The aim of this study was to investigate the distribution of phenotypes in Asian patients with end-stage osteoarthritis (OA) and assess whether the phenotype affected the clinical outcome and survival of mechanically aligned total knee arthroplasty (TKA). We also compared the survival of the group in which the phenotype unintentionally remained unchanged with those in which it was corrected to neutral. The study involved 945 TKAs, which were performed in 641 patients with primary OA, between January 2000 and January 2009. These were classified into 12 phenotypes based on the combined assessment of four categories of the arithmetic hip-knee-ankle angle and three categories of actual joint line obliquity. The rates of survival were analyzed using Kaplan-Meier methods and the log-rank test. The Hospital for Special Surgery score and survival of each phenotype were compared with those of the reference phenotype with neutral alignment and a parallel joint line. We also compared long-term survival between the unchanged phenotype group and the corrected to neutral alignment-parallel joint line group in patients with Type IV-b (mild to moderate varus alignment-parallel joint line) phenotype.Aims
Methods
A substantial fraction of patients undergoing knee arthroplasty (KA) or hip arthroplasty (HA) do not achieve an improvement as high as the minimal clinically important difference (MCID), i.e. do not achieve a meaningful improvement. Using three patient-reported outcome measures (PROMs), our aim was: 1) to assess machine learning (ML), the simple pre-surgery PROM score, and logistic-regression (LR)-derived performance in their prediction of whether patients undergoing HA or KA achieve an improvement as high or higher than a calculated MCID; and 2) to test whether ML is able to outperform LR or pre-surgery PROM scores in predictive performance. MCIDs were derived using the change difference method in a sample of 1,843 HA and 1,546 KA patients. An artificial neural network, a gradient boosting machine, least absolute shrinkage and selection operator (LASSO) regression, ridge regression, elastic net, random forest, LR, and pre-surgery PROM scores were applied to predict MCID for the following PROMs: EuroQol five-dimension, five-level questionnaire (EQ-5D-5L), EQ visual analogue scale (EQ-VAS), Hip disability and Osteoarthritis Outcome Score-Physical Function Short-form (HOOS-PS), and Knee injury and Osteoarthritis Outcome Score-Physical Function Short-form (KOOS-PS).Aims
Methods
This is a multicentre, prospective assessment of a proportion of the overall orthopaedic trauma caseload of the UK. It investigates theatre capacity, cancellations, and time to surgery in a group of hospitals that is representative of the wider population. It identifies barriers to effective practice and will inform system improvements. Data capture was by collaborative approach. Patients undergoing procedures from 22 August 2022 and operated on before 31 October 2022 were included. Arm one captured weekly caseload and theatre capacity. Arm two concerned patient and injury demographics, and time to surgery for specific injury groups.Aims
Methods
BoneMaster is a thin electrochemically applied hydroxyapatite (HA) coating for orthopaedic implants that is quickly resorbed during osseointegration. Early stabilization is a surrogacy marker of good survival of femoral stems. The hypothesis of this study was that a BoneMaster coating yields a fast early and lasting fixation of stems. A total of 53 patients were randomized to be treated using Bi-Metric cementless femoral stems with either only a porous titanium plasma-sprayed coating (P group) or a porous titanium plasma-sprayed coating with an additional BoneMaster coating (PBM group). The patients were examined with radiostereometry until five years after surgery.Aims
Methods
We aimed to compare the implant survival, complications, readmissions, and mortality of Vancouver B2 periprosthetic femoral fractures (PFFs) treated with internal fixation with that of B1 PFFs treated with internal fixation and B2 fractures treated with revision arthroplasty. We retrospectively reviewed the data of 112 PFFs, of which 47 (42%) B1 and 27 (24%) B2 PFFs were treated with internal fixation, whereas 38 (34%) B2 fractures underwent revision arthroplasty. Decision to perform internal fixation for B2 PFFs was based on specific radiological (polished femoral components, intact bone-cement interface) and clinical criteria (low-demand patient). Median follow-up was 36.4 months (24 to 60). Implant survival and mortality over time were estimated with the Kaplan-Meier method. Adverse events (measured with a modified Dindo-Clavien classification) and 90-day readmissions were additionally compared between groups.Aims
Methods
Time to treatment initiation (TTI) is generally defined as the time from the histological diagnosis of malignancy to the initiation of first definitive treatment. There is no consensus on the impact of TTI on the overall survival in patients with a soft-tissue sarcoma. The purpose of this study was to determine if an increased TTI is associated with overall survival in patients with a soft-tissue sarcoma, and to identify the factors associated with a prolonged TTI. We identified 23,786 patients from the National Cancer Database who had undergone definitive surgery between 2004 and 2015 for a localized high-grade soft-tissue sarcoma of the limbs or trunk. A Cox proportional hazards model was used to examine the relationship between a number of factors and overall survival. We calculated the incidence rate ratio (IRR) using negative binomial regression models to identify the factors that affected TTI.Aims
Methods
Malreduction of the syndesmosis has been reported in up to 52% of patients after fixation of ankle fractures. Multiple radiological parameters are used to define malreduction; there has been limited investigation of the accuracy of these measurements in differentiating malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Three observers reviewed 213 bilateral lower limb CT scans of uninjured ankles. Multiple measurements were recorded on the axial CT 1 cm above the plafond: anterior syndesmotic distance; posterior syndesmotic distance; central syndesmotic distance; fibular rotation; and sagittal fibular translation. Previously studied malreduction standards were evaluated on bilateral CT, including differences in: anterior, central and posterior syndesmotic distance; mean syndesmotic distance; fibular rotation; sagittal translational distance; and syndesmotic area. Unilateral CT was used to compare the anterior to posterior syndesmotic distances.Aims
Methods
Functional rehabilitation has become an increasingly popular treatment for Achilles tendon rupture (ATR), providing comparably low re-rupture rates to surgery, while avoiding risks of surgical complications. Limited evidence exists on whether gap size should affect patient selection for this treatment option. The aim of this study was to assess if size of gap between ruptured tendon ends affects patient-reported outcome following ATR treated with functional rehabilitation. Analysis of prospectively collected data on all 131 patients diagnosed with ATR at Royal Berkshire Hospital, UK, from August 2016 to January 2019 and managed non-operatively was performed. Diagnosis was confirmed on all patients by dynamic ultrasound scanning and gap size measured with ankle in full plantarflexion. Functional rehabilitation using an established protocol was the preferred treatment. All non-operatively treated patients with completed Achilles Tendon Rupture Scores (ATRS) at a minimum of 12 months following injury were included.Aims
Methods
The use of frozen tumour-bearing autograft combined with a vascularized fibular graft (VFG) represents a new technique for biological reconstruction of massive bone defect. We have compared the clinical outcomes between this technique and Capanna reconstruction. From June 2011 to January 2016 a retrospective study was carried out of patients with primary osteosarcoma of lower limbs who underwent combined biological intercalary reconstruction. Patients were categorized into two groups based on the reconstructive technique: frozen tumour-bearing autograft combined with concurrent VFG (Group 1) and the Capanna method (Group 2). Demographics, operating procedures, oncological outcomes, graft union, limb function, and postoperative complications were compared.Aims
Methods
The aim of this study was to determine the risk of local recurrence and survival in patients with osteosarcoma based on the proximity of the tumour to the major vessels. A total of 226 patients with high-grade non-metastatic osteosarcoma in the limbs were investigated. Median age at diagnosis was 15 years (4 to 67) with the ratio of male to female patients being 1.5:1. The most common site of the tumour was the femur (n = 103) followed by tibia (n = 66). The vascular proximity was categorized based on the preoperative MRI after neoadjuvant chemotherapy into four types: type 1 > 5 mm; type 2 ≤ 5 mm, > 0 mm; type 3 attached; type 4 surrounded.Aims
Patients and Methods
Meropenem may be an important drug in the treatment of open tibial fractures and chronic osteomyelitis. Therefore, the objective of this study was to describe meropenem pharmacokinetics in plasma, subcutaneous adipose tissue (SCT), and cancellous bone using microdialysis in a porcine model. Six female pigs were assigned to receive 1000 mg of meropenem intravenously over five minutes. Measurements of meropenem were obtained from plasma, SCT, and cancellous bone for eight hours thereafter. Microdialysis was applied for sampling in solid tissues. The meropenem concentrations were determined using ultra-high-performance liquid chromatography.Objectives
Methods
Introduction. In total knee arthroplasty, the aim is to relieve pain and provide a stable, functional knee. Sagittal stability is crucial in enabling a patient to return to functional activities. Knee implants with a medial pivot (MP) design are thought to more accurately reproduce the mechanics of the native joint, and potentially confer greater antero-posterior stability through the range of flexion than some other implant designs. Aim. This study aims to compare the sagittal stability of four different total knee arthroplasty implant designs.
Introduction. Although weight-bearing CT of the foot definitely reflects the morphology and deformity of joint, it is hard to obtain the standing CT due to difficulty of availability. Although 3D imaging reconstruction using radiographs has been reported in other joints, there is no study about foot joint. The purpose of this study is to develop a semi-automatic method based on a deformable surface fitting for achieving the weight-bearing 3D model reconstruction from standing radiographs for foot. Methods. Our method is based on a Laplacian surface deformation framework using a template model of foot. As pre- processing step, we obtained template surface meshes having the average shapes of foot bones (talus, calcaneus) from standing CT images (Planmed Verity) in 10 normal volunteers. In the reconstruction step, the surface meshes are deformed following guided user inputs with geometric constraints to recover the target shapes of 30 patients while preserving average bone shape and smoothness. Finally, we compared reconstructed 3D model to original standing CT images. Analysis was performed using Dice coefficients, average shape distance, maximal shape distance. Results. The obtained reconstruction model is close to the actual standing foot geometry (Dice coefficients 0.89, average shape distance 0.88 mm, maximum shape distance 6.33 mm). We present the accuracy and robustness of our
Introduction. Total hip arthroplasty (THA) is a commonly performed surgical procedure for the treatment of hip arthritis. Approximately 50,000 THAs are performed annually in Canada. The costs incurred to the healthcare system are tremendous, amounting to anywhere between 4.3 and 7.3 billion dollars each year. Despite the substantial financial burden of THA to the Canadian healthcare system, few studies have provided accurate cost estimations of this procedure. Purpose. To determine the impact of surgical approach on costs of THA from a hospital perspective, and provide an updated cost estimation of THA within a publically funded healthcare system. Methods. We recruited patients undergoing a THA through an anterior, posterior, or lateral approach for study participation. A single surgeon was designated to perform every case using the surgical approach of their expertise. Each patient received standardized implants: a collared, hydroxyapatite-coated, cementless femoral stem (Corail TM stem, DePuy Orthopaedics Inc., Warsaw, IN), a cementless acetabular cup (Pinnacle Sector II TM acetabular cup, DePuy Orthopaedics Inc., Warsaw, IN), a highly cross-linked polyethylene liner (AltrX TM polyethylene liner, DePuy Orthopaedics Inc., Warsaw, IN), and a cobalt chrome femoral head (Articul/eze TMcobalt chrome, DePuy Orthopaedics Inc., Warsaw, IN). We prospectively recorded costs of operating room time, length of stay in hospital, and medical and surgical interventions using a micro-costing
Representative pre-clinical analysis is essential to ensure that novel prosthesis concepts offer an improvement over the state-of-the-art. Proposed designs must, fundamentally, be assessed against cyclic loads representing common daily activities [Bergmann 2001] to ensure that they will withstand conceivable in-vivo loading conditions. Fatigue assessment involves:. –. cyclic mechanical testing, representing worst-case peak loads encountered in-vivo, typically for 10 million cycles, or. –. prediction of peak fatigue stresses using Finite Element (FE)
Objective. Sarcomas are a rare group of tumours, which pose numerous problems regarding correct diagnosis and appropriate management. This study aimed to examine whether symptom duration and tumour size at diagnosis have changed over time, using size and symptom duration as
Surgeons performing hip resurfacing ante-vert and translate the femoral component anterior to maximize head/neck offset and educe impingement. The anterior femoral neck is under tensile forces during gait similarly to the superior neck [6]. This study was esigned to determine the risk of femoral neck fracture after anterior or posterior notching of the femoral neck. Method: Fortyseven 4th generation synthetic femora were implanted with Birmingham Hip Resurfacing pros-theses (Smith &
Nephew Inc. emphis, USA). Implant preparation was performed using imageless computer navigation (VectorVision SR 1.0, BrainLAB, Grmany). The virtual prosthesis was initially planned for neutral version and translated anterior, or posterior, to create the notch. The femora were fixed in a single-leg stance and tested with axial compression using a mechanical testing machine. This
Purpose: Surgeons performing hip resurfacing antevert and translate the femoral component anteriorly to maximize head/neck offset and reduce impingement. The anterior femoral neck is under tensile forces during gait similarly to the superior neck [6]. This study was designed to determine the risk of femoral neck fracture after anterior or posterior notching of the femoral neck. Method: Forty seven fourth generation synthetic femora were implanted with Birmingham Hip Resurfacing prostheses (Smith &
Nephew Inc. Memphis, USA). Implant preparation was performed using imageless computer navigation (VectorVision SR 1.0, BrainLAB, Germany). The prosthesis was initially planned for neutral version and translated anterior, or posterior, to create a femoral neck notch. The femora were fixed in a single-leg stance and tested with axial compression using a mechanical testing machine. This
We biomechanically investigated whether the standard dynamic hip screw (DHS) or the DHS blade achieves better fixation in bone with regard to resistance to pushout, pullout and torsional stability. The experiments were undertaken in an artificial bone substrate in the form of polyurethane foam blocks with predefined mechanical properties. Pushout tests were also repeated in cadaveric femoral heads. The results showed that the DHS blade outperformed the DHS with regard to the two most important characteristics of implant fixation, namely resistance to pushout and rotational stability. We concluded that the DHS blade was the superior implant in this study.