Post-traumatic periprosthetic acetabular fractures are rare but serious. Few studies carried out on small cohorts have reported them in the literature. The aim of this work is to describe the specific characteristics of post-traumatic periprosthetic acetabular fractures, and the outcome of their surgical treatment in terms of function and complications. Patients with this type of fracture were identified retrospectively over a period of six years (January 2016 to December 2021). The following data were collected: demographic characteristics, date of insertion of the prosthesis, details of the intervention, date of the trauma, characteristics of the fracture, and type of treatment. Functional results were assessed with the Harris Hip Score (HHS). Data concerning complications of treatment were collected.Aims
Methods
The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling. A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles.Objectives
Methods
Objectives. The bony shoulder stability ratio (BSSR) allows for quantification of the bony stabilisers in vivo. We aimed to biomechanically validate the BSSR, determine whether joint incongruence affects the stability ratio (SR) of a shoulder model, and determine the correct parameters (glenoid concavity versus humeral head radius) for calculation of the BSSR in vivo. Methods. Four polyethylene balls (radii: 19.1 mm to 38.1 mm) were used to mould four fitting sockets in four different depths (3.2 mm to 19.1mm). The SR was measured in biomechanical congruent and incongruent experimental series. The experimental SR of a congruent system was compared with the calculated SR based on the BSSR approach. Differences in SR between congruent and incongruent experimental conditions were quantified. Finally, the experimental SR was compared with either calculated SR based on the socket concavity or plastic ball radius. Results. The experimental SR is comparable with the calculated SR (mean difference 10%, . sd. 8%; relative values). The experimental incongruence study observed almost no differences (2%, . sd. 2%). The calculated SR on the basis of the socket concavity radius is superior in predicting the experimental SR (mean difference 10%, . sd. 9%) compared with the calculated SR based on the plastic ball radius (mean difference 42%, . sd. 55%). Conclusion. The present biomechanical investigation confirmed the validity of the BSSR. Incongruence has no significant effect on the SR of a shoulder model. In the event of an incongruent system, the calculation of the BSSR on the basis of the glenoid concavity radius is recommended. Cite this article: L. Ernstbrunner, J-D. Werthel, T. Hatta, A. R. Thoreson, H.
Metabolic disorders are among known risk factors for tendinopathies or spontaneous tendon ruptures. However, the underlying cellular and molecular mechanisms remain unclear. We have previously shown that human and rat tendon cells produce and secrete insulin upon glucose stimulation. Therefore, we hypothesize that nutritional glucose uptake affects tendon healing in a rat model. Unilateral full-thickness Achilles tendon defects were created in 60 female rats. Animals were randomly assigned to three groups receiving different diets for 2 weeks (high glucose diet, low glucose/high fat diet, control diet). Gait analysis was performed at three time points (n=20/group). In addition, tendon thickness, biomechanical (n=14/group), and histological and immunohistochemical analysis was conducted. Subsequently, a subtractive-suppression-hybridization (SSH) screen comparing cDNA pools (n=5) prepared from repair tissues of the high glucose and the control diet group was conducted to identify differentially expressed genes.Introduction
Materials and Methods
Controversy surrounds the management of displaced
three- and four-part fractures of the proximal humerus. The percutaneous
Resch technique of stabilisation involves minimal soft-tissue dissection
and a reduced risk of stiffness and avascular necrosis. However,
it requires a second operation to remove Kirschner wires and the
humeral block. We describe a modification of this technique that
dispenses with the need for this second operation and relies on
a sequential pattern of screw placement. We report the outcome of
32 three- or four-part fractures of the proximal humerus treated
in this way at a mean follow-up of 3.8 years (2 to 8)). There were
14 men and 18 women with a mean age of 56 years (28 to 83). At final
follow-up the mean Oxford shoulder scores were 38 (31 to 44) and
39 (31 to 42), and the mean Constant scores were 79 (65 to 92) and
72 (70 to 80) for three- and four-part fractures, respectively. We
further analysed the results in patients aged <
60 years with
high-energy fractures and those aged ≥ 60 years with osteoporotic
fractures. There were no cases of nonunion or avascular necrosis. The results were good and comparable to those previously reported
for the
Depending on patient's age, risk factors and pretraumatic mobility, a total- or hemiarthroplasty of the hip have become the treatment of choice in femoral neck fractures(1–4). Internal fixation has shown to provide minor results. The majority of these patients are therefore treated by a hemiarthroplasty of the hip. Since the primary goal is to regain the pretraumatic level of mobility as soon as possible(3;5), we sought to investigate, if a minimal invasive anterior approach would be beneficial in regard of perioperative blood loss(6), postoperative pain(7;8) and thus postoperative mobility(9). In a randomised controlled trial, 48 patients were treated by a hemiarthroplasty of the hip via an anterior or lateral approach in supine position within 72 hours after trauma(10). Apart from parameters like age, ASA-Score or Body-mass-index, the main focus was set on perioperative blood loss, pain and postoperative mobilisation. All data collected were compared between groups to detect statistical significant differences. Additionally the same parameters were checked for significant differences comparing patients with or without complications within their group.Introduction
Patients and methods
Most proximal humeral fractures are stable injuries of the ageing population, and can be successfully treated non-operatively. The management of the smaller number of more complex displaced fractures is more controversial and new fixation techniques have greatly increased the range of fractures that may benefit from surgery. This article explores current concepts in the classification and clinical aspects of these injuries, reviewing the indications, innovations and outcomes for the most common methods of treatment.
The medial periosteal hinge plays a key role in fractures of the head of the humerus, offering mechanical support during and after reduction and maintaining perfusion of the head by the vessels in the posteromedial periosteum. We have investigated the biomechanical properties of the medial periosteum in fractures of the proximal humerus using a standard model in 20 fresh-frozen cadaver specimens comparable in age, gender and bone mineral density. After creating the fracture, we displaced the humeral head medial or lateral to the shaft with controlled force until complete disruption of the posteromedial periosteum was recorded. As the quality of periosteum might be affected by age and bone quality, the results were correlated with the age and the local bone mineral density of the specimens measured with quantitative CT. Periosteal rupture started at a mean displacement of 2.96 mm ( The mean bone mineral density was 0.111 g/cm3 ( This study showed that the posteromedial hinge is a mechanical structure capable of providing support for percutaneous reduction and stabilisation of a fracture by ligamentotaxis. Periosteal rupture started at a mean of about 3 mm and was completed by a mean displacement of just under 35 mm. The microvascular situation of the rupturing periosteum cannot be investigated with the current model.
The surgical treatment of three- and four-part fractures of the proximal humerus in osteoporotic bone is difficult and there is no consensus as to which technique leads to the best outcome in elderly patients. Between 1998 and 2004 we treated 76 patients aged over 70 years with three- or four-part fractures by percutaneous reduction and internal fixation using the Humerusblock. A displacement of the tuberosity of >
5 mm and an angulation of >
30° of the head fragment were the indications for surgery. Of the patients 50 (51 fractures) were available for follow-up after a mean of 33.8 months (5.8 to 81). The absolute, age-related and side-related Constant scores were recorded. Of the 51 fractures, 46 (90.2%) healed primarily. Re-displacement of fragments or migration of Kirschner wires was seen in five cases. Necrosis of the humeral head developed in four patients. In three patients a secondary arthroplasty had to be performed, in two because of re-displacement and in one for necrosis of the head. There was one case of deep infection which required a further operation and one of delayed healing. The mean Constant score of the patients with a three-part fracture was 61.2 points (35 to 87) which was 84.9% of the score for the non-injured arm. In four-part fractures it was 49.5 points (18 to 87) or 68.5% of the score for the non-injured arm. The Humerusblock technique can provide a comfortable and mobile shoulder in elderly patients and is a satisfactory alternative to replacement and traditional techniques of internal fixation.
Transfer of pectoralis major has evolved as the most favoured option for the management of the difficult problem of irreparable tears of subscapularis. We describe our experience with this technique in 30 patients divided into three groups. Group I comprised 11 patients with a failed procedure for instability of the shoulder, group II included eight with a failed shoulder replacement and group III, 11 with a massive tear of the rotator cuff. All underwent transfer of the sternal head of pectoralis major to restore the function of subscapularis. At the latest follow-up pain had improved in seven of the 11 patients in groups I and III, but in only one of eight in group II. The subjective shoulder score improved in seven patients in group I, in one in group II and in six in group III. The mean Constant score improved from 40.9 points (28 to 50) in group I, 32.9 (17 to 47) in group II and 28.7 (20 to 42) in group III pre-operatively to 60.8 (28 to 89), 41.9 (24 to 73) and 52.3 (24 to 78), respectively. Failure of the tendon transfer was highest in group II and was associated with pre-operative anterior subluxation of the humeral head. We conclude that in patients with irreparable rupture of subscapularis after shoulder replacement there is a high risk of failure of transfer of p?ctoralis major, particularly if there is pre-operative anterior subluxation of the humeral head.
After establishing anatomical feasibility, functional reconstruction to replace the anterolateral part of the deltoid was performed in 20 consecutive patients with irreversible deltoid paralysis using the sternoclavicular portion of the pectoralis major muscle. The indication for reconstruction was deltoid deficiency combined with massive rotator cuff tear in 11 patients, brachial plexus palsy in seven, and an isolated axillary nerve lesion in two. All patients were followed clinically and radiologically for a mean of 70 months (24 to 125). The mean gender-adjusted Constant score increased from 28% (15% to 54%) to 51% (19% to 83%). Forward elevation improved by a mean of 37°, abduction by 30° and external rotation by 9°. The pectoralis inverse plasty may be used as a salvage procedure in irreversible deltoid deficiency, providing subjectively satisfying results. Active forward elevation and abduction can be significantly improved.
Background and purpose: Dr. H.
We have examined 167 patients who had a hemiarthroplasty for three- and four-part fractures and fracture-dislocations of the head of the humerus in a multicentre study involving 12 Austrian hospitals. All patients were followed for more than a year. Anatomical healing of the tuberosity significantly influenced the outcome as measured by the Constant score and subjective patient satisfaction. With regard to pain, the outcome was generally satisfactory but only 41.9% of patients were able to flex the shoulder above 90°. The age of the patient and the type of prosthesis significantly influenced the healing of the tuberosity, but bone grafting did not. Achievement of healing of the tuberosity was inferior in institutions at which less than 15 hemiarthroplasties had been performed (Mann-Witney U test, p = 0.0001).
Untreated 3- and 4-part fractures of the proximal humerus have a poor functional outcome. Open operation increases the risk of avascular necrosis and percutaneous reduction and fixation may be preferable. We report 27 patients, 9 with 3-part and 18 with 4-part fractures, treated by percutaneous reduction and screw fixation. Thirteen of the 4-part fractures were of the valgus type with no significant lateral displacement of the articular segment, and five showed significant shift. Instruments were introduced into the fracture through small incisions so that the fragments could be manoeuvred under the control of an image intensifier, taking advantage of ligamentotaxis as far as possible. A good reduction was achieved in most cases. The average follow-up was 24 months (18 to 47). All the 3-part fractures showed good to very good functional results, with an average Constant score of 91% (84% to 100%), and no signs of avascular necrosis. Good radiological results were achieved in 4-part fractures when impacted in valgus except for one patient with partial avascular necrosis of the head. In those with lateral displacement of the head, revision to a prosthesis was required in one patient because of avascular necrosis and in another because of secondary redisplacement of the fracture. Avascular necrosis was seen in 11% of 4-part fractures. The average Constant score in patients with 4-part fractures who did not need further operation was 87% (75% to 100%).