Advertisement for orthosearch.org.uk
Results 1 - 20 of 1093
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 942 - 948
1 Sep 2024
Kingery MT Kadiyala ML Walls R Ganta A Konda SR Egol KA

Aims

This study evaluated the effect of treating clinician speciality on management of zone 2 fifth metatarsal fractures.

Methods

This was a retrospective cohort study of patients with acute zone 2 fifth metatarsal fractures who presented to a single large, urban, academic medical centre between December 2012 and April 2022. Zone 2 was the region of the fifth metatarsal base bordered by the fourth and fifth metatarsal articulation on the oblique radiograph. The proportion of patients allowed to bear weight as tolerated immediately after injury was compared between patients treated by orthopaedic surgeons and podiatrists. The effects of unrestricted weightbearing and foot and/or ankle immobilization on clinical healing were assessed. A total of 487 patients with zone 2 fractures were included (mean age 53.5 years (SD 16.9), mean BMI 27.2 kg/m2 (SD 6.0)) with a mean follow-up duration of 2.57 years (SD 2.64).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 20 - 20
19 Aug 2024
Tikhilov RM Bilyk SS Dzhavadov AA Shubnyakov II
Full Access

Literature data show varying rates of aseptic loosening of standard hemispherical cups after primary total hip arthroplasty (THA) in patients with Crowe IV developmental dysplasia of the hip (DDH). In order to improve the results regarding the frequency of aseptic loosening of the acetabular component, we decided to use custom-made acetabular implants (CMAI) in this category of patients. The aim of our study was to report outcomes after primary THA using CMAI in patients with Crowe IV DDH. We retrospectively analyzed the results of primary THA using the CMAI in 58 hips. The mean follow-up period was 5.2 years (range 4.2 – 6.3). Patients demonstrated improved functional outcomes according to the Oxford Hip Score: preoperatively 16.9 and postoperatively 38.5 (P < 0.05). Revisions were performed in 2 cases due to dislocations, in 1 case due to nonunion of the greater trochanter and in 1 case due to chronic pain syndrome caused by contact of the CMAI flange with the iliopsoas muscle. In a patient with chronic pain syndrome, during the revision, the pubic flange of the CMAI, which was in contact with the iliopsoas muscle, was removed. There were no radiological signs of loosening of the CMAI. The use of CMAI shows good results in patients with DDH. Extended capability for supplementary screw fixation is an excellent feature of such implants, allowing them to obtain reliable primary fixation. Further observation is required to assess CMAI in the long-term follow-up


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 54 - 54
19 Aug 2024
AlFayyadh F Neufeld ME Howard LC Masri BA Greidanus NV Garbuz D
Full Access

There remains concern with the use of constrained liners (CL) implanted at the time of acetabular cup revision in revision total hip replacement (rTHA). The aim of this study was to determine the implant survival in rTHA when a CL was implanted at the same time as acetabular cup revision. We reviewed our institutional database to identify all consecutive rTHAs where a CL was implanted simultaneously at the time acetabular cup revision from 2001 to 2021. One-hundred and seventy-four revisions (173 patients) were included in the study. Mean follow-up of 8.7 years (range two – 21.7). The most common indications for rTHA were instability (35%), second-stage periprosthetic joint infection (26.4%), and aseptic loosening (17.2%). Kaplan Meier Analysis was used to determine survival with all-cause re-revision and revision for cup aseptic loosening (fixation failure) as the endpoints. A total of 32 (18.3%) patients underwent re-revision at a mean time of 2.9 years (range 0.1 – 14.1). The most common reasons for re-revision were instability (14), periprosthetic joint infection (seven), and loosening of the femoral component (four). Three (1.7%) required re-revision due to aseptic loosening of the acetabular component (fixation failure) at a mean of two years (0.1 – 5.1). Acetabular component survival free from re-revision due to aseptic loosening was 98.9% (95% CI 97.3 – 100) at five-years and 98.1% (95% CI 95.8 – 100) at 10-years. There were no acetabular component fixation failures in modern highly porous shells. CLs implanted at the time acetabular cup revision in rTHA have a 98.1% 10-year survival free from acetabular cup aseptic loosening (fixation failure). There were no cup fixation failures in modern highly porous shells. Thus, when necessary, implanting a CL during revision of an acetabular component with stable screw fixation is safe with an extremely low risk of cup fixation failure


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 84 - 84
19 Aug 2024
Cordero-Ampuero J
Full Access

Debate continues about the best treatment for patients over 65 years with non-displaced subcapital hip fractures: internal fixation (IF) or hemiarthroplasty (HA). Surgical aggression, mortality, complications and recovery of walking ability after 1year have been compared between both treatments.

Match-paired comparison of 2 retrospective cohorts. 220 patients with IF vs 220 receiving a cemented bipolar HA. Matching by age (82.6±7.16 years (65–99)), sex (74.5% women), year of intervention (2013–2021) and ASA scale (24.2% ASA II, 55.8% III, 20.0% IV).

Age (p=0.172), sex (p=0.912), year of intervention (p=0.638) and ASA scale (p=0.726) showed no differences.

Surgical aggression smaller in IF: Surgical time (p< 0,00001), haemoglobin/haematocrit loss (p <0,00001), need for transfusion (p<0,00008), in-hospital stay (p<0,00001).

Mortality: higher in-hospital for hemiarthroplasties (12 deaths (5.5%) vs 1 (0.5%) (p=0.004) (RR=12, 1.5–91.5)). But no significant differences in 1-month (13 hemiarthroplasties, 6%, vs 9 osteosynthesis, 4.1%) and 1-year mortality (33 hemiarthroplasties, 15%, vs 35, 16%).

Medical complications: no differences in urinary/respiratory infections, heart failure, ictus, myocardial infarction, digestive bleeding, pressure sores or pulmonary embolus (p=0.055).

Surgical complications: no significant differences. HA: 6 intraoperative (2,7%) and 5 postoperative periprosthetic fractures (2,3%), 5 infections (2,3%), 10 dislocations (4,5%), 3 neurovascular injuries. IF: 10 acute fixation failures (4,5%), 2 infections (0,9%), 9 non-unions (4,1%), 16 ischemic necrosis (7,3%).

Functional results: no significant differences; 12 patients in each group (5,5%) never walked again (p=1), 110 HA (50%) and 100 IF (45.5%) suffered worsening of previous walking ability (p=0.575), 98 HA (44%) and 108 IF patients (49%) returned to pre-fracture walking ability (p=0.339).

Fixation with cannulated screws may be a better option for non-displaced femoral neck fractures because recovery of walking ability and complications are similar, while surgical aggression and in-hospital mortality are lower.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 19 - 23
2 Aug 2024

The August 2024 Foot & Ankle Roundup360 looks at: ESWT versus surgery for fifth metatarsal stress fractures; Minimally invasive surgery versus open fusion for hallux rigidus; Diabetes and infection risk in total ankle arthroplasty; Is proximal medial gastrocnemius recession useful for managing chronic plantar fasciitis?; Fuse the great toe in the young!; Conservative surgery for diabetic foot osteomyelitis; Mental health and outcome following foot and ankle surgery.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 31 - 35
2 Aug 2024

The August 2024 Trauma Roundup360 looks at: Does topical vancomycin prevent fracture-related infections in closed fractures undergoing open reduction and internal fixation? A randomized controlled trial; Is postoperative splinting advantageous after upper limb fracture surgery?; Does suprapatellar nailing resolve knee pain?; Locking versus non-locking plate fixation in comminuted talar neck fractures: a biomechanical study using cadaveric specimens; Revolutionizing recovery metrics: PROMIS versus SMFA in orthopaedic trauma care; Dorsal hook plating of patella fractures: reliable fixation and satisfactory outcomes; The impact of obesity on subtrochanteric femur fracture outcomes; Low-dose NSAIDs (ketorolac) and cytokine modulation in orthopaedic polytrauma: a detailed analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 775 - 782
1 Aug 2024
Wagner M Schaller L Endstrasser F Vavron P Braito M Schmaranzer E Schmaranzer F Brunner A

Aims

Hip arthroscopy has gained prominence as a primary surgical intervention for symptomatic femoroacetabular impingement (FAI). This study aimed to identify radiological features, and their combinations, that predict the outcome of hip arthroscopy for FAI.

Methods

A prognostic cross-sectional cohort study was conducted involving patients from a single centre who underwent hip arthroscopy between January 2013 and April 2021. Radiological metrics measured on conventional radiographs and magnetic resonance arthrography were systematically assessed. The study analyzed the relationship between these metrics and complication rates, revision rates, and patient-reported outcomes.


Bone & Joint Open
Vol. 5, Issue 7 | Pages 570 - 580
10 Jul 2024
Poursalehian M Ghaderpanah R Bagheri N Mortazavi SMJ

Aims

To systematically review the predominant complication rates and changes to patient-reported outcome measures (PROMs) following osteochondral allograft (OCA) transplantation for shoulder instability.

Methods

This systematic review, following PRISMA guidelines and registered in PROSPERO, involved a comprehensive literature search using PubMed, Embase, Web of Science, and Scopus. Key search terms included “allograft”, “shoulder”, “humerus”, and “glenoid”. The review encompassed 37 studies with 456 patients, focusing on primary outcomes like failure rates and secondary outcomes such as PROMs and functional test results.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 489 - 498
12 Jun 2024
Kriechling P Bowley ALW Ross LA Moran M Scott CEH

Aims

The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs).

Methods

All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 8 - 8
10 Jun 2024
Airey G Aamir J Chapman J Tanaka H Elbannan M Singh A Mangwani J Kyaw H Jeyaseelan L Mason L
Full Access

Background. Research on midfoot injuries have primarily concentrated on the central column and the Lisfranc ligament without amassing evidence on lateral column injuries. Lateral column injuries have historically been treated with Kirschner wire fixation when encountered. Objective. Our aim in this study was to analyse lateral column injuries to the midfoot, their method of treatment and the radiological lateral column outcomes. Our nul hypothesis being that fixation is required to obtain and maintain lateral column alignment. Methods. Data was retrospectively collected from four centres on surgically treated midfoot fracture dislocations between 2011 and 2021. Radiographs were analysed using departmental PACS. All statistics was performed using SPSS 26. Results. A total of 235 cases were diagnosed as having a lateral column injury out of the 409 cases included. On cross tabulation, there was a significant association with having a central column injury (234/235, p<.001) and 70% of cases (166/235) also had an additional medial column injury. Of the 235 lateral column injuries, data was available regarding fixation radiographic alignment on 222 cases. There were 44 cases which underwent Kirschner wire fixation, 23 plate fixations and 3 screw fixations. Lateral column alignment loss was seen in 2.84% (4/141) of those which didn't undergo fixation, 13.64% (6/44) which underwent K wires, and 0 % in those fixed by screws or K wires. Conclusion. Lateral column injury occurs in over half of midfoot fractures in this study. It rarely occurs alone and is most commonly related to three column injuries. Nevertheless, following stabilisation of the central column, additional fixation of injuries to the lateral column do not appear beneficial. The use of a bridge plate to fix the central column appears protective and purely ligamentous injury was a higher risk than an injury that included the bone


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 6 - 6
10 Jun 2024
Bethel J Najefi A Davies M Gosney E Patel K Ahluwalia R
Full Access

Introduction. Hindfoot intramedullary nail fixation (HFN) or fibula pro-tibial screw fixation (PTS) are surgical options for ankle fractures in patients with multiple co-morbidities; we compared their outcomes. Methods. A retrospective review of 135 patients who underwent HFN fixation (87 patients) or PTS fixation (48 patients) for ankle fractures (AO/OTA A/B/C) from 5 major trauma centres. Patient demographic data, co-morbidities, Charlson Co-morbidity Index Score (CCIS), weight-bearing, and post-operative complications were recorded. Radiographs were assessed for non-union and anatomical reduction. Results. HFN estimated 10-year survival was 27±31% and was 48±37% for PTS (p<0.001). Average time to full weightbearing (FWB) in the HFN group was 1.7±3.3 weeks compared to 7.8±3.8 weeks in the PTS group (p<0.001). Despite this, HFN fixation carried a greater VTE risk (p=0.02). HFN accompanied by joint preparation had greater risk of infection (p=0.01), metalwork failure (p=0.02) and wound breakdown (p=0.01). The overall complication rate in diabetic patients was 56%, but 76% in HFN patients. In the HFN group 17 (20%) patients died at 1 year. Patients with open fractures(p=0.01), dementia (p<0.05), and a higher CCIS (p=0.04) were more likely to die after HFN surgery. Age and co-morbidity matched data showed a higher rate of complications and mortality in those above 75 years fixed with a HFN, irrespective of CCIS. In those between 60–75 years, there was a greater risk of superficial infection and mortality after HFN, irrespective of CCIS. These complications were not seen after PTS. Conclusion. HFN carries a greater risk of superficial infections, VTE and mortality compared to PTS, independent of age and CCIS. Diabetes leads to a greater comparative risk of deep infections, wound breakdown and non-union in HFN. Alternative methods of fixation (e.g. PTS) should be considered before HFN. HFN may be suitable in selective indications where other methods are not appropriate


Bone & Joint Open
Vol. 5, Issue 5 | Pages 385 - 393
13 May 2024
Jamshidi K Toloue Ghamari B Ammar W Mirzaei A

Aims

Ilium is the most common site of pelvic Ewing’s sarcoma (ES). Resection of the ilium and iliosacral joint causes pelvic disruption. However, the outcomes of resection and reconstruction are not well described. In this study, we report patients’ outcomes after resection of the ilium and iliosacral ES and reconstruction with a tibial strut allograft.

Methods

Medical files of 43 patients with ilium and iliosacral ES who underwent surgical resection and reconstruction with a tibial strut allograft between January 2010 and October 2021 were reviewed. The lesions were classified into four resection zones: I1, I2, I3, and I4, based on the extent of resection. Functional outcomes, oncological outcomes, and surgical complications for each resection zone were of interest. Functional outcomes were assessed using a Musculoskeletal Tumor Society (MSTS) score and Toronto Extremity Salvage Score (TESS).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 12 - 12
2 May 2024
Selim A Al-Hadithy N Diab N Ahmed A Kader KA Hegazy M Abdelazeem H Barakat A
Full Access

Lag screw cut-out is a serious complication of dynamic hip screw fixation in trochanteric hip fractures. Lag screw position is recognised as a crucial factor influencing the occurrence of lag screw cut-out. We propose a modification of the Tip Apex Distance (TAD) and hypothesize that it could enhance the reliability of predicting lag screw cut-out in these injuries. A retrospective study of hip fracture cases was conducted from January 2018 to July 2022. A total of 109 patients were eligible for the final analysis. The modified TAD was measured in millimetres, based on the sum of the traditional TAD in the lateral view and the net value of two distances in the anteroposterior (AP) view. The first distance is from the lag screw tip to the opposite point on the femoral head along the lag screw axis, while the second distance is from that point to the femoral head apex. The first distance is a positive value, whereas the second distance is positive if the lag screw is superior and negative if it is inferior. Receiver operating characteristic (ROC) curve analysis was used to assess the reliability of various parameters for evaluating the lag screw position within the femoral head. Factors such as reduction quality, fracture pattern according to the AO/OTA classification, TAD, Calcar-Referenced TAD, Axis Blade Angle, Parker’s ratio in the AP view, Cleveland Zone 1, and modified TAD were statistically associated with lag screw cut-out. Among the tested parameters, the novel parameter exhibited 90.1% sensitivity and 90.9% specificity for predicting lag screw cut-out at a cut-off value of 25 mm, with a p-value < 0.001. The modified TAD demonstrated the highest reliability in predicting lag screw cut-out. A value of 25 mm may potentially reduce the risk of lag screw cut-out in trochanteric hip fractures


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 125 - 132
1 May 2024
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP

Aims

Uncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants – modular fluted tapered (MFT) femoral components – in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components.

Methods

We identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 82 - 88
1 May 2024
Villa JM Rajschmir K Hosseinzadeh S Manrique-Succar J Grieco P Higuera-Rueda CA Riesgo AM

Aims

Large bone defects resulting from osteolysis, fractures, osteomyelitis, or metastases pose significant challenges in acetabular reconstruction for total hip arthroplasty. This study aimed to evaluate the survival and radiological outcomes of an acetabular reconstruction technique in patients at high risk of reconstruction failure (i.e. periprosthetic joint infection (PJI), poor bone stock, immunosuppressed patients), referred to as Hip Reconstruction In Situ with Screws and Cement (HiRISC). This involves a polyethylene liner embedded in cement-filled bone defects reinforced with screws and/or plates for enhanced fixation.

Methods

A retrospective chart review of 59 consecutive acetabular reconstructions was performed by four surgeons in a single institution from 18 October 2018 to 5 January 2023. Cases were classified based on the Paprosky classification, excluding type 1 cases (n = 26) and including types 2 or 3 for analysis (n = 33). Radiological loosening was evaluated by an orthopaedic surgeon who was not the operating surgeon, by comparing the immediate postoperative radiographs with the ones at latest follow-up. Mean follow-up was 557 days (SD 441; 31 to 1,707).


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 54 - 58
1 May 2024
Wassilew GI Zimmerer A Fischer M Nonnenmacher L O'Hara L Hube R

Aims

The use of a porous metal shell supported by two augments with the ‘footing’ technique is one solution to manage Paprosky IIIB acetabular defects in revision total hip arthroplasty. The aim of this study was to assess the medium-term implant survival and radiological and clinical outcomes of this technique.

Methods

We undertook a retrospective, two-centre series of 39 hips in 39 patients (15 male, 24 female) treated with the ‘footing’ technique for Paprosky IIIB acetabular defects between 2007 and 2020. The median age at the time of surgery was 64.4 years (interquartile range (IQR) 54.4 to 71.0). The median follow-up was 3.9 years (IQR 3.1 to 7.0).


Bone & Joint 360
Vol. 13, Issue 2 | Pages 33 - 35
1 Apr 2024

The April 2024 Spine Roundup360 looks at: Lengthening behaviour of magnetically controlled growing rods in early-onset scoliosis: a multicentre study; LDL, cholesterol, and statins usage cause pseudarthrosis following lumbar interbody fusion; Decision-making in the treatment of degenerative lumbar spondylolisthesis of L4/L5; Does the interfacing angle between pedicle screws and support rods affect clinical outcomes after posterior thoracolumbar fusion?; Returning to the grind: how workload influences recovery post-lumbar spine surgery; Securing the spine: a leap forward with s2 alar-iliac screws in adult spinal deformity surgery.


Bone & Joint 360
Vol. 13, Issue 2 | Pages 41 - 44
1 Apr 2024

The April 2024 Children’s orthopaedics Roundup360 looks at: Ultrasonography or radiography for suspected paediatric distal forearm fractures?; Implant density in scoliosis: an important variable?; Gait after paediatric femoral shaft fracture treated with intramedullary nail fixation: a longitudinal prospective study; The opioid dilemma: navigating pain management for children’s bone fractures; 12- to 20-year follow-up of Dega acetabuloplasty in patients with developmental dysplasia of the hip; Physeal fractures of the distal ulna: incidence and risk factors for premature growth arrest; Analysis of growth after transphyseal anterior cruciate ligament reconstruction in children; Management of lateral condyle humeral fracture associated with elbow dislocation in children: a retrospective international multicentre cohort study.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims

To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time.

Methods

We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 312 - 318
1 Apr 2024
Sheth NP Jones SA Sanghavi SA Manktelow A

The advent of modular porous metal augments has ushered in a new form of treatment for acetabular bone loss. The function of an augment can be seen as reducing the size of a defect or reconstituting the anterosuperior/posteroinferior columns and/or allowing supplementary fixation. Depending on the function of the augment, the surgeon can decide on the sequence of introduction of the hemispherical shell, before or after the augment. Augments should always, however, be used with cement to form a unit with the acetabular component. Given their versatility, augments also allow the use of a hemispherical shell in a position that restores the centre of rotation and biomechanics of the hip. Progressive shedding or the appearance of metal debris is a particular finding with augments and, with other radiological signs of failure, should be recognized on serial radiographs. Mid- to long-term outcomes in studies reporting the use of augments with hemispherical shells in revision total hip arthroplasty have shown rates of survival of > 90%. However, a higher risk of failure has been reported when augments have been used for patients with chronic pelvic discontinuity.

Cite this article: Bone Joint J 2024;106-B(4):312–318.