The October 2024 Wrist & Hand Roundup360 looks at: Circumferential casting versus plaster splinting in preventing
The August 2024 Wrist & Hand Roundup360 looks at: Methotrexate shows potential in reducing pain for hand osteoarthritis with synovitis; Circumferential casting versus plaster splinting in adult distal radius fractures: the CAST study findings; Surgery shows superior long-term success for Dupuytren contracture compared to needle fasciotomy and collagenase injection; Evolving trends in surgical management of wrist arthritis: a decade-long national analysis; Mid-term outcomes of three commonly used surgical reconstructions for scapholunate instability; SLAC and SNAC: what is the evidence for treatment?; Steroids for trapeziometacarpal osteoarthritis?; When is it safe to return to driving after distal radius fracture fixation? A prospective study.
Aims. It is not clear which type of casting provides the best initial treatment in adults with a distal radial fracture. Given that between 32% and 64% of adequately reduced fractures redisplace during immobilization in a cast, preventing
To compare operative and nonoperative treatment for displaced distal radius fractures in patients aged over 65 years. A total of 100 patients were randomized in this non-inferiority trial, comparing cast immobilization with operation with a volar locking plate. Patients with displaced AO/OTA A and C fractures were eligible if one of the following were found after initial closed reduction: 1) dorsal angulation > 10°; 2) ulnar variance > 3 mm; or 3) intra-articular step-off > 2 mm. Primary outcome measure was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) after 12 months. Secondary outcome measures were the Patient-Rated Wrist and Hand Evaluation (PRWHE), EuroQol-5 dimensions 5-level questionnaire (EQ-5D-5L), range of motion (ROM), grip strength, “satisfaction with wrist function” (score 0 to 10), and complications.Aims
Methods
The purpose of this study was to compare the prevalence of hip displacement and dislocation in a total population of children with cerebral palsy (CP) in Scotland before and after the initiation of a hip surveillance programme. A total of 2,155 children with CP are registered in the Cerebral Palsy Integrated Pathway Scotland (CPIPS) surveillance programme, which began in 2013. Physical examination and hip radiological data are collected according to nationally agreed protocols.Aims
Patients
The aim of this prospective randomised controlled trial was to
compare non-operative and operative management for acute isolated
displaced fractures of the olecranon in patients aged ≥ 75 years. Patients were randomised to either non-operative management or
operative management with either tension-band wiring or fixation
with a plate. They were reviewed at six weeks, three and six months
and one year after the injury. The primary outcome measure was the
Disabilities of the Arm, Shoulder and Hand (DASH) score at one year.Aims
Patients and Methods
The aim of this study is to discuss the results of intramedullary devices in the management of paediatric radial neck fractures and to suggest methods to avoid the pitfalls of the technique. 30 patients with isolated Judet III and IV fractures were included in this retrospective study. The method of reduction was reviewed. The final results were graded using the Metaizeau functional scoring system and Oxford Elbow score. Intramedullary K wires were used in 10 patients and blunt tipped TENS nails in 20 patients. The complications seen were radiocapitellar joint penetration-6 cases at mean 4.87 weeks,
The purpose of the study was to identify risk factors that are associated with re-displacement of the hip after surgical reconstruction in cerebral palsy. Retrospective review of children with cerebral palsy who had hip reconstruction with proximal femoral varus derotation osteotomy (VDRO) and Dega-type pelvic osteotomy, between 2005–2012, at a UK and European institution, was performed. Patient demographics, GMFCS, clinical and radiological outcome were assessed as well as the presence of pelvic obliquity and significant scoliosis (Cobb angle > 10 degrees).
Distal radius and ulna fractures are a common paediatric injury. Displaced or angulated fractures require manipulation under anaesthetic (MUA) with or without Kirchner (K) wire fixation to improve alignment and avoid malunion. After treatment a proportion redisplace requiring further surgical management. This study aimed to investigate whether the risk of
The June 2014 Hip &
Pelvis Roundup360 looks at: Modular femoral necks: early signs are not good; is corrosion to blame for modular neck failures; metal-on-metal is not quite a closed book; no excess failures in fixation of displaced femoral neck fractures; noise no problem in hip replacement; heterotopic ossification after hip arthroscopy: are NSAIDs the answer?; thrombotic and bleeding events surprisingly low in total joint replacement; and the elephant in the room: complications and surgical volume.
The June 2013 Trauma Roundup360 looks at: open foot fractures; the diagnostic accuracy of continuous compartment pressure monitoring; conservative treatment for supracondylar fractures; high complication rates in patellar fractures; vitamin D and fracture; better function with K-wires; and tensionless bands.
Forearm fractures in children have a tendency
to displace in a cast leading to malunion with reduced functional
and cosmetic results. In order to identify risk factors for displacement,
a total of 247 conservatively treated fractures of the forearm in
246 children with a mean age of 7.3 years ( Fractures of both forearm bones in children have a strong tendency
to displace even in an above-elbow cast. Severe fractures of the
non-dominant arm are at highest risk for displacement. Radiographs
at set times during treatment might identify early displacement,
which should be treated before malunion occurs, especially in older children
with less potential for remodelling. Cite this article:
The purpose of this study was to evaluate the
risk of late displacement after the treatment of distal radial fractures with
a locking volar plate, and to investigate the clinical and radiological
factors that might correlate with re-displacement. From March 2007
to October 2009, 120 of an original cohort of 132 female patients
with unstable fractures of the distal radius were treated with a
volar locking plate, and were studied over a follow-up period of
six months. In the immediate post-operative and final follow-up
radiographs, late displacement was evaluated as judged by ulnar
variance, radial inclination, and dorsal angulation. We also analysed
the correlation of a variety of clinical and radiological factors
with re-displacement. Ulnar variance was significantly overcorrected
(p <
0.001) while radial inclination and dorsal angulation were
undercorrected when compared statistically (p <
0.001) with the unaffected
side in the immediate post-operative stage. During follow-up, radial
shortening and dorsal angulation progressed statistically, but none
had a value beyond the acceptable range. Bone mineral density measured
at the proximal femur and the position of the screws in the subchondral
region, correlated with slight progressive radial shortening, which
was not clinically relevant. Volar locking plating of distal radial fractures is a reliable
form of treatment without substantial late displacement. Cite this article:
Distal metaphyseal radial fractures are common in the paediatric population and the management of these fractures is controversial. The incidence of re-displacement in the closed management of these fractures is as much as 30% in some studies. Various methods have been described with the view to predict fracture displacement of distal radial fractures in children. One of these indices is the three point index (TPI). This index seeks to assess the adequacy of 3 point moulding and thus predict fracture displacement. It is a calculated ratio that if above 0.8 states that there is an increased risk of fracture re-displacement. The purpose of this study is to assess the accuracy of this index in predicting displacement of distal radial fractures in children. This retrospective study included 65 patients of both sexes under the age of 13 for a period of one year from January 2011 to January 2012. All patients with a dorsally displaced fracture of the distal radius were included. 22 patients were excluded because of loss to follow-up or absence of a complete series of x-rays. All patients were taken to theatre for a general anaesthetic and manipulation of their fractures using an image intensifier to confirm reduction. X-rays of initial fracture displacement, post manipulation position and follow-up fracture position at 2 and 6 weeks were assessed. The sensitivity, specificity, negative and positive predictive values of the TPI in screening for fracture re-displacement were calculated.Purpose
Methods