Advertisement for orthosearch.org.uk
Results 1 - 20 of 146
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 20 - 20
17 Jun 2024
Jagani N Harrison W Davenport J Karski M Ring J Smith R Clough T
Full Access

Aims. Retrospective review of a consecutive series of 1,168 total ankle replacements (TAR) performed at Wrightington, to analyse modes of failure and clinical outcomes following TAR failure. Methods. All patients undergoing TAR between November 1993 – June 2019 were collated (4–25 year follow-up; mean 13.7 years). 6 implants were used (300 STAR, 100 Buechal Pappas, 509 Mobility, 118 Zenith, 41 Salto and 100 Infinity). 5 surgeons, all trained in TAR, performed the surgery. Modes of failure were collated and clinical and radiological outcomes recorded for the revisional surgery following failure of the TAR. Results. 156 (13.4%) TARs failed (47STAR 15.6%, 16BP 16%, 77Mobility 15.1%, 6Salto 14.6%, 10Zenith 8.5% and 0Infinity 0%). Mean time to failure 5.8 years (0.1- 21.4 years). The 4 most common modes of failure were 44.9% aseptic loosening, 11.5% gutter pain, 10.9% infection and 10.3% recurrent edge loading. 50 underwent conversion to tibiotalocalcaneal (TTC) fusion with nail with 9 (18%) failing to fuse. 31 underwent revision TAR with 2 (6.5%) subsequently failed. 22 underwent ankle fusion with 10 (45%) failing to fuse. 21 underwent polyethylene exchange of which 8 (38%) had further poly failure. 20 (12.8%) were managed conservatively, 2 (1.3%) required below knee amputation and 6 were listed but lost to follow-up. 81 of the 1168 (7%) consecutive cohort were lost to follow-up. Conclusions. 13.4% of the TAR cohort have failed at average follow-up 13.7 years. There was no difference in failure modes across the implant designs. Whilst the fixed bearing has the shortest follow-up, it may be performing better as there have been no failures so far. Prior to October 2016, most revisions were to fusion (TTC 18% failure rate, ankle 45% failure rate), whereas post 2016, 57% patients elected for revision TAR (6.5% failure)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 22 - 22
17 Jun 2024
Trew C Chambers S Siddique M Qasim S
Full Access

One assumed function of Total Ankle Replacement (TAR) is that by maintaining ankle joint motion we can protect the other hind foot joints from further degredation. 1. However, there is no work to our knowledge that compares hindfoot outcomes between TAR and arthrodesis. Sokolowski et al. found that 68% of TAR patients had no radiological progression of subtalar arthritis after TAR, and 4% went on to fusion. 2. However, no evaluation of the other hindfoot joints was made and no comparison made to other treatment. We performed a retrospective review of all patients at our centre who had had a TAR or ankle arthrodesis since 2002. Case notes and imaging were reviewed and all instances of hindfoot treatment (injections or surgical procedures) noted. Patients were excluded who had no documentation, were followed up at other hospitals, had prior hindfoot fusion, or were having staged surgeries at the time of index treatment. Chi squared analysis was used to compare the cohorts. 214 arthrodesis cases and 302 TAR were eligible. The average age was 57. Average time to follow up was 13 years (4–21). At the time of abstract submission 107 sets of notes had been reviewed fully. Full analysis will be performed by conference. 14% of TAR patients went on to have further procedures to the hindfoot joints while 35% of arthrodesis patients had further procedures (p=0.014). There was also a significant difference in the number of patients progressing to fusion of a further hindfoot joint between groups (TAR- 4%, arthrodesis- 20%, p=0.01). These data suggest that TAR are protective of symptomatic change of hindfoot joints. Patients with TAR had fewer hindfoot fusions than those with arthrodesis and also fewer procedures of any form, including injections


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 19 - 19
10 Jun 2024
Moriarity A Raglan M Dhar S
Full Access

Background. Patients who undergo either primary or revision total ankle replacement (TAR) expect improvements in pain, function and quality of life. The goal of this study was to measure the functional outcome improvements and the difference in patient-reported outcomes in patients undergoing primary total ankle replacements compared to revision TAR. Methods. A single-center prospective cohort study was undertaken between 2016 and 2022. All patients were followed up for a minimum of 6 months. Patients undertook the Manchester Oxford Foot Questionnaire (MoxFQ) and EQ-5D health quality questionnaires pre-operatively, at 6 months and yearly for life. The Mann Whitney test was undertaken for statistical analysis. Results. A total of 165 primary and 71 revision ankle replacements were performed between 2016 and 2022. The mean age was 71 years for primary replacements and 69 years for revisions. The INFINITY was utilized in the majority of primary total ankle replacements. Revision replacements were either the INBONE II or INVISION and they were most often revising the MOBILITY implant. The main indication for revision was aseptic loosening (83%). Other causes included infection, malalignment and insert wear. The overall MoxFQ improved by a mean of 46.5 for primaries and 40.2 for revisions. The EQ-5D score also showed overall improvements with the mean difference in mobility increasing by 1.6. Conclusion. Both primary and revision ankle replacements result in improved functional scores at 6 months, 1 year and 2 years. In this cohort with the implants used, both primary and revision ankle replacements demonstrate similar improvements in functional scores


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 17 - 17
10 Jun 2024
Porter A Nicolas AP Hakeem S Abdul N Elamin D Douglas-Harris M Ramaskandhan J Siddique M
Full Access

Background. Total Ankle Replacement (TAR) is an established treatment option for end-stage ankle arthritis. We analysed at minimum, 10-year patient-reported and clinical outcomes of 156 TARs from a single centre. We specifically compared outcomes between patients under 60 and over 60 at time of surgery. Methods. Data was collected retrospectively from our departmental patient database. It included all patients who underwent a TAR by a single surgeon between 2006 and 2010 and patients were divided into those under 60 and those over 60 at the time of surgery. Patient reported outcomes (PROMs), including WOMAC, SF-36 and patient satisfaction scores and complications were analysed preoperatively and at one, two, five and over 10 years postoperatively. Results. There were 156 patients included in this analysis, 61 were under 60 (mean age 50.29) and 95 were over 60 (mean age 69.12). A total of 12 patients had revision surgery, (nine in the under 60 group) and 52 patients were deceased at the time of analysis (10 in the under 60 group). At one year the over 60 group had less pain and better functional scores (p=0.02, p=0.017). At two, five and ten years there was no statistical difference in pain and function between groups. At two years the over 60s reported less stiffness and quicker return to activities of daily living (p=0.007, p=0.001). However, at five and 10 years there was no statistical difference in any domain. Conclusions. This study demonstrates that age does not correlate with a significant difference in pain or functional outcomes in patients who have TAR, at over 10 years follow up. The higher revision rates in the younger group may correlate with higher functional demand and lower mortality rate


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 18 - 18
10 Jun 2024
Haston S Langton D Townshend D Bhalekar R Joyce T
Full Access

Despite advancements, revision rates following total ankle replacement (TAR) are high in comparison to other total joint replacements. This explant analysis study aimed to investigate whether there was appreciable metal particulate debris release from various contemporary TARs by describing patterns of material loss. Twenty-eight explanted TARs (9 designs: 3 fixed and 6 mobile bearing), revised for any reason, were studied. The articulating surfaces of the metal tibial and talar components as well as the polyethylene insert were assessed for damage features using light microscopy. Based on the results of the microscopic analysis, scanning electron microscopy with energy dispersive X-ray spectroscopy was performed to determine the composition of embedded debris identified, as well as non-contacting 3D profilometry. Pitting, indicative of material loss, was identified on the articulating surfaces of 54% of tibial components and 96% of talar components. Bearing constraint was not found to be a factor, with similar proportions of fixed and mobile bearing metal components showing pitting. More cobalt-chromium than titanium alloy tibial components exhibited pitting (63% versus 20%). Significantly higher average surface roughness (Sa) values were measured for pitted areas in comparison to unpitted areas of these metal components (p<0.05). Additionally, metallic embedded debris (cobalt-chromium likely due to pitting of the tibial and talar components or titanium likely from loss of their porous coatings) was identified in 18% of polyethylene inserts. The presence of hard 3. rd. body particles was also indicated by macroscopically visible sliding plane scratching, identified on 79% of talar components. This explant analysis study demonstrates that metal debris is released from the articulating surfaces and the coatings of various contemporary TARs, both fixed and mobile bearing. These findings suggest that metal debris release in TARs may be an under-recognised issue that should be considered in the study of painful or failed TAR moving forwards


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 20 - 20
10 Jun 2024
Somanathan A Sharp B Saedi F Loizou C Brown R Kendal A
Full Access

Introduction. Primary ankle arthroplasty (TAR) is increasingly used to treat end-stage ankle arthritis. Reported revision rates of TAR vary from 8.5% to 11.1% at 9 years. Revision surgery remains technically challenging with options ranging from simple joint debridement to tibio-talar-calcaneal fusion. The efficacy of these procedures remains unclear and there is no consensus on optimal revision options. Methods. A retrospective cohort study was performed of all patients undergoing surgery for a failed primary TAR at the Nuffield Orthopaedic Centre (2004–2021). TAR failure was determined by clinical assessment, serial radiographs and CT scans. Primary outcome measures included type and time of index surgery post TAR. Secondary outcomes included frequency of re-operations, post-operative complications, patient reported outcomes and union rate (for revision arthrodesis procedures). Results. 70 failed TARs in 69 patients (35M:34F, mean 65.7 years, s.d.=11.6) underwent re-operation a mean of 6.24 years (range 1–30) post primary. In total, 107 operations were performed including revision fusion (n=50), revision arthroplasty (n=14), bearing exchange (n=9) and joint clearance (n=9). The overall revision fusion union rate was 73.5% over a mean of 12.5 months (s.d.=7.6). 16/23 (69.6%) Tibio-Talo-Calcaneal and 9/12 (75%) ankle fusions (previous subtalar/triple fusion) using a hindfoot nail united over a mean 11.4 months (s.d.=6.0) and 15 months (s.d.=9.48) respectively. Only 64% of ankle fusions using screws alone united (mean=10.6 months, s.d.=8.14). The average post-operative MOXFQ score was 28.3 (s.d.=19.3). 73% said the operation improved their function and would recommend it to a friend/family member. Conclusion. Despite low post-operative MOXFQ scores, over 70% of patients were satisfied with re-operation for a failed TAR. Over 26% of all TAR revision fusions fail to unite with the highest non-union rates observed post ankle arthrodesis with screws alone (36.4%)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 8 - 8
4 Jun 2024
Safdar NZ Chapman G Hopwood J Brockett C Redmond A
Full Access

Ankle fusion (AF), a durable intervention for ankle arthritis, has been the management of choice but restricts mobility. Recently, total ankle replacement (TAR) has been offered to patients looking to maintain mobility. The aim was to compare the biomechanics of AF and TAR while walking on inverted and everted slopes which create a greater demand for complex foot mobility than level walking. A ten-camera motion detection setup captured trials as patients walked in both directions over a 5⁰ lateral slope with embedded force plates. Moments (Nm/Kg) across the knee and ankle were exported from Visual 3D in the sagittal and frontal plane, and data were reported as means with 95% confidence intervals. 15 patients were recruited (6 TAR, 9 AF). The median age, follow-up and BMI was 67 years, 4 years and 35.8 kg/m² in AF, and 73 years, 7 years and 28.1 kg/m² in TAR, respectively. During inverted slope walking (4 TAR, 7 AF), abduction moments across (i) the knee: TAR 0.38 (0.37–0.39) vs AF 0.37 (0.27–0.52) and (ii) the ankle: TAR 0.20 (0.13–0.27) vs AF 0.25 (0.18–0.32), and extension moments across (i) the knee: TAR 0.68 (0.38–0.97) vs AF 0.85 (0.69–1.01) and (ii) the ankle: TAR 1.46 (1.30–1.62) vs AF 1.30 (1.08–1.52). During everted walking (5 TAR, 7 AF), abduction moments across (i) the knee: TAR 0.41 (0.30–0.52) vs AF 0.46 (0.27–0.66) and (ii) the ankle: TAR 0.24 (0.11–0.38) vs AF 0.26 (0.18–0.33), and extension moments across (i) the knee: TAR 0.76 (0.54–0.99) vs AF 0.93 (0.72–1.14) and (ii) the ankle: TAR 1.39 (1.19–1.59) vs AF 1.26 (1.04–1.48). There were no differences in abduction moments during inverted or everted slope walking. However, patients with AF had increased extension moments across the knee, particularly on inverted slopes, suggesting that AF creates a greater demand for knee compensation than TAR


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 19 - 19
16 May 2024
Clifton L Kingman A Rushton P Murty A Kakwani R Coorsh J Townshend D
Full Access

Introduction. We report the functional outcome and survivorship of the Hintegra Total Ankle Replacement (TAR), in consecutive cases by multiple surgeons in a single UK institution. Between 2010–2014 the Hintegra TAR held 7.1% UK market share and surgeons should be aware of failure mechanisms. Methods. We conducted a retrospective review of prospectively collected data for 70 consecutive Hintegra TAR cases in a single institution between 2010–2014. Data collected included patient demographics, complications, reoperations, patient reported outcome measures (PROMS: AOS, MOX-FQ, pain VAS) and patient satisfaction. Results. The 70 patients (54 male/ 16 female) had an average age of 69 (range 48–84 years). Mean follow up was 76 months (range 60–04), 10 patients died during the follow up. Implant survivorship was 81.4% at most recent follow up. The commonest radiographic finding was periprosthetic cysts (n=28, 40%), size range (7–40mm), location of cysts: isolated talus (n=14), isolated tibia (n=6), mixed (n=8). 10 failed TARs were revised to Inbone TAR at a mean of 48 months (range 9–69). 3 Failed TARs were revised to arthrodesis (2 tibiotalar fusions, 1 hindfoot nail). 11 patients required reoperation with implant retention: 8 periprosthetic cyst debridement and grafting at a mean of 61 months (range 27–91), 1 lateral gutter debridement and 1 periprosthetic fracture ORIF. PROMS data was available for all patients. Overall patients showed marked improvement in functional outcome scores between pre-operative and final follow up questionnaires. Mean pre-op AOS: 62, MOX-FQ: 68 and pain VAS: 67.5 with mean final follow up scores of: AOS: 35, MOX-FQ: 36 and pain VAS: 30. Conclusion. Our experience demonstrates improved PROMS following ankle arthroplasty for patients with a mean follow up of 6.4 years. Implant survivorship is similar to other TAR studies. We have identified a high incidence of periprosthetic cysts and would recommend ongoing surveillance of these patients


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 22 - 22
16 May 2024
Drake B Blundell M Gibson B Kingman A Kakwani R Townshend D
Full Access

Introduction. Day Case Surgery (defined as same day discharge) is a priority within the National Health Service and has been shown to provide beneficial outcomes for patients and hospitals. We report our experience developing a Day Case Programme for Total Ankle Replacement (TAR). Methods. Prior to the introduction of a Day Case Programme, average length of stay following TAR in our unit was 3.5 days. Stakeholders were consulted about ways in which same day discharge could be facilitated. Patients' post-operative pain charts were reviewed prior to the introduction of this programme. Inclusion criteria included non-complex surgery (anticipated tourniquet < 2hrs), friend or relative support and pre-operative walking-aid assessment. An enhanced recovery protocol included long-acting popliteal block and dexamethasone. Patients were discharged with opiate analgesia and written pain instructions. Patients were asked to complete a pain and satisfaction questionnaire. Patient Reported Outcome Measures (PROMs) were recorded. Results. From September 2017 to April 2019 21 of 70 patients underwent TAR as a Day Case. Mean age was 67 years (43-85 years). Complications included two delayed wound healings and one representation on day three with urinary retention. No patients reported post-operative nausea or vomiting, 60% did not use Oramorph at home. Average Visual Analogue Score for pain was 23/100 on day one and 21/100 day three post-operatively. There was no significant difference in pre-operative or overall change in MOXFQ, VAS or EQ5D PROMS. Conclusions. Early results suggest that Day Case Total Ankle Replacements are safe. Appropriate patient selection is necessary. Day Case Surgery relies on support and communication between multiple teams to organise and run effectively


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 16 - 16
16 May 2024
Ha T Higgs Z Watling C Osam C Madeley N Kumar C
Full Access

Introduction. Total ankle replacement (TAR) is performed for post-traumatic arthritis, inflammatory arthropathy, osteoarthritis and other indications. The Scottish Arthroplasty Project (SAP) began collection of data on TAR in 1997. In this study, using data from the SAP, we look at trends in the use and outcomes of TAR in Scotland. Methods. We identified 499 patients from the SAP who underwent TAR between 1997 and 2015 with imaging available on the National Picture Archiving and Communication System (PACS). We identified, and looked at trends in, implant type over the following time periods: 1998–2005; 2006–2010 and 2011–2015. Age, gender, indication and outcomes for each time period were examined and also trends with implant type over time. Results. There were 499 primary TAR procedures with an overall incidence of 0.5/10. 5. population per year. Eight different implants were identified with significant changes in the numbers of each type used over time. The peak incidence of TAR was in the 6th decade. The mean age of patients undergoing TAR from 59 years in 1997–2005, to 65 years in 2011–15 (p< 0.0001). The percentage of patients with inflammatory arthropathy was 52% in 1997–2005, compared with 10% in 2011–2015. Subsequent arthrodesis and infection rates appeared to be higher during the first time period. The female to male ratio also changed over time. The incidence of TAR increased overall during the study period (r= 0.9, p=< 0.0001). This may be due to a broadening range of indications and patient selection criteria, in turn due to increased surgeon experience and the evolution of implant design. Conclusion. This study examines a large number of TARs from an established arthroplasty registry. The rate of TAR has increased significantly in Scotland from 1997 to 2015. Indication and patient age has changed over time and this could potentially impact outcomes after ankle replacement


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 18 - 18
16 May 2024
Najefi A Ghani Y Goldberg A
Full Access

Background. The importance of total ankle replacement (TAR) implant orientation in the axial plane is poorly understood with major variation in surgical technique of implants on the market. Our aims were to better understand the axial rotational profile of patients undergoing TAR. Methods. In 157 standardised CT Scans of end-stage ankle arthritis patients planning to undergo primary TAR surgery, we measured the relationship between the knee posterior condylar axis, the tibial tuberosity, the transmalleolar axis(TMA) and the tibiotalar angle. The foot position was measured in relation to the TMA with the foot plantigrade. The variation between medial gutter line and the line bisecting both gutters was assessed. Results. The mean external tibial torsion was 34.5±10.3°(11.8–62°). When plantigrade the mean foot position relative to the TMA was 21±10.6°(0.7–38.4°) internally rotated. As external tibial torsion increased, the foot position became more internally rotated relative to the TMA(pearson correlation 0.6;p< 0.0001). As the tibiotalar angle became more valgus, the foot became more externally rotated relative to the TMA(pearson correlation −0.4;p< 0.01). The mean difference between the medial gutter line and a line bisecting both gutters was 4.9±2.8°(1.7°-9.4°). More than 51% of patients had a difference greater than 5°. The mean angle between the medial gutter line and a line perpendicular to the TMA was 7.5°±2.6°(2.8°-13.7°). Conclusion. There is a large variation in rotational profile of patients undergoing TAR, particularly between the medial gutter line and the transmalleolar axis. Surgeon designers and implant manufacturers need to develop consistent methods to guide surgeons towards judging appropriate axial rotation of their implanton an individual basis. We recommend careful clinical assessment and CT scanspre-operatively to enable the correct rotation to be determined


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 12 - 12
10 May 2024
Sevic A Patel C Tomlinson M
Full Access

Introduction. Comparative studies examining Fixed-Bearing (FB) and Mobile-Bearing (MB) Total Ankle Replacement (TAR) designs have demonstrated similar results and successful long-term outcomes for both. To date there has been no study directly comparing FB and MB designs of the same prosthesis. We present the first prospective randomised trial comparing patient satisfaction, functional outcomes and radiographic results of the Salto Talaris Fixed-Bearing and the Salto Mobile-Bearing Total Ankle Replacement in the treatment of end-stage ankle arthritis. Methods. A total of 108 adult patients with end-stage ankle arthritis were enrolled in the study between November 2014 and October 2021 with similar demographic comparison. Prospective patient-reported outcomes and standardised weightbearing ankle radiographs were performed preoperatively, at 6 weeks, 6 months and 12 months post-operatively, followed by yearly intervals. All surgeries were performed by a single non-design orthopaedic foot and ankle specialist with experience in over 200 Salto and Salto Talaris TAR prior to the study. Radiographs were examined independently by two clinicians. Complete patient data and radiographs were available for 103 patients with an average follow up of 2 years. Results. Both groups demonstrated statistically significant improvement from preoperative evaluation to most recent follow up with no statistically significant difference between the two groups in all outcome measures. Radiographic incidence of subchondral cyst formation was 8.9% and 38.2% for FB and MB, respectively. Talar subsidence occurred in 2.2% and 5.5% of FB and MB, respectively. Discussion. Our study demonstrates a higher than previously reported rate of cyst formation in the MB TAR and comparatively higher talar subsidence in the MB TAR vs FB however this did not correlate with clinical outcome measures which were favourable for both groups. Conclusion. Fixed-Bearing and Mobile-Bearing Total Ankle Replacement demonstrate comparable favourable


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 4 - 4
8 May 2024
Nurm T Ramaskandhan J Nicolas A Siddique M
Full Access

Introduction. Total ankle arthroplasty (TAA) is an increasingly popular treatment option for patients with end-stage ankle arthritis. However, for most implant systems, failure rates of 10–20% have been reported within the first 10 years after primary TAA. Pain is the primary symptom that indicates failure of TAA but cause of it can be difficult to establish. Methods. All patients who underwent a primary TAA at our center were included in the study. The clinical outcomes were studied for patients requiring a further revision procedure following primary TAA. The reasons for revision surgery and outcomes of surgery were analyzed using appropriate inferential statistical tests. Results. Between 2007 and 2018, 42 primary TAA required revisions in 40 patients. There were 25 men (59.5%) and 15 women (35.7%) with mean age of 57.5 years the time of primary TAA. All patients had undergone primary procedure at a mean duration of 3.5 years previously (range: 3 months to 10 years). Of the total revision procedures, 12/40 (30%) of revisions were carried out due to malalignment, 10/42 (23.8%) due to loosening of the implants or bone subsidence, 5/42 procedures (11.9%) following infection, 4/42 (9.5%) due to polyethylene migration, 1/42 (2.3%) due to fracture and 1/42 (2.3%) due to Charcot arthropathy. In 9/42 (21.4%) cases, imaging showed no objective reason for pain. 50% of patients who underwent revision TAA reported 78.5% satisfaction with results of surgery at 2 years follow up post-operatively. Conclusion. Major reasons for revising primary TAR at our centre are mal-alignment, implant loosening / bone subsidence and suspicion of infection and pain. In-spite of undergoing a complex revision surgery, patients report 78.5% satisfaction from outcomes of surgery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 24 - 24
8 May 2024
McKenna R Wong J Tucker A
Full Access

Muller-Weiss disease is an uncommon condition with unclear etiology and no gold standard treatment. The question arises; which joints to fuse? Although no consensuses prevail, one must postulate fusion should include those affected. Consequently, to establish an algorithm for its surgical management we set out to study clinical and radiographic features with use of SPECT-CT and a literature review. 57 consecutive feet presenting with Muller-Weiss disease analysed; 15 men, 25 women, age 22–84. Condition bilateral in 17, left side 16, right in 7 patients. Specific history and examination by senior author. Radiographic series and SPECT-CT obtained with surgery performed on significantly symptomatic feet. Measurements of Meary-Tomeno angles, anteroposterior thickness of navicular at the midpoint of each naviculo-cuneiform, alongside the medial extrusion distance and percentage of compression in each case performed. Poor correlation between Meary's angle and 1) degree of compression at naviculo-cuneiform joints, 2) degree of extrusion 3) compression vs extrusion using R. 2. coefficient of determination (invalidating Maceira et al. classification). In unilateral cases, extrusion significantly greater on affected side 94.7% (P< 0.001 Fisher exact test). Degree of extrusion significantly greater in bilateral than unilateral cases (p=0.004 unpaired T test). Valgus hindfoot and Meary's negative most common pattern with no correlation between heel alignment and Meary's R. 2. = 0.003. SPECT-CT useful to determine subtalar involvement in ‘stage 2 disease.’. Following review of cases and published literature we propose the following classification for Muller-Weiss disease with treatment algorithm. 3 Stage delineation; Stage 1 (Normal hindfoot alignment); 1A. Talonavicular disease only - Isolated Talonavicular arthrodesis 1B. Talonavicular + Subtalar; double medial or triple arthrodesis. Stage 2. Talonavicular + Naviculocuneiform; 2A. Adequate bone stock - Talo-naviculo-cuneiform arthrodesis, 2B. Inadequate bone stock +- subtalar disease; Talo-naviculo-cuneiform arthrodesis with tricortical bone graft (Mayich). Stage 3; Asymmetric ankle varus. Pantalar arthrodesis Double/triple/TNC/TAR arthrodesis with hindfoot re-alignment


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 5 - 5
8 May 2024
Nicolas AP Ramaskandhan J Nurm T Siddique M
Full Access

Introduction. Total ankle replacement as a valid treatment for end stage ankle arthritis, is gaining popularity and every year there is an increasing number of procedures. With revision rates as high as 21% at 5 years and 43% at 10 years there is a need for understanding and reporting the outcome of revision ankle replacement. Our aim was to study the patient reported outcomes following revision TAR with a minimum of 2 year follow up. Methods. All patients that underwent a revision total ankle replacement between 2012 and 2016 were included in the study. All patients received a post-operative questionnaire comprising of MOX-FQ score, EQ-5D (UK) and Foot and Ankle outcomes scores (FAOS) and patients satisfaction questionnaire with a minimum of 2 years follow up. Results. 33 patients had a revision total ankle replacement between 2012 and 2016. 2 patients were deceased therefore 31 patients were included in the study. 4 patients declined participation for completing questionnaires. We received 15/27 (55.5%) completed questionnaires. The mean MOX-FQ average domain score for pain was (50.6 ± 26.9), walking/standing (62.4 ± 36.5) and social function was (43.7± 31.0). The mean FAOS scores were (52.5 ± 30.6; pain), (54.5 ± 29.2; symptoms), (62.1 ± 30.5; ADL) and (35.5 ± 28.2; for quality of life). The mean overall health score today for EQ-5D was 73.9/100. 50% of patients were satisfied with the pain relief and return to sports and recreation obtained following the operation, 57% were satisfied with the improved in daily activities. 78.5% were overall satisfied with the results from surgery. Conclusion. Revision total ankle replacement gives overall satisfactory results demonstrated from patients reported outcomes at a minimum of 2 years following surgery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 6 - 6
8 May 2024
Miller D Senthi S Winson I
Full Access

Background. Total ankle replacements (TARs) are becoming increasingly more common in the treatment of end stage ankle arthritis. As a consequence, more patients are presenting with the complex situation of the failing TAR. The aim of this study was to present our case series of isolated ankle fusions post failed TAR using a spinal cage construct and anterior plating technique. Methods. A retrospective review of prospectively collected data was performed for 6 patients that had isolated ankle fusions performed for failed TAR. These were performed by a single surgeon (IW) between March 2012 and October 2014. The procedure was performed using a Spinal Cage construct and grafting in the joint defect and anterior plating. Our primary outcome measure was clinical and radiographic union at 1 year. Union was defined as clinical union and no evidence of radiographic hardware loosening or persistent joint lucent line at 1 year. Results. The mean follow-up was 37.3 months (SD 13.2). Union was achieved in 5 of the 6 patients (83%). One patient had a non-union that required revision fusion incorporating the talonavicular joint that successfully went on to unite across both joints. Another patient had radiographic features of non-union but was clinically united and asymptomatic and one required revision surgery for a bulky symptomatic lateral malleolus with fused ankle joint. Conclusion. The failing TAR presents a complex clinical situation. After removal of the implant there is often a large defect which if compressed leads to a leg length discrepancy and if filled with augment can increase the risk of non-union. Multiple methods have been described for revision, with many advocating fusion of both the ankle joint and subtalar joint. We present our case series using a spinal cage and anterior plating that allows preservation of the subtalar joint and a high rate of union


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 7 - 7
8 May 2024
Cunningham I Kumar C
Full Access

Aim. Surgical options for management of a failed ankle arthroplasty are currently limited; typically conversion to fusion is recommended with only a few patients being considered for revision replacement surgery. This paper presents our experience of revision ankle replacements in a cohort of patients with failed primary replacements. Method. A total of 18 revision TAR in 17 patients were performed in patients with aseptic loosening. The technique was performed by a single surgeon (CSK) over a 4 year period between July 2014 and August 2018 using the Inbone total ankle replacement system. Patient demographics and clinical outcomes were collected retrospectively using - MOXFQ, EQ5D, VAS pain score and patient satisfaction questionnaires. Results. 12 right and 6 left ankle replacements were revised in 17 patients (11 male/ 6 female). The mean age at revision was 69.1 years (range 56–81 years) with a mean BMI of 31. The mean surgical time was 171 minutes with 22% of cases requiring bone grafting. 6 patients had early wound complications, all superficial and settled with dressings. There were no deep infections, 2 patients had further surgery for exploration for possible nerve injuries. At a mean follow up of 20.6 months, 4 patients had mild/moderate ongoing pain with the majority of patients being satisfied with the outcome of their surgery. Conclusion. This study represents one of the largest group of patients reported to have undergone revision total ankle arthroplasty. Our experience shows that this results in acceptable level of complications and provides satisfactory function in most patients. We feel revision TAR is a viable option in patients with failed primary arthroplasty who wish to continue to maintain mobility at the ankle joint


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 69 - 69
2 Jan 2024
Kvarda P Siegler L Burssens A Susdorf R Ruiz R Hintermann B
Full Access

Varus ankle osteoarthritis (OA) is typically associated with peritalar instability, which may result in altered subtalar joint position. This study aimed to determine the extent to which total ankle replacement (TAR) in varus ankle OA can restore the subtalar position alignment using 3-dimensional semi-automated measurements on WBCT. Fourteen patients (15 ankles, mean age 61) who underwent TAR for varus ankle OA were retrospectively analyzed using semi- automated measurements of the hindfoot based on pre-and postoperative weightbearing WBCT (WBCT) imaging. Eight 3-dimensional angular measurements were obtained to quantify the ankle and subtalar joint alignment. Twenty healthy individuals were served as a control groups and were used for reliability assessments. All ankle and hindfoot angles improved between preoperative and a minimum of 1 year (mean 2.1 years) postoperative and were statistically significant in 6 out of 8 angles (P<0.05). Values The post-op angles were in a similar range to as those of healthy controls were achieved in all measurements and did not demonstrated statistical difference (P>0.05). Our findings indicate that talus repositioning after TAR within the ankle mortise improves restores the subtalar position joint alignment within normal values. These data inform foot and ankle surgeons on the amount of correction at the level of the subtalar joint that can be expected after TAR. This may contribute to improved biomechanics of the hindfoot complex. However, future studies are required to implement these findings in surgical algorithms for TAR in prescence of hindfoot deformity


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1099 - 1107
1 Oct 2023
Henry JK Shaffrey I Wishman M Palma Munita J Zhu J Cody E Ellis S Deland J Demetracopoulos C

Aims

The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant.

Methods

This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 131 - 131
11 Apr 2023
van Hoogstraten S Arts J
Full Access

An increasingly used treatment for end-stage ankle osteoarthritis is total ankle replacement (TAR). However, implant loosening and subsidence are commonly reported complications, leading to relatively high TAR failure rates. Malalignment of the TAR has often been postulated as the main reason for the high incidence of these complications. It remains unclear to what extent malalignment of the TAR affects the stresses at the bone-implant interface. Therefore, this study aims to elucidate the effect of TAR malalignment on the contact stresses on the bone-implant interface, thereby gaining more understanding of the potential role of malalignment in TAR failure. FE models of the neutrally aligned as well as malaligned CCI Evolution TAR implant (Van Straten Medical) were developed. Separate models were developed for the tibial and talar segment, with the TAR components in neutral alignment and 5° and 10° varus, valgus, anterior and posterior malalignment, resulting in a total of 9 differently aligned TAR models. Loading conditions of the terminal stance phase of the gait cycle, when the force on the ankle joint is highest (5.2x body weight), were applied. Peak and mean contact pressure and shear stress at the bone-implant interface were analyzed. Also, stress distributions on the bone-implant interface were visualized. In the neutrally aligned tibial and talar TAR models, peak contact pressures of respectively 98.4 MPa and 68.2 MPa, and shear stresses of respectively 49.3 MPa and 39.0 MPa were found. TAR malalignment increases peak contact pressure and shear stress on the bone-implant interface. A maximum peak contact pressure of 177 MPa was found for the 10° valgus malaligned tibial component and the highest shear stress found was 98.5 MPa for the 10° posterior malaligned talar model. Upon TAR malalignment contact stresses increase substantially, suggesting that proper orientation of the TAR is needed to minimize peak stresses on the bone-implant interface. This is in line with previous studies, which state that malalignment considerably increases bone strains, micromotion, and internal TAR contact pressures, which might increase the risk of TAR failure. Further research is needed to investigate the relationship between increased contact stresses at the bone-implant interface and TAR failure