The prevalence of UPCs and causative microorganisms, the recurrence of periprosthetic joint infections (PJIs), and the infection-free implant survival were established at minimum five years’ follow-up (5.1 to 12.3). Results. Of the 297 patients undergoing aseptic revisions, 37 (12.5%) had at least three UPCs obtained during surgery. The UPC cohort included 23 males (62.2%) and 14 females (37.8%), with a mean age of 71.2 years (47 to 82). Comorbidities included smoking (56.8%), hypertension (48.6%), diabetes mellitus (27.0%), and chronic renal impairment (13.5%). The causative microorganisms included Staphylococcus epidermidis (49.6%), Bacillus species (18.9%), Micrococcus species (16.2%), and Cutibacterium acnes (16.2%). None of the study patients with UPCs developed further PJIs or required further surgical intervention during follow-up. Conclusion. The prevalence of UPCs during presumed aseptic revision THA and TKA was 12.5%. The most common causative microorganisms were of low virulence, and included S. epidermidis, Bacillus species, Micrococcus species, and C. acnes. Microorganism-specific antibiotic treatment for minimum three months’ duration of UPCs in presumed
Current diagnostic tools are not always able to effectively identify periprosthetic joint infections (PJIs). Recent studies suggest that circulating microRNAs (miRNAs) undergo changes under pathological conditions such as infection. The aim of this study was to analyze miRNA expression in hip arthroplasty PJI patients. This was a prospective pilot study, including 24 patients divided into three groups, with eight patients each undergoing revision of their hip arthroplasty due to aseptic reasons, and low- and high-grade PJI, respectively. The number of intraoperative samples and the incidence of positive cultures were recorded for each patient. Additionally, venous blood samples and periarticular tissue samples were collected from each patient to determine miRNA expressions between the groups. MiRNA screening was performed by small RNA-sequencing using the miRNA next generation sequencing (NGS) discovery (miND) pipeline.Aims
Methods
Prosthetic joint infection (PJI) is a devastating and costly complication of total joint arthroplasty (TJA). Use of extended oral antibiotic prophylaxis (EOAP) has become increasingly popular in the United States following a highly publicized study (Inabathula et al) from a single center demonstrating a significant protective effect (81% reduction) against PJI in ‘high-risk’ patients. However, these results have not been reproduced elsewhere and EOAP use directly conflicts with current antibiotic stewardship efforts. In order to study the role of EOAP in PJI prevention, consensus is needed for what defines ‘high-risk’ patients. The revision TJA (rTJA) population is an appropriate group to study due to having a higher incidence of PJI. The purpose of the current study was to rigorously determine which preoperative conditions described by Inabathula et al. (referred to as Inabathula criteria (IBC)) confer a higher rate of PJI in patients undergoing aseptic rTJA. 2,256 patients that underwent aseptic rTJA at a single high-volume institution between 2016–2022 were retrospectively reviewed. Patient demographics and comorbidities were recorded to determine if they had 1 or more ‘IBC’, a long list of preoperative conditions including autoimmune diseases, active smoking, body mass index (BMI)>35, diabetes mellitus, and chronic kidney disease (CKD). Reoperation for PJI at 90-days and 1-year was recorded. Chi-squared or Fischer's exact tests were calculated to determine the association between preoperative presence/absence of IBC and PJI. Multivariable logistic regressions were conducted to determine if specific comorbidities within the IBC individually conferred an increased PJI risk.Aim
Method
The February 2023 Knee Roundup360 looks at: Machine-learning models: are all complications predictable?; Positive cultures can be safely ignored in revision arthroplasty patients that do not meet the 2018 International Consensus Meeting Criteria; Spinal versus general anaesthesia in contemporary primary total knee arthroplasty; Preoperative pain and early arthritis are associated with poor outcomes in total knee arthroplasty; Risk factors for infection and revision surgery following patellar tendon and quadriceps tendon repairs; Supervised versus unsupervised rehabilitation following total knee arthroplasty; Kinematic alignment has similar outcomes to mechanical alignment: a systematic review and meta-analysis; Lifetime risk of revision after knee arthroplasty influenced by age, sex, and indication; Risk factors for knee osteoarthritis after traumatic knee injury.
Aim. Culture-based conventional methods are still the gold standard to identify microorganisms in hip and knee PJIs diagnosis. However, such approach presents some limitations due to prior antimicrobial treatment or the presence of unusual and fastidious organisms. Molecular techniques, in particular specific real-time and broad-range polymerase chain reaction (PCR), are available for diagnostic use in a suspected PJI. However, limited data is available on their sensitivity and specificity. This study aimed to evaluate the performance of a rapid and simple Investigational Use Only (IUO) version of the BioFire® JI multiplex PCR panel when compared to traditional microbiological procedures. Method. Fifty-eight native synovial fluid samples were recovered from 49 patients (female n=26; male =23) who underwent one or multiple septic or
Periprosthetic joint infections (PJIs) and fracture-related infections (FRIs) are associated with a significant risk of adverse events. However, there is a paucity of data on cardiac complications following revision surgery for PJI and FRI and how they impact overall mortality. Therefore, this study aimed to investigate the risk of perioperative myocardial injury (PMI) and mortality in this patient cohort. We prospectively included consecutive patients at high cardiovascular risk (defined as age ≥ 45 years with pre-existing coronary, peripheral, or cerebrovascular artery disease, or any patient aged ≥ 65 years, plus a postoperative hospital stay of > 24 hours) undergoing septic or aseptic major orthopaedic surgery between July 2014 and October 2016. All patients received a systematic screening to reliably detect PMI, using serial measurements of high-sensitivity cardiac troponin T. All-cause mortality was assessed at one year. Multivariable logistic regression models were applied to compare incidence of PMI and mortality between patients undergoing septic revision surgery for PJI or FRI, and patients receiving aseptic major bone and joint surgery.Aims
Methods
This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant. A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.Aims
Methods
The purpose of this study was to evaluate unexpected positive cultures in total hip arthroplasty (THA) revisions for presumed aseptic loosening, to assess the prevalence of low-grade infection using two definition criteria, and to analyze its impact on implant survival after revision. A total of 274 THA revisions performed for presumed aseptic loosening from 2012 to 2016 were reviewed. In addition to obtaining intraoperative tissue cultures from all patients, synovial and sonication fluid samples of the removed implant were obtained in 215 cases (79%) and 101 cases (37%), respectively. Histopathological analysis was performed in 250 cases (91%). Patients were classified as having low-grade infections according to institutional criteria and Musculoskeletal Infection Society (MSIS) International Consensus Meeting (ICM) 2013 criteria. Low-grade infections according to institutional criteria were treated with targeted antibiotics for six weeks postoperatively. Implant failure was defined as the need for re-revision resulting from periprosthetic joint infection (PJI) and aseptic reasons. The mean follow-up was 68 months (26 to 95).Aims
Methods
Calprotectin (CLP) is produced in neutrophils and monocytes and released into body fluids as a result of inflammation or infection. The aim of this study was to evaluate the utility of blood and synovial CLP in the diagnosis of chronic periprosthetic joint infection (PJI). Blood and synovial fluid samples were collected prospectively from 195 patients undergoing primary or revision hip and knee arthroplasty. Patients were divided into five groups: 1) primary total hip and knee arthroplasty performed due to idiopathic osteoarthritis (OA; n = 60); 2) revision hip and knee arthroplasty performed due to aseptic failure of the implant (AR-TJR; n = 40); 3) patients with a confirmed diagnosis of chronic PJI awaiting surgery (n = 45); 4) patients who have finished the first stage of the PJI treatment with the use of cemented spacer and were qualified for replantation procedure (SR-TJR; n = 25), and 5) patients with rheumatoid arthritis undergoing primary total hip and knee arthroplasty (RA; n = 25). CLP concentrations were measured quantitatively in the blood and synovial fluid using an immunoturbidimetric assay. Additionally, blood and synovial CRP, blood interleukin-6 (IL-6), and ESR were measured, and a leucocyte esterase (LE) strip test was performed.Aims
Methods
To evaluate the histopathological examination of peri-implant tissue samples as a technique in the diagnosis of postoperative spinal implant infection (PSII). This was a retrospective analysis. Patients who underwent revision spinal surgery at our institution were recruited for this study. PSII was diagnosed by clinical signs, histopathology, and microbiological examination of intraoperatively collected samples. Histopathology was defined as the gold standard. The sensitivity for histopathology was calculated. A total of 47 patients with PSII and at least one microbiological and histopathological sample were included in the study.Aims
Methods
Prosthetic joint infection (PJI) remains a major clinical challenge. Neutrophil CD64 index, Fc-gamma receptor 1 (FcγR1), plays an important role in mediating inflammation of bacterial infections and therefore could be a valuable biomarker for PJI. The aim of this study is to compare the neutrophil CD64 index in synovial and blood diagnostic ability with the standard clinical tests for discrimination PJI and aseptic implant failure. A total of 50 patients undergoing revision hip and knee arthroplasty were enrolled into a prospective study. According to Musculoskeletal Infection Society (MSIS) criteria, 25 patients were classified as infected and 25 as not infected. In all patients, neutrophil CD64 index and percentage of polymorphonuclear neutrophils (PMN%) in synovial fluid, serum CRP, ESR, and serum CD64 index levels were measured preoperatively. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were analyzed for each biomarker.Aims
Methods
Vancouver type B periprosthetic femoral fractures (PFF) are challenging complications after total hip arthroplasty (THA), and some treatment controversies remain. The objectives of this study were: to evaluate the short-to-mid-term clinical outcomes after treatment of Vancouver type B PFF and to compare postoperative outcome in subgroups according to classifications and treatments; to report the clinical outcomes after conservative treatment; and to identify risk factors for postoperative complications in Vancouver type B PFF. A total of 97 consecutive PPFs (49 males and 48 females) were included with a mean age of 66 years (standard deviation (SD) 14.9). Of these, 86 patients were treated with surgery and 11 were treated conservatively. All living patients had a minimum two-year follow-up. Patient demographics details, fracture healing, functional scores, and complications were assessed. Clinical outcomes between internal fixation and revisions in patients with or without a stable femoral component were compared. Conservatively treated PPFs were evaluated in terms of mortality and healing status. A logistic regression analysis was performed to identify risk factors for complications.Aims
Methods
We used the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to investigate the risk of revision due to prosthetic joint infection (PJI) for patients undergoing primary and revision hip arthroplasty, the changes in risk over time, and the overall burden created by PJI. We analysed revision total hip arthroplasties (THAs) performed due to a diagnosis of PJI and the linked index procedures recorded in the NJR between 2003 and 2014. The cohort analysed consisted of 623 253 index primary hip arthroplasties, 63 222 index revision hip arthroplasties and 7585 revision THAs performed due to a diagnosis of PJI. The prevalence, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression.Objectives
Methods
Aim. Dissolvable antibiotic-loaded calcium sulphate beads have been utilized for management of periprosthetic joint infection (PJI) and for
Early and/or prolonged wound discharge after total knee arthroplasty often raises the question whether this is a sign of an early infection or if the prolonged discharge leads to a secondary deep wound infection from migrating skin bacteria. Confronted with the dilemma of what to do with early PWC our department implemented a new treatment protocol in 2002 to deal with early PWC after TKA in order to standardize decision-making. The aim of this study was to report our long-term results using this protocol on a prospective cohort primary TKA and revision TKA performed for other reasons than infection. This report focuses on the results of DAIR (debridement, antibiotics and implant retention) performed for early PPJI and/or early wound complications without clinical signs of infection. After implementing our treatment algorithm regarding postoperative wound complications in early 2002, we initiated a quality registration including every primary and non infected revision TKA performed. Between January 2002 and August 2012 1439 consecutive primary knee arthroplasties were performed at our institution. During the same period a total of 120 knee revisions for reasons not related to infection were performed. All patients undergoing DAIR within three months of the index procedure where divided into two groups: successful and unsuccessful. Successful DAIR didn't require any more surgery and the implant could be retained with a minimum follow up time of two years. Unsuccessful DAIR required at least one more surgical intervention. Treatment with DAIR was successful in 47 of 62 patients operated with primary and revision TKA as index operation. Those patients had no signs of infection and no antimicrobial therapy after a minimum of one year follow up time. The remaining 15 patients were in need of further surgery. Positive cultures could be obtained in 41 of 62 patients including those operated for
Total knee arthroplasty is an established and successful operation. In up to 13% of patients who undergo total knee arthroplasty continue to complain of pain. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful total knee arthroplasty. We reviewed 56 painful total knee replacements and compared these to 56 matched patients with pain free total knee replacements. Patients with infection,
This prospective study evaluates the role of new laboratory markers in the diagnosis of deep implant infection in 78 patients (41 men and 37 women) with a revision total knee or hip replacement. The mean age at the time of operation was 64.0 years (19 to 90). Intra-operative cultures showed that 21 patients had a septic and 57 an aseptic total joint replacement. The white blood cell count, the erythrocyte sedimentation rate and levels of C-reactive protein, interleukin-6, procalcitonin and tumour necrosis factor (TNF)-α were measured in blood samples before operation. The diagnostic cut-off values were determined by Received Operating Characteristic curve analysis. C-reactive protein (>
3.2 md/dl) and interleukin-6 (>
12 pg/ml) have the highest sensitivity (0.95). Interleukin-6 is less specific than C-reactive protein (0.87 The combination of C-reactive protein and interleukin-6 measurement provide excellent screening tests for infection of a deep implant. A highly specific marker such as procalcitonin and pre-operative aspiration of the joint might be useful in identifying patients with true positive C-reactive protein and/or interleukin-6 levels.
Introduction and Aims: Functional results following revision total hip arthroplasty (THA) for infection may be inferior to those done for aseptic causes. This cross-sectional study compared the results of patients who had two-stage revision for infection using an articulating spacer device, with those of a control group who had revision for aseptic causes. Method: Patients admitted between December 1997 and December 2000 for two-stage revision of an infected hip replacement using the PROSTALAC articulating spacer were included. They were compared to patients who had revision of both components for aseptic causes over the same time period. Patients with periprosthetic fractures were excluded. Pre-operative function was assessed using the Charnley score and bone loss was determined from pre-operative radiographs using the Paprowsky femoral and acetabular classifications. At a minimum two years follow-up, quality of life (QOL) was assessed using the WOMAC, Oxford-12 and SF-12 questionnaires. Patient satisfaction and co-morbidity data were also collected. Results: There were 44 septic and 105
Aims: The aim of this study was to investigate the functional results and complications of the total femur prosthesis Endo-Model?. Material and methods:100 total femurs implanted between 3/89 and 9/97 during