The August 2024 Oncology Roundup360 looks at: What factors are associated with osteoarthritis after cementation for benign aggressive bone tumour of the knee joint: a systematic review and meta-analysis; Recycled bone grafts treated with extracorporeal irradiation or liquid nitrogen freezing after malignant tumour resection; Intercalary resection of the tibia for primary bone tumours: are vascularized fibula autografts with or without allografts a durable reconstruction?; 3D-printed modular prostheses for the reconstruction of intercalary bone defects after joint-sparing limb salvage surgery for femoral diaphyseal tumours; Factors influencing the outcome of patients with primary Ewing’s sarcoma of the sacrum; The significance of surveillance imaging in children with Ewing’s sarcoma and osteosarcoma; Resection margin and soft-tissue sarcomas of the extremities treated with limb-sparing surgery and postoperative radiotherapy.
Brachial plexus injury (BPI) is an often devastating injury that affects patients physically and emotionally. The vast majority of the published literature is based on surgeon-graded assessment of motor outcomes, but the patient experience after BPI is not well understood. Our aim was to better understand overall life satisfaction after BPI, with the goal of identifying areas that can be addressed in future delivery of care. We conducted semi-structured interviews with 15 BPI patients after initial nerve reconstruction. The interview guide was focused on the patient’s experience after BPI, beginning with the injury itself and extending beyond surgical reconstruction. Inductive and deductive thematic analysis was used according to standard qualitative methodology to better understand overall life satisfaction after BPI, contributors to life satisfaction, and opportunities for improvement.Aims
Methods
Aims. We analyzed the long-term outcomes of patients observed over ten years after resection en bloc and reconstruction with extracorporeal irradiated autografts. Patients and Methods. This retrospective study included 27 patients who underwent resection en bloc and reimplantation of an extracorporeal irradiated autograft. The mean patient age and follow-up period were 31.7 years (9 to 59) and 16.6 years (10.3 to 24.3), respectively. The most common diagnosis was osteosarcoma (n = 10), followed by chondrosarcoma (n = 6). The femur (n = 13) was the most frequently involved site, followed by the tibia (n = 7). There were inlay grafts in five patients,
After intercalary resection of a bone tumour from the femur,
reconstruction with a vascularized fibular graft (VFG) and massive
allograft is considered a reliable method of treatment. However,
little is known about the long-term outcome of this procedure. The
aims of this study were to determine whether the morbidity of this
procedure was comparable to that of other reconstructive techniques,
if it was possible to achieve a satisfactory functional result, and
whether biological reconstruction with a VFG and massive allograft
could achieve a durable, long-lasting reconstruction. A total of 23 patients with a mean age of 16 years (five to 40)
who had undergone resection of an intercalary bone tumour of the
femur and reconstruction with a VFG and allograft were reviewed
clinically and radiologically. The mean follow-up was 141 months
(24 to 313). The mean length of the fibular graft was 18 cm (12 to
29). Full weight-bearing without a brace was allowed after a mean
of 13 months (seven to 26).Aims
Patients and Methods
Aims. The aims of this study were to analyse the long-term outcome
of vascularised fibular graft (VFG) reconstruction after tumour
resection and to evaluate the usefulness of the method. . Patients and Methods. We retrospectively reviewed 49 patients who had undergone resection
of a sarcoma and reconstruction using a VFG between 1988 and 2015.
Their mean follow-up was 98 months (5 to 317). Reconstruction was
with an osteochondral graft (n = 13),
Vascularised fibular grafts (VFGs ) are a valuable
surgical technique in limb salvage after resection of a tumour.
The primary objective of this multicentre study was to assess the
risk factors for failure and complications for using a VFG after
resection of a tumour. The study involved 74 consecutive patients (45 men and 29 women
with mean age of 23 years (1 to 64) from four tertiary centres for
orthopaedic oncology who underwent reconstruction using a VFG after
resection of a tumour between 1996 and 2011. There were 52 primary
and 22 secondary reconstructions. The mean follow-up was 77 months
(10 to 195). In all, 69 patients (93%) had successful limb salvage; all of
these united and 65 (88%) showed hypertrophy of the graft. The mean
time to union differed between those involving the upper (28 weeks;
12 to 96) and lower limbs (44 weeks; 12 to 250). Fracture occurred
in 11 (15%), and nonunion in 14 (19%) patients. In 35 patients (47%) at least one complication arose, with a
greater proportion in lower limb reconstructions, non-bridging osteosynthesis,
and in children. These complications resulted in revision surgery
in 26 patients (35%). VFG is a successful and durable technique for reconstruction
of a defect in bone after resection of a tumour, but is accompanied
by a significant risk of complications, that often require revision
surgery. Union was not markedly influenced by the need for chemo-
or radiotherapy, but should not be expected during chemotherapy.
Therefore, restricted weight-bearing within this period is advocated. Cite this article:
The June 2015 Oncology Roundup360 looks at: Infection in megaprosthesis; Impressive results for mid femoral reconstruction; Revered teaching or old myth? Femoral neck protection in metastatic disease; Megaprosthesis about the knee; Malignant transformation in multiple hereditary exostoses; Fracture of intercalary bone allograft; Comorbidity and outcomes in sarcoma; A worrying turn? Use of denosumab for giant cell tumour of bone
The October 2014 Oncology Roundup360 looks at: how best to reconstruct humeral tumours; not everything is better via the arthroscope; obesity and sarcoma; frozen autograft;
In 1999, we developed a technique for biological
reconstruction after excision of a bone tumour, which involved using
autografts of the bone containing the tumour treated with liquid
nitrogen. We have previously reported the use of this technique
in 28 patients at a mean follow up of 27 months (10 to 54). In this study, we included 72 patients who underwent reconstruction
using this technique. A total of 33 patients died and three were
lost to follow-up, at a mean of 23 months (2 to 56) post-operatively,
leaving 36 patients available for a assessment at a mean of 101
months 16 to 163) post-operatively. The methods of reconstruction included
an osteo-articular graft in 16, an intercalary in 13 and, a composite
graft with prosthesis in seven. Post-operative function was excellent in 26 patients (72.2%),
good in seven (19.4%), and fair in three (8.3%) according to the
functional evaluation system of Enneking. No recurrent tumour occurred
within the grafts. The autografts survived in 29 patients (80.6%),
and the rates of survival at five and ten years were 86.1% and 80.6
%, respectively. Seven of 16 osteo-articular grafts (44%) failed
because of fracture or infection, but all the composite and intercalary
grafts survived. The long-term outcomes of frozen autografting, particularly using
composite and
The December 2012 Research Roundup360 looks at: whether the rheumatoid factor is just a ‘quick test’; osteonecrosis in smokers; pasteurisation effect on bone reconstruction; venous thromboembolism risk in rheumatoids; whether stem cells reverse age-related osteopenia; the effect of running on rat knees; rapid fracture healing in rats with ultrasound; magnetic stem cells; and the safety of surgery.
We carried out a retrospective study to assess the clinical results of lengthening the fourth metatarsal in brachymetatarsia in 153 feet of 106 patients (100 female, six males) using three different surgical techniques. In one group lengthening was performed by one-stage intercalary bone grafting secured by an intramedullary Kirschner-wire (45 feet, 35 patients). In the second group lengthening was obtained gradually using a mini-external fixator after performing an osteotomy with a saw (59 feet, 39 patients) and in the third group lengthening was achieved in a gradual manner using a mini-external fixator after undertaking an osteotomy using osteotome through pre-drilled holes (49 feet, 32 patients). The mean age of the patients was 26.3 years (13 to 48). Pre-operatively, the fourth ray of the bone-graft group was longer than that of other two groups (p <
0.000). The clinical outcome was compared in the three groups. The mean follow-up was 22 months (7 to 55). At final follow-up, the mean lengthening in the bone-graft group was 13.9 mm (3.5 to 23.0, 27.1%) which was less than that obtained in the saw group with a mean of 17.8 mm (7.0 to 33.0, 29.9%) and in the pre-drilled osteotome group with a mean of 16.8 mm (6.5 to 28.0, 29.4%, p = 0.001). However, the mean time required for retention of the fixation in the bone-graft group was the shortest of the three groups. Patients were dissatisfied with the result for five feet (11.1%) in the bone-graft group, eight (13.6%) in the saw group and none in the pre-drilled osteotomy group (p <
0.000). The saw group included eight feet with failure of bone formation after surgery. Additional operations were performed in 20 feet because of stiffness (n = 7, all groups), failure of bone formation (n = 4, saw group), skin maceration (n = 4, bone-graft group), malunion (n = 4, bone-graft and saw groups) and breakage of the external fixator (n = 1, saw group). We conclude that the gradual lengthening by distraction osteogenesis after osteotomy using an osteotome produces the most reliable results for the treatment of fourth brachymetatarsia.
This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve fixation, was cemented into the medullary canal. The proximal end had hydroxyapatite-coated extracortical plates which were secured to the remaining proximal tibial metaphysis using cortical screws. The mean age of the patients at operation was 28.9 years (8 to 43) and the mean follow-up was for 35 months (4 to 48). The mean Musculoskeletal Tumour Society score was 79% (57% to 90%), the mean Oxford Knee score was 40 points of 48 (36 to 46) and the mean knee flexion was 112° (100° to 120°). In one patient, revision to a below-knee amputation through the prosthesis was required because of recurrence of the tumour. Another patient sustained a periprosthetic fracture which healed with a painful malunion. This was revised to a further endoprosthesis which replaced the knee. In the remaining six patients the prosthesis allowed preservation of the knee joint with good function and no early evidence of loosening. Further follow-up is required to assess the longevity of these prostheses.
The authors offer their personal experience with long term results on 71 patients (72 allografts) operated between 1961 and 1990. 23 were large osteoarticular
Purpose: To describe our experience with vascularised fibulas used in sarcoma limb salvage surgery using standardized patient outcome measures. Methods: All vascularised fibulas and osteochondral allografts performed in the Capital District Health authority were assessed. A complete chart review and current functional assessment of the patients using the Toronto Extremity Salvage score (TESS) and the Musculosketal Tumour Society (MSTS) score were performed. Results: Nineteen patients with 19 tumors were recorded. The tumors range from 11 osteosarcomas, 4 Ewing’s sarcoma, 3 Malignant Fibrous Histiocytoma’s and 1 Chondrosarcoma. Average age was 23. The patient demographics are 75% male, 42% smokers, 86% femoral lesions and 13 % presented with pathological fracture. There were 9 hip fusions, 3 knee fusions, 6
We describe a method of reconstruction using tumour-bearing autograft treated by liquid nitrogen in 28 patients. The operative technique consisted of The limb function was rated as excellent in 20 patients (71.4%), good in three (10.7%), fair in three (10.7%), and poor in two (7.1%). At the final follow-up six patients had died at a mean of 19.8 months after the operation, while 21 remained free from disease with a mean follow-up of 28.1 months (10 to 54). One patient is alive with disease. Bony union was seen at a mean of 6.7 months after the operation in 26 patients. Complications were encountered in seven patients, including three deep infections, two fractures, and two local recurrences. All were managed successfully. Our results suggest that this is a simple and effective method of biological reconstruction.