The aim of this study was to determine both the incidence of, and the reoperation rate for, postoperative periprosthetic femoral fracture (POPFF) after total hip arthroplasty (THA) with either a collared cementless (CC) femoral component or a cemented polished taper-slip (PTS) femoral component. We performed a retrospective review of a consecutive series of 11,018 THAs over a ten-year period. All POPFFs were identified using regional radiograph archiving and electronic care systems.Aims
Methods
Abstract. Introduction. In cementless UKR, primary fixation of the tibial component is achieved by press-fitting a keel (i.e. with interference) into a vertical slot cut into the proximal tibia. This may adversely affect the structural integrity of surrounding bone. Early post-operative peri-prosthetic tibial fractures are 7x more common in very small knees, but the aetiology of these fractures is unknown - such sizes are rarely used in the UK but more common in Asian populations. This study explores the effect of keel-related features in fracture risk of these very small tibias. Method. This in vitro study compares the effect of keel and slot depth (standard vs 33% shallower vs nil) and loading position (anterior/posterior gait range limits: mid-tibia vs 8mm posterior) on
Periprosthetic hip fractures (PPFs) after total hip arthroplasty are difficult to treat. Therefore, it is important to identify modifiable risk factors such as stem selection to reduce the occurrence of PPFs. This study aimed to clarify differences in fracture torque, surface strain, and fracture type analysis between three different types of cemented stems. We conducted biomechanical testing of bone analogues using six cemented stems of three different types: collarless polished tapered (CPT) stem, Versys Advocate (Versys) stem, and Charnley-Marcel-Kerboull (CMK) stem. Experienced surgeons implanted each of these types of stems into six bone analogues, and the analogues were compressed and internally rotated until failure. Torque to fracture and fracture type were recorded. We also measured surface strain distribution using triaxial rosettes.Aims
Methods
The distal radius is a major site of osteoporotic bone loss resulting in a high risk of fragility fracture. This study evaluated the capability of a cortical index (CI) at the distal radius to predict the local bone mineral density (BMD). A total of 54 human cadaver forearms (ten singles, 22 pairs) (19 to 90 years) were systematically assessed by clinical radiograph (XR), dual-energy X-ray absorptiometry (DXA), CT, as well as high-resolution peripheral quantitative CT (HR-pQCT). Cortical bone thickness (CBT) of the distal radius was measured on XR and CT scans, and two cortical indices mean average (CBTavg) and gauge (CBTg) were determined. These cortical indices were compared to the BMD of the distal radius determined by DXA (areal BMD (aBMD)) and HR-pQCT (volumetric BMD (vBMD)). Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC) were used to compare the results and degree of reliability.Aims
Methods
Type 2 diabetes mellitus (T2DM) impairs bone strength and is a significant risk factor for hip fracture, yet currently there is no reliable tool to assess this risk. Most risk stratification methods rely on bone mineral density, which is not impaired by diabetes, rendering current tests ineffective. CT-based finite element analysis (CTFEA) calculates the mechanical response of bone to load and uses the yield strain, which is reduced in T2DM patients, to measure bone strength. The purpose of this feasibility study was to examine whether CTFEA could be used to assess the hip fracture risk for T2DM patients. A retrospective cohort study was undertaken using autonomous CTFEA performed on existing abdominal or pelvic CT data comparing two groups of T2DM patients: a study group of 27 patients who had sustained a hip fracture within the year following the CT scan and a control group of 24 patients who did not have a hip fracture within one year. The main outcome of the CTFEA is a novel measure of hip bone strength termed the Hip Strength Score (HSS).Aims
Methods
A balanced inflammatory response is important for successful fracture healing. The response of osteoporotic fracture healing is deranged and an altered inflammatory response can be one underlying cause. The objectives of this review were to compare the inflammatory responses between normal and osteoporotic fractures and to examine the potential effects on different healing outcomes. A systematic literature search was conducted with relevant keywords in PubMed, Embase, and Web of Science independently. Original preclinical studies and clinical studies involving the investigation of inflammatory response in fracture healing in ovariectomized (OVX) animals or osteoporotic/elderly patients with available full text and written in English were included. In total, 14 articles were selected. Various inflammatory factors were reported; of those tumour necrosis factor-α (TNF-α) and interleukin (IL)-6 are two commonly studied markers. Preclinical studies showed that OVX animals generally demonstrated higher systemic inflammatory response and poorer healing outcomes compared to normal controls (SHAM). However, it is inconclusive if the local inflammatory response is higher or lower in OVX animals. As for clinical studies, they mainly examine the temporal changes of the inflammatory stage or perform comparison between osteoporotic/fragility fracture patients and normal subjects without fracture. Our review of these studies emphasizes the lack of understanding that inflammation plays in the altered fracture healing response of osteoporotic/elderly patients. Taken together, it is clear that additional studies, preclinical and clinical, are required to dissect the regulatory role of inflammatory response in osteoporotic fracture healing. Cite this article:
The disadvantage of removing a well-fixed femoral stem are multiple (operating time, risk of fracture, bone and blood loss, recovery time and post-op complications. Ceramic heads with titanium adapter sleeves (e.g. BIOLOX®OPTION, Ceramtec) are a possibility for putting a new ceramic head on slightly damaged used tapers. ‘Intolerable’ taper damages even for this solution are qualitatively specified by the manufacturers. The aim of this study was to determine the fracture strength of ceramic heads with adapter sleeves on stem tapers with such defined damage patterns. Pristine stem tapers (Ti-6Al-4V, 12/14) were damaged to represent the four major stem taper damage patterns specified by the manufacturers:
. -. ‘Truncated’: Removal of 12.5% of the circumference along the entire length of the stem taper at a uniform depth of 0.5mm parallel to the taper slope. -. ‘Slanted’: Removal of 33.3% of the proximal diameter perimeter with decreasing damage down to 3.7mm from the proximal taper end. -. ‘Cut’: Removal of the proximal 25% (4mm) of the stem taper. -. ‘Scratched’: Stem tapers from a previous ceramic fracture test study with a variety of scratches and crushing around the upper taper edge from multiple ceramic head fractures. -. The ‘Control’ group consisted of three pristine tapers left undamaged. BIOLOX®OPTION heads (Ø 32mm, length M) with Ti adapter sleeves were assembled to the damaged stem tapers and subjected to ISO7206-10 ultimate compression strength testing. The forces required to fracture the head were high and caused complete destruction of the ceramic heads in all cases. The ‘Truncated’ group showed the lowest values (136kN ± 4.37kN; Fig. 3). Forces were higher and similar for the ‘Cut’ (170kN ± 8.89kN), ‘Control’ (171.8 ± 16.5kN) and ‘Slanted’ (173kN ± 21.9kN) groups, the ‘Scratched’ group showed slightly higher values (193kN ± 11.9kN). The Ti adapter sleeves were plastically deformed but did not fail catastrophically. The present study suggests that manufacturer's recommendations for removal of a well fixed femoral stem could be narrowed down to the ‘Truncated’ condition. Even this might not be necessary since the
Introduction. Up to 60% of total hip arthroplasties (THA) in Asian populations arise from avascular necrosis (AVN), a bone disease that can lead to femoral head collapse. Current diagnostic methods to classify AVN have poor reproducibility and are not reliable in assessing the fracture risk. Femoral heads with an immediate fracture risk should be treated with a THA, conservative treatments are only successful in some cases and cause unnecessary patient suffering if used inappropriately. There is potential to improve the assessment of the fracture risk by using a combination of density-calibrated computed tomographic (QCT) imaging and engineering beam theory. The aim of this study was to validate the novel fracture prediction method against in-vitro compression tests on a series of six human femur specimens. Methods. Six femoral heads from six subjects were tested, a subset (n=3) included a hole drilled into the subchondral area of the femoral head via the femoral neck (University of Leeds, ethical approval MEEC13-002). The simulated lesions provided a method to validate the fracture prediction model with respect of AVN. The femoral heads were then modelled by a beam loaded with a single joint contact load. Material properties were assigned to the beam model from QCT-scans by using a density-modulus relationship. The maximum joint loading at which each bone cross-section was likely to fracture was calculated using a strain based failure criterion. Based on the predicted
Multiple myeloma (MM) is a chronic, malignant B-cell disorder, with a less than 50% 5-year survival rate [1]. This disease is responsible for vertebral compression fractures (VCFs) in 34 to 64% of diagnosed patients [1], and at least 80% of MM patients experience pathological fractures [3]. Even though reduced DXA-derived bone mineral density (BMD) has been observed in MM patients with vertebral fractures [4], the current quantitative standard method is insufficient in MM due to the osteo-destructive bone changes. Finite-element (FE) analysis is a computational and non-destructive modeling and testing approach to determine bone strength using 3D bone models from CT images. Thus, this study aimed to assess the differences in FE-predicted critical
The high risk and the associated high mortality of secondary, contralateral hip fractures [1,2] could justify internal, invasive prophylactic reinforcement of the osteoporotic proximal femur to avoid these injuries in case of a low energy fall. Previous studies have demonstrated high potential of augmentation approaches [3,4,5], but to date there has no ideal solution been found. The development of optimized reinforcement strategies can be aided with validated computer simulation tools that can be used to evaluate new ideas. A validated non-linear finite element (FE) simulation tool was used here to predict the yield and
Objectives. This investigation sought to advance the work published in our prior biomechanical study (Journal of Orthopaedic Research, 2016). We specifically sought to determine whether there are additional easy-to-measure parameters on plain radiographs of the proximal humerus that correlate more strongly with ultimate
Most of researches related to osteoporosis emphasized on trabecular bone loss. However, cortical bone has a prominent role on bone strength determined by bone quality, such as 2D or 3D geometry and microstructure of bone, not only density.[1] The focal thinning of cortical bone associated with aging in post-menopausal osteoporotic bone in the proximal femur may predispose a hip to fracture.[2, 3] As the trabecular bone is lost with progression of osteoporosis, the remaining cortical bone take more predominant role on bone strength.[4] To date, no effective osteoporotic agent was demonstrated to enhance both cortical geometric change and bone strength. Herein, we investigate the effect of Teriparatide (rhPTH(1–34)) on cortical bone at femoral diaphysis in OVX rat model. Twenty 12-week-old, female Sprague Dawley rats were used in this study. Bilateral ovariectomies were performed in 16 animals and randomly divided to three groups as control (N=6), OVX (N=6) and treatment group after OVX (OVX+F) by teriparatide (N=8). After twelve weeks of intervention, all rats were euthanized and right femurs and L5 vertebrae were extracted for further tests. All bone specimens were subjected to dual-energy X-ray absorptiometer (DXA) to evaluate areal bone mineral density (aBMD) of L5 vertebrae and femurs, micro-computed tomography (micro-CT) to analyze cortical bone parameters of femoral diaphysis, including cortical cross section area (CSA), cortical thickness and cross-sectional moment of inertia (CSMI). A three-point bending test was applied to determine
INTRODUCTION. Ceramic hip components are known for their superior material properties and longevity. In comparison to other materials commonly used, ceramics have a very low friction coefficient and a high
Since artificial joints are expected to operate for more than decades in human body, animal and clinical studies are not suitable for evaluation of their durability. Instead, in-vitro mechanical tests have been employed, but they cannot fully reproduce complex in-vivo mechanical and biochemical environment. For instance, lipids in synovial fluid have been known to be absorbed in ultra-high molecular weight polyethylene (UHMWPE) components of artificial joints in vivo, and recently it was found that absorbed lipids have potential to degrade UHMWPE. In order to assure clinical relevance of the in-vitro mechanical tests, understanding of the effect of the in-vivo environment on mechanical properties is indispensable. However, well-developed mechanical tests cannot be applied to retrieved components, because they require large specimens. In this study, we attempted to develop methods to evaluate mechanical properties of retrieved UHMWPE components. We prepared five kinds of UHMWPE. Those are molded UHMWPE made from GUR 1020 resin without any further treatment, remelted highly crosslinked UHMWPE, annealed highly crosslinked UHMWPE, squalene absorbed UHMWPE which was prepared by immersing in squalene at 80°C for 7 days (SQ) and squalene absorbed and artificially aged UHMWPE which was prepared by artificially aging SQ at 80°C for 21 days in air (SQA). SQ and SQA were employed in this study to mimic lipid absorption and lipid induced degradation. These materials were tested by two well-established mechanical tests, namely, tensile tests and compression tests, and two proposed mechanical tests that can be applied to retrieved components, namely, tensile punch tests and micro indentation tests. It was possible to clearly identify the difference between materials by any of test methods used in this study. Stiffness obtained from tensile punch tests and elastic modulus obtained from micro indentation tests were shown to be highly correlated with elastic modulus obtained from compression tests except for SQA, which was inhomogeneous due to degradation at the surfaces. The results showed that the elastic modulus of the local surface could be evaluated by micro indentation tests, while the average of that of the entire specimen could be evaluated by compression tests. ield
This animal study compares different methods
of performing an osteotomy, including using an Erbium-doped Yttrium
Aluminum Garnet laser, histologically, radiologically and biomechanically.
A total of 24 New Zealand rabbits were divided into four groups
(Group I: multihole-drilling; Group II: Gigli saw; Group III: electrical
saw blade and Group IV: laser). A proximal transverse diaphyseal
osteotomy was performed on the right tibias of the rabbits after the
application of a circular external fixator. The rabbits were killed
six weeks after the procedure, the operated tibias were resected
and radiographs taken. The specimens were tested biomechanically using three-point bending
forces, and four tibias from each group were examined histologically.
Outcome parameters were the biomechanical stability of the tibias
as assessed by the failure to load and radiographic and histological
examination of the osteotomy site. The osteotomies healed in all specimens both radiographically
and histologically. The differences in the mean radiographic (p
= 0.568) and histological (p = 0.71) scores, and in the mean failure
loads (p = 0.180) were not statistically significant between the
groups. Different methods of performing an osteotomy give similar quality
of union. The laser osteotomy, which is not widely used in orthopaedics
is an alternative to the current methods. Cite this article:
Introduction:. In an attempt to reduce stress shielding in the proximal femur multiple new shorter stem design have become available. We investigated the
Introduction. Periprosthetic medial tibial plateau fractures (TPF) are rare but represent a serious complication in unicompartmental knee arthroplasty (UKA). Most common treatment of these fractures is osteosynthesis with canulated screws or plates. Aim. The aim of this study was to evaluate these two different treatment options of periprosthetic fractures. The hypothesis was that osteosynthetic treatment with plates show significantly higher maximum
Purpose. Twelve case reports of distal femur fractures as post-operative complications after anterior cruciate ligament (ACL) reconstruction have been described in the literature. The femoral tunnel has been suggested as a potential stress riser for fracture formation. The recent increase in double bundle ACL reconstructions may compound this risk. This is the first biomechanical study to examine the stress riser effect of the femoral tunnel(s) after ACL reconstruction. The hypotheses tested in this study are that the femoral tunnel acts as a stress riser to fracture and that this effect increases with the size of the tunnel (8mm versus 10mm) and with the number of tunnels (one versus two). Method. Femoral tunnels simulating single bundle (SB) hamstring graft (8 mm), bone-patellar tendon-bone graft (10 mm), and double bundle (DB) ACL reconstruction (7mm, 6 mm) were drilled in fourth generation saw bones. These three experimental groups and a control group consisting of native saw bones without tunnels, were loaded to failure. Result. All fractures occurred through the tunnels in the double tunnel group whereas fractures did not consistently occur through the tunnels in the single tunnel groups. The mean
The June 2012 Trauma Roundup360 looks at: nerve injuries of warfare; the medical complications of earthquakes; the measuring of tissue pressures in compartment syndrome; the risk of plunging through the bone when drilling; bony nonunion and negative pressure therapy; surgery for the posteriorly dislocated hip; whether to use the sliding screw or intramedullary nail for the trochanteric fracture; antegrade interlocking nailing for the distal femoral fracture; and gunshot wounds to the pancreas.
Ceramic hip components are known for their superior material properties concerning the invivo loading situation. In comparison to other commonly used materials, ceramics have a very low friction coefficient and a high