Advertisement for orthosearch.org.uk
Results 1 - 20 of 102
Results per page:
Bone & Joint 360
Vol. 13, Issue 2 | Pages 8 - 12
1 Apr 2024
Craxford S


Bone & Joint 360
Vol. 13, Issue 1 | Pages 7 - 8
1 Feb 2024
Jamal B Round J Qureshi A


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 22 - 22
1 Jun 2023
North A Stratton J Moore D McCann M
Full Access

Introduction. External fixators are attached to bones with percutaneous pins and wires inserted through soft tissues and bone increasing the risk of infections. Such infections compromise patient outcomes e.g., through pin loosening or loss, failure of fixator to stabilise the fracture, additional surgery, increased pain, and delayed mobilisation. These infections also impact the healthcare system for example, increased OPD visits, hospitalisations, treatments, surgeries and costs. Nurses have a responsibility in the care and management of patients with external fixators and ultimately in the prevention of pin-site infection. Yet, evidence on best practices in the prevention of pin-site infection is limited and variation in pin-site management practices is evident. Various strategies are used for the prevention of pin-site infection including the use of different types of non-medicated and medicated wound dressings. The aim of this retrospective study was to investigate the use of dry gauze or iodine tulle dressings for the prevention of pin-site infections in patients with lower limb external fixators. Methodology. A retrospective study of patients with lower limb external fixators who attended the research site between 2015–2022. Setting & Sample: The setting was the outpatient's (OPD) orthopaedic clinic in a University Teaching Hospital in Dublin, Ireland. Eligibility Criteria:. Over the age of 16, treated with an Ilizarov, Taylor Spatial frame (TSF) or Limb Reconstruction System (LRS) external fixators on lower limbs,. Pin-sites dressed with dry gauze or iodine tulle,. Those with pre-existing infected wounds close to the pin site and/or were on long term antibiotics were excluded. Follow Up Period: From time of external fixator application to first pin-site infection or removal of external fixator. Outcome Assessment: The primary outcome was pin-site infection, secondary outcomes included but were not limited to frequency of pin-site infection according to types of bone fixation, frequency of pin/wire removal and hospitalisation due to infection. Data analysis: IBM SPSS Version 25 was used for statistical analysis. Descriptive and inferential statistics were conducted as appropriate. Categorical data were analysed by counting the frequencies (number and percentages) of participants with an event as opposed to counting the number of episodes for each event. Differences between groups were analysed using Chi-square test or Fisher's exact test, where appropriate. Continuous variables were reported using mean and standard deviations and difference analysed using a two-sample independent t-test or non-parametric test (Mann-Whitney), where appropriate. Using Kaplan-Meier, survival analysis explored time to development of infection. Ethical approval: granted by local institute Research Ethics Committee on 12th March 2018. Results. During the study period, 97 lower limb external fixators were applied with 43 patients meeting the study eligibility criteria. The mean age was 38 (SD 14.1; median 37) and the majority male (n=32, 74%). At least 50% (n=25) of participants had an IIizarov fixator, with 56% (n=24) of all fixators applied to the tibia and fibula. Pin/wire sites were dressed using iodine (n=26, 61%) or dry gauze dressings (n=15, 35%). The mean age of participants in the iodine group was significantly higher than the dry gauze group (p=.012). The only significant difference between the iodine and dry gauze dressing groups at baseline was age. A total of 30 (70%) participants developed a pin-site infection with 26% (n=11) classified as grade 2 infection. Clinical presentation included redness (n=18, 42%), discharge (n=16, 37%) and pain (n=15, 35%). Over half of participants were prescribed oral antibiotics (n=28, 65%); one required intravenous antibiotics and hospitalization due to pin-site infection. Ten (23%) participants required removal of pin/wires; two due to pin-site infection. There was no association between baseline data and pin-site infection. The median time to developing an infection was 7 weeks (95%, CI 2.7 to 11.29). Overall, there were 21 (81%, n=26) pin-site infections in the iodine group and nine (60%, n=15) in the dry gauze group, difference in proportion and relative risk between the dressing groups were not statistically significant (RR 1.35, 95% CI 0.86–2.12; p= .272). There was no association between baseline data, pin-site infection, and type of dressing. Conclusions. At the research site, patients are referred to the OPD orthopaedic clinic from internal and external clinical sites e.g., from Hospital Consultants, General Practitioners and occasionally from multidisciplinary teams, throughout Ireland. Our retrospective observation study found that 97 lower limb external fixators were applied over a seven-year period which is lower than that reported in the literature. However, the study period included the COVID pandemic years (2020 and 2021) which saw a lower number of external fixators applied due to lack of theatre availability, cancelled admissions and social/travel restrictions that resulted in fewer accidents and lower limb trauma cases requiring external fixator application. The study highlighted a high infection rate with 70% of participants developing pin-site infection which is in keeping with findings reporting in other studies. Our study showed that neither an iodine nor dry gauze dressing was successful in preventing pin-site infection. In the iodine group 81% of participants developed infection compared to 60% in the dry gauze group. Given the lack of difference between the two groups consideration needs to be given to the continued use of iodine dressings in the prevention of pin-site infection. Pin-site infections result in a high portion of participants being prescribed antibiotics and, in an era, that stresses the importance of antimicrobial stewardship there is a need to implement effective infection prevention and control strategies that minimise infection. Further research is therefore needed to investigate more innovative medicated dressings such as those that contain anti-microbial or anti-bacterial agents


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 116 - 116
4 Apr 2023
Zhang J Zhu J Zhou A Thahir A Krkovic M
Full Access

Treatment of tibial osteomyelitis can be challenging and lengthy, with numerous complications possible during rehabilitation. We report on the usage of the Taylor Spatial Frame (TSF) for a large cohort of patients, and analyse factors that affect outcomes. Between 2015-2020, 51 patients were treated with TSF for osteomyelitis at a major trauma centre. Demographic, infection and treatment factors of: age, smoking status, diabetes, and BMI, acute (<6 weeks post injury) or chronic (>6 weeks) osteomyelitis, bacteria isolated, time to debridement, therapy/surgery number of TSF, time TSF was in, antibiotic treatment period, time to partial weight bear (PWB) and full weight bear (FWB) prescriptions, were collected. Outcomes of complications and time to union were obtained. Radiological union was achieved at mean 11.0 months. Mean follow up was 24.1 months. Six and three patients were further treated with fusion and amputation respectively. Mean treatment time with TSF was 12.1 months. 78% had some complications, with pin site infection, malunion, and non-union being most prevalent. Univariate factor analysis, multicollinearity diagnostics, then multivariate model construction were performed. Staphylococcus Epidermidis in bone debridement microbiology was significantly negatively associated with pin site infection (OR 0.093, 95% CI 0.011-0.828) and malunion (OR 0.698, 95% CI 0.573-0.849), and enterococcus with non-union (OR 0.775, 95% CI 0.656-0.916), during the treatment period. Time to union was significantly positively associated with time from admission to debridement (p=0.035), time TSF was in (p=0.021), presence of complications (p=0.045), bone loss complication(p=0.037), time to FWB prescription(p=0.001). We have analysed the effectiveness of TSF in the treatment of tibial osteomyelitis, and elucidated important injury, treatment and rehabilitation factors that affect outcome. The negative bacterial-complication cross associations could be due to successful eradication as culture specific antibiotics were used postoperatively. Earlier patient full weight bearing could enhance callous formation leading to faster union


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1273 - 1278
1 Nov 2022
Chowdhury JMY Ahmadi M Prior CP Pease F Messner J Foster PAL

Aims

The aim of this retrospective cohort study was to assess and investigate the safety and efficacy of using a distal tibial osteotomy compared to proximal osteotomy for limb lengthening in children.

Methods

In this study, there were 59 consecutive tibial lengthening and deformity corrections in 57 children using a circular frame. All were performed or supervised by the senior author between January 2013 and June 2019. A total of 25 who underwent a distal tibial osteotomy were analyzed and compared to a group of 34 who had a standard proximal tibial osteotomy. For each patient, the primary diagnosis, time in frame, complications, and lengthening achieved were recorded. From these data, the frame index was calculated (days/cm) and analyzed.


Bone & Joint Research
Vol. 11, Issue 8 | Pages 541 - 547
17 Aug 2022
Walter N Hierl K Brochhausen C Alt V Rupp M

Aims

This observational cross-sectional study aimed to answer the following questions: 1) how has nonunion incidence developed from 2009 to 2019 in a nationwide cohort; 2) what is the age and sex distribution of nonunions for distinct anatomical nonunion localizations; and 3) how high were the costs for surgical nonunion treatment in a level 1 trauma centre in Germany?

Methods

Data consisting of annual International Classification of Diseases (ICD)-10 diagnosis codes from German medical institutions from 2009 to 2019, provided by the Federal Statistical Office of Germany (Destatis), were analyzed. Nonunion incidence was calculated for anatomical localization, sex, and age groups. Incidence rate ratios (IRRs) were determined and compared with a two-sample z-test. Diagnosis-related group (DRG)-reimbursement and length of hospital stay were retrospectively retrieved for each anatomical localization, considering 210 patients.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 22 - 22
1 Apr 2022
France J Tucker A Norrish A Taylor A Ollivere B
Full Access

Introduction. The use of the Taylor Spatial Frame (TSF) in the management of tibial fractures and deformity correction is well established in the literature, however the majority of published papers are small in patient number. The aim of the project was to evaluate clinical and radiographic outcomes of patients with tibial fractures treated with a TSF. Materials and Methods. A retrospective analysis of patient records and radiographs was performed to obtain patient data, information on injury sustained, the operative technique used, frame construct, time duration in frame, union rates and complications of treatment. Results. In total, 111 tibial fractures managed with a TSF between 2009 and 2020 were reviewed. 55 were open fractures and 56 were closed. Overall union rate was 93.5%. Average time spent in the frame was 27.9 weeks. Complications included 4.6% deep infection rate, 3.7% of patients required component exchange and 8.3% required frame adjustment in theatre. Conclusions. The TSF is an effective way of managing tibial fractures. Our data has found high union rates when used in the management of both closed and open injuries with a low complication rate. Further data collection and analysis will help to aid the patient experience and clinical practice


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 44 - 44
1 May 2021
Zenios M Oyadiji T Zamini-Farahani A
Full Access

Introduction. In my paediatric Orthopaedic practice I use Kirchner wires for the fixation of the TSF on bone. I noted a significant percentage of wire loosening during the post-operative period. The aim of this project was to establish the effectiveness of the wire clamping mechanism and find ways to reduce the incidence of wire loosening when using the TSF. Materials and Methods. In the first instance wire slippage was measured intra-operatively after the tensioner was removed using an intra-operative professional camera. Following this study mechanical tests were performed in the lab measuring the pull out properties of Kirchner wires using different bolts and different torque levels in order to tighten the wire on the fixator. Results. Our clinical study confirmed wire slippage intra-operatively immediately after the tensioner was removed. Wire slippage after the tensioner was removed was found to vary from 0.01 mm to 0.51 mm (mean 0.19 mm). Our mechanical tests showed that the ideal torque for tightening the wire on the frame using a bolt was around 15 N.m. A comparison between cannulated and slotted bolts suggested that cannulated bolts are more effective as a clamping mechanism. A comparison between aluminium made Taylor Spatial frame rings and stainless steel made Ilizarov rings suggested that the Taylor Spatial frame rings are more effective as part of a clamping mechanism. Conclusions. It is important that clinicians routinely measure the torque they use to clamp wires on circular external fixators. Clinicians and manufacturers are informed that the type of bolt used is important in maintaining wire tension. Manufacturers should design the ideal bolt which effectively grips the wire without the risk of fracture. The Ilizarov frame clamping mechanism can be effectively used with the Taylor Spatial frame


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 7 - 7
1 May 2021
Hogg J Madan S
Full Access

Introduction. Torsional malalignment syndrome (TMS) is a unique combination of rotational deformities in the lower limb, often leading to severe patellofemoral joint pain and disability. Surgical management of this condition usually consists of two osteotomies in each affected limb, with simultaneous correction of both femoral anteversion and external tibial torsion. However, we believe that a single supratubercular osteotomy followed by tibial derotation with the Taylor Spatial Frame (TSF) can be used to provide a significant improvement in both appearance and function. Materials and Methods. This is a retrospective case analysis in which we will be reviewing 16 osteotomies performed by one surgeon between 2006 and 2017. The study includes 11 patients with a mean age of 16.7 ± 0.8 years. Pre and post-operatively, patients were fully evaluated through history and physical examination, and CT rotational profiling. Statistical analyses were performed in order to determine whether or not any observed clinical or cosmetic improvements were statistically significant. Results. The results show significant improvements in scores reported on post-operative functional assessment, with mean Oxford Knee Score (OKS) increasing by 18.3 and mean Kujala Anterior Knee Pain Scale (AKPS) also increasing by 31.4. In addition to this, post-operative clinical assessment showed a reduced thigh-foot angle (TFA) in all cases, by a mean value of 31.9o. The angle of the transmalleolar axis (TMA) was successfully reduced in 14/16 cases, by a mean value of 8.6o. Statistical analysis showed all of these results to be statistically significant where p<0.05. Conclusions. The results show that supratubercular osteotomy, followed by gradual correction with TSF, can be used to provide a significant improvement in both appearance and function for patients suffering from TMS


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 45 - 45
1 May 2021
Zenios M Oyadiji T Zamani-Farahani A
Full Access

Introduction. A clinical case of catastrophic ring failure in a 13 year old autistic overweight patient during treatment for tibial lengthening and deformity using a Taylor Spatial Frame is reported. Ring failure was noted during the later stages of bone healing and the frame was removed. The clinical outcome was not affected by the catastrophic ring failure. The photograph of the deformed ring is presented below:. Materials and Methods. The patient's notes and X-rays were reviewed and a macroscopic examination of the deformed ring was performed. Mechanical tests of different Taylor Spatial frame constructs were performed in an attempt to simulate the deformity that was clinically observed. Different constructs of TSF of different ring sizes were fixed to polyurethane cylinders simulating bone, were mechanically tested to failure and load/deflection curves were produced. Results. Macroscopically the ring looked otherwise normal. Gradual mechanical compression tests of Taylor Spatial frame constructs showed that ring deformation increased by increasing the ring diameter and by using jointed rather than full joints without a ring. The ring deformation observed clinically was reproduced at the lab by applying high loads on frame constructs composed of large diameter jointed rings not rigidly fixed to bone. Conclusions. Taylor Spatial frame ring failure during treatment is a serious complication that has not been described in the literature. Possible causes are discussed. Clinicians are advised to use the smaller possible diameter rings. Where large diameter rings are required, these rings should preferably be not jointed. Half rings when used should be carefully and securely joined together by the operating surgeon in order to make a complete ring. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 2 - 2
1 May 2021
Tofighi M Somerville C Lahoti O
Full Access

Introduction. Open fractures are fortunately rare but pose an even greater challenge due to poor soft tissues, in addition to poor bone quality. Co-morbidities and pre-existing medical conditions, in particular, peripheral vascular diseases make them often unsuitable for free flaps. We present our experience in treating severe open fractures of tibia with Acute Intentional Deformation (AID) to close the soft tissues followed by gradual correction of deformity to achieve anatomical alignment of the tibia and fracture healing with Taylor Spatial Frame. Materials and Methods. We treated 4 geriatric (3 female and 1 male) patients with Gustillo-Anderson III B fractures of the tibia between 2017–18. All were unfit to undergo orthoplastic procedures (free flap or local flaps). The age range is 69 yrs to 92 years. Co-morbidities included severe rheumatoid arthritis, multiple sclerosis and heart failure. The procedure involved wound debridement, application of two ring Taylor Spatial Frame, acute deformation of the limb on the table to achieve soft-tissue closure/approximation. Regular neurovascular assessments were performed in the immediate post-operative period to monitor for compartment syndrome and nerve compression symptoms. After 7–10 days of latent period, the frame was gradually manipulated, according to a method we had previously published, to achieve anatomical alignment. The frame was removed in clinic after fracture healing. Results. Time in frame ranged from 1.5 months to 7 months. In one patient (92 yr old with an open fracture of the ankle) hindfoot nail was inserted after soft-tissue closure was achieved at 1.5 months, and frame removed. We achieved complete healing of soft tissue wounds without any input from plastic surgeons in all patients. All fractures healed in anatomical alignment. 3 patients had one episode of superficial pin infection each requiring 5 days of oral antibiotics. None of the patients developed a deep infection. Conclusions. Acute intentional deformation (AID) with Taylor Spatial Frame achieves good closure of soft tissues in physiologically compromised geriatric patients who were deemed unfit for plastic surgery. We also achieved fracture healing in all four cases without any major complications


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 3 - 3
1 May 2021
Lahoti O Abhishetty N Shetty S
Full Access

Introduction. Charcot Arthropathy related foot and ankle deformities are a serious challenge. Surgical treatment of these deformities is now well established. The traditional surgical method of extensive surgical exposure, excision of bone, acute correction and internal fixation is not always appropriate in presence of active ulceration, deep infection and poor bone quality. Minimally invasive osteotomies and gradual correction of deformities with a circular frame are proving helpful in minimizing complications. We present our experience with the use of Taylor Spatial Frame (TSF) in 10 patients with recurrent ulceration and deformity. Materials and Methods. Our indication for the treatment with TSF is recurrent or intractable ulceration with or without active bone infection or a history of infection in a deformed foot and/or ankle. There are 2 female and 8 male patients in this cohort. We used a long bone module for ankle and hindfoot deformities (3 patients) and a forefoot 6×6 butt frame (7 patients) for midfoot deformities. An osteotomy through midfoot was performed in all chronic stable midfoot deformity cases and a calcaneal osteotomy and gradual correction through ankle in when hindfoot and ankle deformities co-existed. Results. Our outcome measures are a complete healing of ulcer and infection without recurrence, clinically plantigrade foot and ability to wear regular shoes or diabetic footwear. We achieved this outcome in 9 out of 10 patients. Successful patients remain ulcer free at minimum 7 and maximum 14 years follow up. Complications included eight episodes of pin infection that responded to oral antibiotics only and two pin breakages. Conclusions. Our results confirm that Taylor Spatial Frame treatment is a good alternative to traditional surgery in high-risk complex Charcot neuroarthropathy foot and ankle deformities


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 42 - 42
1 Feb 2021
Wright J Gehrke C Mallow M Savage P Wiater P Huber C Baker E
Full Access

Introduction. Pin-tract infections are a common problem in orthopaedic surgery, which limits the time an external fixator or Taylor spatial frame can be applied to a patient. The purpose of our study is to evaluate the ability of a novel implant surface coating — cationic steroid antibiotic (CSA)-44 — to delay or prevent the onset of these infections. This coating mimics endogenous antimicrobial peptides of the innate immune system and has been shown to effectively eradicate biofilms as well as prevent infection and stimulate healing of open, contaminated fractures. Methods. Surgeries were performed on 20 animals (outbred; Sprague-Dawley strain rats). Each animal received both CSA-coated and standard-of-care titanium pins, with pins randomized to the fifth or sixth vertebrae prior to surgeries. Animals were also randomized to either “Imaging” (imaging analysis) or “Infection” (microbiological analysis) cohorts. Surgeons were blinded to pin types and analyses cohorts. Digital images of pin sites were collected weekly over 12 weeks, and then graded by two orthopaedic surgery residents according to an established Likert scale. Graders were blinded to animal numbers, pin types, and timepoints (Figure 1). For the infection analysis cohort, four specimens per site were subjected to microbiological analysis from each site (i.e. pin, superficial skin swab, deep skin swab, sonicated bone). Each specimen was processed on three different microbiological plates (i.e. BAP, CAN, MAC) using standardized techniques. Imaging analysis was performed by dissecting vertebrae en bloc with pin retained, followed by fixation in 10% neutral buffered formalin for 72 hours. Following a graded ethanol series and storage in 70% ethanol, specimens were scanned with microcomputed tomography (µCT). Statistical analyses were performed to compare pin site appearance (chi-square testing) as well as total bacterial colony counts within each plate cohort and imaging data (Kruskal-Wallis testing); for all tests, significance was set at α=0.05. Results. Weekly digital images of each pin site were collected, graded, and then averaged (Figure 2). Statistical analysis showed no significant difference in pin appearance between the control and CSA pin cohorts at any timepoints. For the infection analysis cohort, bacterial colonies were counted on BAP, CAN, and MAC plates, followed by bacteria species identification (Figure3). Statistical analysis showed no significant difference in total bacterial colony counts between the control and CSA pin cohorts in any of the plate groups. For the imaging cohort, post-processing and subsequent data and statistical analyses are ongoing. Discussion. No significant differences were found between the control and CSA pin cohorts, with respect to pin appearance during the 12-week study or total bacterial colony counts on three plates, indicating that the control and CSA pins performed equivalently. Imaging analysis is ongoing. Although the environmentally-acquired infection model in an outbred rat strain was used to replicate the onset of pin tract infections in human populations, many animals showed Grade 1 or 2 pin site appearances at the 12-week endpoint. A follow-on study is underway using a direct bacterial seeding model. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1248 - 1255
1 Sep 2020
Laufer A Frommer A Gosheger G Roedl R Broeking JN Toporowski G Rachbauer AM Vogt B

Aims

The treatment of tibial aplasia is controversial. Amputation represents the gold standard with good functional results, but is frequently refused by the families. In these patients, treatment with reconstructive limb salvage can be considered. Due to the complexity of the deformity, this remains challenging and should be staged. The present study evaluated the role of femoro-pedal distraction using a circular external fixator in reconstructive treatment of tibial aplasia. The purpose of femoro-pedal distraction is to realign the limb and achieve soft tissue lengthening to allow subsequent reconstructive surgery.

Methods

This was a retrospective study involving ten patients (12 limbs) with tibial aplasia, who underwent staged reconstruction. During the first operation a circular hexapod external fixator was applied and femoro-pedal distraction was undertaken over several months. Subsequent surgery included reconstruction of the knee joint and alignment of the foot.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1168 - 1176
1 Sep 2019
Calder PR McKay JE Timms AJ Roskrow T Fugazzotto S Edel P Goodier WD

Aims

The Precice intramedullary limb-lengthening system has demonstrated significant benefits over external fixation lengthening methods, leading to a paradigm shift in limb lengthening. This study compares outcomes following antegrade and retrograde femoral lengthening in both adolescent and adult patients.

Patients and Methods

A retrospective review of prospectively collected data was undertaken of a consecutive series of 107 femoral lengthening operations in 92 patients. In total, 73 antegrade nails and 34 retrograde nails were inserted. Outcome was assessed by the regenerate healing index (HI), hip and knee range of movement (ROM), and the presence of any complications.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 241 - 245
1 Mar 2019
Leaver T Johnson B Lampard J Aarvold A Uglow M

Aims. The aim of this study was to quantify the risk of developing cancer from the exposure to radiation associated with surgery to correct limb deformities in children. Patients and Methods. A total of 35 children were studied. There were 19 girls and 16 boys. Their mean age was 11.9 years (2 to 18) at the time of surgery. Details of the radiological examinations were recorded during gradual correction using a Taylor Spatial Frame. The dose area product for each radiograph was obtained from the Computerised Radiology Information System database. The effective dose in millisieverts (mSv) was calculated using conversion coefficients for the anatomical area. The lifetime risk of developing cancer was calculated using government-approved Health Protection Agency reports, accounting for the age and gender of the child. Results. Correction was undertaken in five femurs, 18 tibiae, and 12 feet. The median duration of treatment was 45 months (11 to 118). The mean effective dose was 0.31 mSv (0.05 to 0.64) for the femur, 0.29 mSv (0.01 to 0.97) for the tibia, and 0.027 mSv (0.001 to 0.161) for the foot. The cumulative exposure gave ‘negligible’ risk in 26 children and ‘minimal’ risk in nine children, according to Public Health England categories. These results are below the mean annual background radiation in the United Kingdom. Conclusion. The lifetime attributable risk of developing cancer from repeated exposure to radiation was negligible or minimal in all children. This is the first study to quantify the exposure to radiation from serial radiographs in children with limb deformities who are treated surgically using circular external fixation, linking this to the risk of developing cancer. Cite this article: Bone Joint J 2019;101-B:241–245


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 162 - 169
1 Feb 2019
Catagni MA Azzam W Guerreschi F Lovisetti L Poli P Khan MS Di Giacomo LM

Aims

Many authors have reported a shorter treatment time when using trifocal bone transport (TFT) rather than bifocal bone transport (BFT) in the management of long segmental tibial bone defects. However, the difference in the incidence of additional procedures, the true complications, and the final results have not been investigated.

Patients and Methods

A total of 86 consecutive patients with a long tibial bone defect (≥ 8 cm), who were treated between January 2008 and January 2015, were retrospectively reviewed. A total of 45 were treated by BFT and 41 by TFT. The median age of the 45 patients in the BFT group was 43 years (interquartile range (IQR) 23 to 54).


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 178 - 188
1 Feb 2019
Chaudhary MM Lakhani PH

Aims

Double-level lengthening, bone transport, and bifocal compression-distraction are commonly undertaken using Ilizarov or other fixators. We performed double-level fixator-assisted nailing, mainly for the correction of deformity and lengthening in the same segment, using a straight intramedullary nail to reduce the time in a fixator.

Patients and Methods

A total of 23 patients underwent this surgery, involving 27 segments (23 femora and four tibiae), over a period of ten years. The most common indication was polio in ten segments and rickets in eight; 20 nails were inserted retrograde and seven antegrade. A total of 15 lengthenings were performed in 11 femora and four tibiae, and 12 double-level corrections of deformity without lengthening were performed in the femur. The mean follow-up was 4.9 years (1.1 to 11.4). Four patients with polio had tibial lengthening with arthrodesis of the ankle. We compared the length of time in a fixator and the external fixation index (EFI) with a control group of 27 patients (27 segments) who had double-level procedures with external fixation. The groups were matched for the gain in length, age, and level of difficulty score.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 22 - 22
1 May 2018
Fenton C Henderson D Cherkashin A Samchukov M Sharma HK
Full Access

Aim. To investigate the biomechanical behaviours of the TL-Hex & Taylor Spatial Frame (TSF) Hexapod external fixators, with comparison to traditional ring-fixator constructs. Methods. Standardised four-ring TL-Hex and TSF constructs, as well as matched ilizarov threaded-rod constructs for each set of components, were tested alone and mounted with an acrylic bone model with simulated fracture gap using fine-wires. Load-deformation properties for each construct and mode of loading were calculated and analysed statistically using ANOVA. Results and Conclusions. Under axial loading the Ilizarov construct utilising TL-Hex components demonstrated greatest rigidity followed by the TL-Hex Ilizarov using TSF components (p<0.01). Under torsional loading both hexapod frames were seen to be significantly more rigid than the Ilizarov (p<0.01), with the TSF demonstrating greater rigidity than the TL-Hex. Under cantilever bending loads the difference in rigidity seen across all constructs was less marked. When loaded with the bone model both hexapods demonstrated reduced axial rigidity as compared to Ilizarov constructs, but without any appreciable difference in translational shear strain. Under cantilever bending the Ilizarov construct using TL-Hex components p<0.01) demonstrated less translational shear strain than the TSF and TSF using Ilizarov components. In conclusion, both hexapod designs were less rigid axially, but more so under bending and torsional loads, than their Ilizarov construct counterparts, producing greater overall planar shear strain, largely due to the observed “toe-in” laxity. Overall, the TL-Hex was seen to be more rigid that the TSF under bending loads although the difference in shear strain at the fracture site was not significantly different


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 42 - 42
1 May 2018
Mazoochy H Vris A Brien J Heidari N
Full Access

Introduction. Segmental bone defect is a challenging problem. We report our experience of bone transport by hexapod external fixator in patients with segmental defects if the tibia. Method. We report herein 15 patients with segmental bone defect of tibia who completed their treatment protocol. All patients were treated had bone transport with Taylor Spatial Frame from 2012 to 2017. All were treated by the senior author NH. Parameters measured included age, sex, diabetes, smoking, diagnosis, method of fixation prior to treatment use of a free flap, bone defect size, frame-time, external fixation index. Results. Mean age at the time of frame application was 42.7 years. Mean follow-up after frame removal was 23.7 months. Three were diabetic, one smoked and one quit smoking during treatment. Seven had Gustilo-Anderson 3B (47%) and 5 Gustilo-Anderson 3A (33%) open fractures. Three (20%) had closed fractures. Nine (60%) had internal fixation with plate in eight and IM nail in one. Ten patients (67%) had soft tissue defect that required a free flap in seven, local flap in two and skin graft in one. Mean transport was 62 mm. Mean external fixator time and latency were 350.1 and 12 days, respectively. Mean External fixator, distraction and maturation indices were 2.1, 0.52 and 1.43 month per centimeter, respectively. Ten Extra- procedures were required in 7 patients. There were no docking site procedures, non-union of regenerate, adjunctive stabilization after frame removal, recurrence of bone infection and recurrence of deformity. Conclusions. Segmental resection and transport by TSF is an effective method to achieve length, alignment and eradicate infection. Although our cohort had longer external fixator indices than similar studies, the complication rate was low