Advertisement for orthosearch.org.uk
Results 1 - 20 of 740
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 48 - 48
19 Aug 2024
Falez F Casella F Zaccagno S
Full Access

Post-operative peri-prosthetic femoral fracture (PO-PPFF) is one of the most relevant complications in primary Total Hip Arthroplasty (pTHA), accountable for a significant clinical and socio-economic burden both in revision and fixation settings. We retrospectively reviewed of our series of 1586 cementless total hip arthroplasty performed between 1999 and 2019 (achieving a minimum of 5-years follow-up) with different short stems. We have observed a cumulative low incidence of PO-PPFF of 0,33% (5 cases): we divided Po-PPFF in two groups: fracture occurred around a short stem (A) and around a standard shortened stem (B), according to French Hip & Knee Classification of Short Stems. Despite the length of observed period (mean follow-up 12 years, min 5 years max 24 years) a total of 1512 cases (mean age at surgery 61 years, max 74, min 40 years) were available to clinical and radiographic follow-up, being this population enrolled in elective surgery clinical protocols. Our data exceed the low incidence of post-operative femoral fracture around bone -preserving previously reported by Kim in 2018 (12 fracture out of 1089 cases:1.1%). No correlation have been observed among occurrence of PO-PPF age of the patient and no fracture occurred around cemented short stems despite patient's characteristics were unfavourable in term of age and bone quality. This result is not unexpected, giving the lower incidence of peri-prosthetic fracture even cemented conventional stems, as reported in all registry and systematic reviews. A similar behaviour was reported in 2020 Australian Joint Registry, where Post-operative periprosthetic femoral fracture showed a steep curve in early period, but remaining firmly below 1% during the following 12 years. Our clinical data seems to confirm previous studies by Jones (conducted on synthetic bone and fresh-frozen cadaveric femurs) where higher fracture angles and higher fracture torque were detected in short hips compared to standard stems


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 5 - 5
19 Aug 2024
Gevers M Vandeputte F Welters H Corten K
Full Access

High doses of intra-articular (IA) antibiotics has been shown to effectively achieve a minimal biofilm eradication concentration which could mitigate the need for removal of infected but well-ingrown cementless components of a total hip arthroplasty (THA). However, there are concerns that percutaneous catheters could lead to multi-resistance or multi-organism peri-prosthetic joint infections (PJI) following single stage THA revisions for PJI. Eighteen single-stage revision procedures were performed for acute (N=9) or chronic (N=9) PJI following a primary (N=12) or revision (N=6) cementless THA. Modular and loosened components were replaced. All well ingrown components were retained. Two Hickmann catheters were placed in the joint space. Along with intravenous antibiotics, IA antibiotics were injected twice a day for two weeks, followed by 3 months of oral antibiotics. Per-operative cultures demonstrated 4 multi-bacterial PJIs. None of the patients developed post-operatively an AB related renal or systemic dysfunction. At a mean follow-up of 38 months [range, 8–72] all patients had normal erythrocyte sedimentation rate and white blood cell count. Four had a slightly elevated C-reactive protein but were completely symptom free and did not show any sign of loosening at a mean of 27 months [range, 16–59]. Addition of high doses of IA antibiotics following single-stage revision for PJI in cementless THA, is an effective and safe treatment option that allows for retention of well-ingrown components. We found no evidence for residual implant infection or catheter induced multi-resistance. Total hip arthroplasty, revision surgery, Periprosthetic Joint Infection, Intra-articular antibiotics. Level 4 (Case series)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 31 - 31
2 May 2024
Stedman T Hatfield T McWilliams A
Full Access

Arthroplasty in patients who are intravenous drug abusers presents a complex challenge, frequently requiring intervention at a younger age. The cohort suffer increased complication rates due to significant co-morbidities and poor engagement in medical services, in comparison to other patients undergoing lower limb arthroplasty. Multiple small studies show arthroplasty in this patient cohort is associated with high complication and mortality rates. A search of electronic databases were undertaken with the assistance of the library services from the Rotherham NHS Foundation Trust, including Chocraine, SCOPUS and PubMed. Abstracts were reviewed and relevant studies extracted for full review. Full text articles were reviewed based on strict inclusion and exclusion criteria. Searches identified Two thousand and forty-four papers; twenty-seven studies were identified for full review of the paper based on the inclusion criteria above. From this, nine studies were deemed appropriate to for data extraction. These nine papers present one hundred and thirty-two cases of lower limb arthroplasty, fifty nine Total Knee Arthroplasty and seventy three Total Hip Arthroplasty. From this the authors examined incidences of implant failure due to infection, revision, mortality, dislocation, aseptic loosening, peri-prosthetic fracture, or other causes. Of these, 58% of patients (n = 77) with a history of intravenous drug abuse suffered some form of significant complication; 4% of this cohort (n = 5) were lost to follow up. Infection was reported in 32% of cases and a mortality rate of 4.7%. The rising demand of lower limb arthroplasty for intra-venous drug abusers presents a very real problem for the modern Orthopaedic surgeon. Within the studies examined, more than half report implant failure. This study synthesises the available literature regarding treatment of these patients to help facilitate decision making and informed consent


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 32 - 32
2 May 2024
Yan A Yan A Hoggett L Helm A
Full Access

The increased torque required to dislocate dual mobility (DM) components may increase peri-prosthetic femoral fracture (PPF) risk. Current literature often relies on revision as an endpoint and may underestimate PPF. This study aims to review PPF rate, risks and treatment following primary DM implantation. Prospective cohort study of 549 patients following primary DM total hip arthroplasty (THA) between 2013 and 2021. Collected data included demographics, indication for surgery, cortical index and PPF. 549 patients were identified with primary DM THA. Mean age was 73 years (26–96). 446 (81.2%) patients had their index surgery following hip fracture. 18 patients (3.27%) sustained a PPF. Cumulative PPF rate was 1.5% at 1-year, 2.2% at 5-years and 3.27% overall. PPF was higher in patients undergoing surgery following hip fracture (4%) vs. other indications (1%). OR 4.04 (95% CI:0.53, 30.72), p=0.219. Mean cortical index was lower in patients with PPF 0.4 (95% CI:0.36, 0.45) compared to those without 0.46 (95% CI:0.45, 0.46) p=0.029. Treatment for PPF included 10 (55.6%) open reduction internal fixation (ORIF), 7 (38.9%) revision THA and 1 conservatively managed. PPF rate following DM use is higher in our cohort than published rates. Our rates are comparable to some papers when subgroup analysis of older patients and cemented taper slip stems are considered. PPF risk with DM may be increased in patients undergoing surgery after hip fracture or with a lower cortical index preoperatively. Over half of PPF were managed with ORIF and may mask PPF risk studies that report using revision as an endpoint


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 11 - 11
23 Jan 2024
Raj S Magan A Jones SA
Full Access

Dual mobility (DM) is an established bearing option in Total Hip Arthroplasty (THA). The traditional mono-block DM designs have limited ability for additional fixation, whereas the modular DM designs allow additional screw fixation but limit internal diameter and have the potential to generate metal debris. We report the early results of a CoCrMo alloy mono-block implant manufactured by additive technology with a highly porous ingrowth surface to enhance primary fixation and osseointegration. Prospective follow-up of the Duplex. TM. implant first inserted in March 2016 enrolled into Beyond Compliance (BC). Primary outcome measure was all-cause revision and secondary outcomes dislocation, peri-prosthetic fracture (PPF) and Oxford Hip Score (OHS). Patients were risk stratified and all considered to be high risk for instability. Complications were identified via hospital records, clinical coding linkage using national database and via BC website. 159 implants in 154 patients with a mean age 74.0 years and a maximum F/U of 7 years. Survivorship for all-cause revision 99.4% (95% CI 96.2–99.8). One femoral only revision. Mean gain in OHS 27.4. Dislocation rate 0.6% with a single event. Patients with a cemented Polished taper stem (PTS) had a Type B PPF rate of 2.1% requiring revision/fixation. Compared to conventional THA this cohort was significantly older (74.0 vs 68.3 years), more co-morbidity (ASA 3 46.5% vs 14.4%) and more non-OA indications (32.4% vs 8.5%). Every patient had at least one risk factor for falling and >50% of cohort had 4 or more risk factors using NICE tool. We believe our results demonstrate that risk stratification successfully aids implant selection to prevent dislocation in high-risk patients. This novel design has provided excellent early results in a challenging cohort where individuals are very different to the “average” THA patient. NJR data on DM has reported an increase in revision for PPF. A “perfect storm” maybe created using DM in high-risk falls risk population. This re-enforces the need to consider all patient and implant factors when deciding bearing selection


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 27 - 27
17 Nov 2023
Arafa M Kalairajah Y Zaki E Habib M
Full Access

Abstract. Objective. Short-stem total hip arthroplasty (THA) aims to preserve the proximal bone stock for future revisions, so that the first revision should resemble a primary intervention rather than a revision. This study aimed to compare the clinical and radiological outcomes in revision THA after failed short stem versus after failed conventional stem THA. Methods. This study included forty-five patients with revision THA divided into three groups (15 each); group A: revision after short stem, group B: revision after conventional cementless stem and group C revision after conventional cemented stem. The studied groups were compared regarding 31 variables including demographic data, details of the primary and revision procedures, postoperative radiological subsidence, hospital stay, time for full weight bearing (FWB), preoperative and postoperative clinical scores. Results. Early stem subsidence (40%) was the main indication of revision in group A compared to peri-prosthetic femoral fractures (PFFs) (73.3%) and aseptic loosening (53.3%) in group B and C respectively (P=0.021). The mean time to revision was significantly shorter in group A (15 months) compared to 95.33 and 189.40 months in group B and C respectively. (P=0.005). Sixty % (9 patients) in group A were revised in the first year. The mean operative time, blood loss, postoperative blood transfusion and hospital stay were significantly lower in group A compared to group B and C (P<0.001, <0.001, 0.002 and 0.001 respectively). Revisions in group A were performed using either short stems (13.3%) or conventional stems (86.7%) whilst 80% of patients needed long stems and 20% of patients needed conventional stems in group B and C (P<0.001). The mean postoperative Harris Hip Score (HHS) at the latest follow up was 87.07, 87.53 and 85.47 in group A, B and C respectively. All PFFS had excellent results according to Beal's and Tower's criteria; all fractures healed and the implants were stable. Conclusion. The most common cause of failure of short stems is early stem subsidence. Short stem THA has specific indications and patient selection is very crucial. Preoperative templating for short stems and a detailed analysis of the individual patient anatomy in anteroposterior and lateral views are mandatory to predict the correct implant size more accurately. The use of intraoperative imaging can verify the sizing, implant position, and sufficient contact with the lateral cortex. Revision of short stem THA resembled the primary THA. If a standard implant can be used in a surgical revision instead of a longer revision stem, this can be considered as an advantage for the hip arthroplasty treatment concept. However, this only applies if the longevity of the first treatment with a short stem is comparable with that of a standard stem. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 12 - 12
23 Jun 2023
Yee AHF Chan VWK Chiu K
Full Access

Uncemented femoral components have been used in total hip arthroplasties (THAs) for over three decades. Data on long-term performance of hydroxyapatite-coated femoral stems is however limited. This study reports the survivorship of a collarless, straight, hydroxyapatite-coated femoral stem (Omnifit HA, Osteonic) with a minimum of 20 years of follow-up. We reviewed the results of 165 THAs using Omnifit HA in 138 patients performed between August 1993 and December 1999. The mean age at surgery was 46 years (range 20 – 77 years). Avascular necrosis was the most common cause of THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (range 20–31 years). At 20 and 25 years, 113 arthroplasties (91 patients) and 63 arthroplasties (55 patients) were available for follow-up respectively, while others had deceased or were lost to follow-up. Kaplan-Meier survivorship analysis was performed to evaluate the survival of the femoral component. Radiographs were reviewed at regular intervals, and implant stability was evaluated using Engh classification. Seven out of 165 stems were revised upon the latest follow-up; that included one case of aseptic loosening with revision done at 15 years, three peri-prosthetic fractures, two infections, and one recurrent dislocation. At 20 years, survivorship with revision of the femoral stem for any cause and aseptic loosening as the endpoint was 96.0% (95% CI, 92.6 – 99.5%) and 98.4% (95% CI, 96.2 – 100%) respectively. At 25 years, the corresponding survivorship rates were 94.5% (95% CI, 91.9 – 97.3%) and 98.1% (95% CI, 95.7 – 99.6%) respectively. Radiographic findings of stable bony fixation were seen in 86 stems (76.1%) and those of loosening in 4 stems (3.5%) at 20 years. All patients with radiographic signs of loosening were asymptomatic and did not require revision. The Omnifit HA femoral stem offered promising long-term survivorship into the third decade


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 1 - 1
23 Jun 2023
Parker J Horner M Jones SA
Full Access

Contemporary acetabular reconstruction in major acetabular bone loss often involves the use of porous metal augments, a cup-cage construct or custom implant. The aims of this study were: To determine the reproducibility of a reconstruction algorithm in major acetabular bone loss. To determine the subsequent success of reconstruction performed in terms of re-operation, all-cause revision and Oxford Hip Score (OHS) and to further define the indications for custom implants in major acetabular bone loss. Consecutive series of Paprosky Type III defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical cup. IIIB defects were planned to receive either augment and cup, cup-cage or custom implant. 105 procedures in cohort 100 patients (5 bilateral) with mean age 73 years (42–94). IIIA defects (50 cases) − 72.0% (95%CI 57.6–82.1) required a porous metal augment the remainder treated with a hemispherical cup alone. IIIB defects (55 cases) 71.7% (95%CI 57.6–82.1) required either augments or cup-cage. 20 patients required a hemispherical cup alone and 6 patients received a custom-made implant. Mean follow up of 7.6 years. 6 re-revisions were required (4 PJI, 2 peri-prosthetic fractures & 1 recurrent instability) with overall survivorship of 94.3% (95% CI 97.4–88.1) for all cause revision. Single event dislocations occurred in 3 other patients so overall dislocation rate 3.8%. Mean pre-op OHS 13.8 and mean follow-up OHS 29.8. Custom implants were used in: Mega-defects where AP diameter >80mm, complex discontinuity and massive bone loss in a small pelvis (i.e., unable to perform cup-cage). A reconstruction algorithm can >70% successfully predict revision construct which thereafter is durable with a low risk of re-operation. Jumbo cup utilized <1/3 of cases when morphology allowed. The use of custom implants has been well defined in this series and accounts for <5% of cases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 33 - 33
7 Jun 2023
Jones S Raj S Magan A
Full Access

Dual mobility (DM) is most often used by surgeons to reduce instability in high risk patients. NJR data on DM has not demonstrated a reduction in all cause revision and has reported an increase in revision for peri-prosthetic fracture (PPF). The aim of our study was:. Report outcome of DM used in high-risk patients including non-revision re-operations (dislocation & PPF). Comparison with conventional bearing THA (cTHA) with local, national and NJR benchmarking data. Retrospective cohort assessment of falls risk for patients receiving DM. Prospective F/U of a DM implant since 2016 and enrolled into Beyond Compliance (BC). Primary outcome measure all-cause revision with secondary outcome including any re-operation and Oxford Hip Score (OHS). All patients were risk stratified and considered high risk for instability. Complications were identified via hospital records, clinical coding linkage, NJR and BC. Benchmarking data for comparison was obtained from same data sources we also considered all B type PPF that occurred with cemented polished taper stem (PTS). 159 implants in 154 patients with a mean age 74.0 years and a maximum F/U of 6.7 years. Survivorship for all-cause revision 99.4% (95% CI 96.2–99.8). One femoral only revision. Mean gain in OHS 27.4. Dislocation rate 0.6% with a single event. Patients with a PTS rate of Type B PPF 2.1% requiring revision/fixation. Compared to cTHA this cohort was significantly older (74.0 vs 68.3 years), more co-morbidity (ASA 3 46.5% vs 14.4%) and more non-OA indications (32.4% vs 8.5%). Relative risks for dislocation 0.57 (95%CI 0.08–4.1) and PPF 1.75 (95%CI 0.54–5.72). Every patient had at least one risk factor for falling and >50% of cohort had 4 or more risk factors using NICE tool. The selective use of DM in high-risk patients can reduce the burden of instability. These individuals are very different to the “average” THA patient. A “perfect storm” is created using a high-risk implant combination (DM & PTS) in high-risk falls risk population. This re-enforces the need to consider all patient and implant factors when deciding bearing selection


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 79 - 79
11 Apr 2023
Underwood T Mastan S O'Brien S Welton C Woodruff M
Full Access

There has been extensive research into neck of femur fractures in the elderly. Fragility non-hip femoral fractures share many of the same challenges [1]. Surgical management is complex, patients are frail and mortality rates have been reported as high as 38% [2]. Despite this, relatively little data is available evaluating the level of MDT care provided to non-hip femoral fractures. This audit aimed to evaluate the standard of MDT care provided for patients with non-hip femoral fractures according to the NHFD key performance indicators. The following fractures were included in the dataset: distal femoral, femoral shaft and peri-prosthetic femoral. Patients under 65 were excluded. Data was retrospectively collected using post-operative and medical documentation. Performance was assessed according to five key performance indicators:. Did orthogeriatrics review the patient within 72-hours?. Was surgery performed within 36-hours?. Was the patient weight bearing post-operatively?. Was a confusion assessment completed?. Was the patient discharged home?. 38 patients met the inclusion criteria. 84% of patients were seen by orthogeriatrics within 72 hours of admission. 32% of patients were operated on within 36-hours of admission, with time to theatre exceeding 36-hours in 92% of peri-prosthetic fractures. 37% of patients were not advised to full weight bear post operatively. 84% of patients received a confusion assessment whilst 61% of patients were discharged to their prior place of living. Our results suggest that non-hip femoral fractures do not receive the same standard of MDT care as neck of femur fractures. Greater prioritisation of resources should be given to this patient subset so that care is equivalent to hip-fracture patients. Time to surgery is a particular area for improvement, particularly in peri-prosthetic fractures, a trend that is mirrored nationally. Greater emphasis should be placed on encouraging full-weight bearing post-operatively to prevent post-surgical complications


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 5 - 5
4 Apr 2023
Vicary-Watts R McLauchlan G
Full Access

Cannulated hip screws are frequently used in the management of hip fractures. There have been concerns over the failure rate of the technique and the outcomes of those that subsequently require conversion to total hip replacement (THR). This study utilised a database of over 600 cannulated hip screw (CHS) fixations performed over a 14-year period and followed up for a minimum of one year (1-14). We identified 57 cases where a conversion to THR took place (40 females, 17 males, mean age: 71.2 years). Patient demographics, original mechanism of injury, fracture classification, reason for fixation failure, time until arthroplasty, implant type and post-arthroplasty complications were recorded. Clinical outcomes were measured using the Oxford Hip Score. The failure rate of cannulated screw treatment was 9.4% and the mean time from initial fixation to arthroplasty was 15.4 (16.5) months. Thirty six fractures were initially undisplaced and 21 were displaced. As one might expect the displaced cases tended to be younger but this didn't reach statistical significance [66.5(14.3) vs 72.7(13.1), p=0.1]. The commonest causes of failure were non-union (25 cases, 44%) and avascular necrosis (17 cases, 30%). Complications after THR consisted of one leg length discrepancy and one peri-prosthetic fracture. The mean Oxford score pre-arthroplasty was 12.2 (8.4), improving to 38.4 (11.1) at one-year. Although the pre op Oxford scores tended to be lower in patients with undisplaced fractures and higher ASA scores, the improvement was the same whatever the pre-op situation. The one-year Oxford score and the improvement in score are comparable to those seen in the literature for THR in general. In conclusion, CHS has a high success rate and where salvage arthroplasty is required it can provide good clinical outcomes with low complication rates


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 108 - 108
4 Apr 2023
Wen Z Ding Y Lin S Li C Ouyang Z
Full Access

As peri-prosthetic aseptic loosening is one of the main causes of implant failure, inhibiting wear particles induced macrophages inflammation is considered as a promising therapy for AL to expand the lifespan of implant. Here, we aim at exploring the role of p110δ, a member of class IA PI3K family, and Krüppel-like factor 4 (KLF4) in titanium particles (TiPs) induced macrophages-inflammation and osteolysis. Firstly, IC87114, the inhibitor of p110δ and siRNA targeting p110δ were applied and experiments including ELISA and immunofluorescence assay were conducted to explore the role of p110δ. Sequentially, KLF4 was predicted as the transcription factor of p110δ and the relation was confirmed by dual luciferase reporter assay. Next, assays including RT-PCR, western blotting and flow cytometry were performed to ensure the specific role of KLF4. Finally, TiPs-induced mice cranial osteolysis model was established, and micro-CT scanning and immunohistochemistry assay were performed to reveal the role of p110δ and KLF4 in vivo. Here, we found that p110δ was upregulated in TiPs-stimulated macrophages. The inhibition of p110δ or knockdown of p110δ could significantly dampen the TiPs-induced secretion of TNFα and IL-6. Further mechanistic studies confirmed that p110δ was responsible for TNFα and IL-6 trafficking out of Golgi complex without affecting their expression in TiPs-treated macrophages. Additionally, we explored the upstream regulators and confirmed that Krüppel-like factor 4 (KLF4) was the transcription repressor of p110δ. Apart from that, KLF4, targeted by miR-92a, could also attenuate TiPs-induced inflammation by mediating NF-κB pathway and M1/M2 polarization. By the establishment of TiPs-induced mice cranial osteolysis model, we found that KLF4 knockdown exacerbated TiPs-induced osteolysis which was strikingly ameliorated by knockdown of p110δ. In summary, our study suggests the key role of miR-92a/KLF4/p110δ signal in TiPs-induced macrophages inflammation and osteolysis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 112 - 112
10 Feb 2023
Ross M Vince K Hoskins W
Full Access

Constrained implants with intra-medullary fixation are expedient for complex TKA. Constraint is associated with loosening, but can correction of deformity mitigate risk of loosening?. Primary TKA's with a non-linked constrained prosthesis from 2010-2018 were identified. Indications were ligamentous instability or intra-medullary fixation to bypass stress risers. All included fully cemented 30mm stem extensions on tibia and femur. If soft tissue stability was achieved, a posterior stabilized (PS) tibial insert was selected. Pre and post TKA full length radiographs showed. i. hip-knee-ankle angles (HKAA). ii. Kennedy Zone (KZ) where hip to ankle vector crosses knee joint. 77 TKA's in 68 patients, average age 69.3 years (41-89.5) with OA (65%) post-trauma (24.5%) and inflammatory arthropathy (10.5%). Pre-op radiographs (62 knees) showed varus in 37.0%. (HKAA: 4. o. -29. o. ), valgus in 59.6% (HKAA range 8. o. -41. o. ) and 2 knees in neutral. 13 cases deceased within 2 years were excluded. Six with 2 year follow up pending have not been revised. Mean follow-up is 6.1 yrs (2.4-11.9yrs). Long post-op radiographs showed 34 (57.6%) in central KZ (HKKA 180. o. +/- 2. o. ). . Thirteen (22.0%) were in mechanical varus (HKAA 3. o. -15. o. ) and 12 (20.3%) in mechanical valgus: HKAA (171. o. -178. o. ). Three failed with infection; 2 after ORIF and one with BMI>50. The greatest post op varus suffered peri-prosthetic fracture. There was no aseptic loosening or instability. Only full-length radiographs accurately measure alignment and very few similar studies exist. No cases failed by loosening or instability, but PPF followed persistent malalignment. Infection complicated prior ORIF and elevated BMI. This does not endorse indiscriminate use of mechanically constrained knee prostheses. Lower demand patients with complex arthropathy, especially severe deformity, benefit from fully cemented, non-linked constrained prostheses, with intra-medullary fixation. Hinges are not necessarily indicated, and rotational constraint does not lead to loosening


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 86 - 86
10 Feb 2023
Nizam I Alva A Dabirrahmani D Choudary D
Full Access

Direct anterior approach (DAA) arthroplasty has generated great interest because of its minimally invasive and muscle sparing nature. Obese patients are reported to be associated with greater incidence of complications in primary joint replacement. The purpose of this study was to compare patient outcomes and complication rates between obese and non-obese patients undergoing primary total hip arthroplasty (THA) through a Bikini direct anterior incision. This retrospective, single surgeon study compared the outcome of 258 obese patients and 200 non-obese patients undergoing DAA THA using a Bikini incision, over a 7-year period. The average follow-up was 4.2 years (range 2.6-7.6 years). There were no statistically significant differences in the complication rate between the two groups. The obese group recorded 2 major (venous thromboembolism and peri-prosthetic fracture) and 2 minor complications (superficial wound infection), compared with the non-obese group, which recorded 2 major (deep-wound infection and peri-prosthetic fracture) and 1 minor complication (superficial wound infection). Patient-reported outcomes (WOMAC and Harris Hip Scores) showed significant post-operative improvements (p < 0.001) and did not differ between the two groups. Bikini DDA THA does not increase the complication rate in obese patients and offers similar clinical improvements compared to non-obese patients. (200 words)


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 34 - 34
1 Dec 2022
Lapner P Pollock J Hodgdon T Sheikh A Shamloo A Fernandez AA McIlquham K Desjardins M Drosdowech D Nam D Rouleau D
Full Access

The diagnosis of infection following shoulder arthroplasty is notoriously difficult. The prevalence of prosthetic shoulder infection after arthroplasty ranges from 3.9 – 15.4% and the most common infective organism is Cutibacterium acnes. Current preoperative diagnostic tests fail to provide a reliable means of diagnosis including WBC, ESR, CRP and joint aspiration. Fluoroscopic-guided percutaneous synovial biopsy (PSB) has previously been reported in the context of a pilot study and demonstrated promising results. The purpose of this study was to determine the diagnostic accuracy of percutaneous synovial biopsy compared with open culture results (gold standard). This was a multicenter prospective cohort study involving four sites and 98 patients who underwent revision shoulder arthroplasty. The cohort was 60% female with a mean age was 65 years (range 36-83 years). Enrollment occurred between June 2014 and November 2021. Pre-operative fluoroscopy-guided synovial biopsies were carried out by musculoskeletal radiologists prior to revision surgery. A minimum of five synovial capsular tissue biopsies were obtained from five separate regions in the shoulder. Revision shoulder arthroplasty was performed by fellowship-trained shoulder surgeons. Intraoperative tissue samples were taken from five regions of the joint capsule during revision surgery. Of 98 patients who underwent revision surgery, 71 patients underwent both the synovial biopsy and open biopsy at time of revision surgery. Nineteen percent had positive infection based on PSB, and 22% had confirmed culture positive infections based on intra-operative tissue sampling. The diagnostic accuracy of PSB compared with open biopsy results were as follows: sensitivity 0.37 (95%CI 0.13-0.61), specificity 0.81 (95%CI 0.7-0.91), positive predictive value 0.37 (95%CI 0.13 – 0.61), negative predictive value 0.81 (95%CI 0.70-0.91), positive likelihood ratio 1.98 and negative likelihood ratio 0.77. A patient with a positive pre-operative PSB undergoing revision surgery had an 37% probability of having true positive infection. A patient with a negative pre-operative PSB has an 81% chance of being infection-free. PSB appears to be of value mainly in ruling out the presence of peri-prosthetic infection. However, poor likelihood ratios suggest that other ancillary tests are required in the pre-operative workup of the potentially infected patient


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 85 - 85
1 Jul 2022
Rahman A Heath D Mellon S Murray D
Full Access

Abstract. Introduction. In cementless UKR, primary fixation of the tibial component is achieved by press-fitting a keel (i.e. with interference) into a vertical slot cut into the proximal tibia. This may adversely affect the structural integrity of surrounding bone. Early post-operative peri-prosthetic tibial fractures are 7x more common in very small knees, but the aetiology of these fractures is unknown - such sizes are rarely used in the UK but more common in Asian populations. This study explores the effect of keel-related features in fracture risk of these very small tibias. Method. This in vitro study compares the effect of keel and slot depth (standard vs 33% shallower vs nil) and loading position (anterior/posterior gait range limits: mid-tibia vs 8mm posterior) on fracture load and path. 3D-printed titanium components were implanted using surgical instrumentation/technique, in bone-analogue foam machined to a CT-reconstructed very small tibia which subsequently experienced a peri-prosthetic fracture. Results. Introducing a standard slot reduces load-to-fracture by 50% (1421N-vs-710N, p<0.0001). Press-fitting a standard keel further reduces load-to-fracture by 40% (710N-vs-423N, p=0.0001). A shallower slot/keel increases load-to-fracture substantially (slot: 27% increase, 904N-vs-710N p=0.0003, slot+keel: 60% increase, 683N-vs-423N p=0.0004). Deeper keels fractured more vertically (current 8.2° vs shallow 15.5° vs nil 21°, degrees-to-vertical, p<0.0001). There was no difference caused by loading position. Conclusion. In very small tibias, a standard cementless keel significantly weakens the bone and may contribute to fractures. Therefore, decreasing interference or using a shallower keel should decrease the risk of fracture, although it might compromise fixation


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 91 - 91
1 Jul 2022
Jones CS Johansen A Inman D Eardley W Toms A Evans J
Full Access

Abstract. Introduction. Inter-prosthetic femoral fractures (IPFF) are fractures occurring between ipsilateral hip and knee implants or fixation devices. In 2020, the National Hip Fracture Database (NHFD) was extended to capture data from patients with peri-prosthetic femoral fractures (PPFF), including those specifically with IPFF. This study aims to describe the epidemiology and treatment of IPFF in England and Wales. Methodology. This population-based observational cohort study utilised open-access data available from the NHFD. Patients aged over 60, admitted to an acute hospital in England or Wales with an IPFF, within the period 1st January 2020 to 31st December 2020 were included. The primary outcome of this study was the incidence of IPFF in England and Wales. The secondary outcome was the treatment received. Results. Of 2606 patients admitted with PPFF, a total of 133 fractures occurred between ipsilateral hip and knee implants. Internal fixation was performed most frequently, in 87 cases. Revision arthroplasty was performed in 15 cases (hip n=10, knee n=5). A total of 20 patients were managed non-operatively, and three underwent primary arthroplasty (hip n=2, knee n=1). Conclusion. As the proportion of patients living with hip and knee implants continues to increase, it is expected that so too will the incidence of IPFF. This study is the first to estimate the incidence of IPFF in England and Wales. This is likely an underestimate of the true incidence and so we support calls for the prioritisation of further research into the epidemiology, prevention, and management of IPFF


Bone & Joint Open
Vol. 3, Issue 6 | Pages 495 - 501
14 Jun 2022
Keohane D Sheridan GA Masterson E

Aims

Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component.

Methods

A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option).


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 22 - 22
1 Apr 2022
Lewis C Baker M Brooke B Metcalf B McWilliams G Sidhom S
Full Access

Constrained acetabular inserts provide a solution for both complex primary and revision hip arthroplasty, but there have been ongoing concerns for high risk of failure and their longevity. The Stryker® Trident acetabular insert is pre-assembled with its constrained ring. We believe this to be the largest series of constrained acetabular inserts with a minimum of 5 year follow-up. We retrospectively reviewed all Stryker® Trident ‘All-Poly’ constrained acetabular inserts cemented into bone in our unit between 2008 and 2016. We collated demographic details and reviewed all patients’ radiographs and clinical notes. Indications for surgery, latest Oxford Hip Scores (OHS) and clinical and radiographic complications were identified. 117 consecutive Stryker® Trident ‘All-Poly’ constrained inserts were cemented into bone in 115 patients during the study period with a mean age of 80 (47–97). Most common indications for surgery were recurrent dislocation (47), complex primary arthroplasty (23), revision arthroplasty (19) and failed hemiarthroplasty (12). 41 patients required revision of the acetabular component only. Follow-up was a minimum of 5 years (mean 8.6, range 5–13). There were three 30-day mortalities and six 1-year mortalities. The mean latest OHS was 37 (24–45). Four cups failed in three patients, one at the cement-bone interface, two at the cement-prosthesis interface and one at the bipolar interface. These were treated conservatively in three patient and with excision arthroplasty in one patient. There were four peri-prosthetic fractures, one Vancouver C distal femur fracture treated conservatively and three Vancouver B1 fractures, two treated conservatively and one treated with open reduction internal fixation. There was breakage of one constrained ring with no adverse effects and one superficial wound infection requiring oral antibiotics only. This series demonstrated that despite the elderly and complex nature of these patients’ clinical situations, constrained acetabular inserts offer a useful and pragmatic solution, with relatively low complications, including in our series a cup failure rate of 3% and peri-prosthetic fracture rate of 3%


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 27 - 27
1 Apr 2022
Evans J Inman D Johansen A
Full Access

The National Hip Fracture Database (NHFD) started collecting data on peri-prosthetic femoral fractures (PPFF) in December 2019. We reviewed the data from the first year of data collection to describe the patients being admitted with PPFF and the care they received according to established Key Performance Indicators (KPIs) used in hip fracture surgery. We performed a retrospective review of the NHFD between 1 January and 31 December 2020. Analyses consisted of the summary statistics used to generate the NHFD annual report. Of the KPIs used in hip fracture, data were available for PPFF on time to assessment by a geriatrician (KPI 1), time to theatre (if applicable) (KPI 2), and mobilisation the day after surgery (if applicable) (KPI 4). There were 2,411 PPFF fractures around a hip or knee replacement reported out of a total of 2,606 PPFF. Of the 171 hospitals reporting data to the NHFD, 135 reported at least one. The median number of fractures per hospital was 14 (IQR 8, 25, range 1 to 110). The median age of patients was 84 (range 60 to 104) and 1,604 (67%) patients were female. Of the 1,850 occasions a time to geriatrician review was documented, review within 72 hours was achieved on 89.2% of occasions. Of the 1,973 patients who underwent operative interventions, 546 patients went to theatre before the 36-hour target (28.4%). Of patients who had surgery 1,323 (67.4%) were mobilised the following day. In the first year collecting data on PPFF we can give the first idea of the incidence of these life changing injuries. Whilst geriatrician review with 72 hours was achieved in a high proportion of cases nationally, our data suggest fewer patients are mobilised the day after surgery. Notably, only 28.4% of patients who were managed operatively went to theatre within 36 hours of admission. We provide the first insight into the incidence and management of these injuries