Advertisement for orthosearch.org.uk
Results 1 - 20 of 1051
Results per page:
Bone & Joint Open
Vol. 6, Issue 2 | Pages 186 - 194
13 Feb 2025
Battaglia AG D'Apolito R Ding BTK Tonolini S Ramazzotti J Zagra L

Aims

Revision hip arthroplasty for femoral stem loosening remains challenging due to significant bone loss and deformities requiring specialized revision stems. The aim of this study was to evaluate the clinical and radiological outcomes, and survival, of a consecutive series of femoral revisions performed using a primary cementless stem with tapered geometry and rectangular cross-section at medium-term follow-up.

Methods

We retrospectively evaluated 113 patients (115 hips) with intraoperative Paprosky type I (n = 86) or II (n = 29) defects, who underwent femoral revision with Alloclassic Zweymüller SL stem for one-stage aseptic revision or two-stage septic revision from January 2011 to December 2020. The mean follow-up was 77.9 months (SD 33.8). Nine patients were lost to follow-up (deceased or not available), leaving 104 patients (106 hips) for the clinical and radiological analysis. Clinical assessment was performed with Harris Hip Score (HHS) and visual analogue scale (VAS) before surgery and at final follow-up.


The Bone & Joint Journal
Vol. 107-B, Issue 2 | Pages 253 - 260
1 Feb 2025
Sambri A Campanacci DA Pala E Smolle MA Donati DM van de Sande MAJ Vyrva O Leithner A Jeys L Ruggieri P De Paolis M

Aims. The aim of this study was to assess the incidence of reinfection in patients after two-stage revision of an infected megaprosthesis (MPR) implanted after resection of a bone tumour. Methods. A retrospective study was carried out of 186 patients from 16 bone sarcoma centres treated between January 2010 and December 2020. The median age at the time of tumour diagnosis was 26 years (IQR 17 to 33); 69 (37.1%) patients were female, and 117 (62.9%) were male. Results. A total of 186 patients with chronic MPR infections were included. Median follow-up was 68 months (IQR 31 to 105). The most represented sites of MPR were distal femur in 93 cases (50.0%) and proximal tibia in 53 cases (28.5%). Polymicrobial infections were seen in 34 cases (18.3%). The most frequent isolated pathogens were staphylococci. Difficult-to-treat (DTT) pathogens were isolated in 50 cases (26.9%). The estimated infection recurrence (IR) rate was 39.1% at five years and 50.0% at ten years. A higher IR rate was found in DTT PJI compared to non-DTT infections (p = 0.019). Polymicrobial infections also showed a higher rate of infection recurrence (p = 0.046). Conclusion. This study suggests that an infected MPR treated by two-stage revision and ultimately reimplantation with a MPR can be successful, but the surgeon must be aware of a high recurrence rate compared to those seen with infected conventional implants. Cite this article: Bone Joint J 2025;107-B(2):253–260


The Bone & Joint Journal
Vol. 107-B, Issue 2 | Pages 157 - 163
1 Feb 2025
Hu M Zhang Y Guo C Yang X Xu H Xiang S

Aims

To evaluate the concurrent use of vancomycin and ε-aminocaproic acid (EACA) in primary total hip arthroplasty (THA).

Methods

In total, 120 patients undergoing unilateral primary THA were divided into three groups: Group VE received intra-articular vancomycin and EACA; Group V received only intra-articular vancomycin; and Group E received only intra-articular EACA. Blood and joint fluids were sampled postoperatively to measure the vancomycin levels using chromatography. Blood loss and kidney function were monitored.


Bone & Joint Research
Vol. 14, Issue 1 | Pages 42 - 45
21 Jan 2025
Fontalis A Wignadasan W Kayani B Haddad FS


Bone & Joint Open
Vol. 6, Issue 1 | Pages 12 - 20
3 Jan 2025
Chan KCA Cheung A Chan P Luk MH Chiu KY Fu H

Aims

Around the world, the emergence of robotic technology has improved surgical precision and accuracy in total knee arthroplasty (TKA). This territory-wide study compares the results of various robotic TKA (R-TKA) systems with those of conventional TKA (C-TKA) and computer-navigated TKA (N-TKA).

Methods

This is a retrospective study utilizing territory-wide data from the Clinical Data Analysis and Reporting System (CDARS). All patients who underwent primary TKA in all 47 public hospitals in Hong Kong between January 2021 and December 2023 were analyzed. Primary outcomes were the percentage use of various robotic and navigation platforms. Secondary outcomes were: 1) mean length of stay (LOS); 2) 30-day emergency department (ED) attendance rate; 3) 90-day ED attendance rate; 4) 90-day reoperation rate; 5) 90-day mortality rate; and 6) surgical time.


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 58 - 64
1 Jan 2025
Carender CN Bedard NA Fruth KM Taunton MJ Pagnano MW Abdel MP

Aims

The purpose of this study was to directly compare the Modular Dual Mobility (MDM) Mobile Bearing Hip System (Stryker, USA) and large femoral heads (LFHs) in revision total hip arthroplasties (THAs) at mid-term follow-up, with specific emphasis on survival free of re-revision for dislocation, any re-revision, dislocation, and the risk of metal-related complications.

Methods

We identified 299 revision THAs performed at a single tertiary care academic institution from March 2011 to July 2014. Aseptic loosening of the acetabular component (n = 65), dislocation (n = 58), and reimplantation as part of a two-stage exchange protocol (n = 57) were the most common reasons for index revision. MDM constructs were used in 123 cases, and LFHs were used in 176 cases. Mean age was 66 years (28 to 93), mean BMI was 31 kg/m2 (18 to 55), and 45% (n = 136) were female. Mean follow-up was seven years (2 to 12).


Bone & Joint 360
Vol. 13, Issue 6 | Pages 45 - 47
1 Dec 2024

The December 2024 Research Roundup360 looks at: Skeletal muscle composition, power, and mitochondrial energetics in older men and women with knee osteoarthritis; Machine-learning models to predict osteonecrosis in patients with femoral neck fractures undergoing internal fixation; Aetiology of patient dissatisfaction following primary total knee arthroplasty in the era of robotic-assisted technology; Efficacy and safety of commonly used thromboprophylaxis agents following hip and knee arthroplasty; The COVID-19 effect continues; Nickel allergy in knee arthroplasty: does self-reported sensitivity affect outcomes?; Tranexamic acid use and joint infection risk in total hip and knee arthroplasty.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1416 - 1425
1 Dec 2024
Stroobant L Jacobs E Arnout N Van Onsem S Tampere T Burssens A Witvrouw E Victor J

Aims

Approximately 10% to 20% of knee arthroplasty patients are not satisfied with the result, while a clear indication for revision surgery might not be present. Therapeutic options for these patients, who often lack adequate quadriceps strength, are limited. Therefore, the primary aim of this study was to evaluate the clinical effect of a novel rehabilitation protocol that combines low-load resistance training (LL-RT) with blood flow restriction (BFR).

Methods

Between May 2022 and March 2024, we enrolled 45 dissatisfied knee arthroplasty patients who lacked any clear indication for revision to this prospective cohort study. All patients were at least six months post-surgery and had undergone conventional physiotherapy previously. The patients participated in a supervised LL-RT combined with BFR in 18 sessions. Primary assessments included the following patient-reported outcome measures (PROMs): Knee injury and Osteoarthritis Outcome Score (KOOS); Knee Society Score: satisfaction (KSSs); the EuroQol five-dimension five-level questionnaire (EQ-5D-5L); and the pain catastrophizing scale (PCS). Functionality was assessed using the six-minute walk Test (6MWT) and the 30-second chair stand test (30CST). Follow-up timepoints were at baseline, six weeks, three months, and six months after the start.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1426 - 1430
1 Dec 2024
Warne CN Ryan S Yu E Osmon DR Berry DJ Abdel MP

Aims. Cutibacterium acnes (C. acnes; previously known as Propionibacterium acnes or P. acnes) periprosthetic hip and knee infections are under-reported. While culture contamination with C. acnes occurs, true infections are important to recognize and treat. We sought to describe the demographics and treatment outcomes of patients with C. acnes periprosthetic joint infections (PJIs) of the hip and knee. Methods. Patients with C. acnes PJI between January 2005 and December 2018 were retrospectively reviewed utilizing the institutional total joint registry. Patients with monomicrobial PJI and two or more positive cultures were considered to have true C. acnes PJI. Patients with polymicrobial infection or with only one positive culture were excluded. This resulted in 35 PJIs (21 hips and 14 knees); the patients’ mean age was 63 years (35 to 84) and 15 (43%) were female. Mean follow-up was five years (1 to 14). Results. The median time to positive culture was five days (IQR 5 to 6) and median synovial fluid cell count was 22,583 cells (IQR 15,200 to 53,231). The median ESR was 25 mm/hr (IQR 7 to 37), and CRP was 15 mg/l (IQR 3 to 29). Of the 35 PJIs, 18 (51%) were treated with chronic antibiotic suppression without surgical intervention, and the remainder were treated with two-stage exchange arthroplasty. The two-year survival free of any revision was 94%. Four patients failed treatment due to symptomatic infection, with three treated with two-stage exchange and one treated with irrigation and debridement with modular component exchange for a survival rate of 89% and 83% at two and five years, respectively. Conclusion. Laboratory evidence of C. acnes PJI in this cohort was typical compared to more conventional organisms. Cultures grew more quickly than previously thought in patients with C. acnes PJI. Treatment with two-stage exchange or chronic antibiotic suppression alone both had few treatment failures at mid-term follow-up. Cite this article: Bone Joint J 2024;106-B(12):1426–1430


Bone & Joint Research
Vol. 13, Issue 12 | Pages 695 - 702
1 Dec 2024
Cordero García-Galán E Medel-Plaza M Pozo-Kreilinger JJ Sarnago H Lucía Ó Rico-Nieto A Esteban J Gomez-Barrena E

Aims

Electromagnetic induction heating has demonstrated in vitro antibacterial efficacy over biofilms on metallic biomaterials, although no in vivo studies have been published. Assessment of side effects, including thermal necrosis of adjacent tissue, would determine transferability into clinical practice. Our goal was to assess bone necrosis and antibacterial efficacy of induction heating on biofilm-infected implants in an in vivo setting.

Methods

Titanium-aluminium-vanadium (Ti6Al4V) screws were implanted in medial condyle of New Zealand giant rabbit knee. Study intervention consisted of induction heating of the screw head up to 70°C for 3.5 minutes after implantation using a portable device. Both knees were implanted, and induction heating was applied unilaterally keeping contralateral knee as paired control. Sterile screws were implanted in six rabbits, while the other six received screws coated with Staphylococcus aureus biofilm. Sacrifice and sample collection were performed 24, 48, or 96 hours postoperatively. Retrieved screws were sonicated, and adhered bacteria were estimated via drop-plate. Width of bone necrosis in retrieved femora was assessed through microscopic examination. Analysis was performed using non-parametric tests with significance fixed at p ≤ 0.05.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1377 - 1384
1 Dec 2024
Fontalis A Yasen AT Giebaly DE Luo TD Magan A Haddad FS

Periprosthetic joint infection (PJI) represents a complex challenge in orthopaedic surgery associated with substantial morbidity and healthcare expenditures. The debridement, antibiotics, and implant retention (DAIR) protocol is a viable treatment, offering several advantages over exchange arthroplasty. With the evolution of treatment strategies, considerable efforts have been directed towards enhancing the efficacy of DAIR, including the development of a phased debridement protocol for acute PJI management. This article provides an in-depth analysis of DAIR, presenting the outcomes of single-stage, two-stage, and repeated DAIR procedures. It delves into the challenges faced, including patient heterogeneity, pathogen identification, variability in surgical techniques, and antibiotics selection. Moreover, critical factors that influence the decision-making process between single- and two-stage DAIR protocols are addressed, including team composition, timing of the intervention, antibiotic regimens, and both anatomical and implant-related considerations. By providing a comprehensive overview of DAIR protocols and their clinical implications, this annotation aims to elucidate the advancements, challenges, and potential future directions in the application of DAIR for PJI management. It is intended to equip clinicians with the insights required to effectively navigate the complexities of implementing DAIR strategies, thereby facilitating informed decision-making for optimizing patient outcomes. Cite this article: Bone Joint J 2024;106-B(12):1377–1384


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 12 - 12
22 Nov 2024
Wang L Trampuz A Zhang X
Full Access

Aim. Treatment of prosthetic joint infection (PJI) by systemic administration of high doses of long-term antibiotics often proves ineffective, causing severe side effects. Thus, we presented the phage Sb-1, which coding extracellular polymeric substances (EPS) degradation depolymerases, conjugated with rifampicin-loaded liposomes (Lip-RIF@Phage) by bio-orthogonal functionalization strategy to target biofilm (Figure1). Method. Methicillin-resistant Staphylococcus aureus (MRSA) biofilm was grown on porous glass beads for 24 h in vitro. After the biofilm formation, beads were exposed to 0.9% saline, then sonication. Quantitative and qualitative biofilm analyses were performed by colony counting, scanning electron microscopy and isothermal microcalorimetry. A rat model of total knee arthroplasty infected with the bioluminescent MRSA strain was developed as the PJI model to evaluate the efficacy of Lip-RIF@Phage anti-biofilm therapy in vivo, then the creatinine, alanine transaminase, and aspartate transaminase values were evaluated throughout the entire treatment process. Results. After treatment with Lip-RIF@Phage, no bacterial colonies were observed, consistent with findings from scanning electron microscopy. Similarly, isothermal microcalorimetry revealed no detectable heat following Lip-RIF@Phage treatment, aligning with these observations. In vivo experiments demonstrated a significant reduction in biofilm cell load compared to all other tested conditions, with no evidence of systemic toxicity on renal and liver functions attributed to Lip-RIF@Phage. Conclusions. The innovative depolymerase-phagobot nanosystem (Lip-RIF@Phage) exhibits remarkable efficacy in completely eliminating biofilm cells in vitro. It serves as an excellent carrier for antibiotic delivery, enhancing antibiotic penetration through biofilms and improving biofilm eradication efficacy. Furthermore, it enables personalized treatment strategies against biofilm-associated multidrug-resistant (MDR) infections by maximizing the effectiveness of any remaining sensitive antibiotics. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 13 - 13
22 Nov 2024
McNally M Dietz M Piuzzi N Chen A Parvizi J Stolarski E Pelt C Rodriguez-Quintana D Trautner B Dobbins D
Full Access

Aim. Antimicrobial peptides occur naturally in our intrinsic immune system. PLG0206 is a novel, engineered, 24-amino acid peptide which has broad-spectrum antimicrobial activity, including in biofilm and against multi-drug resistant pathogens (1,2). This is the first clinical study to evaluate the safety and tolerability of PLG0206 when administered via an irrigation solution in patients with periprosthetic joint infections (PJI) following total knee arthroplasty (TKA) during debridement, antibiotics, and implant retention (DAIR). Secondary objectives were to evaluate pharmacokinetics (PK), biomarkers and initial clinical efficacy at one year post-DAIR procedure. Method. This prospective, multicenter, open-label, interventional study assessed two dose levels of PLG0206. Fourteen patients underwent revision for PJI after TKA. At the end of debridement, they received a single intra-articular irrigation of PLG0206 into the wound cavity lasting 15 minutes at concentrations of 3 mg/mL (n=7) or 10 mg/mL (n=7). Patients received post-operative care and intravenous/oral antimicrobial therapy as per their institutional guidelines. Patients were monitored for safety and signs of relapse or persistent infection for 12 months post study drug administration and PK and blood biomarkers were assessed. Results. All patients completed their final study assessment at Day 365. Over the 1-year follow-up, only one recurrence (7%) was noted at Day 169 in the low-dose cohort. Following dosing, nine patients (64.3%) had limited systemic exposure; maximum plasma concentration occurred 1-hour post-administration and declined rapidly to undetectable levels by 24 hours following treatment in all patients. The incidence of drug related treatment-emergent adverse events (TEAEs) was low. Two patients, both in the higher dose cohort, experienced a transient drug related TEAE; one of hypertransaminasaemia and one of neuralgia. Both events were moderate in severity and resolved within two weeks of onset. Conclusions. A single 15-minute irrigation of PLG0206 into the wound cavity of patients undergoing a DAIR procedure for PJI following TKA, is safe and well tolerated by patients. This new antimicrobial peptide offers a promising therapeutic option in musculoskeletal infection. The initial clinical efficacy is encouraging but now needs to be investigated in a much larger clinical trial


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 26 - 26
22 Nov 2024
Karlsen ØE Eriksen-Volle H Furnes O Dale H Westberg M
Full Access

Aim. Two types of national registers surveil infections after primary total hip arthroplasty (THA) in Norway: The National surveillance system for surgical site infections (NOIS) that surveil all primary THAs 30 days postoperatively for surgical site infections (SSI), and the Norwegian Arthroplasty Register (NAR) that follow all THAs until any surgical reoperation/revision or the death of the patient. Since these registers report on the same THAs we assessed correspondence between and time trends for the two registers in period 2013 to 2022. All reported THAs were included. Method. The THAs were matched on a group level according to sex, age and ASA-class. In addition to descriptive statistics, adjusted Cox regression analyses were performed with adjustment for sex, age group (<45, 45-54, 55-64, 65-74, 75-84, >85 years) and ASA-class (1, 2, 3, 4 and missing). Changes in annual incidence and adjusted hazard rate (aHR) was calculated. Endpoints in the NOIS were 30-Days SSI and 30-Days reoperation for SSI. Endpoints in the NAR were 30-Days and 1-Year reoperation for periprosthetic joint infection (PJI). Results. The NOIS had registered 87,923 THAs with 1,393 (1.58%) SSIs and 765 (0.87%) reoperations for SSI within 30 postoperatively. The NAR had registered 91,194 THAs with 725 (0.80%) reoperations for infection after 30 days, and 1,019 (1.21%) reoperations for infections after one year. The distribution of sex, age and ASA-class was near identical in the two registers. There was a mean annual reduction in risk of both SSI (aHR 0.92 (95% CI 0.90-0.93)) and reoperation for SSI (0.95(0.92-0.97)) and PJI (30-Days: 0.96 (0.94-0.99), 1-Year: 0.95-0.99)) over the period 2013-2022. Conclusions. The NOIS and the NAR have excellent completeness and the registrations in both registers may be considered representative for the Norwegian population. Not all SSI are reoperated. The incidence and risk of SSI (NOIS) and reoperation for PJI (NAR) is declining and may reflect a true reduction in incidence of PJI after primary THA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 33 - 33
22 Nov 2024
Kristensen N Manning L Lange J Davis J
Full Access

Aim. Periprosthetic Joint Infection (PJI) is a devastating complication in hip and knee joint arthroplasty. The “JS BACH” classification system was developed in 2021 to stratify the complexity of PJI, and more importantly, to act as a tool to guide referrals to specialist centers. The “JS BACH” classification has not been validated in an external cohort. This study aimed to do so using a large prospective cohort from Australia and New Zealand. Method. We applied the JS-BACH classification to the Prosthetic Joint Infection in Australia and New Zealand Observational (PIANO) cohort. This prospective study of newly diagnosed PJI collected 2-year outcome data from 653 participants enrolled in 27 hospitals. The definition of PJI treatment failure at 24 months was any of the following: death, clinical or microbiological signs of infection, destination prosthesis removed, or ongoing antibiotic use. Results. Individual cases were classified as per JS-BACH into “1 - uncomplicated” (n = 268), “2 - complex” (n = 330), and “3 - limited options” (n = 55). This cohort was similar to the original JS-BACH population in terms of baseline characteristics. However, there was a difference in complexity, with more DAIR procedures, fewer revision procedures, and a higher proportion of uncomplicated patients in the PIANO cohort. The risk of treatment failure correlated strongly with the JS-BACH category, with odds ratios (95% CI [confidence interval]) for category 2 versus 1 of 1.75 (1.24 to 2.47) and for category 3 versus 1 of 7.12 (3.42 to 16.02). Conclusions. Despite the PIANO study population being less complicated than the original derivation cohort, the JS-BACH classification showed a clear association with treatment failure in this large external cohort


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 47 - 47
22 Nov 2024
Mitterer JA Hartmann SG Simon S Sebastian S Chlud L Hofstaetter JG
Full Access

Background. Two-stage revision arthroplasty is the standard treatment for chronic hip and knee periprosthetic joint infections (PJI). Accurate diagnosis of persistent infections at 2nd stage using established biomarkers and diagnostic criteria is of paramount importance. This study aimed to evaluate the diagnostic value of synovial calprotectin and alpha-defensin, and compare established diagnostic criteria from the International Consensus Meeting (ICM 2018) and the European Bone and Joint Infection Society (EBJIS 2021) to determine persistent PJI at the 2nd stage of a two-stage revision arthroplasty. Methods. We retrospectively analyzed 97 patients who underwent 100 two-stage revisions (hip: 39, knee: 61). Synovial fluid samples were assessed for calprotectin and alpha-defensin levels. ICM 2018 and EBJIS 2021 were applied to all patients undergoing 2nd stage revision. Receiver operating characteristic (ROC) curves and Youden Index were utilized to determine optimal cut-off values, and correlations between biomarkers were evaluated. The microbiological spectrum was analyzed at 2nd stage and re-revision surgery. Results. Calprotectin levels showed a sensitivity of 66.7%, specificity of 32.9%, and accuracy of 38.0% in predicting septic failure. Alpha-defensin showed sensitivity of 28.6%, specificity of 87.8%, and accuracy of 79.2%. Significant correlations included: calprotectin with PMN% (r = 0.471, p = 0.05) and alpha-defensin with WBC (r = 0.830, p < 0.01) in the successful cohort. For septic re-revisions, calprotectin and alpha-defensin were highly correlated (r = 0.969, p < 0.01). ICM correctly diagnosed persistent PJI in 26.7%, while EBJIS diagnosed 24.2%. The microbial spectrum shifted from gram-positive to gram-negative bacteria between reimplantation and re-revision surgeries. Conclusion. Synovial calprotectin and alpha-defensin demonstrated limited accuracy in ruling out persistent PJI at reimplantation. The low sensitivity of current diagnostic criteria, combined with the observed shift in microbial spectrum, underscores the challenges in diagnosing persistent PJI during 2nd stage of a two-stage revisions arthroplasty


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 73 - 73
22 Nov 2024
Erbeznik A Smrdel KS Kišek TC Cvitković-Špik V Triglav T Vodicar PM
Full Access

Aim. The aim of this study was to develop an in-house multiplex PCR real-time assay on the LightCycler 480 system (Roche, Basel, Switzerland) with the aim of rapid detection of common pathogens in prosthetic joint infections (PJI), followed by validation on clinical samples (sonication fluid and tissue biopsies) routinely collected for PJI diagnosis. Methods. Using the PrimerQuest and CLC WorkBench tool, we designed six primer sets with specific fluorescently labelled TaqMan probes for the nuc gene in different Staphylococcus species (S. aureus, S. epidermidis, S. capitis, S. lugdunensis, S. hominis, S. haemolyticus). In addition, primers previously developed by Renz et al. (2022) for C. acnes were integrated into our assay with internal control of isolation, leading to the development of specific mPCR assay with seven included targets. Analytical sensitivity and specificity were evaluated using reference bacterial strains. To determine the assay's limit of detection (LOD), we conducted serial dilutions of eluates containing known concentrations of bacterial DNA copies/µl. The overall LOD in spiked clinical samples, including sample preparation and DNA isolation on MagnaPure24, was measured through 10-fold serial dilutions (from 10. 9. to 10. -1. CFU/ml) including additional dilutions of 5000, 500, 50 and 5 CFU/ml. Results. The results with LOD in serial dilutions of eluates and spiked clinical samples, together with analytical sensitivity and specificity, are shown in Table 1. Conclusion. The mPCR assay showed excellent analytical sensitivity and specificity, but with considerably lower LOD after sample preparation and further DNA isolation in spiked clinical samples. Although still promising in diagnostics of acute infections, the use of mPCR could be challenging in chronic, low-grade infections with lower microbial burden. Nevertheless, PCR offers significant advantages in terms of speed and can shorten the time to result, especially for C. acnes infections. Additionally, it represents a promising complementary approach in patients with suspected PJI on antibiotic therapy with negative culture results. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 46 - 46
22 Nov 2024
Mozella A Leal AC Cobra H Costa G
Full Access

Aim. Evaluate the metabolites composition of the synovial fluid from patients with PJI or aseptic failure of total knee arthroplasties. Method. The synovial fluids from 21 patients scheduled for revision total knee arthroplasty (11 with the diagnosis of PJI and 10 with aseptic failures) were analyzed using 1D 1H NMR spectroscopy. Univariate and multivariate statistical analyses were used to identify metabolites that were differentially abundant between those groups. Results. A total of 28 metabolites were identified and five of them found to be differentially abundant between infected and non-infected synovial fluids. Lactate, acetate and 3-hydroxybutyrate were found to be in a higher concentration, and glucose and creatine were found reduced in the synovial fluid from PJI patients. Conclusions. Synovial fluid from patients with PJI exhibit a distinct metabolic profile, possibly reflecting metabolic adaptation that occurs in the infected periprosthetic microenvironment. Further research and studies are warranted to gain a broader insight into the metabolic pathways engaged by both pathogen and immune cells in the context of a PJI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 43 - 43
22 Nov 2024
Bekkers W Zwart V Swietoslawki A Oost IK Nijs A Emmen J Van Geenen R
Full Access

Aim. Periprosthetic joint infection (PJI) is one of the main reasons for revision surgery after primary unicompartmental knee arthroplasty (UKA), total knee arthroplasty (TKA) or total hip arthroplasty (THA). Currently the MSIS and EBJIS criteria sets are considered to be the gold standards in determining PJI. These criteria sets are complex and contain tests that are time-consuming and many are rather costly. Therefore, further research is indicated to find a simpler but equally reliable diagnostic test. In this study we evaluated the additional value of calprotectine measurement in synovial fluid in patients undergoing hip and knee (revision) arthroplasty following routine work-up. Method. In a retrospective cohort study, we analyzed 182 synovial fluid samples from 143 patients with suspected PJI after UKA, TKA, THA or revision arthroplasty. Twenty-six of those cases were classified as PJI according to the MSIS and EBJIS criteria. Subsequently, synovial calprotectin was determined, using a lateral flow assay and two cut-off thresholds of ≥14 mg/L and ≥50 mg/L. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of synovial calprotectin was determined. Results. When applying the MSIS and EBJIS criteria and a calprotectin level ≥14 mg/L, synovial calprotectin revealed an area under the curve of 0.96 (95% CI 0.90-1.00), with 92.3% sensitivity and 100% specificity. The PPV and NPV were 100% and 92.9% respectively. When applying the MSIS and EBJIS criteria and a calprotectin level ≥ 50 mg/L, synovial calprotectin revealed an area under the curve of 0.94 (95% CI 0.87-1.00), with 88.5% sensitivity and 100% specificity. The PPV and NPV were 100% and 89.7% respectively. Conclusions. The value of calprotectin in synovial fluid gives valuable information with a single test result, resulting in high predictive value in the diagnosis of PJI after hip or knee arthroplasty and should seriously be considered as part of PJI diagnostics in an outpatient clinical setting. The high specificity can help rule in patients that are suspected of PJI. Therefor this test can be helpful in a preop diagnostic work-up to avoid unnecessary revisions in patients with well-placed and well-fixed arthroplasties with a suspected PJI. These conclusions are independent of which criteria set was used as a gold standard


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 77 - 77
22 Nov 2024
Vidal LS Auñon A García AB Cañete JG Parron R Esteban-Moreno J
Full Access

Aim. To evaluate the bacterial counts of sonicatied implants in patients with osteoarticular infections. Various studies have demostrated the usefulness of sonication of retrieved implants in order to provide an accurate microbiological diagnosis. Although cutoff values for original sonicate counts have been established, the use of centrifugation may influence these values. Method. A retrospective, single-center study, including sonication fluid samples from implants removed between January 2011 and October 2023, was performed. Patients were diagnosed with implant-associated infection based on the criteria available at the time of diagnosis. Osteoarticular implants were sonicated following the protocol described by Esteban et al. Sonicated fluid was centrifuged for 20 minutes at 3000 x g, and the sediment was resuspended in 5 mL of phosphate buffer solution. Ten µl of the sample were streaked onto each medium for quantitative culture. Bacterial counts exceeding 100,000 CFU/mL were considered as 100,000 CFU/mL for statistical analysis. Results. The study included 457 sonication fluid samples. Of these, 316 samples were from patients with prosthetic joint infection (PJI), with 26.3 % diagnosed with acute PJI and 73.7 % with chronic PJI. Additionally, 141 samples were from patients with osteosynthesis infection. The median CFU/ml in the sonication fluid was 40,000 CFU/mL (IQR 1,000 CFU/mL-100,000 CFU/mL). No statistically significant difference was observed between the different types of implants (prosthesis vs. osteosynthesis, p=0.218). A trend of higher counts was noted for acute PJI compared to chronic PJI (р=0.052). Most infections were monomicrobial, but 16.2% were polymicrobial. Statistically significant higher bacterial counts were observed in polymicrobial infections compared to monomicrobial infections (р<0.005). Among monomicrobial infections, no differences were found between Gram-negative and Gram-positive microorganisms (р=0.416). No differences were also found between joints (knee vs. hip) (p=0.353). Conclusions. Significant variability was observed in the number of colonies detected in all samples, regardless of the type of implant, the number of microorganisms or the species identified. Higher counts were detected in polymicrobial infections, and a trend was also noted for higher counts in acute infections