Advertisement for orthosearch.org.uk
Results 1 - 20 of 27
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 81 - 81
14 Nov 2024
Ahmed NA Narendran K Ahmed NA
Full Access

Introduction. Anterior shoulder instability results in labral and osseous glenoid injuries. With a large osseous defect, there is a risk of recurrent dislocation of the joint, and therefore the patient must undergo surgical correction. An MRI evaluation of the patient helps to assess the soft tissue injury. Currently, the volumetric three-dimensional (3D) reconstructed CT image is the standard for measuring glenoid bone loss and the glenoid index. However, it has the disadvantage of exposing the patient to radiation and additional expenses. This study aims to compare the values of the glenoid index using MRI and CT. Method. The present study was a two-year cross-sectional study of patients with shoulder pain, trauma, and dislocation in a tertiary hospital in Karnataka. The sagittal proton density (PD) section of the glenoid and enface 3D reconstructed images of the scapula were used to calculate glenoid bone loss and the glenoid index. The baseline data were analyzed using descriptive statistics, and the Chi-square test was used to test the association of various complications with selected variables of interest. Result. The glenoid index calculated in the current study using 3D volumetric CT images and MR sagittal PD images was 0.95±0.01 and 0.95±0.01, respectively. The CT and MRI glenoid bone loss was 5.41±0.65% and 5.38±0.65%, respectively. When compared, the glenoid index and bone loss calculated by MRI and CT revealed a high correlation and significance with a p-value of <0.001. Conclusions. The study concluded that MRI is a reliable method for glenoid measurement. The sagittal PD sequence combined with an enface glenoid makes it possible to identify osseous defects linked to glenohumeral joint damage and dislocation. The values derived from 3D CT are identical to the glenoid index and bone loss determined using the sagittal PD sequence in MRI


Bone & Joint Open
Vol. 5, Issue 7 | Pages 534 - 542
1 Jul 2024
Woods A Howard A Peckham N Rombach I Saleh A Achten J Appelbe D Thamattore P Gwilym SE

Aims

The primary aim of this study was to assess the feasibility of recruiting and retaining patients to a patient-blinded randomized controlled trial comparing corticosteroid injection (CSI) to autologous protein solution (APS) injection for the treatment of subacromial shoulder pain in a community care setting. The study focused on recruitment rates and retention of participants throughout, and collected data on the interventions’ safety and efficacy.

Methods

Participants were recruited from two community musculoskeletal treatment centres in the UK. Patients were eligible if aged 18 years or older, and had a clinical diagnosis of subacromial impingement syndrome which the treating clinician thought was suitable for treatment with a subacromial injection. Consenting patients were randomly allocated 1:1 to a patient-blinded subacromial injection of CSI (standard care) or APS. The primary outcome measures of this study relate to rates of recruitment, retention, and compliance with intervention and follow-up to determine feasibility. Secondary outcome measures relate to the safety and efficacy of the interventions.


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims

This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults.

Methods

This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 552 - 561
28 Jul 2021
Werthel J Boux de Casson F Burdin V Athwal GS Favard L Chaoui J Walch G

Aims

The aim of this study was to describe a quantitative 3D CT method to measure rotator cuff muscle volume, atrophy, and balance in healthy controls and in three pathological shoulder cohorts.

Methods

In all, 102 CT scans were included in the analysis: 46 healthy, 21 cuff tear arthropathy (CTA), 18 irreparable rotator cuff tear (IRCT), and 17 primary osteoarthritis (OA). The four rotator cuff muscles were manually segmented and their volume, including intramuscular fat, was calculated. The normalized volume (NV) of each muscle was calculated by dividing muscle volume to the patient’s scapular bone volume. Muscle volume and percentage of muscle atrophy were compared between muscles and between cohorts.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1176 - 1182
14 Sep 2020
Mathews JA Kalson NS Tarrant PM Toms AD

Aims

The James Lind Alliance aims to bring patients, carers, and clinicians together to identify uncertainties regarding care. A Priority Setting Partnership was established by the British Association for Surgery of the Knee in conjunction with the James Lind Alliance to identify research priorities related to the assessment, management, and rehabilitation of patients with persistent symptoms after knee arthroplasty.

Methods

The project was conducted using the James Lind Alliance protocol. A steering group was convened including patients, surgeons, anaesthetists, nurses, physiotherapists, and researchers. Partner organizations were recruited. A survey was conducted on a national scale through which patients, carers, and healthcare professionals submitted key unanswered questions relating to problematic knee arthroplasties. These were analyzed, aggregated, and synthesized into summary questions and the relevant evidence was checked. After confirming that these were not answered in the current literature, 32 questions were taken forward to an interim prioritization survey. Data from this survey informed a shortlist taken to a final consensus meeting.


Bone & Joint 360
Vol. 8, Issue 5 | Pages 33 - 35
1 Oct 2019


Bone & Joint 360
Vol. 7, Issue 4 | Pages 22 - 25
1 Aug 2018


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 693 - 702
1 Jun 2018
Jayakumar P Overbeek CL Vranceanu A Williams M Lamb S Ring D Gwilym S

Aims

Outcome measures quantifying aspects of health in a precise, efficient, and user-friendly manner are in demand. Computer adaptive tests (CATs) may overcome the limitations of established fixed scales and be more adept at measuring outcomes in trauma. The primary objective of this review was to gain a comprehensive understanding of the psychometric properties of CATs compared with fixed-length scales in the assessment of outcome in patients who have suffered trauma of the upper limb. Study designs, outcome measures and methodological quality are defined, along with trends in investigation.

Materials and Methods

A search of multiple electronic databases was undertaken on 1 January 2017 with terms related to “CATs”, “orthopaedics”, “trauma”, and “anatomical regions”. Studies involving adults suffering trauma to the upper limb, and undergoing any intervention, were eligible. Those involving the measurement of outcome with any CATs were included. Identification, screening, and eligibility were undertaken, followed by the extraction of data and quality assessment using the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) criteria. The review is reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria and reg

istered (PROSPERO: CRD42016053886).


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 503 - 507
1 Apr 2017
White TO Mackenzie SP Carter TH Jefferies JG Prescott OR Duckworth AD Keating JF

Aims

Fracture clinics are often characterised by the referral of large numbers of unselected patients with minor injuries not requiring investigation or intervention, long waiting times and recurrent unnecessary reviews. Our experience had been of an unsustainable system and we implemented a ‘Trauma Triage Clinic’ (TTC) in order to rationalise and regulate access to our fracture service. The British Orthopaedic Association’s guidelines have required a prospective evaluation of this change of practice, and we report our experience and results.

Patients and Methods

We review the management of all 12 069 patients referred to our service in the calendar year 2014, with a minimum of one year follow-up during the calendar year 2015.


Bone & Joint Research
Vol. 5, Issue 10 | Pages 481 - 489
1 Oct 2016
Handoll HHG Brealey SD Jefferson L Keding A Brooksbank AJ Johnstone AJ Candal-Couto JJ Rangan A

Objectives

Accurate characterisation of fractures is essential in fracture management trials. However, this is often hampered by poor inter-observer agreement. This article describes the practicalities of defining the fracture population, based on the Neer classification, within a pragmatic multicentre randomised controlled trial in which surgical treatment was compared with non-surgical treatment in adults with displaced fractures of the proximal humerus involving the surgical neck.

Methods

The trial manual illustrated the Neer classification of proximal humeral fractures. However, in addition to surgical neck displacement, surgeons assessing patient eligibility reported on whether either or both of the tuberosities were involved. Anonymised electronic versions of baseline radiographs were sought for all 250 trial participants. A protocol, data collection tool and training presentation were developed and tested in a pilot study. These were then used in a formal assessment and classification of the trial fractures by two independent senior orthopaedic shoulder trauma surgeons.


Bone & Joint 360
Vol. 5, Issue 2 | Pages 42 - 42
1 Apr 2016


Bone & Joint 360
Vol. 4, Issue 5 | Pages 28 - 30
1 Oct 2015

The October 2015 Research Roundup360 looks at: Wasted implants; Biofilms revisited; Peri-operative anticoagulation not required in atrial fibrillation; Determinants in outcome following orthopaedic surgery; Patient ‘activation’ and outcomes; Neuroplasticity and nerve repair; KOOS Score in predicting injury?


Bone & Joint 360
Vol. 4, Issue 4 | Pages 33 - 35
1 Aug 2015

The August 2015 Research Roundup360 looks at: Lightbulbs, bleeding and procedure durations; Infection and rheumatoid agents; Infection rates and ‘bundles of care’ revisited; ACI: new application for a proven technology?; Hydrogel coating given the thumbs up; Hydroxyapatite as a smart coating?


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 574 - 579
1 May 2014
Talbot CL Ring J Holt EM

We present a review of claims made to the NHS Litigation Authority (NHSLA) by patients with conditions affecting the shoulder and elbow, and identify areas of dissatisfaction and potential improvement. Between 1995 and 2012, the NHSLA recorded 811 claims related to the shoulder and elbow, 581 of which were settled. This comprised 364 shoulder (64%), and 217 elbow (36%) claims. A total of £18.2 million was paid out in settled claims. Overall diagnosis, mismanagement and intra-operative nerve injury were the most common reasons for litigation. The highest cost paid out resulted from claims dealing with incorrect, missed or delayed diagnosis, with just under £6 million paid out overall. Fractures and dislocations around the shoulder and elbow were common injuries in this category. All 11 claims following wrong-site surgery that were settled led to successful payouts.

This study highlights the diagnoses and procedures that need to be treated with particular vigilance. Having an awareness of the areas that lead to litigation in shoulder and elbow surgery will help to reduce inadvertent risks to patients and prevent dissatisfaction and possible litigation.

Cite this article: Bone Joint J 2014; 96-B:574–9.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 29 - 32
1 Feb 2014

The February 2014 Trauma Roundup360 looks at: predicting nonunion; compartment Syndrome; octogenarian RTCs; does HIV status affect decision making in open tibial fractures?; flap timing and related complications; proximal humeral fractures under the spotlight; restoration of hip architecture with bipolar hemiarthroplasty in the elderly; and short versus long cephalomedullary nails for the treatment of intertrochanteric hip fractures in patients over 65 years.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1114 - 1120
1 Aug 2013
Wijdicks CA Anavian J Hill BW Armitage BM Vang S Cole PA

The glenopolar angle assesses the rotational alignment of the glenoid and may provide prognostic information and aid the management of scapula fractures. We have analysed the effect of the anteroposterior (AP) shoulder radiograph rotational offset on the glenopolar angle in a laboratory setting and used this to assess the accuracy of shoulder imaging employed in routine clinical practice. Fluoroscopic imaging was performed on 25 non-paired scapulae tagged with 2 mm steel spheres to determine the orientation of true AP views. The glenopolar angle was measured on all the bony specimens rotated at 10° increments. The mean glenopolar angle measured on the bone specimens in rotations between 0° and 20° and thereafter was found to be significantly different (p < 0.001). We also obtained the AP radiographs of the uninjured shoulder of 30 patients treated for fractures at our centre and found that none fitted the criteria of a true AP shoulder radiograph. The mean angular offset from the true AP view was 38° (10° to 65°) for this cohort. Radiological AP shoulder views may not fully project the normal anatomy of the scapular body and the measured glenopolar angle. The absence of a true AP view may compromise the clinical management of a scapular fracture.

Cite this article: Bone Joint J 2013;95-B:1114–20.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 820 - 824
1 Jun 2013
Zsoldos CM Basamania CJ Bal GK

Gunshot injuries to the shoulder are rare and difficult to manage. We present a case series of seven patients who sustained a severe shoulder injury to the non-dominant side as a result of a self-inflicted gunshot wound. We describe the injury as ‘suicide shoulder’ caused by upward and outward movement of the gun barrel as the trigger is pulled. All patients were male, with a mean age of 32 years (21 to 48). All were treated at the time of injury with initial repeated debridement, and within four weeks either by hemiarthroplasty (four patients) or arthrodesis (three patients). The hemiarthroplasty failed in one patient after 20 years due to infection and an arthrodesis was attempted, which also failed due to infection. Overall follow-up was for a mean of 26 months (12 to 44). All four hemiarthroplasty implants were removed with no feasible reconstruction ultimately possible, resulting in a poor functional outcome and no return to work. In contrast, all three primary arthrodeses eventually united, with two patients requiring revision plating and grafting. These patients returned to work with a good functional outcome. We recommend arthrodesis rather than replacement as the treatment of choice for this challenging injury.

Cite this article: Bone Joint J 2013;95-B:820–4.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 78 - 78
1 Sep 2012
Mares O Mares O Luneau S Staquet V Beltrand E Bousquet PJ Maynou C
Full Access

Introduction. Acromioclavicular dislocation (ACD) is frequent, at 8% of all shoulder traumas. Management in grade III lesions remains controversial. The present study assessed objective and subjective results at medium-term follow-up (mean, 60 months; range, 12—120 mo) in 27 patients managed by Ligastic® ligament reconstruction for acute dislocation. Patients and Methods. This is a multicenter, multi-surgeon retrospective study. Between 1998 and 2006, 59 patients were operated on for grade III or IV ACD, in one teaching hospital (Lille, France) and one general hospital (Tourcoing, France). Follow-up was performed by an indepen- dent (non-operator) observer. The 27 acute cases followed up underwent comparative bilateral radioclinical shoulder examination. Initial X-ray assessment found 14 grade-III (52%) and 13 grade-IV (48%) dislocations using Patte's classification. Results. Mean Constant score was significantly lower on the operated side (82.44 vs 90.04; p < 0.05). Specific strength analysis, on the other hand, showed no significant difference with the contralateral shoulder. Coracoclavicular distance was significantly greater on the operated side (p < 0.05), with and without traction. Periprosthetic osteolysis was found in 24% of cases, and seemed to worsen over follow-up. There were no cases of fracture on osteolysis. There were no cases of sepsis or of implant intolerance. Four patients, however, required surgical revision. Conclusion. In light of literature findings and our own experience, surgery is not to be recom- mended in grade-III ACD, and the authors have given up use of this device in this group due to the rate of associated osteolysis. Level of evidence. Level IV


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 102 - 102
1 May 2011
Akhtar M Robinson C
Full Access

Purpose: This study was performed to assess the incidence of generalized ligament laxity in patients undergoing revision shoulder stabilization. Methods and Results: Prospective data was collected for 21 patients undergoing revision shoulder stabilization and 43 patients with clavicle fractures as a control group, between 2004 and 2009 under the care of orthopaedic surgeons at the Royal Infirmary of Edinburgh including demographic details, type of primary stabilization and causes of failure. Clinical examination was used to assess the ligament laxity using the Beighton score. Laxity is scored on a 0–9 scale. Scores of 4 or above are indicative of generalized ligament laxity. Brighton criteria is used to diagnose Benign Joint Hypermobility Syndrome (BJHS) and use signs and symptoms along with Beighton score. The most common primary procedure for shoulder instability was open stabilization in 15 patients (75%). The most common cause of failure was trauma in 14 patients (67%). The mean age was 29 years with a range from 22–58 years. There were 16 males and 5 females. The average Beighton score for patients undergoing revision shoulder stabilization was 2.8 with a range from 0–7. 13 patients (61%) in this group had a Beighton score of 4 or more as compared to 12 patients (27%) in the control group. This difference was statistically significant with a P value of 0.018. 11 patients (52%) fulfilled the Brighton criteria for BJHS. Conclusion: We found that there is a high incidence (61%) of generalized ligament laxity in patients undergoing revision shoulder stabilization. Trauma is a common (67%) cause of failure in these patients. Patients with generalized ligament laxity should be made aware about the high failure rate after shoulder stabilization at their primary surgery and appropriate advice about rehabilitation should be given


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 202 - 202
1 May 2011
Ciccarelli M Russo R Della Rotonda G Cautiero F
Full Access

Purpose: The three dimensional position of the tuberosity and the tension of the rotator cuff influence the structural changes of the rotator cuff and their influence on clinical results of reversed trauma prostheses.

We propose this technique with it of a biological support, the fractured humeral head, adequately modeled, in order to give again the just tension to the cuff

Method: from February 2007 and February 2009 we treated 29 patients with a reversed trauma prostehes, in 7 cases we have practiced the bony necktie, for giving a support to the correct reconstruction of the tuberosity. The patients have an average of 71,5 years and was evaluated with Constant score and radiographic study with mean follow-up of 18,6 months

Results: Improvement of postoperative Constant score and radiographic good results were correlated with satisfactory subjective results. However, these results will have to be confirmed with more cases and later revision

Conclusion: Tuberosity position and healing is critical for clinical and radiographic outcome in shoulder arthroplasty in trauma. In particular the rate resorption of the tuberosity in Reverse Trauma Prostheses still is elevated. we propose a new surgical technical in order to give again the just position to the tuberosity fractured and therefore to give tension to the rotator cuff