Advertisement for orthosearch.org.uk
Results 1 - 20 of 36
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims

Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA.

Methods

This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 11 - 15
1 Jan 2024
Jain S Lamb JN Pandit H

Polished taper-slip (PTS) cemented stems have an excellent clinical track record and are the most common stem type used in primary total hip arthroplasty (THA) in the UK. Due to low rates of aseptic loosening, they have largely replaced more traditional composite beam (CB) cemented stems. However, there is now emerging evidence from multiple joint registries that PTS stems are associated with higher rates of postoperative periprosthetic femoral fracture (PFF) compared to their CB stem counterparts. The risk of both intraoperative and postoperative PFF remains greater with uncemented stems compared to either of these cemented stem subtypes. PFF continues to be a devastating complication following primary THA and is associated with high complication and mortality rates. Recent efforts have focused on identifying implant-related risk factors for PFF in order to guide preventative strategies, and therefore the purpose of this article is to present the current evidence on the effect of cemented femoral stem design on the risk of PFF.

Cite this article: Bone Joint J 2024;106-B(1):11–15.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 946 - 952
1 Sep 2023
Dhawan R Young DA Van Eemeren A Shimmin A

Aims

The Birmingham Hip Resurfacing (BHR) arthroplasty has been used as a surgical treatment of coxarthrosis since 1997. We present 20-year results of 234 consecutive BHRs performed in our unit.

Methods

Between 1999 and 2001, there were 217 patients: 142 males (65.4%), mean age 52 years (18 to 68) who had 234 implants (17 bilateral). They had patient-reported outcome measures collected, imaging (radiograph and ultrasound), and serum metal ion assessment. Survivorship analysis was performed using Kaplan-Meier estimates. Revision for any cause was considered as an endpoint for the analysis.


Aims

To establish the survivorship, function, and metal ion levels in an unselected series of metal-on-metal hip resurfacing arthroplasties (HRAs) performed by a non-designer surgeon.

Methods

We reviewed 105 consecutive HRAs in 83 patients, performed by a single surgeon, at a mean follow-up of 14.9 years (9.3 to 19.1). The cohort included 45 male and 38 female patients, with a mean age of 49.5 years (SD 12.5)


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1736 - 1741
1 Nov 2021
Tolk JJ Eastwood DM Hashemi-Nejad A

Aims

Perthes’ disease (PD) often results in femoral head deformity and leg length discrepancy (LLD). Our objective was to analyze femoral morphology in PD patients at skeletal maturity to assess where the LLD originates, and evaluate the effect of contralateral epiphysiodesis for length equalization on proximal and subtrochanteric femoral lengths.

Methods

All patients treated for PD in our institution between January 2013 and June 2020 were reviewed retrospectively. Patients with unilateral PD, LLD of ≥ 5 mm, and long-leg standing radiographs at skeletal maturity were included. Total leg length, femoral and tibial length, articulotrochanteric distance (ATD), and subtrochanteric femoral length were compared between PD side and the unaffected side. Furthermore, we compared leg length measurements between patients who did and who did not have a contralateral epiphysiodesis.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 73 - 73
1 Nov 2021
Camera A Tedino R Cattaneo G Capuzzo A Biggi S Tornago S
Full Access

Introduction and Objective. A proper restoration of hip biomechanics is fundamental to achieve satisfactory outcomes after total hip arthroplasty (THA). A global hip offset (GO) postoperatively reduction of more than 5 mm was known to impair hip functionality after THA. This study aimed to verify the restoration of the GO radiographic parameter after primary THA by the use of a cementless femoral stem available in three different offset options without length changing. Materials and Methods. From a consecutive series of 201 patients (201 hips) underwent primary cementless THA in our centre with a minimum 3-year follow up, 80 patients (80 hips) were available for complete radiographic evaluation for GO and limb length (LL) and clinical evaluation with Harris hip score (HHS). All patients received the same femoral stem with three different offset options (option A with – 5 mm offset, option B and option C with + 5 mm offset, constant for each sizes) without changing stem length. Results. Mean GO significantly increased by + 3 mm (P < 0.05) and mean LL significantly decreased by + 5 mm (P < 0.05) after surgery, meaning that postoperatively the limb length of the operated side increased by + 5 mm. HHS significantly improved from 56.3 points preoperatively to 95.8 postoperatively (P < 0.001). Offset option A was used in 1 hip (1%), B in 59 hips (74%) and C in 20 hips (25%). Conclusions. The femur is lateralized with a mean of + 5mm after surgery than, the native anatomy, whatever type of stem was used. Thus, the use of this 3-offset options femoral stem is effective in restoring the native biomechanical hip parameters as GO, even if 2 offset options were considered sufficient to restore GO


Bone & Joint Open
Vol. 2, Issue 7 | Pages 476 - 485
8 Jul 2021
Scheerlinck T De Winter E Sas A Kolk S Van Gompel G Vandemeulebroucke J

Aims

Hip arthroplasty does not always restore normal anatomy. This is due to inaccurate surgery or lack of stem sizes. We evaluated the aptitude of four total hip arthroplasty systems to restore an anatomical and medialized hip rotation centre.

Methods

Using 3D templating software in 49 CT scans of non-deformed femora, we virtually implanted: 1) small uncemented calcar-guided stems with two offset options (Optimys, Mathys), 2) uncemented straight stems with two offset options (Summit, DePuy Synthes), 3) cemented undersized stems (Exeter philosophy) with three offset options (CPT, ZimmerBiomet), and 4) cemented line-to-line stems (Kerboul philosophy) with proportional offsets (Centris, Mathys). We measured the distance between the templated and the anatomical and 5 mm medialized hip rotation centre.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 108 - 108
1 Apr 2019
Riviere C Maillot C Auvinet E Cobb J
Full Access

Introduction. The objective of our study was to determine the extent to which the quality of the biomechanical reconstruction when performing hip replacement influences gait performances. We aimed to answer the following questions: 1) Does the quality of restoration of hip biomechanics after conventional THR influence gait outcomes? (question 1), and 2) Is HR more beneficial to gait outcomes when compared with THR? (question 2). Methods. we retrospectively reviewed 52 satisfied unilateral prosthetic hip patients (40 THRs and 12 HRs) who undertook objective gait assessment at a mean follow-up of 14 months. The quality of the prosthetic hip biomechanical restoration was assessed on standing pelvic radiograph by comparison to the healthy contralateral hip. Results. We were unable to detect any statistically significant correlation between the radiographical parameters and the gait data, for THR patients. In stress conditions (inclination or declination of the ramp), the gait was more symmetric in the HR group, compared to the THR group. Discussion/Conclusions. We found that slight variations in the quality of the hip biomechanical restoration had little effect on gait outcomes of THR patients, and HR generated a more physiological gait under stress conditions than well-functioning THR


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 32 - 40
1 Jan 2019
Hellman MD Ford MC Barrack RL

Aims. Surface replacement arthroplasty (SRA), compared with traditional total hip arthroplasty (THA), is more expensive and carries unique concern related to metal ions production and hypersensitivity. Additionally, SRA is a more demanding procedure with a decreased margin for error compared with THA. To justify its use, SRA must demonstrate comparable component survival and some clinical advantages. We therefore performed a systematic literature review to investigate the differences in complication rates, patient-reported outcomes, stress shielding, and hip biomechanics between SRA and THA. Materials and Methods. A systematic review of the literature was completed using MEDLINE and EMBASE search engines. Inclusion criteria were level I to level III articles that reported clinical outcomes following primary SRA compared with THA. An initial search yielded 2503 potential articles for inclusion. Exclusion criteria included review articles, level IV or level V evidence, less than one year’s follow-up, and previously reported data. In total, 27 articles with 4182 patients were available to analyze. Results. Fracture and infection rates were similar between SRA and THA, while dislocation rates were lower in SRA compared with THA. SRA demonstrated equivalent patient-reported outcome scores with greater activity scores and a return to high-level activities compared with THA. SRA more reliably restored native hip joint biomechanics and decreased stress shielding of the proximal femur compared with THA. Conclusion. In young active men with osteoarthritis, there is evidence that SRA offers some potential advantages over THA, including: improved return to high level activities and sport, restoration of native hip biomechanics, and decreased proximal femoral stress shielding. Continued long-term follow up is required to assess ultimate survivorship of SRA


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 11 - 18
1 Jan 2019
Kayani B Konan S Thakrar RR Huq SS Haddad FS

Objectives

The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing conventional manual total hip arthroplasty (THA) versus robotic-arm assisted THA. Secondary objectives were to determine differences between these treatment techniques for THA in achieving the planned combined offset, component inclination, component version, and leg-length correction.

Materials and Methods

This prospective cohort study included 50 patients undergoing conventional manual THA and 25 patients receiving robotic-arm assisted THA. Patients undergoing conventional manual THA and robotic-arm assisted THA were well matched for age (mean age, 69.4 years (sd 5.2) vs 67.5 years (sd 5.8) (p = 0.25); body mass index (27.4 kg/m2 (sd 2.1) vs 26.9 kg/m2 (sd 2.2); p = 0.39); and laterality of surgery (right = 28, left = 22 vs right = 12, left = 13; p = 0.78). All operative procedures were undertaken by a single surgeon using the posterior approach. Two independent blinded observers recorded all radiological outcomes of interest using plain radiographs.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 79 - 79
1 Feb 2017
De Winter E Kolk S Van Gompel G Vandemeulebroucke J Scheerlinck T
Full Access

Introduction. Natural population variation in femoral morphology results in a large range of offsets, anteversion angles and lengths. During total hip arthroplasty, accurate restoration of hip biomechanics is essential to achieve good functional results. One option is to restore the anatomic hip rotation center. Alternatively, medializing the rotation center and compensating by increasing the femoral offset, reduces acetabular contact forces and increases the abductor lever arm. We investigated the ability of two cemented stem systems to restore hip biomechanics in an anatomic and medialized way. We compared an undersized “Exeter-type” of stem with three offset options and 18 sizes (CPT, Zimmer), to a line-to-line “Kerboul-type” of stem with proportional offset and 12 sizes (Centris, Mathys). Methods. Thirty CT scans of whole femora were segmented and the hip rotation center, proximal femoral axis and femoral length were determined with Mimics and 3-matic (Materialise). Using scripting functionality in the software, CAD design files of both stems were automatically sized and aligned along the proximal femoral axis to restore an anatomical and a 5 mm medialized hip rotation center. Stem size and position could be fine-tuned manually. The maximum distances between the prosthetic (PRC), the anatomic (ARC) and the medialized hip rotation center (MRC) were calculated (Fig. 1). Variations in femoral offset (ΔFO), anteroposterior (ΔAP) and proximodistal distance (ΔPD) were analyzed. Finally, the number of cases where the hip rotation center could be restored within 5 mm was reported. Results. Both implants allowed restoring the ARC accurately (mean distance PRC-ARC: CPT 0.97±0.88 mm, Centris 1.66±1.59 mm; mean difference ΔFO: CPT 0.09±0.19 mm, Centris 0.11±0.29 mm; mean difference ΔAP: CPT 0.12±1.22°, Centris 0.27±1.78 mm, mean difference ΔPD: CPT 0.04±0.44 mm, Centris 0.49±1.35 mm). The CPT stem allowed restoring the PRC within 5 mm of the ARC in all cases (max. 4.31 mm), whereas the Centris stem achieved this in only 28/30 hips (max. 6.72 mm) (Fig. 2). Aiming for a MRC was less satisfactory with both stems (mean distance PRC-MRC: CPT 1.38±1.63 mm, Centris 3.61±2.73 mm; mean difference ΔFO: CPT 0.09±0.10 mm, Centris 0.06±0.35 mm; mean difference ΔAP: CPT 0.17±2.02 mm, Centris 2.58±2.68 mm, mean difference ΔDP; CPT 0.28±0.67 mm, Centris 1.98±1.66 mm). The CPT stem allowed restoring the PRC within 5 mm of the MRC in 29/30 cases (max. 8.09 mm), whereas the Centris stem achieved this in only 25/30 cases (max. 11.15 mm) (Fig. 3). Discussion. Although both stem systems allowed restoring hip biomechanics accurately in most cases, the CPT system was superior to the Centris stem for achieving both ARC and MRC. This could be explained by more implant sizes (18 vs. 12) and undersized stems offering more freedom to correct version. Although medializing the hip rotation center offers biomechanical advantages, both stems had more difficulties achieving this. In some cases, differences between aimed and planned rotation centers were close to 1 cm which might negatively impact on clinical outcome. As such, to avoid suboptimal reconstructions with the available implants, templating is mandatory especially when aiming at a medialized reconstruction strategy


Bone & Joint 360
Vol. 5, Issue 3 | Pages 31 - 32
1 Jun 2016


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 32 - 32
1 May 2016
Ziaee H McMinn D Daniel J
Full Access

The use of modular systems adds versatility to the implant system, better restoration of hip biomechanics and lower inventory to the hospital. There have been reports of high metal ions, ARMD reactions and high implant failure rates due to potential problems from taper failures. These are more common in metal-on-metal hip replacements, but are being also reported in other bearings. Between 2001 and 2010, we performed 383 consecutive metal-on-metal (MoM) THRs through a posterior approach, using a BHR cup and Birmingham modular head with one of three different stems, all with 12/14 tapers. The earliest 104 hips employed a cemented MS30 stem (Zimmer GmbH, Winterthur, Switzerland). Subsequent 256 were Synergy and then 23 Anthology (both uncemented and both Smith and Nephew Orthopaedics, Memphis TN USA). There was no significant difference in the average age at surgery (65.4 years cemented vs 65.6 uncemented, p = 0.69), gender ratio (1.68 vs 1.89, p = 0.64), or bearing diameter (46.7 vs 46.8, p = 0.31). The earlier 203 Synergy stems were monoblock heads, while the remaining uncemented stems included a tapered sleeve in addition. There were 3 deep infections and 11 debris-related failures (overall revision rate 4.9%). The revision rate from aseptic failures (ALTR, effusion, osteolysis or component loosening) is 2.87%. Kaplan-Meier analysis of the entire cohort showed a 10-year implant survival of 96.8% with revision for any reason as the end-point. Cemented stems had a 100% survival at 10 years and 98.6% at 12 years. The uncemented stems had a 93.8% survival at 10 years. Within the uncemented group, the monoblocks had a 5 and 10-year survival of 99.0% and 96.4% respectively while the sleeved had 98.7% (5 years) and 96.3% (7 years) and 82.5% at 8 years. Retreival analysis showed clear evidence of taper failure. Our experience suggests taper failure leading to ALTRs and its sequelae. Others have reported ALTR type reactions in metal on polyethylene and ceramic on polyethylene bearing types as well in bearing diameters ranging from 28mm to 40mm. There is a need to improve taper design especially for use with large heads, and in high demand patients


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 58 - 58
1 May 2016
Mount L Su S Su E
Full Access

Introduction. Hip Resurfacing Arthroplasty (HRA) has been performed in the United States for over 10 years and is an alternative to standard Total Hip Arthropastly (THA). It is appealing to younger patients with end stage osteoarthritis who seek to maintain active lifestyles. Benefits of HRA versus THR include a larger femoral ball size, potential to return to impact activities, decreased dislocation rates, and restoration of normal hip biomechanics. Patients ≤50 years old are a particularly challenging patient group to treat with THA because of their young age and high activity level, and as such, are well-suited for HRA. However, there are limited reports in the literature about clinical, radiographic and functional outcomes for this patient cohort. We present results of a clinical investigation at our institution for this patient cohort with minimum 5-year follow up, including long term survivorship and outcome scores. Methods. HRA, using the Birmingham Hip Resurfacing (BHR), was performed for 538 procedures between 2006–2009 by a single surgeon at a United States teaching hospital. After Institutional Review Board approval, medical and radiographic study records were retrospectively reviewed. Harris Hip Scores (HHS) were routinely collected. Patients who had not returned for follow-up examination were contacted by telephone for information pertaining to their status and implant, and a modified HHS was also administered. A Kaplan Meier survival curve was constructed to evaluate time to revision. Statistical analysis was performed (SAS version 9.3; SAS Institute, Cary, NC). Results. Of the 538 patients who underwent HRA from 2006–2009, 238 were aged ≤50 years (44%). Five-year follow up data was obtained from 209 of these patients (88%), using medical record documentation, and telephone survey as needed. The mean follow-up for all patients was 6 years (range 5–8 years). A total of 3% (8/238) were revised. Reasons included: (i) femoral loosening in 4, (ii) Iliopsoas impingement in 1, (iii) metallosis/adverse tissue reaction in 1, (iv) femoral neck fracture following motor vehicle accident in 1, and (v) unknown reasons in 1. Of the 238 patients, 55 (23%) were female, 2 (2/55; 3.6%) of whom have since undergone revision surgery for either metallosis/adverse tissue reaction, or unknown reasons. Of the 53 women who retained their BHR at 5-year follow up, the average HHS was 96.5. Of the 238 patients, 183 (77%) were male patients, 6 (6/183; 3.2%) of whom have since undergone revision surgery for femoral component loosening, iliopsoas impingement, or femoral neck fracture sustained in a motor vehicle accident. At 5-year follow-up, 177 male patients retained their implant and had an average Harris Hip Score of 98.8. The overall implant survival was 96.6% at approximately 5 years. Conclusion. In our cohort of patients aged ≤50 treated with BHR [Fig. 1], our results demonstrated 5-year survivorship of 96.6%, with average HHS of 98.8 in males and 96.5 in females. This study demonstrates HRA is a successful alternative to traditional THA in a challenging cohort of younger, active patients


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 44 - 49
1 Jan 2016
Sheth NP Melnic CM Paprosky WG

Given the increasing number of total hip arthroplasty procedures being performed annually, it is imperative that orthopaedic surgeons understand factors responsible for instability. In order to treat this potentially complex problem, we recommend correctly classifying the type of instability present based on component position, abductor function, impingement, and polyethylene wear. Correct classification allows the treating surgeon to choose the appropriate revision option that ultimately will allow for the best potential outcome.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):44–9.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1608 - 1614
1 Dec 2015
Tice A Kim P Dinh† L Ryu JJ Beaulé PE

The primary purpose of this study of metal-on-metal (MoM) hip resurfacing was to compare the effect of using a cementless or cemented femoral component on the subsequent bone mineral density (BMD) of the femoral neck.

This was a single-centre, prospective, double-blinded control trial which randomised 120 patients (105 men and 15 women) with a mean age of 49.4 years (21 to 68) to receive either a cemented or cementless femoral component. Follow-up was to two years. Outcome measures included total and six-point region-of-interest BMD of the femoral neck, radiological measurements of acetabular inclination, neck-shaft and stem-shaft angles, and functional outcome scores including the Harris hip score, the Western Ontario and McMaster Universities Osteoarthritis Index and the University of California at Los Angeles activity scale.

In total, 17 patients were lost to follow-up leaving 103 patients at two years. There were no revisions in the cementless group and three revisions (5%) in the cemented group (two because of hip pain and one for pseudotumour).

The total BMD was significantly higher in the cementless group at six months (p < 0.001) and one year (p = 0.01) than in the cemented group, although there was a loss of statistical significance in the difference at two years (p = 0.155).

All patient outcomes improved significantly: there were no significant differences between the two groups.

The results show better preservation of femoral neck BMD with a cementless femoral component after two years of follow-up. Further investigation is needed to establish whether this translates into improved survivorship.

Cite this article: Bone Joint J 2015;97-B:1608–14.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1338 - 1344
1 Oct 2015
te Stroet MAJ Keurentjes JC Rijnen WHC Gardeniers JWM Verdonschot N Slooff TJJH Schreurs BW

We present the results of 62 consecutive acetabular revisions using impaction bone grafting and a cemented polyethylene acetabular component in 58 patients (13 men and 45 women) after a mean follow-up of 27 years (25 to 30). All patients were prospectively followed. The mean age at revision was 59.2 years (23 to 82).

We performed Kaplan–Meier (KM) analysis and also a Competing Risk (CR) analysis because with long-term follow-up, the presence of a competing event (i.e. death) prevents the occurrence of the endpoint of re-revision.

A total of 48 patients (52 hips) had died or had been re-revised at final review in March 2011. None of the deaths were related to the surgery. The mean Harris hip score of the ten surviving hips in ten patients was 76 points (45 to 99).

The KM survivorship at 25 years for the endpoint ‘re-revision for any reason’ was 58.0% (95% confidence interval (CI) 38 to 73) and for ‘re-revision for aseptic loosening’ 72.1% (95% CI 51 to 85). With the CR analysis we calculated the KM analysis overestimates the failure rate with respectively 74% and 93% for these endpoints. The current study shows that acetabular impaction bone grafting revisions provide good clinical results at over 25 years.

Cite this article: Bone Joint J 2015;97-B:1338–44.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 19 - 19
1 Dec 2014
Khan H Goudie S Deep K
Full Access

Introduction:. Restoration of normal hip biomechanics is vital for success of total hip arthroplasty (THA). This requires accurate placement of implants and restoration of limb length and offset. The purpose of this study was to assess the accuracy of computer navigation system in predicting cup placement and restoring limb length and offset. Material and Methods:. An analysis of 259 consecutive patients who had THA performed with imageless computer navigation system was carried out. Acetabular cup abduction and anteversion, medialisation or lateralisation of offset and limb length change were compared between navigation measurements and follow-up radiographs. Sensitivity, specificity, accuracy and PPV were calculated to assess navigation for cup orientation and student t-test used for evaluation of offset and limb length change. Results:. Mean cup abduction and anteversion was 40.35° (SD, 5.81) and 18.46° (SD, 6.79) in postop radiographs compared to 41° (SD, 5.03) and 14.76°(SD, 6.11) for navigation measurements. Intraoperative navigation measurements had high PPV and specificity for determining cup abduction and anteversion (PPV >95%, specificity >90%). Accuracy for determining cup abduction was 96.13% compared to 72.2% for cup anteversion. Change in limb length and offset was mean 6.46 mm (SD, 5.68) and −1.07 mm (SD, 5.75) on radiograph evaluation and 5.41 mm (SD, 5.11) and −2.24 mm (SD, 5.87) from navigation measurements respectively, the difference being not significant in both (p value >0.2). Radiograph and navigation had a mean difference of 1.01 mm (SD, 2.83) for offset measurements and a mean difference of 1.05 mm (SD, 4.37) for postop limb length assessment. Discussion:. To conclude, navigation can serve as an excellent tool for appropriate placement of implants and restoring limb length and offset in THA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 47 - 47
1 Aug 2013
Deep K Khan M Goudie S
Full Access

Introduction. Restoration of normal hip biomechanics is vital for success of total hip arthroplasty (THA). This requires accurate placement of implants and restoration of limb length and offset. The purpose of this study was to assess the precision and accuracy of computer navigation system in predicting cup placement and restoring limb length and offset. Material and Methods. An analysis of 259 consecutive patients who had THA performed with imageless computer navigation system was carried out. All surgeries were done by single surgeon (KD) using similar technique. Acetabular cup abduction and anteversion, medialisation or lateralisation of offset and limb length change were compared between navigation measurements and follow-up radiographs. Precision, accuracy, sensitivity and specificity were calculated to assess navigation for cup orientation and student t-test used for evaluation of offset and limb length change. A p value of <0.05 was considered significant for evaluation. Results. Mean cup abduction and anteversion was 40.35° (SD, 5.81) and 18.46° (SD, 6.79) in postop radiographs compared to 41° (SD, 5.03) and 14.76° (SD, 6.11) for navigation measurements. Intraoperative navigation measurements had high precision and specificity for determining cup abduction and anteversion (precision >95%, specificity >90%). Accuracy for determining cup abduction was 96.13% compared to 72.2% for cup anteversion. Change in limb length and offset was mean 6.46mm (SD, 5.68) and −1.07mm (SD, 5.75) on radiograph evaluation and 5.41mm (SD, 5.11) and −2.24mm (SD, 5.87) from navigation measurements respectively, the difference being not significant in both (p value > 0.2). Radiograph and navigation had a mean difference of 1.01mm (SD, 2.83) for offset measurements and a mean difference of 1.05mm (SD, 4.37) for postop limb length assessment. Discussion. To the best of our knowledge this is the largest single surgeon study of navigated THA. We found that computer navigation assessment of acetabular cup abduction and anteversion and limb length and offset restoration has high probability of predicting correct placement of implants. To conclude, navigation can serve as an excellent tool for appropriate placement of implants and restoring limb length and offset in THA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 47 - 47
1 Mar 2013
Daniel J Ziaee H Pradhan C McMinn D
Full Access

Introduction. Large diameter metal-on-metal hip arthroplasty (LDMMTHA) provides benefits of reduced dislocation rates and low wear. The use of modular systems allows better restoration of hip biomechanics. There have been reports of modular LDMMTHAs with tapered sleeves generating excessively high metal ions, due to possible mismatch between the titanium stem and the cobalt-chrome sleeve and the dual Morse tapers involved. We evaluated metal ion levels in LDMMTHA patients with and without a cobalt-chrome (CoCr) tapered sleeve. Methods. A cross-sectional series of 91 patients with proximal porous titanium alloy stem LDMMTHA with identical design CoCr bearings, attending a 1 to 2-year review were assessed with routine clinical and radiographic examinations, hip scores and metal ion analysis. Of these 65 had a single Morse taper between monoblock CoCr heads and the stems. Twentysix had a tapered cobalt-chrome sleeve in addition, with the resultant dual taper. Mean bearing diameter was 46 mm in both groups and mean age was 58 years in the monoblocks and 66 years in the tapered sleeve group. Results. Mean Oxford Hip score is worse in the tapered group (14.7) than in the monoblocks (12.6). All patients had well-functioning hips clinically and radiologically. Median blood cobalt and chromium are higher in the tapered sleeve (2.3μg/L and 1.8 μg/L) compared to the monoblocks (1.8 μg/L and 1.1 μg/L). Urine cobalt and chromium levels in the tapered sleeve (13.8 μg/24 hr and 5.3 μg/24 hr) also are higher than those in the monoblocks (12.2 μg/24 hr and 4.5 μg/24 hr respectively). Discussion and Conclusion. The limitation of this study is that it is a cross-sectional study. The results indicate that the use of a tapered sleeve in total hip arthroplasty does lead elevation of cobalt and chromium levels and the difference is statistically significant. However these levels are not as high as the levels reported with some other hip systems which have been withdrawn and the clinical significance of the elevated levels in the present study is unknown