Advertisement for orthosearch.org.uk
Results 1 - 20 of 7878
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 85 - 85
19 Aug 2024
Schemitsch E Nowak L Shehata M Sprague S Bzovsky S Bhandari M
Full Access

We aimed to examine outcomes between displaced femoral neck fracture (FNF) patients managed with total hip arthroplasty (THA) or hemi-arthroplasty (HA) via the anterolateral vs. posterior approach. We used data from the HEALTH trial (1,441 patients aged ≥50 with displaced FNFs randomized to THA vs. HA). We calculated each patient's propensity to undergo arthroplasty via the posterior approach, and matched them to 1 control (anterolateral approach) based on age (±5 years), and propensity score. We used Chi-Square/Fisher-Exact tests to compare dichotomous outcomes, and repeated measures ANOVA to examine differences in patient-reported outcomes (via the WOMAC subscores) from baseline to one-year postoperative. We used logistic regression to identify independent predictors of reoperation for instability in the posterior group. We identified 1,306 patients for this sub-analysis, 876 (67.1%) who received arthroplasty via an anterolateral approach, and 430 (32.9%) a posterior approach. The unadjusted rate of reoperation was significantly higher in the posterior group (10.7% vs. 7.1%). Following propensity score matching, we retained 790 patients (395 per group), with no between-group differences in patient, fracture, or implant characteristics. The matched cohort had a higher rate of comorbidities, and were less likely to be employed vs. the unmatched cohort. The rate of treatment for dislocation remained higher in the posterior group (6.1% vs. 2.0%) following matching. Repeated measures ANOVA revealed significantly better WOMAC pain, stiffness, function, and total scores in the posterior group. Between-group differences at 12-months were: pain - 0.59 (0.03–1.15); stiffness - 0.62 (0.35–0.87); function - 2.99 (0.12–5.86); total - 3.90 (0.24–7.56). We identified THA (vs. HA, odds ratio 2.05 [1.05–4.01]) as the only independent predictor of treatment for dislocation in the posterior group. Our analyses revealed that compromised patients with displaced FNFs who undergo arthroplasty via the posterior approach may report better symptoms at one-year vs. the anterolateral approach, despite a higher odds of reoperation for instability


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 30 - 30
19 Aug 2024
Timperley AJ
Full Access

The SPAIRE technique (Saving Piriformis And Internus, Repair Externus) was first described in 2016 and an approach to the hip in the interval between the inferior gemellus and quadratus femoris can be used for both hemi- and total hip arthroplasty. The HemiSPAIRE technique in hip hemiarthroplasty for displaced intracapsular fractures has been compared with the standard lateral approach (advocated by NICE) in a pragmatic, superiority, multicentre, randomised controlled trial into postoperative mobility and function. This NIHR funded study was recruited between November 2019 and April 2022 and the results are reported in this presentation. The author has used the SPAIRE technique in 1026 routine primary total hip replacements since February 2016. The technique is described along with results from NJR data. SPAIRE is most challenging in patients with small anatomy, reduced offset, with an external rotation deformity. Particularly in these, but in all cases, MAKO robotic assistance facilitates accurate implantation of prostheses and precise recreation of biomechanics. The MAKO robot has been used in all cases since 2018 and SPAIRE/MAKO is now the standard of care in the author's practice. To evaluate whether robotic-assisted tendon-sparing posterior approaches (piriformis sparing and SPAIRE), improve patient outcomes in total hip arthroplasty compared with a robotic-assisted standard posterior approach, the NIHR Efficacy and Mechanism Evaluation Programme has recently funded the HIPSTER trial (HIP Surgical Techniques to Enhance Rehabilitation). This is a single-centre, double-blinded, parallel three-arm, randomised, controlled, superiority trial; recruitment is in progress. The greatest value of robotic assistance may be when it is used in combination with tendon-sparing surgery. Data is being gathered to evaluate whether the SPAIRE/MAKO technique confers benefits with regard the speed of post-op mobilisation as well as accelerated return to unrestricted function


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 73 - 73
19 Aug 2024
Ganz R Blümel S Stadelmann VA Leunig M
Full Access

The Bernese periacetabular osteotomy (PAO) is not indicated for growing hips as it crosses the triradiate cartilage in its posterior branch, and experimental work has shown this can induce substantial deformations, similar to posttraumatic dysplasia, which is observed after pelvis crash injuries in childhood. Upon examination, all injuries in the 19 cases of posttraumatic dysplasia described in literature plus 16 hips of our personal collection took place before the age of 6, which is striking as pelvic injuries in children increase with age. Based on this observation, we started to extend the PAO indication to severe dysplasias in children with open growth plate, initially aged 9 years and older. Following the positive results, it was extended further, our youngest patient being 5 years old. We retrospectively examined radiographic outcomes of 23 hips (20 patients), aged 10.6±1.8 years [range 5.0 – 13.2], operated by us in four centers. Pre- and 3-months postoperative, and the latest FUP radiograph at growth plate closure were measured. We evaluated the acetabular index (AI), lateral center-edge (LCE), ACM-value and compared them with reference values adjusted for age. The age at triradiate cartilage closure was compared with the non-operated side. The follow-up time was 5.4±3.7 years [0.8 - 12.7]. In 5 hips, growth plate closure was delayed by a few months. All angles significantly normalized after PAO (LCE: 14±8° → 38±11°, AI: 20±8° → 7±4°, ACM: 53±5° → 48±4°), with >80% of them severe pathological pre-PAO, none afterwards. Acetabular molding was normal. Only few complications occurred; one had signs of coxarthosis, one sciatic nerve pain, one interfering osteosynthesis material that was removed, one had an additional valgus osteotomy, and all resolved. Based on 20 cases with follow-up until complete triradiate cartilage closure, we believe to have sufficient information to extend the PAO indication to growing hips of 9 years and older


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 32 - 32
19 Aug 2024
Caplash G Caplash Y Copson D Thewlis D Ehrlich A Solomon LB Ramasamy B
Full Access

Few surgical techniques to reconstruct the abductor mechanism of the hip have been reported, with outcomes reported only from case reports and small case series from the centres that described the techniques. As in many of our revision THA patients the gluteus maximus was affected by previous repeat posterior approaches, we opted to reconstruct the abductor mechanism using a vastus lateralis to gluteus medius transfer. We report the results of such reconstructions in seven patients, mean age 66 (range, 53–77), five females, presenting with severe abductor deficiency (MRC grade 1–2). Five patients had previous revision THA, two with a proximal femoral replacement, one patient had a primary THA after a failed malunited trochanteric fracture, and one patient had a native hip with idiopathic fatty infiltration of glutei of >90%. All patients had instrumented gait analysis, and surface electromyography (EMG) of the glutei, TFL, and vastus muscles simultaneously before surgery and at each post-op follow-up. Postoperatively, patients were allowed to weight bear as tolerated and were requested to wear an abduction brace for the first six weeks after surgery to protect the transfer. All patients improved after surgery and reached an abductor power of 3 or more. All patients walked without support six months after surgery and were satisfied with the result. Abductor function continued to improve beyond one year of follow-up, and some patients reached an abductor power of 5. EMG demonstrated that the transferred vastus lateralis started firing synchronously with gluteus medius after three months post-surgery, suggesting adaptation to its new function. No knee extension weakness was recorded. One patient complained of lateral thigh numbness and was dissatisfied with the cosmetic look of her thigh after surgery. Our preliminary results are encouraging and comparable with those achieved by the originators of the technique


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 29 - 29
19 Aug 2024
Kayani B Konan S Tahmassebi J Giebaly D Haddad FS
Full Access

The direct superior approach (DSA) is a modification of the posterior approach (PA) that preserves the iliotibial band and short external rotators except for the piriformis or conjoined tendon during total hip arthroplasty (THA). The objective of this study was to compare postoperative pain, early functional rehabilitation, functional outcomes, implant positioning, implant migration, and complications in patients undergoing the DSA versus PA for THA. This study included 80 patients with symptomatic hip arthritis undergoing primary THA. Patients were prospectively randomised to receive either the DSA or PA for THA, surgery was undertaken using identical implant designs in both groups, and all patients received a standardized postoperative rehabilitation programme. Predefined study outcomes were recorded by blinded observers at regular intervals for two-years after THA. Radiosteriometric analysis (RSA) was used to assess implant migration. There were no statistical differences between the DSA and PA in postoperative pain scores (p=0.312), opiate analgesia consumption (p=0.067), and time to hospital discharge (p=0.416). At two years follow-up, both groups had comparable Oxford hip scores (p=0.476); Harris hip scores (p=0.293); Hip disability and osteoarthritis outcome scores (p=0.543); University of California at Los Angeles scores (p=0.609); Western Ontario and McMaster Universities Arthritis Index (p=0.833); and European Quality of Life questionnaire with 5 dimensions scores (p=0.418). Radiographic analysis revealed no difference between the two treatment groups for overall accuracy of acetabular cup positioning (p=0.687) and femoral stem alignment (p=0.564). RSA revealed no difference in femoral component migration (p=0.145) between the groups at two years follow-up. There were no differences between patients undergoing the DSA versus PA for THA with respect to postoperative pain scores, functional rehabilitation, patient-reported outcome measurements, accuracy of implant positioning, and implant migration at two years follow-up. Both treatment groups had excellent outcomes that remained comparable at all follow-up intervals


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 93 - 93
19 Aug 2024
Schaffler BC Robin JX Katzman JL Manjunath A Davidovitch R Rozell JC Schwarzkopf R
Full Access

The purpose of this study was to assess the variability in implant position between sides in patients who underwent staged, bilateral THA and whether variation from one side to the other affected patient-reported outcomes. A retrospective review was conducted on 207 patients who underwent staged, bilateral THA by the same surgeon from 2017–2022. Leg length, acetabular height, cup version, and coronal and sagittal stem angles were assessed radiographically and compared to the contralateral THA. Surgical approach and technology utilization were further assessed for their impact on variability. Linear regression was used to model the relationship between side-to-side variability and patient-reported outcome measures (PROMS). Between sides, mean radiographic leg length varied by 4.6mm (0.0–21.2), acetabular height varied by 3.3mm (0.0–13.7), anteversion varied by 8.2° (0.0 to 28.7), coronal stem alignment varied by 1.1° (0.0 to 6.9), and sagittal angulation varied by 2.3° (0.0 to 10.5). The anterior approach resulted in more variability in stem angle position in both the coronal (1.3° vs. 1.0°, p=0.036) and sagittal planes (2.8° vs. 2.0° p=0.012) compared to the posterior approach. The posterior approach generally led to more anteversion than the anterior approach. Use of robotics or navigation for acetabular positioning did not increase side-to-side variability in cup-related position or leg length. Despite considerable side-to-side variability, Hip dysfunction and osteoarthritis outcome scores (HOOS JR) were not affected by higher levels of position inconsistency. Staged, bilateral THA results in considerable variability in component position between sides. The anterior approach leads to more side-to-side variability in sagittal stem angle and cup anteversion than the posterior approach. Navigation and robotics do not improve the consistency of component position in bilateral THA. Variation in implant position was not associated with differences in PROMs, suggesting that despite variability, patients can tolerate these differences between sides


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 52 - 52
19 Aug 2024
Malhotra R Parameswaran A Gautam D Batra S Apsingi S Kishore V Eachempati KK
Full Access

Chronic pelvic discontinuity (CPD) during revision hip arthroplasty is a challenging entity to address. The aim of this study was to evaluate the clinical and radiologic outcomes, and complications of the “acetabular distraction technique” for the management of CPD during revision hip arthroplasty. Patients with CPD, who underwent acetabular revision between 2014 and 2022 at two tertiary care centres, using an identical distraction technique, were evaluated. Demographic parameters, pre-operative acetabular bone loss, duration of follow-up, clinical and radiologic outcomes, and survivorship were evaluated. In all, 46 patients with a mean follow-up of 34.4 (SD=19.6, range: 24–120) months were available for evaluation. There were 25 (54.3%) male, and 21 (45.7%) female patients, with a mean age of 58.1 (SD=10.5, range: 40–81) years at the time of revision surgery. Based on the Paprosky classification of acetabular bone loss, 19 (41.3%), 12 (26.1%), and 15 (32.6%) patients had type 3b, 3a, and 2c defects. All patients were managed using the Trabecular Metal™ Acetabular Revision System; 16 patients required additional Trabecular Metal™ augments. The mean HHS improved from 50.1 (SD=7.6, range: 34.3 – 59.8) pre-operatively, to 86.6 (SD=4.2, range: 74.8 -91.8) at the last follow-up. Two patients (4.3 %) developed partial sciatic nerve palsy, two (4.3%) had posterior dislocation, and one (2.2%) required re-revision for aseptic loosening. Radiologically, 36 (78.3%) patients showed healing of the pelvic discontinuity. The Kaplan-Meier construct survivorship was 97.78% when using re-revision for aseptic acetabular loosening as an endpoint. The acetabular distraction technique has good clinical and radiologic outcomes in the management of CPD during revision hip arthroplasty


Traditional mechanical debridement can only remove visibly infected tissue and is unable to completely clear all the biofilm that hides within muscle crevices and nerves. This study aims to determine the results of single-stage revision using noncontact low frequency ultrasonic debridement in treating chronic periprosthetic joint infections (PJI). A prospective study of consecutive patients requiring single-stage revision for chronic PJI was performed since August 2021. After mechanical debridement, an 8‑mm handheld non‑contact low‑frequency ultrasound probe was used for ultrasonic debridement at a frequency of (25±5) kHz and power of 90% for 5 minutes. Each ultrasound lasted 10 seconds with 3‑seconds intervals. The probe was repeatedly sonicated among all soft tissue and bsingle interface. The distal femoral canal and the posterior capsule of the knee were fully sonicated with a special right‑angle probe. Chemical debridement was then performed to irrigation the whole operative area. Recurrence of infection, culture results and number of colonies 24 hours after ultrasonic debridement were recorded. A total of 45 patients (25 hips and 20 knees) were included and 43 of them (95.6%) were free of infection at a mean follow-up time of 29 months (24 to 33). There were no intraoperative complications related to ultrasonic debridement (neurovascular and muscle injury, poor wound healing and fat liquefaction). The culture‑positive rate of wound liquid before ultrasonic debridement was 40.0% (18/45), which significantly increased to 75.6% (34/45) after ultrasonic debridement (P=0.001). The median number of colonies 24 hours after ultrasonic debridement was 2372 CFU/ml (310 to 4340 CFU/ml), which was significantly higher than that before debridement (307 CFU/ml; 10 to 980 CFU/ml) (P=0.000). Single-stage revision with non‑contact low‑frequency ultrasonic debridement can fully expose bacteria within biofilm, increase the efficacy of chemical debridement and lead to a favorable short‑term outcome without related complications


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 8 - 8
19 Aug 2024
Kärrholm J Itayem R Angelomenos V Mohaddes M Rogmark C Rolfson O
Full Access

In 2022, approximately 60% of inserted cups and stems in Sweden utilized cemented fixation. Two predominant brands, Refobacin Bone Cement R and Palacos R+G, both incorporating gentamicin, were employed in over 90% of primary cemented Total Hip Arthroplasties (THAs) between 2012 and 2022. This study investigates whether the choice between these cement types affects the risk of revision. The five most frequently used cemented cups and the three most common stems were studied. Inclusion criteria encompassed hips with non-tumour diagnoses, operated through a direct lateral or posterior incision, featuring a 28–36 mm metal or ceramic head. Outcomes were assessed for cup revisions (n=55,457 Refobacin, 37,210 Palacos), stem revisions (n=51,732 Refobacin, 30,018 Palacos), and all-cemented THAs with either brand (n=45,265 Refobacin, 26,347 Palacos). Kaplan-Meier life tables and hazard ratios (HR) utilizing Cox regression were computed, adjusting for age, sex, diagnosis, implant type, femoral head size, and material. Over a 10-year period, the cumulative percent revision with Refobacin was consistently higher than Palacos in all three analyses (cups: Refobacin 2.4 (2.3–2.5), Palacos 2.1 (2.0–2.2); stems: Refobacin 2.6 (2.5–2.7), Palacos 2.1 (2,0–2,2); all-cemented: Refobacin 3.2 (2.9–3.5), Palacos 2.9 (2.6–3.2)). Both unadjusted and adjusted HR were 13–25% lower with Palacos. In the analysis of all-cemented THAs, the adjusted HR for Palacos was 0.85 (0.76–0.95). Separating revisions into infectious and non-infectious reasons revealed a lower risk of infectious revisions with Palacos in all three analyses (all-cemented: adjusted HR infection 0.66 (0.56–0.78); non-infectious 1.10 (0.94–1.28)). Hips cemented with Refobacin may face an increased risk of infection, potentially due to a smaller release of antibiotics into surrounding tissues. Unaccounted factors like different mixing systems or unknown biases could also influence outcomes, emphasizing the need for further investigation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 41 - 41
19 Aug 2024
Cobb J Maslivec A Clarke S Halewood C Wozencroft R
Full Access

A ceramic-on-ceramic hip resurfacing implant (cHRA) was developed and introduced in an MHRA-approved clinical investigation to provide a non metallic alternative hip resurfacing product. This study aimed to examine function and physical activity levels of patients with a cHRA implant using subjective and objective measures both before and 12 months following surgery in comparison with age and gender matched healthy controls. Eighty-two unilateral cHRA patients consented to this study as part of a larger prospective, non-randomised, clinical investigation. In addition to their patient reported outcome measures (PROMs), self- reported measures of physical activity levels and gait analysis were undertaken both pre- operatively (1.5 weeks) and post operatively (52 weeks). This data was then compared to data from a group of 43 age gender and BMI matched group of healthy controls. Kinetics and kinematics were recorded using an instrumented treadmill and 3D Motion Capture. Statistical parametric mapping was used for analysis. cHRA improved the median Harris Hip Score from 63 to 100, Oxford Hip score from 27 to 48 and the MET from 5.7 to 10.3. cHRA improved top walking speed (5.75km vs 7.27km/hr), achieved a more symmetrical ground reaction force profile, (Symmetry Index value: 10.6% vs 0.9%) and increased hip range of motion (ROM) (31.7° vs 45.9°). Postoperative data was not statistically distinguishable from the healthy controls in any domain. This gait study sought to document the function of a novel ceramic hip resurfacing, using those features of gait commonly used to describe the shortcomings of hip arthroplasty. These features were captured before and 12 months following surgery. Preoperatively the gait patterns were typical for OA patients, while at 1 year postoperatively, this selected group of patients had gait patterns that were hard to distinguish from healthy controls despite an extended posterior approach. Applications for regulatory approval have been submitted


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 27 - 27
19 Aug 2024
Solomon M Plaskos C Pierrepont J
Full Access

The purpose of this study was to investigate the influence of surgical approach on femoral stem version in THA. This was a retrospective database review of 830 THAs in 830 patients that had both preoperative and postoperative CT scans. All patients underwent staged bilateral THAs and received CT-based 3D planning on both sides. Stem version was measured in the second CT-scan and compared to the native neck axis measured in the first CT-scan, using the posterior condyles as the reference for both. Cases were performed by 104 surgeons using either a direct anterior (DAA, n=303) or posterior (PA, n=527) approach and one of four stem designs: quadrangular taper, calcar-guided short stem, flat taper and fit-and-fill. Sub-analyses investigated changes in version for low (≤5°), neutral (5–25°) and high (≥25°) native version subgroups and for the different implant types. Native version was not different between approaches (DAA = 12.6°, PA = 13.6°, p = 0.16). Overall, DAA stems were more anteverted relative to the native neck axis vs PA stems (5.9° vs 1.4°, p<0.001). This trend persisted in hips with high native version (3.2° vs -5.3°, p<0.01) and neutral native version (5.3° vs 1.3°, p<0.001), but did not reach significance in the low native version subgroup (8.9° vs 5.9°, p=0.13). Quadrangular taper, calcar-guided, and flat taper stem types had significantly more anteversion than native for DAA, while no differences were found for PA. Stems implanted with a direct anterior approach had more anteversion than those implanted with a posterior approach. The smaller surgical field, soft tissue tension and lack of a “tibial” vertical reference frame may contribute to this finding


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 57 - 57
19 Aug 2024
Jones SA Davies O
Full Access

Dislocation following revision THA remains a leading cause of failure. Integrity of the abductor muscles is a major contributor to stability. Large diameter heads (LDH), Dual Mobility (DM) and Constrained Acetabular Liners (CAL) are enhanced stability options but the indication for these choices remains unclear. We assessed an algorithm based on Gluteus Medius (GM) deficiency to determine bearing selection. Default choice with no GM damage was a LDH. GM deficiency with posterior muscle intact received DM and CAL for GM complete deficiency with loss of posterior muscle. Consecutive revision THA series followed to determine dislocation, all-cause re-revision and Oxford Hip Score (OHS). 311 revision THA with mean age 70 years (32–95). At a mean follow-up of 4.8 years overall dislocation rate 4.1% (95%CI 2.4–7.0) and survivorship free of re-revision 94.2% (95%CI 96.3–91.0). Outcomes:. Group 1 - LDH (36 & 40mm) n=164 / 4 dislocations / 7 re-revisions. Group 2 - DM n=73 / 3 dislocations / 4 re-revisions. Group 3 - CAL n=58 / 5 dislocations / 7 re-revisions. Group 4 - Other (28 & 32mm) n=16 / 1 dislocation / no re-revisions. Mean pre-op OHS: 19.6 (2–47) and mean post-op OHS: 33.9 (4–48). Kaplan-Meier analysis at 60 months dislocation-free survival was 96.1% (95% CI: 93.0–97.8). There was no difference between survival distributions comparing bearing choice (p=0.46). Decision making tools to guide selection are limited and in addition soft tissue deficiency has been poorly defined. The posterior vertical fibres of GM have the greatest lateral stabiliser effect on the hip. The algorithm we have used clearly defined indication & implant selection. We believe our outcomes support the use of an enhanced stability bearing selection algorithm


Bone & Joint Open
Vol. 5, Issue 8 | Pages 681 - 687
19 Aug 2024
van de Graaf VA Shen TS Wood JA Chen DB MacDessi SJ

Aims. Sagittal plane imbalance (SPI), or asymmetry between extension and flexion gaps, is an important issue in total knee arthroplasty (TKA). The purpose of this study was to compare SPI between kinematic alignment (KA), mechanical alignment (MA), and functional alignment (FA) strategies. Methods. In 137 robotic-assisted TKAs, extension and flexion stressed gap laxities and bone resections were measured. The primary outcome was the proportion and magnitude of medial and lateral SPI (gap differential > 2.0 mm) for KA, MA, and FA. Secondary outcomes were the proportion of knees with severe (> 4.0 mm) SPI, and resection thicknesses for each technique, with KA as reference. Results. FA showed significantly lower rates of medial and lateral SPI (2.9% and 2.2%) compared to KA (45.3%; p < 0.001, and 25.5%; p < 0.001) and compared to MA (52.6%; p < 0.001 and 29.9%; p < 0.001). There was no difference in medial and lateral SPI between KA and MA (p = 0.228 and p = 0.417, respectively). FA showed significantly lower rates of severe medial and lateral SPI (0 and 0%) compared to KA (8.0%; p < 0.001 and 7.3%; p = 0.001) and compared to MA (10.2%; p < 0.001 and 4.4%; p = 0.013). There was no difference in severe medial and lateral SPI between KA and MA (p = 0.527 and p = 0.307, respectively). MA resulted in thinner resections than KA in medial extension (mean difference (MD) 1.4 mm, SD 1.9; p < 0.001), medial flexion (MD 1.5 mm, SD 1.8; p < 0.001), and lateral extension (MD 1.1 mm, SD 1.9; p < 0.001). FA resulted in thinner resections than KA in medial extension (MD 1.6 mm, SD 1.4; p < 0.001) and lateral extension (MD 2.0 mm, SD 1.6; p < 0.001), but in thicker medial flexion resections (MD 0.8 mm, SD 1.4; p < 0.001). Conclusion. Mechanical and kinematic alignment (measured resection techniques) result in high rates of SPI. Pre-resection angular and translational adjustments with functional alignment, with typically smaller distal than posterior femoral resection, address this issue. Cite this article: Bone Jt Open 2024;5(8):681–687


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 15 - 15
19 Aug 2024
Argenson J Peuchot H Simmons EH Fabre-Aubrespy M Jacquet C Flecher X
Full Access

Dislocation after Total Hip Arthroplasty (THA) is a frequent cause of revision and patients with intrinsic risk factors have been identified. The use of dual mobility (DM) cup has shown great efficiency in preventing dislocation, with questions regarding selective or absolute use. The aim of this study was to compare the outcome of single mobility THA (SM-THA) and DM-THA, when used for selected patients. This retrospective continuous cohort study evaluated 490 patients of whom 275 received SM-THA and 215 received DM-THA. There were 304 primary osteoarthritis (62%), 121 femoral neck fractures (24%) and 65 other indications (14%). The surgical approach was anterior (AA) in 79% and posterior (PA) in 21% of cases. In the DM-THA group, 189 patients (87%) presented at least one dislocation risk factor compared to 128 patients (46%) in the SM-THA group. The primary outcome was revision for all causes, with or without implant removal. Secondary outcomes included length of hospital stay. There was no difference in all cause revision at two years follow up with 9 procedures (3.2%) in SM-THA group and 11 in DM-THA group (5.1%) (p=0.3). There were 3 dislocations in SM-THA group (3 AA) and 3 in DM-THA group (2 PA and 1 AA) (p=0.4). The length of stay was significantly longer in DM-THA group with 7 days (2–12) compared to 4 days (1–7) in SM-THA group (p=0.001). SM-THA and DM-THA are two complementary devices in the management of patients requiring primary THA. SM-THA is a safe option for patients without dislocation risk factors, especially when using AA. The identification of such factors is important to select patients requiring DM-THA and provide reproducible outcomes in a University Hospital practice including various levels of surgeon experience


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 77 - 77
19 Aug 2024
Fu H Singh G H C Lam J Yan CH Cheung A Chan PK Chiu KY
Full Access

Hip precautions following total hip arthroplasty (THA) limits flexion, adduction and internal rotation, yet these precautions cause unnecessary psychological stress. This study aims to assess bony and implant impingement using virtual models from actual patient's bony morphology and spinopelvic parameters to deduce whether hip precautions are necessary with precise implant positioning in the Asian population. Individualized sitting and standing sacral slope data of robotic THAs performed at two tertiary referral centers in Hong Kong was inputted into the simulation system based on patients’ pre-operative sitting and standing lumbar spine X-rays. Three-dimensional dynamic models were reconstructed using the Stryker Mako THA 4.0 software to assess bony and implant impingement both anteriorly and posteriorly, with default cup placement at 40° inclination and 20° anteversion. Femoral anteversion followed individual patient's native version. A 36mm hip ball was chosen for all cups equal or above 48mm and 32mm for those below. Anterior impingement was assessed by hip flexion and posterior impingement was assessed by hip extension. 113 patients were included. At neutral rotation and adduction, no patients had anterior implant impingement at hip flexion of 100°. 1.7% had impingement at 110°, 3.5% had impingement at 120°, 9.7% had impingement at 130°. With 20° of internal rotation and adduction, 0.8% had anterior implant impingement at hip flexion of 90°, 7.1% had impingement at 100° and 18.5% had impingement at 110°. With the hip externally rotated by 20°, 0.8% of patients had posterior implant impingement, and 8.8% bony impingement at 0° extension. With enabling technology allowing accurate component positioning, hip precautions without limiting forward flexion in neutral position is safe given precise implant positioning and adequate osteophyte removal. Patients should only be cautioned about combined internal rotation, adduction with flexion


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 47 - 47
19 Aug 2024
Dimitriou D Almazrua I Alhasson M Staunton P Zukor D Huk O Antoniou J
Full Access

Short stems have been developed to conserve bone stock, especially in younger populations undergoing a total hip arthroplasty (THA), and showed similar functional outcomes compared to conventional stems. Recent literature suggested that stem length might be an independent risk factor for acute periprosthetic femoral fracture in direct anterior THA (1) or with different short stem designs (2). The purpose of the present study was to compare the incidence of acute periprosthetic femoral fractures, between stems of the same manufacture (Taperloc microplasty vs Taperloc complete), which have the same stem characteristics, except for the stem length which is 35 mm shorter in Taperloc microplasty during posterior and lateral THA. Our institution's arthroplasty database was searched for all primary total hip arthroplasties utilizing short femoral stems performed between August 2016 and August 2023. Pre-operative X-rays for each case were analysed to characterize the proximal femoral geometry, specifically the canal bone ratio (CBR) and canal flare index (CFI). Data analysis was performed to identify risk factors for periprosthetic fractures. For the time period assessed, 2107 femoral stems (Taperloc Microplasty:1727, Taperloc complete: 380) were implanted. Females constituted 53% of the cohort. The average patient age was 70±11 years. The periprosthetic fracture rate was 0.94%, with 20 periprosthetic fractures (Taperloc Microplasty:17, Taperloc complete: 3) excluding 2 greater trochanteric fractures (1 at each group), identified at follow-up of three months. There was no significant difference between the periprosthetic fracture rates between the two stems (0.98% vs 0.79%, p>0.72) The multivariate regression analysis demonstrated that the stem length, CBR, CFI, age, and gender were not risk factors for periprosthetic fracture. The present study demonstrated that both Taperloc Microplasty and Taperloc complete stems had similar rates of periprosthetic fractures, and the stem length was not a risk factor for a periprosthetic fracture during uncemented THA. 1. Tamaki T, Cementless Tapered-Wedge Stem Length Affects the Risk of Periprosthetic Femoral Fractures in Direct Anterior Total Hip Arthroplasty. J Arthroplasty. 2018 Mar;33(3):805-809. 2. Staunton P. Acute Periprosthetic Hip Fracture with Short Uncemented Femoral Stems. J Arthroplasty 2024 accepted


The Paprosky acetabular bone defect classification system and related algorithms for acetabular reconstruction cannot properly guide cementless acetabular reconstruction in the presence of porous metal augments. We aimed to introduce a rim, points, and column (RPC)-oriented cementless acetabular reconstruction algorithm and its clinical and radiographic outcomes. A total of 123 patients (128 hips) were enrolled. A minimum 5-year radiographic follow-up was available for 96 (75.8%) hips. The mean clinical and radiographic follow-up durations were 6.8±0.9 (range: 5.2–9.2) and 6.3±1.9 (range: 5.0–9.2) years, respectively. Harris hip score (HHS) improved significantly from 35.39±9.91 preoperatively to 85.98±12.81 postoperatively (P<0.001). Among the fixation modes, 42 (32.8%) hips were reconstructed with rim fixation, 42 (32.8%) with three-point fixation without point reconstruction, 40 (31.3%) with three-point fixation combined with point reconstruction, and 4 (3.1%) with three-point fixation combined with pelvic distraction. Complementary medial wall reconstruction was performed in 20 (15.6%) patients. All acetabular components were radiographically stable. Nine-year cumulative Kaplan–Meier survival rates for 123 patients with the endpoint defined as periprosthetic joint infection, any reoperation, and dissatisfaction were 96.91% (confidence interval [CI]: 86.26%, 99.34%), 97.66% (CI: 92.91%, 99.24%), and 96.06% (CI: 86.4%, 98.89%), respectively. Cup stability in cementless acetabular reconstruction depends on rim or three-point fixation. The continuity of the anterior and posterior columns determines whether the points provide adequate stability to the cup. Medial wall reconstruction is an important complementary fixation method for rim or three-point fixation. The patients who underwent cementless acetabular reconstruction guided by the RPC decision-making algorithm demonstrated satisfactory mid-term clinical function, satisfaction levels, radiographic results, and complication rates


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 35 - 35
19 Aug 2024
Zhang Z Luo D Cheng H Ren N li Y Zhang J Zhang H
Full Access

Osteonecrosis of the femoral head after femoral neck fracture (ONFHpoFNFx) poses challenges in children, particularly at Ficat III stage. Limited effective treatments are available. This study explores basicervical femoral neck rotational osteotomy (BFNRO) for ONFHpoFNFx in children and adolescents and evaluates its outcomes. Children and adolescents with ONFHpoFNFx (Ficat stage III) underwent BFNRO at our center from June 2017 to September 2022 were included. Follow-up exceeded 1 year, with data on modified-Harris-hip-score (mHHS), range of motion (ROM), patient satisfaction, femoral head collapse, necrotic area repair, leg-length, and osteoarthritis progression recorded. This study included 15 cases (15 hips), with 8 males and 7 females, averaging 12.9 years in age (range: 10–17 years). Nine cases had BFNRO alone, and six had combined PAO. Rotation angles varied from 70° to 90° for anterior rotation and 110° to 135° for posterior rotation. Nine patients had femoral neck fixation in a varus position (10° to 30°). The postoperative contour of the weight-bearing area of the femoral head has significantly improved in all patients. With an average follow-up of 28.6 months (range: 12.2–72.7 months), mHHS significantly improved (65.2 to 90.2, P<0.001). Only one patient showed femoral head collapse. Patients experienced no/mild hip pain (VAS=0-3), slight restriction in range of motion, and mild limb shortening. Two patients showed osteoarthritis progression. No infections, joint replacements, or nerve injuries were observed. Even in cases of ONFHpoFNFx in the late stage, BFNRO in children and adolescents can still yield positive early to mid-term results by relocating the necrotic area and restoring the integrity of the anterior-lateral column of the femoral head, thereby preventing femoral head collapse and delaying the onset of severe osteoarthritis


Bone & Joint Open
Vol. 5, Issue 8 | Pages 671 - 680
14 Aug 2024
Fontalis A Zhao B Putzeys P Mancino F Zhang S Vanspauwen T Glod F Plastow R Mazomenos E Haddad FS

Aims

Precise implant positioning, tailored to individual spinopelvic biomechanics and phenotype, is paramount for stability in total hip arthroplasty (THA). Despite a few studies on instability prediction, there is a notable gap in research utilizing artificial intelligence (AI). The objective of our pilot study was to evaluate the feasibility of developing an AI algorithm tailored to individual spinopelvic mechanics and patient phenotype for predicting impingement.

Methods

This international, multicentre prospective cohort study across two centres encompassed 157 adults undergoing primary robotic arm-assisted THA. Impingement during specific flexion and extension stances was identified using the virtual range of motion (ROM) tool of the robotic software. The primary AI model, the Light Gradient-Boosting Machine (LGBM), used tabular data to predict impingement presence, direction (flexion or extension), and type. A secondary model integrating tabular data with plain anteroposterior pelvis radiographs was evaluated to assess for any potential enhancement in prediction accuracy.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 662 - 670
9 Aug 2024
Tanaka T Sasaki M Katayanagi J Hirakawa A Fushimi K Yoshii T Jinno T Inose H

Aims

The escalating demand for medical resources to address spinal diseases as society ages is an issue that requires careful evaluation. However, few studies have examined trends in spinal surgery, especially unscheduled hospitalizations or surgeries performed after hours, through large databases. Our study aimed to determine national trends in the number of spine surgeries in Japan. We also aimed to identify trends in after-hours surgeries and unscheduled hospitalizations and their impact on complications and costs.

Methods

We retrospectively investigated data extracted from the Diagnosis Procedure Combination database, a representative inpatient database in Japan. The data from April 2010 to March 2020 were used for this study. We included all patients who had undergone any combination of laminectomy, laminoplasty, discectomy, and/or spinal arthrodesis.