Aims. Periprosthetic joint infections (PJIs) pose significant challenges to patients and healthcare systems worldwide. The aim of this study was to estimate the health-economic burden of reimbursement payment in Europe for PJIs following primary hip and knee arthroplasty. Methods. The calculation was based on health-economic modelling using data on primary hip and knee arthroplasties for the year 2019 from the Statistical Office of the European Union (Eurostat) and published infection rates to estimate the total number of hip and knee PJIs in 30 European countries. Revision procedures were stratified into: 1) debridement, antibiotics, and implant retention (DAIR); 2) one-stage exchange; and 3) two-stage revision procedures. The cases were then multiplied by the respective healthcare system reimbursement payments. Payment data were acquired from a survey of 13 countries (Austria, Croatia, France, Germany, Italy, Lithuania, Netherlands, Norway, Portugal, Slovenia, Switzerland, Turkey, and the UK) and extrapolated for the remaining countries. Results. In 2019, a total of 2,048,778 primary total joint replacements were performed (total hip arthroplasty (THA) = 1,147,316 and total knee arthroplasty (TKA) = 901,462), with an estimated 20,416 cases of PJIs (11,131 hip and 9,285 knee) in Europe. This results in an estimated total reimbursement burden of €346,262,026 for European healthcare systems. The breakdown for hip
Aims. The diagnosis of periprosthetic joint infection (PJI) remains a challenge, as no single diagnostic test shows high diagnostic accuracy. Recently, the measurement of synovial biomarkers has shown promising results. The aim of this study was to present a novel multiplex micro-enzyme-linked immunosorbent assay (ELISA) method for the rapid and simultaneous measurement of alpha-defensin, interleukin (IL)-6, and calprotectin developed in a model buffer system and human spiked synovial fluid. Methods. A microfluidics- and chemiluminescence-based multiplex micro-ELISA point-of-care testing system was employed for the rapid and simultaneous measurement of alpha-defensin, calprotectin, and IL-6 developed in a model buffer system and spiked human synovial fluid. Cut-off values of 1.56 µg/ml for alpha-defensin, 50 µg/ml for calprotectin, and 0.031 µg/ml for IL-6 were extracted from the literature as optimal cut-off values for the diagnosis of
Aims. The aim of this study was to examine the indications for further surgery and the characteristics of the patients within one year of medial unicompartmental knee arthroplasty (mUKA), providing an assessment of everyday clinical practice and outcomes in a high-volume country. Methods. All mUKAs which were performed between 1 April 2020 and 31 March 2021 and underwent further surgery within one year, from the Danish Knee Arthroplasty Registry (DKAR), were included. For primary procedures and reoperations, we received data on the characteristics of the patients, the indications for surgery, the type of procedure, and the sizes of the components individually, from each Danish private and public arthroplasty centre. All subsequent reoperations were recorded regardless of the time since the initial procedure. Results. A total of 2,431 primary mUKAs in 2,303 patients were reported to the DKAR during the study period and 55 patients (55 mUKAs; 2.3%; (95% CI 1.7 to 3.0)) underwent further surgery within one year. The most frequent indications for reoperation were periprosthetic fracture (n = 16; 0.7% (95% CI 0.4 to 1.1)), periprosthetic joint infection (PJI) (n = 13; 0.5% (95% CI 0.3 to 0.9)), and bearing dislocation (n = 9; 0.4% (95% CI 0.2 to 0.7)). Six periprosthetic fractures were treated with internal fixation, but five of these patients later underwent revision to a total knee arthroplasty (TKA). Ten PJIs were treated with debridement, antibiotics, and implant retention (DAIR). Due to persistent infection, four of these patients later underwent revision to a TKA. All nine bearing dislocations were treated with exchange of the liner, and seven occurred in patients who, based on their sex and height, probably had undersized femoral components. Conclusion. Reoperations are rare following mUKA in a high-volume country. The most frequent indications for further surgery were periprosthetic fracture,
Fracture-related infections (FRIs) are a major concern for patients and healthcare systems, yet their impact on mental health has been largely overlooked. This study aimed to assess the longitudinal impact of FRI on patients’ quality of life. A prospective study was conducted at a level 1 trauma centre between January 2020 and December 2022. In total, 56 patients participated, with quality of life assessed at five timepoints: one week preoperatively, and one, three, six, and 12 months postoperatively. Statistical analysis was performed using repeated measures analysis of variance (ANOVA) with adjusted post-hoc analysis.Aims
Methods
Revision hip arthroplasty for femoral stem loosening remains challenging due to significant bone loss and deformities requiring specialized revision stems. The aim of this study was to evaluate the clinical and radiological outcomes, and survival, of a consecutive series of femoral revisions performed using a primary cementless stem with tapered geometry and rectangular cross-section at medium-term follow-up. We retrospectively evaluated 113 patients (115 hips) with intraoperative Paprosky type I (n = 86) or II (n = 29) defects, who underwent femoral revision with Alloclassic Zweymüller SL stem for one-stage aseptic revision or two-stage septic revision from January 2011 to December 2020. The mean follow-up was 77.9 months (SD 33.8). Nine patients were lost to follow-up (deceased or not available), leaving 104 patients (106 hips) for the clinical and radiological analysis. Clinical assessment was performed with Harris Hip Score (HHS) and visual analogue scale (VAS) before surgery and at final follow-up.Aims
Methods
To evaluate the concurrent use of vancomycin and ε-aminocaproic acid (EACA) in primary total hip arthroplasty (THA). In total, 120 patients undergoing unilateral primary THA were divided into three groups: Group VE received intra-articular vancomycin and EACA; Group V received only intra-articular vancomycin; and Group E received only intra-articular EACA. Blood and joint fluids were sampled postoperatively to measure the vancomycin levels using chromatography. Blood loss and kidney function were monitored.Aims
Methods
Aims. The aim of this study was to assess the incidence of reinfection in patients after two-stage revision of an infected megaprosthesis (MPR) implanted after resection of a bone tumour. Methods. A retrospective study was carried out of 186 patients from 16 bone sarcoma centres treated between January 2010 and December 2020. The median age at the time of tumour diagnosis was 26 years (IQR 17 to 33); 69 (37.1%) patients were female, and 117 (62.9%) were male. Results. A total of 186 patients with chronic MPR infections were included. Median follow-up was 68 months (IQR 31 to 105). The most represented sites of MPR were distal femur in 93 cases (50.0%) and proximal tibia in 53 cases (28.5%). Polymicrobial infections were seen in 34 cases (18.3%). The most frequent isolated pathogens were staphylococci. Difficult-to-treat (DTT) pathogens were isolated in 50 cases (26.9%). The estimated infection recurrence (IR) rate was 39.1% at five years and 50.0% at ten years. A higher IR rate was found in DTT
Around the world, the emergence of robotic technology has improved surgical precision and accuracy in total knee arthroplasty (TKA). This territory-wide study compares the results of various robotic TKA (R-TKA) systems with those of conventional TKA (C-TKA) and computer-navigated TKA (N-TKA). This is a retrospective study utilizing territory-wide data from the Clinical Data Analysis and Reporting System (CDARS). All patients who underwent primary TKA in all 47 public hospitals in Hong Kong between January 2021 and December 2023 were analyzed. Primary outcomes were the percentage use of various robotic and navigation platforms. Secondary outcomes were: 1) mean length of stay (LOS); 2) 30-day emergency department (ED) attendance rate; 3) 90-day ED attendance rate; 4) 90-day reoperation rate; 5) 90-day mortality rate; and 6) surgical time.Aims
Methods
The purpose of this study was to directly compare the Modular Dual Mobility (MDM) Mobile Bearing Hip System (Stryker, USA) and large femoral heads (LFHs) in revision total hip arthroplasties (THAs) at mid-term follow-up, with specific emphasis on survival free of re-revision for dislocation, any re-revision, dislocation, and the risk of metal-related complications. We identified 299 revision THAs performed at a single tertiary care academic institution from March 2011 to July 2014. Aseptic loosening of the acetabular component (n = 65), dislocation (n = 58), and reimplantation as part of a two-stage exchange protocol (n = 57) were the most common reasons for index revision. MDM constructs were used in 123 cases, and LFHs were used in 176 cases. Mean age was 66 years (28 to 93), mean BMI was 31 kg/m2 (18 to 55), and 45% (n = 136) were female. Mean follow-up was seven years (2 to 12).Aims
Methods
Approximately 10% to 20% of knee arthroplasty patients are not satisfied with the result, while a clear indication for revision surgery might not be present. Therapeutic options for these patients, who often lack adequate quadriceps strength, are limited. Therefore, the primary aim of this study was to evaluate the clinical effect of a novel rehabilitation protocol that combines low-load resistance training (LL-RT) with blood flow restriction (BFR). Between May 2022 and March 2024, we enrolled 45 dissatisfied knee arthroplasty patients who lacked any clear indication for revision to this prospective cohort study. All patients were at least six months post-surgery and had undergone conventional physiotherapy previously. The patients participated in a supervised LL-RT combined with BFR in 18 sessions. Primary assessments included the following patient-reported outcome measures (PROMs): Knee injury and Osteoarthritis Outcome Score (KOOS); Knee Society Score: satisfaction (KSSs); the EuroQol five-dimension five-level questionnaire (EQ-5D-5L); and the pain catastrophizing scale (PCS). Functionality was assessed using the six-minute walk Test (6MWT) and the 30-second chair stand test (30CST). Follow-up timepoints were at baseline, six weeks, three months, and six months after the start.Aims
Methods
The December 2024 Research Roundup360 looks at: Skeletal muscle composition, power, and mitochondrial energetics in older men and women with knee osteoarthritis; Machine-learning models to predict osteonecrosis in patients with femoral neck fractures undergoing internal fixation; Aetiology of patient dissatisfaction following primary total knee arthroplasty in the era of robotic-assisted technology; Efficacy and safety of commonly used thromboprophylaxis agents following hip and knee arthroplasty; The COVID-19 effect continues; Nickel allergy in knee arthroplasty: does self-reported sensitivity affect outcomes?; Tranexamic acid use and joint infection risk in total hip and knee arthroplasty.
Aims. Cutibacterium acnes (C. acnes; previously known as Propionibacterium acnes or P. acnes) periprosthetic hip and knee infections are under-reported. While culture contamination with C. acnes occurs, true infections are important to recognize and treat. We sought to describe the demographics and treatment outcomes of patients with C. acnes periprosthetic joint infections (PJIs) of the hip and knee. Methods. Patients with C. acnes
Electromagnetic induction heating has demonstrated in vitro antibacterial efficacy over biofilms on metallic biomaterials, although no in vivo studies have been published. Assessment of side effects, including thermal necrosis of adjacent tissue, would determine transferability into clinical practice. Our goal was to assess bone necrosis and antibacterial efficacy of induction heating on biofilm-infected implants in an in vivo setting. Titanium-aluminium-vanadium (Ti6Al4V) screws were implanted in medial condyle of New Zealand giant rabbit knee. Study intervention consisted of induction heating of the screw head up to 70°C for 3.5 minutes after implantation using a portable device. Both knees were implanted, and induction heating was applied unilaterally keeping contralateral knee as paired control. Sterile screws were implanted in six rabbits, while the other six received screws coated with Aims
Methods
Periprosthetic joint infection (PJI) represents a complex challenge in orthopaedic surgery associated with substantial morbidity and healthcare expenditures. The debridement, antibiotics, and implant retention (DAIR) protocol is a viable treatment, offering several advantages over exchange arthroplasty. With the evolution of treatment strategies, considerable efforts have been directed towards enhancing the efficacy of DAIR, including the development of a phased debridement protocol for acute
Aim. Treatment of prosthetic joint infection (PJI) by systemic administration of high doses of long-term antibiotics often proves ineffective, causing severe side effects. Thus, we presented the phage Sb-1, which coding extracellular polymeric substances (EPS) degradation depolymerases, conjugated with rifampicin-loaded liposomes (Lip-RIF@Phage) by bio-orthogonal functionalization strategy to target biofilm (Figure1). Method. Methicillin-resistant Staphylococcus aureus (MRSA) biofilm was grown on porous glass beads for 24 h in vitro. After the biofilm formation, beads were exposed to 0.9% saline, then sonication. Quantitative and qualitative biofilm analyses were performed by colony counting, scanning electron microscopy and isothermal microcalorimetry. A rat model of total knee arthroplasty infected with the bioluminescent MRSA strain was developed as the
Aim. Antimicrobial peptides occur naturally in our intrinsic immune system. PLG0206 is a novel, engineered, 24-amino acid peptide which has broad-spectrum antimicrobial activity, including in biofilm and against multi-drug resistant pathogens (1,2). This is the first clinical study to evaluate the safety and tolerability of PLG0206 when administered via an irrigation solution in patients with periprosthetic joint infections (PJI) following total knee arthroplasty (TKA) during debridement, antibiotics, and implant retention (DAIR). Secondary objectives were to evaluate pharmacokinetics (PK), biomarkers and initial clinical efficacy at one year post-DAIR procedure. Method. This prospective, multicenter, open-label, interventional study assessed two dose levels of PLG0206. Fourteen patients underwent revision for
Aim. Two types of national registers surveil infections after primary total hip arthroplasty (THA) in Norway: The National surveillance system for surgical site infections (NOIS) that surveil all primary THAs 30 days postoperatively for surgical site infections (SSI), and the Norwegian Arthroplasty Register (NAR) that follow all THAs until any surgical reoperation/revision or the death of the patient. Since these registers report on the same THAs we assessed correspondence between and time trends for the two registers in period 2013 to 2022. All reported THAs were included. Method. The THAs were matched on a group level according to sex, age and ASA-class. In addition to descriptive statistics, adjusted Cox regression analyses were performed with adjustment for sex, age group (<45, 45-54, 55-64, 65-74, 75-84, >85 years) and ASA-class (1, 2, 3, 4 and missing). Changes in annual incidence and adjusted hazard rate (aHR) was calculated. Endpoints in the NOIS were 30-Days SSI and 30-Days reoperation for SSI. Endpoints in the NAR were 30-Days and 1-Year reoperation for periprosthetic joint infection (PJI). Results. The NOIS had registered 87,923 THAs with 1,393 (1.58%) SSIs and 765 (0.87%) reoperations for SSI within 30 postoperatively. The NAR had registered 91,194 THAs with 725 (0.80%) reoperations for infection after 30 days, and 1,019 (1.21%) reoperations for infections after one year. The distribution of sex, age and ASA-class was near identical in the two registers. There was a mean annual reduction in risk of both SSI (aHR 0.92 (95% CI 0.90-0.93)) and reoperation for SSI (0.95(0.92-0.97)) and
Aim. Evaluate the metabolites composition of the synovial fluid from patients with
Aim. The aim of this study was to develop an in-house multiplex PCR real-time assay on the LightCycler 480 system (Roche, Basel, Switzerland) with the aim of rapid detection of common pathogens in prosthetic joint infections (PJI), followed by validation on clinical samples (sonication fluid and tissue biopsies) routinely collected for