Husum H Hellfritzsch MB Maimburg RD Møller-Madsen B Henriksen M Lapitskaya N Kold S Rahbek O

Aims

To establish cut-off values for lateral pubofemoral distance (PFD) measurements for detecting hip dysplasia in early (four days) and standard care (six weeks) screening for developmental dysplasia of the hip (DDH).

Methods

All newborns, during a one-year period (October 2021 to October 2022), were offered a PFD ultrasound (US) examination in addition to the existing screening programme for DDH. Newborns who were referred for standard care hip US, suspected for DDH, received a secondary PFD US examination in conjunction with the standard care Graf/Harcke hip US examination. Receiver operating characteristic curves and empirically optimal cut-off values were calculated with a true positive defined as a Graf type ≥ IIc hip.


The Bone & Joint Journal
Vol. 107-B, Issue 2 | Pages 261 - 267
1 Feb 2025
Theunissen WWES van der Steen MC Klerkx T Schonck C Besselaar AT van Douveren FQMP Tolk JJ

Aims

Worldwide controversy exists on the optimal treatment of stable dysplastic hips. The most common treatment options are abduction brace treatment and active surveillance. The primary aim of this study was to assess the effect of active surveillance in stable hip dysplasia, by investigating the percentage of Graf IIb stable dysplastic hips that recover spontaneously without abduction brace treatment. The second aim was to identify prognostic factors for spontaneous recovery of stable dysplastic hips.

Methods

A single-centre, prospective cohort study was conducted at the Máxima Medical Center between 1 March 2019 and 1 March 2023. Infants aged three to 4.5 months at the first outpatient clinic visit, diagnosed with Graf IIb hip dysplasia, and treated with active surveillance were included. Spontaneous recovery was defined as infants who had a normalized hip on ultrasound (α-angle ≥ 60°) after six weeks of active surveillance without receiving abduction brace treatment. Baseline infant characteristics and ultrasound measurements were used as potential predictor variables for spontaneous recovery in logistic regression analyses.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 3 - 8
2 Jan 2024
Husum H Hellfritzsch MB Maimburg RD Møller-Madsen B Henriksen M Lapitskaya N Kold S Rahbek O

Aims

The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%.

Methods

We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired t-test, and box-plots.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1123 - 1130
1 Oct 2023
Donnan M Anderson N Hoq M Donnan L

Aims. The aim of this study was to investigate the agreement in interpretation of the quality of the paediatric hip ultrasound examination, the reliability of geometric and morphological assessment, and the relationship between these measurements. Methods. Four investigators evaluated 60 hip ultrasounds and assessed their quality based the standard plane of Graf et al. They measured geometric parameters, described the morphology of the hip, and assigned the Graf grade of dysplasia. They analyzed one self-selected image and one randomly selected image from the ultrasound series, and repeated the process four weeks later. The intra- and interobserver agreement, and correlations between various parameters were analyzed. Results. In the assessment of quality, there a was moderate to substantial intraobserver agreement for each element investigated, but interobserver agreement was poor. Morphological features showed weak to moderate agreement across all parameters but improved to significant when responses were reduced. The geometric measurements showed nearly perfect agreement, and the relationship between them and the morphological features showed a dose response across all parameters with moderate to substantial correlations. There were strong correlations between geometric measurements. The Graf classification showed a fair to moderate interobserver agreement, and moderate to substantial intraobserver agreement. Conclusion. This investigation into the reliability of the interpretation of hip ultrasound scans identified the difficulties in defining what is a high-quality ultrasound. We confirmed that geometric measurements are reliably interpreted and may be useful as a further measurement of quality. Morphological features are generally poorly interpreted, but a simpler binary classification considerably improves agreement. As there is a clear dose response relationship between geometric and morphological measurements, the importance of morphology in the diagnosis of hip dysplasia should be questioned. Cite this article: Bone Joint J 2023;105-B(10):1123–1130


Bone & Joint 360
Vol. 12, Issue 5 | Pages 42 - 45
1 Oct 2023

The October 2023 Children’s orthopaedics Roundup360 looks at: Outcomes of open reduction in children with developmental hip dislocation: a multicentre experience over a decade; A torn discoid lateral meniscus impacts lower-limb alignment regardless of age; Who benefits from allowing the physis to grow in slipped capital femoral epiphysis?; Consensus guidelines on the management of musculoskeletal infection affecting children in the UK; Diagnosis of developmental dysplasia of the hip by ultrasound imaging using deep learning; Outcomes at a mean of 13 years after proximal humeral fracture during adolescence; Clubfeet treated according to Ponseti at four years; Controlled ankle movement boot provides improved outcomes with lower complications than short leg walking cast.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 635 - 642
23 Aug 2023
Poacher AT Hathaway I Crook DL Froud JLJ Scourfield L James C Horner M Carpenter EC

Aims

Developmental dysplasia of the hip (DDH) can be managed effectively with non-surgical interventions when diagnosed early. However, the likelihood of surgical intervention increases with a late presentation. Therefore, an effective screening programme is essential to prevent late diagnosis and reduce surgical morbidity in the population.

Methods

We conducted a systematic review and meta-analysis of the epidemiological literature from the last 25 years in the UK. Articles were selected from databases searches using MEDLINE, EMBASE, OVID, and Cochrane; 13 papers met the inclusion criteria.


Bone & Joint Open
Vol. 4, Issue 4 | Pages 234 - 240
3 Apr 2023
Poacher AT Froud JLJ Caterson J Crook DL Ramage G Marsh L Poacher G Carpenter EC

Aims. Early detection of developmental dysplasia of the hip (DDH) is associated with improved outcomes of conservative treatment. Therefore, we aimed to evaluate a novel screening programme that included both the primary risk factors of breech presentation and family history, and the secondary risk factors of oligohydramnios and foot deformities. Methods. A five-year prospective registry study investigating every live birth in the study’s catchment area (n = 27,731), all of whom underwent screening for risk factors and examination at the newborn and six- to eight-week neonatal examination and review. DDH was diagnosed using ultrasonography and the Graf classification system, defined as grade IIb or above or rapidly regressing IIa disease (≥4. o. at four weeks follow-up). Multivariate odds ratios were calculated to establish significant association, and risk differences were calculated to provide quantifiable risk increase with DDH, positive predictive value was used as a measure of predictive efficacy. The cost-effectiveness of using these risk factors to predict DDH was evaluated using NHS tariffs (January 2021). Results. The prevalence of DDH that required treatment within our population was 5/1,000 live births. The rate of missed presentation of DDH was 0.43/1000 live births. Breech position, family history, oligohydramnios, and foot deformities demonstrated significant association with DDH (p < 0.0001). The presence of breech presentation increased the risk of DDH by 1.69% (95% confidence interval (CI) 0.93% to 2.45%), family history by 3.57% (95% CI 2.06% to 5.09%), foot deformities by 8.95% (95% CI 4.81% to 13.1%), and oligohydramnios nby 11.6% (95 % CI 3.0% to 19.0%). Primary risk factors family history and breech presentation demonstrated an estimated cost-per-case detection of £6,276 and £11,409, respectively. Oligohydramnios and foot deformities demonstrated a cost-per-case detected less than the cost of primary risk factors of £2,260 and £2,670, respectively. Conclusion. The inclusion of secondary risk factors within a national screening programme was clinically successful as they were more cost and resource-efficient predictors of DDH than primary risk factors, suggesting they should be considered in the national guidance. Cite this article: Bone Jt Open 2023;4(4):234–240


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 5 - 5
3 Mar 2023
Poacher A Ramage G Froud J Carpenter C
Full Access

Introduction. There is little evidence surrounding the clinical implications of a diagnosis of IIa hip dysplasia with no consensus as to its efficacy as a predictor pathological dysplasia or treatment. Therefore, we evaluated the importance of categorising 2a hip dysplasia in to 2a- and 2a+ to better understand the clinical outcomes of each. Methods. A 9-year retrospective cohort study of patients with a diagnosis of type IIa hip dysplasia between 2011 – 2020 (n=341) in our centre. Ultrasound scans were graded using Graf's classification, assessment of management and DDH progression was completed through prospective data collection by the authors. Results. The prevalence of IIa hip dysplasia within our population was 6.7/1000 live births. There was significantly higher incidence of treatment in the IIa- (31.4%, n=17/54) group when compared to the 2a+ group (10%, n=28/287), (p<0.01). In those that had an abnormality (torticollis and/or foot abnormality) treatment rates (24% n=7/29) were significantly (p<0.05) higher than those without anatomical abnormality (15%, n=48/312). Conclusion. This study has demonstrated the significant clinical impact of a IIa- diagnosis on progression to pathological dysplasia and therefore higher rates of treatment in IIa- hips. Furthermore, we have demonstrated the importance of detection of IIa hips through a national screening program, to allow for timely intervention to prevent missing the acetabular maturation window. Therefore, it is our recommendation that all patients with additional anatomical abnormalities and those with a diagnosis of type IIa- hip dysplasia be considered for immediate treatment or urgent follow up following their diagnosis to prevent late conservative intervention


Bone & Joint Open
Vol. 2, Issue 8 | Pages 594 - 598
3 Aug 2021
Arneill M Cosgrove A Robinson E

Aims

To determine the likelihood of achieving a successful closed reduction (CR) of a dislocated hip in developmental dysplasia of the hip (DDH) after failed Pavlik harness treatment We report the rate of avascular necrosis (AVN) and the need for further surgical procedures.

Methods

Data was obtained from the Northern Ireland DDH database. All children who underwent an attempted closed reduction between 2011 and 2016 were identified. Children with a dislocated hip that failed Pavlik harness treatment were included in the study. Successful closed reduction was defined as a hip that reduced in theatre and remained reduced. Most recent imaging was assessed for the presence of AVN using the Kalamchi and MacEwen classification.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 991 - 998
1 May 2021
Lyu X Chen T Yang Z Fu G Feng C Zhang T Lu M

Aims. The objective of this study was to evaluate the clinical and radiological outcomes of patients younger than six months of age with developmental dysplasia of the hip (DDH) managed by either a Pavlik harness or Tübingen hip flexion splint. Methods. Records of 251 consecutive infants with a mean age of 89 days (SD 47), diagnosed with DDH between January 2015 and December 2018, were retrospectively reviewed. Inclusion criteria for patients with DDH were: younger than 180 days at the time of diagnosis; ultrasound Graf classification of IIc or greater; treatment by Pavlik harness or Tübingen splint; and no prior treatment history. All patients underwent hip ultrasound every seven days during the first three weeks of treatment and subsequently every three to four weeks until completion of treatment. If no signs of improvement were found after three weeks, the Pavlik harness or Tübingen splint was discontinued. Statistical analysis was performed. Results. The study included 251 patients with Graf grades IIc to IV in 18 males and 233 females with DDH. Mean follow-up time was 22 months (SD 10). A total of 116 hips were graded as Graf IIc (39.1%), nine as grade D (3.0%), 100 as grade III (33.7%), and 72 as grade IV (24.2%). There were 109 patients (128 hips) in the Pavlik group and 142 patients (169 hips) in the Tübingen group (p = 0.227). The Tübingen group showed a 69.8% success rate in Graf III and Graf IV hips while the success rate was significantly lower in the Pavlik group, 53.9% (p = 0.033). For infants older than three months of age, the Tübingen group showed a 71.4% success rate, and the Pavlik group a 54.4% success rate (p = 0.047). Conclusion. The Tübingen splint should be the preferred treatment option for children older than three months, and for those with severe forms of DDH such as Graf grade III and IV, who are younger than six months at time of diagnosis. The Tübingen hip flexion splint is a valid alternative to the Pavlik harness for older infants and those with more severe DDH. Cite this article: Bone Joint J 2021;103-B(5):991–998


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1533 - 1536
1 Nov 2017
Nie K Rymaruk S Paton RW

Aims. A clicky hip is a common referral for clinical and sonographic screening for developmental dysplasia of the hip (DDH). There is controversy regarding whether it represents a true risk factor for pathological DDH. Therefore a 20-year prospective, longitudinal, observational study was undertaken to assess the relationship between the presence of a neonatal clicky hip and pathological DDH. Patients and Methods. A total of 362 infants from 1997 to 2016 were referred with clicky hips to our ‘one-stop’ paediatric hip screening clinic. Hips were assessed clinically for instability and by ultrasound imaging using a simplified Graf/Harcke classification. Dislocated or dislocatable hips were classified as Graf Type IV hips. Results. The mean age at presentation was 13.8 weeks (12.8 to 14.7). In all 351 out of 362 children (97.0%) had Graf Type I hips (normal) that required no treatment. Nine children (2.5%) had Graf Type II hips but all resolved to Graf Type I hips on follow-up scans. One child (0.3%) had Graf Type III hip dysplasia and one child (0.3%) had an irreducible hip dislocation. The two pathological hips were associated with unilateral limited hip abduction. Mean referrals increased from 12.9 to 23.3 each year (p = 0.002) from the first decade of the study to the second, driven by increasing primary care referrals (5.5 versus 16.7 per year, p < 0.001). Conclusion. Most clicky hips required no treatment other than reassurance to parents. Clicky hips with a normal hip examination should be considered a variant of normal childhood and not a risk factor for DDH. However, an abnormal hip examination including unilateral limited hip abduction should prompt urgent further investigations. Cite this article: Bone Joint J 2017;99-B:1533–6


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_11 | Pages 5 - 5
1 Jun 2017
Nie K Rymaruk S Paton R
Full Access

Purpose. This 20-year prospective longitudinal observational study aims to determine the incidence of pathological developmental dysplasia of the hip (DDH) in children referred with clicky hips and define the risk posed to inform neonatal hip screening programmes including the role of ultrasound. Method. 355 children from 1997 to 2016 were referred with clicky hips to our “one stop” paediatric hip clinic under the local neonatal hip screening programme. Hips were assessed clinically for instability and by ultrasound using a simplified Graf classification. Dislocated or dislocatable hips were classed as Graf type IV. Results. The mean age at presentation was 13.9 (1–56) weeks. 343 out of 355 (96.6%) were Graf type I which required no treatment. 9 (2.5%) were Graf type II but all converted to Graf type I on follow up scans. 2 (0.6%) had Graf type III dysplasia and 1 (0.3%) had irreducible dislocation but all three were associated with limited hip abduction or other hip pathology. Referrals increased from 12.9 to 22.6 per year (p=0.002) from first decade of the study to the second, driven by rising primary care referrals (5.5 vs. 16.5 per year p=0.00002). Conclusion. The study provided robust evidence that overwhelming majority of clicky hips required no treatment other than reassurance to parents. Clicky hips with normal hip examination should be considered a variant of normal childhood and not a risk factor for DDH. However clicky hips with limited hip abduction may represent a separate clinical entity at risk of hip pathology and therefore warrant further investigations


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 42 - 42
1 Dec 2016
Schaeffer E Quader N Mulpuri K Cooper A Hodgson A Abugharbieh R
Full Access

Ultrasound (US) is the standard imaging modality used to screen for developmental dysplasia of the hip in infants. Currently, radiologists or orthopaedic surgeons review scan images and judge them to be adequate or inadequate for interpretation. If considered adequate, diagnostic dysplasia metrics are determined; however, there is no standardised method for this process. There is significant inter-observer variability in this manual process which can affect misdiagnosis rates. To eliminate this subjectivity, we developed an automatic method to identify adequate US images and extract dysplasia metrics. The purpose of this study was to validate the efficacy of this automatic method by comparing results with observer-determined dysplasia metrics on a set of US images. A total of 693 US images from scans of 35 infants were analysed. Trained clinicians at a single institution labeled each image as adequate or inadequate, and subsequently measured alpha and beta angles on adequate images to diagnose dysplasia. We trained our image classifier on random sets of 415 images and used it to assess the remaining 278 images. Alpha and beta angles were automatically estimated on all adequate images. We compared the manual and automatic methods for discrepancies in adequacy determination, metric variability and incidences of missed early diagnosis or over-treatment. There was excellent agreement between the automatic and manual methods in image adequacy classification (Kappa coefficient = 0.912). On each adequate US image, alpha and beta angle measurements were compared, producing mixed levels of agreement between methods. Mean discrepancies of 1.78°±4.72° and 8.91°±6.437° were seen for alpha and beta angles, respectively. Standard deviations of the angle measures across multiple images from a single patient scan were significantly reduced by the automatic method for both alpha (p<0.05) and beta (p<0.01) angles. Additionally, the automatic method classified three hips (two patients) as Graf type II and two hips (two patients) as type III, while the manual method classified them as type I and II, respectively. Both cases flagged as type III patients by the automatic system subsequently failed Pavlik harness treatment and were booked for surgery. The automatic method produced excellent agreement with radiologists in scan adequacy classification and significantly reduced measurement variability. Good agreement between methods was found in Graf classification. In instances of disagreement, subsequent clinical findings seemed to support the classification of the automatic method. This proposed method presents an alternative automatic, near-real-time analysis for US images that may potentially significantly improve dysplasia metric reliability and reduce missed early diagnoses without increasing over-treatment


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 265 - 269
1 Feb 2015
Mace J Paton RW

Over a 15-year prospective period, 201 infants with a clinically unstable hip at neonatal screening were subsequently reviewed in a ‘one stop’ clinic where they were assessed clinically and sonographically. Their mean age was 1.62 weeks (95% confidence interval (CI) 1.35 to 1.89). Clinical neonatal hip screening revealed a sensitivity of 62% (mean, 62.6 95%CI 50.9 to 74.3), specificity of 99.8% (mean, 99.8, 95% CI 99.7 to 99.8) and positive predictive value (PPV) of 24% (mean, 26.2, 95% CI 19.3 to 33.0). Static and dynamic sonography for Graf type IV dysplastic hips had a 15-year sensitivity of 77% (mean, 75.8 95% CI 66.9 to 84.6), specificity of 99.8% (mean, 99.8, 95% CI 99.8 to 99.8) and a PPV of 49% (mean, 55.1, 95% CI 41.6 to 68.5). There were 36 infants with an irreducible dislocation of the hip (0.57 per 1000 live births), including six that failed to resolve with neonatal splintage.

Most clinically unstable hips referred to a specialist clinic are female and stabilise spontaneously. Most irreducible dislocations are not identified from this neonatal instability group. There may be a small subgroup of females with instability of the hip which may be at risk of progression to irreducibility despite early treatment in a Pavlik harness.

A controlled study is required to assess the value of neonatal clinical screening programmes.

Cite this article: Bone Joint J 2015;97-B:265-9.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1553 - 1555
1 Nov 2014
Paton RW Choudry QA Jugdey R Hughes S

There is controversy whether congenital foot abnormalities are true risk factors for pathological dysplasia of the hip. Previous United Kingdom screening guidelines considered congenital talipes equinovarus (CTEV) to be a risk factor for hip dysplasia, but present guidelines do not. We assessed the potential relationship between pathological dysplasia of the hip and fixed idiopathic CTEV.

We present a single-centre 21-year prospective longitudinal observational study. All fixed idiopathic CTEV cases were classified (Harrold and Walker Types 1 to 3) and the hips clinically and sonographically assessed. Sonographic Graf Type III, IV and radiological irreducible hip dislocation were considered to be pathological hip dysplasia.

Over 21 years there were 139 children with 199 cases of fixed idiopathic CTEV feet. Sonographically, there were 259 normal hips, 18 Graf Type II hips, 1 Graf Type III hip and 0 Graf Type IV hip. There were no cases of radiological or sonographic irreducible hip dislocation.

Fixed idiopathic CTEV should not be considered as a significant risk factor for pathological hip dysplasia. This conclusion is in keeping with the current newborn and infant physical examination guidelines in which the only risk factors routinely screened are family history and breech presentation. Our findings suggest CTEV should not be considered a significant risk factor in pathological dysplasia of the hip.

Cite this article: Bone Joint J 2014;96-B:1553–5.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 266 - 270
1 Feb 2013
Uludag S Seyahi A Orak MM Bilgili MG Colakoglu B Demirhan M

Several authors have suggested that the final five weeks of gestation are a critical period for the development of the hip. In order to test the hypothesis that gestational age at birth may influence the development of the hip joint, we analysed the sonographic findings in 1992 hips (in 996 term newborns) with no risk factor for developmental dysplasia of the hip. The 996 infants were born at a mean gestational age of 39 weeks (37 to 41).

The mean bony roof angle (α), cartilage roof angle (β) and the distribution of the type of hip were compared between the 37th, 38th, 39th, 40th and 41st birth week groups. There was a significant difference in the distribution of type of hip between the different birth week groups (p < 0.001), but no significant difference between the α angles of all groups (p = 0.32). There was no correlation between birth week and roof angle (p = 0.407 and p = 0.291, respectively) and no significant correlation between birth weight and roof angle (p = 0.735 and p = 0.132, respectively).

The maturity of the infant hip, as assessed sonographically, does not appear to be affected by gestational age, and the fetal development of the acetabular roof appears to plateau from 37 weeks.

Cite this article: Bone Joint J 2013;95-B:266–70.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 132 - 134
1 Jan 2013
Barr LV Rehm A

Twins are often considered to be at an increased risk of developmental dysplasia of the hip (DDH); we therefore investigated whether multiple births have a higher incidence of DDH, and if selective ultrasound scanning should be considered for these infants.

We reviewed our records of all live births between 1 January 2004 and 31 December 2008 and included 25 246 single and 990 multiple births.

Multiple births did not have a significantly higher incidence of DDH compared with single births (0.0030 vs 0.0023, p = 0.8939). Of the 990 multiple births, 267 had neonatal ultrasound scans and one case of DDH was diagnosed and treated successfully with a Pavlik harness. There were two late-presenting cases at eight and 14 months of age, neither of whom had risk factors for DDH and consequently had not had a neonatal scan. Whereas selective ultrasound scanning of multiple births would have led to earlier detection and treatment of the late-presenting cases, they did not have a significantly higher incidence of DDH compared with single births.

We conclude that being a twin or triplet in itself is not a risk factor for DDH and that selective ultrasound scanning is not indicated for this population.

Cite this article: Bone Joint J 2013;95-B:132–4.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 146 - 146
1 Sep 2012
Naqvi G Malik S Adamec O
Full Access

Aim. The aim of this study is to assess the effectiveness of clinic based ultrasound screening by Orthopaedic surgeon for early diagnosis and treatment of developmental dysplasia of hip (DDH) in one stop clinic. Methods. This prospective study included 395 infants (185 male and 210 female) (5.2% of study population) who were referred for screening on the basis of abnormal findings or the presence of risk factors for DDH. Average age was 12.5 weeks (1 day to 15 months). All infants were assessed for risk factors of DDH. Clinical examinations were performed by the senior author followed by ultrasonography of both of the infant's hips, using the Graf's technique. Alpha and beta angles were calculated and hips were classified according to Graf's classification system. Results. Out of 790 hips examined 670 (84.8%) were labelled as normal. 120 (15.1%) hips in 84 patients were diagnosed as dysplastic or dislocated. Clinical examination only detected 39 patients out of 84, sensitivity of 46%. Average age of diagnosis was 12 weeks (3days-11 months). 79 patients were successfully treated with pavlic harness, 2 required traction and 3 were referred for surgical treatment. There were 14 cases of late diagnosis during one year period (> 4 months of age) (1.8/1000). Conclusion. Selective ultrasound screening is effective in early diagnosis of DDH and significantly reduces the duration of non operative treatment as well as the need for surgical intervention but does not completely eliminate late diagnosis of DDH. We find the concept of one stop DDH clinic highly effective and recommend that ultrasound training should be a part of orthopaedic curriculum


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 842 - 847
1 Jun 2012
Eberhardt O Fernandez FF Wirth T

We present our early experience of arthroscopic reduction of the dislocated hip in very young infants with developmental dysplasia of the hip (DDH).

Eight dislocated hips, which had failed attempts at closed reduction, were treated by arthroscopy of the hip in five children with a mean age of 5.8 months (4 to 7). A two-portal technique was used, with a medial sub-adductor portal for a 2.7 mm cannulated system with a 70° arthroscope and an anterolateral portal for the instruments. Following evaluation of the key intra-articular structures, the hypertrophic ligamentum teres and acetabular pulvinar were resected, and a limited release of the capsule was performed prior to reduction of the hip. All hips were reduced by a single arthroscopic procedure, the reduction being confirmed on MRI scan. None of the hips had an inverted labrum. The greatest obstacle to reduction was a constriction of the capsule. At a mean follow-up of 13.2 months (9 to 24), all eight hips remained stable. Three developed avascular necrosis. The mean acetabular index decreased from 35.5° (30° to 40°) pre-operatively to 23.3° (17° to 28°).

This study demonstrates that arthroscopic reduction is feasible using two standardised portals. Longer follow-up studies are necessary to evaluate the functional results.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1695 - 1699
1 Dec 2010
Fox AE Paton RW

This prospective cohort study aimed to investigate the relationship between developmental dysplasia of the hip and mode of delivery in 571 consecutive breech infants using a modified Graf’s static morphological method to grade the severity of dysplasia.

In this group, 262 infants were born by planned Caesarian section, 223 by emergency section and 86 vaginally. Taking all grades of hip dysplasia into account (Graf types II, III and IV), there was no statistical difference in the incidence of dysplasia between the groups (elective section 8.4%, emergency section 8.1% and vaginal delivery 7.0%). However, when cases with Graf type II dysplasia, which may represent physiological immaturity, were excluded, the rate of type III and IV hips, which we consider to be clinically relevant, increased in the vaginally delivered group (4.7%) compared with the elective section group (1.1%), with a relative risk of approximately 1:4 (95% confidence interval 1.03 to 15.91). No difference was observed between the emergency and elective section groups, or between the emergency section and vaginally delivered groups.

This study supports previous published work, with the added value that the diagnoses were all confirmed by ultrasound.