Advertisement for orthosearch.org.uk
Results 1 - 20 of 306
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1293 - 1300
1 Nov 2024
O’Malley O Craven J Davies A Sabharwal S Reilly P

Aims

Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA.

Methods

MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1257 - 1262
1 Nov 2024
Nowak LL Moktar J Henry P Dejong T McKee MD Schemitsch EH

Aims

We aimed to compare reoperations following distal radial fractures (DRFs) managed with early fixation versus delayed fixation following initial closed reduction (CR).

Methods

We used administrative databases in Ontario, Canada, to identify DRF patients aged 18 years or older from 2003 to 2016. We used procedural and fee codes within 30 days to determine which patients underwent early fixation (≤ seven days) or delayed fixation following CR. We grouped patients in the delayed group by their time to definitive fixation (eight to 14 days, 15 to 21 days, and 22 to 30 days). We used intervention and diagnostic codes to identify reoperations within two years. We used multivariable regression to compare the association between early versus delayed fixation and reoperation for all patients and stratified by age (18 to 60 years and > 60 years).


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears.

The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use.

Cite this article: Bone Joint J 2024;106-B(9):970–977.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 842 - 848
1 Aug 2024
Kriechling P Whitefield R Makaram NS Brown IDM Mackenzie SP Robinson CM

Aims

Vascular compromise due to arterial injury is a rare but serious complication of a proximal humeral fracture. The aims of this study were to report its incidence in a large urban population, and to identify clinical and radiological factors which are associated with this complication. We also evaluated the results of the use of our protocol for the management of these injuries.

Methods

A total of 3,497 adult patients with a proximal humeral fracture were managed between January 2015 and December 2022 in a single tertiary trauma centre. Their mean age was 66.7 years (18 to 103) and 2,510 (72%) were female. We compared the demographic data, clinical features, and configuration of those whose fracture was complicated by vascular compromise with those of the remaining patients. The incidence of vascular compromise was calculated from national population data, and predictive factors for its occurrence were investigated using univariate analysis.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 26 - 29
1 Feb 2024

The February 2024 Shoulder & Elbow Roundup360 looks at: Does indomethacin prevent heterotopic ossification following elbow fracture fixation?; Arthroscopic capsular shift in atraumatic shoulder joint instability; Ultrasound-guided lavage with corticosteroid injection versus sham; Combined surgical and exercise-based interventions following primary traumatic anterior shoulder dislocation: a systematic review and meta-analysis; Are vascularized fibula autografts a long-lasting reconstruction after intercalary resection of the humerus for primary bone tumours?; Anatomical versus reverse total shoulder arthroplasty with limited forward elevation; Tension band or plate fixation for simple displaced olecranon fractures?; Is long-term follow-up and monitoring in shoulder and elbow arthroplasty needed?


Bone & Joint 360
Vol. 12, Issue 6 | Pages 31 - 34
1 Dec 2023

The December 2023 Shoulder & Elbow Roundup360 looks at: Clavicle fractures: is the evidence changing practice?; Humeral shaft fractures, and another meta-analysis…let’s wait for the trials now!; Hemiarthroplasty or total elbow arthroplasty for distal humeral fractures…what does the registry say?; What to do with a first-time shoulder dislocation?; Deprivation indices and minimal clinically important difference for patient-reported outcomes after arthroscopic rotator cuff repair; Prospective randomized clinical trial of arthroscopic repair versus debridement for partial subscapularis tears; Long-term follow-up following closed reduction and early movement for simple dislocation of the elbow; Sternoclavicular joint reconstruction for traumatic acute and chronic anterior and posterior instability.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 839 - 842
1 Aug 2023
Jenkins PJ Duckworth AD

Shoulder injury related to vaccine administration (SIRVA) is a prolonged episode of shoulder dysfunction that commences within 24 to 48 hours of a vaccination. Symptoms include a combination of shoulder pain, stiffness, and weakness. There has been a recent rapid increase in reported cases of SIRVA within the literature, particularly in adults, and is likely related to the mass vaccination programmes associated with COVID-19 and influenza. The pathophysiology is not certain, but placement of the vaccination in the subdeltoid bursa or other pericapsular tissue has been suggested to result in an inflammatory capsular process. It has been hypothesized that this is associated with a vaccine injection site that is “too high” and predisposes to the development of SIRVA. Nerve conduction studies are routinely normal, but further imaging can reveal deep-deltoid collections, rotator cuff tendinopathy and tears, or subacromial subdeltoid bursitis. However, all of these are common findings within a general asymptomatic population. Medicolegal claims in the UK, based on an incorrect injection site, are unlikely to meet the legal threshold to determine liability.

Cite this article: Bone Joint J 2023;105-B(8):839–842.


Bone & Joint 360
Vol. 12, Issue 3 | Pages 27 - 30
1 Jun 2023

The June 2023 Shoulder & Elbow Roundup. 360. looks at: Proximal humerus fractures: what does the literature say now?; Infection risk of steroid injections and subsequent reverse shoulder arthroplasty; Surgical versus non-surgical management of humeral shaft fractures; Core outcome set needed for elbow arthroplasty; Minimally invasive approaches to locating radial nerve in the posterior humeral approach; Predictors of bone loss in anterior glenohumeral instability; Does the addition of motor control or strengthening exercises improve rotator cuff-related shoulder pain?; Terminology and diagnostic criteria used in patients with subacromial pain syndrome


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 37 - 37
4 Apr 2023
Pastor T Zderic I van Knegsel K Richards G Gueorguiev B Knobe M
Full Access

Proximal humeral shaft fractures are commonly treated with long straight plates or intramedullary nails. Helical plates might overcome the downsides of these techniques as they are able to avoid the radial nerve distally. The aim of this study was to investigate in an artificial bone model: (1) the biomechanical competence of different plate designs and (2) to compare them against the alternative treatment option of intramedullary nails. Twenty-four artificial humeri were assigned in 4 groups and instrumented as follows: group1 (straight 10-hole-PHILOS), group2 (MULTILOCK-nail), group3 (45°-helical-PHILOS) and group4 (90°-helical-PHILOS). An unstable proximal humeral shaft fracture was simulated. Specimens were tested under quasi-static loading in axial compression, internal/external rotation and bending in 4 directions monitored by optical motion tracking. Axial displacement (mm) was significantly lower in group2 (0.1±0.1) compared to all other groups (1: 3.7±0.6; 3: 3.8±0.8; 4: 3.5±0.4), p<0.001. Varus stiffness in group2 (0.8±0.1) was significantly higher compared to groups1+3, p≤0.013 (1: 0.7±0.1; 3: 0.7±0.1; 4: 0.8±0.1). Varus bending (°) was significantly lower in group2 compared to all other groups (p<0.001) and group4 to group1, p=0.022. Flexion stiffness in group1 was significantly higher compared to groups2+4 (p≤0,03) and group4 to group1, p≤0,029 (1: 0.8±0.1; 2: 0.7±0.1; 3: 0.7±0.1; 4: 0.6±0.1). Flexion bending (°) in group4 was higher compared to all other groups (p≤0.024) and lower in group2 compared to groups1+4, p≤0.024. Torsional stiffness remained non significantly different, p≥0.086. Torsional deformation in group2 was significantly higher compared to all other groups, p≤0.017. Shear displacement remained non significantly different, p≥0.112. From a biomechanical perspective, helical plating with 45° and 90° may be considered as a valid alternative fixation technique to standard straight plating of proximal third humeral fractures. Intramedullary nails demonstrated higher axial and bending stiffness as well as lower fracture gap movements during axial loading compared to all plate designs. However, despite similar torsional stiffness they were associated with higher torsional movements during internal/external rotation as compared to all investigated plate designs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 96 - 96
4 Apr 2023
Pastor T Kastner P Souleiman F Gehweiler D Link B Beeres F Babst R Gueorguiev B Knobe M
Full Access

Helical plates are preferably used for proximal humeral shaft fracture fixation and potentially avoid radial nerve irritation as compared to straight plates. Aims:(1) to investigate the safety of applying different long plate designs (straight, 45°-, 90°-helical and ALPS) in MIPO-technique to the humerus. (2) to assess and compare their distances to adjacent anatomical structures at risk. MIPO was performed in 16 human cadaveric humeri using either a straight plate (group1), a 45°-helical (group2), a 90°-helical (group3) or an ALPS (group4). Using CT-angiography, distances between brachial arteries and plates were evaluated. Following, all specimens were dissected, and distances to the axillary, radial and musculocutaneous nerve were evaluated. None of the specimens demonstrated injuries of the anatomical structures at risk after MIPO with all investigated plate designs. Closest overall distance (mm(range)) between each plate and the radial nerve was 1(1-3) in group1, 7(2-11) in group2, 14(7-25) in group3 and 6(3-8) in group4. It was significantly longer in group3 and significantly shorter in group1 as compared to all other groups, p<0.001. Closest overall distance (mm(range)) between each plate and the musculocutaneous nerve was 16(8-28) in group1, 11(7-18) in group2, 3(2-4) in group3 and 6(3-8) in group4. It was significantly longer in group1 and significantly shorter in group3 as compared to all other groups, p<0.001. Closest overall distance (mm(range)) between each plate and the brachial artery was 21(18-23) in group1, 7(6-7) in group2, 4(3-5) in group3 and 7(6-7) in group4. It was significantly longer in group1 and significantly shorter in group3 as compared to all other groups, p<0.021. MIPO with 45°- and 90°-helical plates as well as ALPS is safely feasible and showed a significant greater distance to the radial nerve compared to straight plates. However, distances remain low, and attention must be paid to the musculocutaneous nerve and the brachial artery when MIPO is used with ALPS, 45°- and 90°-helical implants. Anterior parts of the deltoid insertion will be detached using 90°-helical and ALPS implants in MIPO-technique


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 36 - 36
4 Apr 2023
Pastor T Zderic I van Knegsel K Link B Beeres F Migliorini F Babst R Nebelung S Ganse B Schöneberg C Gueorguiev B Knobe M
Full Access

Proximal humeral shaft fractures are commonly treated with long straight locking plates endangering the radial nerve distally. The aim of this study was to investigate the biomechanical competence in a human cadaveric bone model of 90°-helical PHILOS plates versus conventional straight PHILOS plates in proximal third comminuted humeral shaft fractures. Eight pairs of humeral cadaveric humeri were instrumented using either a long 90°-helical plate (group1) or a straight long PHILOS plate (group2). An unstable proximal humeral shaft fracture was simulated by means of an osteotomy maintaining a gap of 5cm. All specimens were tested under quasi-static loading in axial compression, internal and external rotation as well as bending in 4 directions. Subsequently, progressively increasing internal rotational loading until failure was applied and interfragmentary movements were monitored by means of optical motion tracking. Flexion/extension deformation (°) in group1 was (2.00±1.77) and (0.88±1.12) in group2, p=0.003. Varus/valgus deformation (°) was (6.14±1.58) in group1 and (6.16±0.73) in group2, p=0.976. Shear (mm) and displacement (°) under torsional load were (1.40±0.63 and 8.96±0.46) in group1 and (1.12±0.61 and 9.02±0.48) in group2, p≥0.390. However, during cyclic testing shear and torsional displacements and torsion were both significantly higher in group 1, p≤0.038. Cycles to catastrophic failure were (9960±1967) in group1 and (9234±1566) in group2, p=0.24. Although 90°-helical plating was associated with improved resistance against varus/valgus deformation, it demonstrated lower resistance to flexion/extension and internal rotation as well as higher flexion/extension, torsional and shear movements compared to straight plates. From a biomechanical perspective, 90°-helical plates performed inferior compared to straight plates and alternative helical plate designs with lower twist should be investigated in future paired cadaveric studies


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 455 - 464
15 Mar 2023
de Joode SGCJ Meijer R Samijo S Heymans MJLF Chen N van Rhijn LW Schotanus MGM

Aims

Multiple secondary surgical procedures of the shoulder, such as soft-tissue releases, tendon transfers, and osteotomies, are described in brachial plexus birth palsy (BPBP) patients. The long-term functional outcomes of these procedures described in the literature are inconclusive. We aimed to analyze the literature looking for a consensus on treatment options.

Methods

A systematic literature search in healthcare databases (PubMed, Embase, the Cochrane library, CINAHL, and Web of Science) was performed from January 2000 to July 2020, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The quality of the included studies was assessed with the Cochrane ROBINS-I risk of bias tool. Relevant trials studying BPBP with at least five years of follow-up and describing functional outcome were included.


Aims

Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon.

Methods

SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow range of motion, and re-operations related to the injury or to remove metalwork. An economic evaluation will assess the cost-effectiveness of treatments.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 2 - 2
1 Dec 2022
Schneider P Bergeron S Liew A Kreder H Berry, G
Full Access

Fractures of the humeral diaphysis occur in a bimodal distribution and represent 3-5% of all fractures. Presently, the standard treatment of isolated humeral diaphyseal fractures is nonoperative care using splints, braces, and slings. Recent data has questioned the effectiveness of this strategy in ensuring fracture healing and optimal patient function. The primary objective of this randomized controlled trial (RCT) was to assess whether operative treatment of humeral shaft fractures with a plate and screw construct provides a better functional outcome than nonoperative treatment. Secondary objectives compared union rates and both clinical and patient-reported outcomes. Eligible patients with an isolated, closed humeral diaphyseal fracture were randomized to either nonoperative care (initial sugar-tong splint, followed by functional coaptation brace) or open reduction and internal fixation (ORIF; plate and screw construct). The primary outcome measure was the Disability Shoulder, Arm, Hand (DASH) score assessed at 2-, 6-, 16-, 24-, and 52-weeks. Secondary outcomes included the Short Musculoskeletal Functional Assessment (SMFA), the Constant Shoulder Score, range of motion (ROM), and radiographic parameters. Independent samples t-tests and Chi-squared analyses were used to compare treatment groups. The DASH, SMFA, and Constant Score were modelled over time using a multiple variable mixed effects model. A total of 180 patients were randomized, with 168 included in the final analysis. There were 84 patients treated nonoperatively and 84 treated with ORIF. There was no significant difference between the two treatment groups for age (mean = 45.4 years, SD 16.5 for nonoperative group and 41.7, SD 17.2 years for ORIF group; p=0.16), sex (38.1% female in nonoperative group and 39.3% female in ORIF group; p=0.87), body mass index (mean = 27.8, SD 8.7 for nonoperative group and 27.2, SD 6.2 for ORIF group; p=0.64), or smoking status (p=0.74). There was a significant improvement in the DASH scores at 6 weeks in the ORIF group compared to the nonoperative group (mean=33.8, SD 21.2 in the ORIF group vs. mean=56.5, SD=21.1 in the nonoperative group; p < 0 .0001). At 4 months, the DASH scores were also significantly better in the ORIF group (mean=21.6, SD=19.7 in the ORIF group vs. mean=31.6, SD=24.6 in the nonoperative group; p=0.009. However, there was no difference in DASH scores at 12-month follow-up between the groups (mean=8.8,SD=10.9 vs. mean=11.0, SD=16.9 in the nonoperative group; p=0.39). Males had improved DASH scores at all timepoints compared with females. There was significantly quicker time to union (p=0.016) and improved position (p < 0 .001) in the ORIF group. There were 13 (15.5%) nonunions in the nonoperative group and four (4.7%) combined superficial and deep infections in the ORIF group. There were seven radial nerve palsies in the nonoperative group and five (a single iatrogenic) radial nerve palsies in the ORIF group. This large RCT comparing operative and nonoperative treatment of humeral diaphyseal fractures found significantly improved functional outcome scores in patients treated surgically at 6 weeks and 4 months. However, the early functional improvement did not persist at the 12-month follow-up. There was a 15.5% nonunion rate, which required surgical intervention, in the nonoperative group and a similar radial nerve palsy rate between groups


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 77 - 77
1 Dec 2022
Schneider P Bergeron S Liew A Kreder H Berry G
Full Access

Fractures of the humeral diaphysis occur in a bimodal distribution and represent 3-5% of all fractures. Presently, the standard treatment of isolated humeral diaphyseal fractures is nonoperative care using splints, braces, and slings. Recent data has questioned the effectiveness of this strategy in ensuring fracture healing and optimal patient function. The primary objective of this randomized controlled trial (RCT) was to assess whether operative treatment of humeral shaft fractures with a plate and screw construct provides a better functional outcome than nonoperative treatment. Secondary objectives compared union rates and both clinical and patient-reported outcomes. Eligible patients with an isolated, closed humeral diaphyseal fracture were randomized to either nonoperative care (initial sugar-tong splint, followed by functional coaptation brace) or open reduction and internal fixation (ORIF; plate and screw construct). The primary outcome measure was the Disability Shoulder, Arm, Hand (DASH) score assessed at 2-, 6-, 16-, 24-, and 52-weeks. Secondary outcomes included the Short Musculoskeletal Functional Assessment (SMFA), the Constant Shoulder Score, range of motion (ROM), and radiographic parameters. Independent samples t-tests and Chi-squared analyses were used to compare treatment groups. The DASH, SMFA, and Constant Score were modelled over time using a multiple variable mixed effects model. A total of 180 patients were randomized, with 168 included in the final analysis. There were 84 patients treated nonoperatively and 84 treated with ORIF. There was no significant difference between the two treatment groups for age (mean = 45.4 years, SD 16.5 for nonoperative group and 41.7, SD 17.2 years for ORIF group; p=0.16), sex (38.1% female in nonoperative group and 39.3% female in ORIF group; p=0.87), body mass index (mean = 27.8, SD 8.7 for nonoperative group and 27.2, SD 6.2 for ORIF group; p=0.64), or smoking status (p=0.74). There was a significant improvement in the DASH scores at 6 weeks in the ORIF group compared to the nonoperative group (mean=33.8, SD 21.2 in the ORIF group vs. mean=56.5, SD=21.1 in the nonoperative group; p < 0 .0001). At 4 months, the DASH scores were also significantly better in the ORIF group (mean=21.6, SD=19.7 in the ORIF group vs. mean=31.6, SD=24.6 in the nonoperative group; p=0.009. However, there was no difference in DASH scores at 12-month follow-up between the groups (mean=8.8,SD=10.9 vs. mean=11.0, SD=16.9 in the nonoperative group; p=0.39). Males had improved DASH scores at all timepoints compared with females. There was significantly quicker time to union (p=0.016) and improved position (p < 0 .001) in the ORIF group. There were 13 (15.5%) nonunions in the nonoperative group and four (4.7%) combined superficial and deep infections in the ORIF group. There were seven radial nerve palsies in the nonoperative group and five (a single iatrogenic) radial nerve palsies in the ORIF group. This large RCT comparing operative and nonoperative treatment of humeral diaphyseal fractures found significantly improved functional outcome scores in patients treated surgically at 6 weeks and 4 months. However, the early functional improvement did not persist at the 12-month follow-up. There was a 15.5% nonunion rate, which required surgical intervention, in the nonoperative group and a similar radial nerve palsy rate between groups


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 29 - 29
1 Nov 2022
Khan S Kapoor L Kumar V
Full Access

Abstract. Background. Reconstruction following resection of sarcomas of the upper extremity with methods described in the prevalent literature may not be possible in few selected cases. We describe Surgical Phocomelia or Phoco-reduction as a method of limb salvage in such cases of extensive sarcomas of the upper limb with its functional and oncological outcomes. Methods. Evaluation of functional and oncological outcomes was performed for 11 patients who underwent surgical phocomelia or phocoreduction for extensive sarcomas of the upper limb between 2010 and 2019. Results. Mean follow-up period in the study was27.8 months. Five patients required a segmental resection including the entire humerus while 6 patients underwent segmental resection around the elbow with a mean resection length of 21.5 cm. Mean MSTS 93 score was 22 depicting a good functional outcome. Mean hand grip strength on the operated side was 62% of the contralateral side with preservation of useful hand function. Mean time to humero-ulnar union was 6.7 months. Radial nerve palsy and implant failure occurred in 1 patient each. No patient developed local recurrence while 3 patients died of metastasis. Conclusion. Surgical phocomelia is a prudent alternative to severely incapacitating amputations in situations where other reconstruction methods are not feasible


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims

Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research.

Methods

A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review.


Bone & Joint Open
Vol. 3, Issue 7 | Pages 566 - 572
18 Jul 2022
Oliver WM Molyneux SG White TO Clement ND Duckworth AD

Aims

The primary aim was to estimate the cost-effectiveness of routine operative fixation for all patients with humeral shaft fractures. The secondary aim was to estimate the health economic implications of using a Radiographic Union Score for HUmeral fractures (RUSHU) of < 8 to facilitate selective fixation for patients at risk of nonunion.

Methods

From 2008 to 2017, 215 patients (mean age 57 yrs (17 to 18), 61% female (n = 130/215)) with a nonoperatively managed humeral diaphyseal fracture were retrospectively identified. Union was achieved in 77% (n = 165/215) after initial nonoperative management, with 23% (n = 50/215) uniting after surgery for nonunion. The EuroQol five-dimension three-level health index (EQ-5D-3L) was obtained via postal survey. Multiple regression was used to determine the independent influence of patient, injury, and management factors upon the EQ-5D-3L. An incremental cost-effectiveness ratio (ICER) of < £20,000 per quality-adjusted life-year (QALY) gained was considered cost-effective.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims. The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection. Methods. From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients. Results. Preparation of the prosthesis was a mean of 8.0 days (SD 1.5), during which time no patients experienced tumour progression. The mean operating time and intraoperative blood loss were 158.1 minutes (SD 67.6) and 176.9 ml (SD 187.8), respectively. All of the prostheses were implanted successfully. During a mean follow-up of 25.7 months (SD 7.8), no patients died, but four had complications (two superficial wound problems, one temporary palsy of radial nerve, and one dislocation). No aseptic loosening, structural failure, infection, heterotopic ossification, or degenerative arthritis was seen in this study. The mean flexion of the elbow was 119.6° (SD 15.9°) and the mean extension lag was 11.9° (SD 13.8°). The mean Musculoskeletal Tumor Society 93 score and Mayo Elbow Performance Score were 28.4 (SD 0.9) and 97.7 (SD 4.4), respectively. Conclusion. The custom-made, 3D-printed megaprosthesis with hemiarthroplasty is a feasible option for functional reconstruction after resection of a tumour in the distal humerus or proximal ulna. Cite this article: Bone Joint J 2022;104-B(6):747–757


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 11 - 11
1 Apr 2022
Baumgart R
Full Access

Introduction. Fully implantable distraction nails are frequently used for lengthening of the lower leg. What are the indications for humerus lengthening and which results can be expected?. Materials and Methods. The humerus as the best healing bone in the human body is suitable for lengthening with a nail as well but the indications are rare in comparison with the lower legs. Especially when driving a car or when working on a tablet length discrepancy of the arms of more than 4–5cm may cause severe hardening of the cervical muscles and induce chronical pain in the upper spine. Results. A distraction nail (FITBONE) was used in 5 cases for humerus lengthening. The nail was inserted in all cases from proximal. The mean age of the patients was 34 years. The mean lengthening amount was 58mm (55–100). In one case the system was exchanged to reach the desired length. There was no infection, no radial nerve irritation and no chronical shoulder pain. The system was removed in 4 cases in an average of 15 months the other nail will be removed soon as well. Conclusions. The preliminary results of our 5 cases demonstrate, that the FITBONE device is advantageous for lengthening the humerus, if the initial length is sufficient for implantation. In comparison with the use of external fixators the functional outcome, the comfort of treatment and the cosmetic result is amazing