The aims of this study were: 1) to describe extended restricted kinematic alignment (E-rKA), a novel alignment strategy during robotic-assisted total knee arthroplasty (RA-TKA); 2) to compare residual medial compartment tightness following virtual surgical planning during RA-TKA using mechanical alignment (MA) and E-rKA, in the same set of osteoarthritic varus knees; 3) to assess the requirement of soft-tissue releases during RA-TKA using E-rKA; and 4) to compare the accuracy of surgical plan execution between knees managed with adjustments in component positioning alone, and those which require additional soft-tissue releases. Patients who underwent RA-TKA between January and December 2022 for primary varus osteoarthritis were included. Safe boundaries for E-rKA were defined. Residual medial compartment tightness was compared following virtual surgical planning using E-rKA and MA, in the same set of knees. Soft-tissue releases were documented. Errors in postoperative alignment in relation to planned alignment were compared between patients who did (group A) and did not (group B) require soft-tissue releases.Aims
Methods
Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems. In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years.Aims
Methods
Orthopaedic surgeons are currently faced with an overwhelming number of choices surrounding total knee arthroplasty (TKA), not only with the latest technologies and prostheses, but also fundamental decisions on alignment philosophies. From ‘mechanical’ to ‘adjusted mechanical’ to ‘restricted kinematic’ to ‘unrestricted kinematic’ — and how constitutional alignment relates to these — there is potential for ambiguity when thinking about and discussing such concepts. This annotation summarizes the various alignment strategies currently employed in TKA. It provides a clear framework and consistent language that will assist surgeons to compare confidently and contrast the concepts, while also discussing the latest opinions about alignment in TKA. Finally, it provides suggestions for applying consistent nomenclature to future research, especially as we explore the implications of 3D alignment patterns on patient outcomes. Cite this article:
The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years.Aims
Methods
It is unknown whether gap laxities measured in robotic arm-assisted total knee arthroplasty (TKA) correlate to load sensor measurements. The aim of this study was to determine whether symmetry of the maximum medial and lateral gaps in extension and flexion was predictive of knee balance in extension and flexion respectively using different maximum thresholds of intercompartmental load difference (ICLD) to define balance. A prospective cohort study of 165 patients undergoing functionally-aligned TKA was performed (176 TKAs). With trial components in situ, medial and lateral extension and flexion gaps were measured using robotic navigation while applying valgus and varus forces. The ICLD between medial and lateral compartments was measured in extension and flexion with the load sensor. The null hypothesis was that stressed gap symmetry would not correlate directly with sensor-defined soft tissue balance.Aims
Methods
Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA. A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed.Aims
Methods
In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up. A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis.Aims
Methods
The COVID-19 pandemic has led to unprecedented times worldwide. From lockdowns to masks now being part of our everyday routine, to the halting of elective surgeries, the virus has touched everyone and every part of our personal and professional lives. Perhaps, now more than ever, our ability to adapt, change and persevere is critical to our survival. This year's closed meeting of The Knee Society demonstrated exactly those characteristics. When it became evident that an in-person meeting would not be feasible, The Knee Society leadership, under the direction of President John Callaghan, MD and Program Chair Craig Della Valle, MD created a unique and engaging meeting held on September 10–12, 2020. Special recognition should be given to Olga Foley and Cynthia Garcia at The Knee Society for their flexibility and creativeness in putting together a world-class flawless virtual program. The Bone & Joint Journal is very pleased to partner with The Knee Society to once again publish the proceedings of the closed meeting of the Knee Society. The Knee Society is a United States based society of highly selected members who have shown leadership in education and research in knee surgery. It invites up to 15% international members; this includes some of the key opinion leaders in knee surgery from outside the USA. Each year, the top research papers from The Knee Society meeting will be published and made available to the wider orthopaedic community in The Bone & Joint Journal. The first such proceedings were published in BJJ in 2019. International dissemination should help to fulfil the mission and vision of the Knee Society of advancing the care of patients with knee disorders through leadership, education and research. The quality of dissemination that The Bone & Joint Journal provides should enhance the profile of this work and allow a larger body of surgeons, associated healthcare professionals and patients to benefit from the expertise of the members of The Knee Society. The meeting is one of the highlights of the annual academic calendar for knee surgeons. With nearly every member in attendance virtually throughout the 3 days, the top research papers from the membership were presented and discussed in a virtual format that allowed for lively interaction and discussion. There are 75 abstracts presented. More selective proceedings with full papers will be available after a robust peer review process in 2021, both online and in The Bone & Joint Journal. The meeting commenced with the first group of scientific papers focused on Periprosthetic Joint Infection. Dr Berry and colleagues from the Mayo Clinic further help to clarify the issue of serology and aspirate results to diagnose TKA PJI in the acute postoperative setting. 177 TKA's had an aspiration within 12 weeks and 22 were proven to have PJI. Their results demonstrated that acute PJI after TKA should be suspected within 6 weeks if CRP is ≥81 mg/L, synovial WBCs are ≥8500 cells/μL, and/or synovial neutrophils≥86%. Between 6– 12 weeks, concerning thresholds include a CRP ≥ 32 mg/L, synovial WBC ≥7450, and synovial neutrophils ≥ 84%. While historically the results of a DAIR procedure for PJI have been variable, Tom Fehring's study showed promise with the local delivery of vancomycin through the Intraosseous route improved early results. New member Simon Young contrasted the efficacy of the DAIR procedure when comparing early infections to late acute hematogenous PJI. DAIR failed in 63% of late hematogenous PJIs (implant age>1 year) compared to 36% of early (<1year) PJIs. Dr Masri demonstrated in a small group of patients that those with well-functioning articulating spacers can retain their spacers for over 12 months with no difference in infection from those that had a formal two stage exchange. The mental toll of PJI was demonstrated in a longitudinal study by Doug Dennis, where patient being treated with 2 stage exchange had 4x higher rates of depression compared to patient undergoing aseptic revision. The second session focused on both postoperative issues with regards to anticoagulation and manipulation. Steven Haas demonstrated high complication rates with utilization of anticoagulation for treatment of postoperative pulmonary embolism with modern therapeutic anticoagulation (warfarin, enoxaparin, Xa inhibitors) with the Xa inhibitors demonstrating lower complication rates. Two papers focused on the topic of manipulation. Mark Pagnano presented data on timing of manipulation under anesthesia up to even past 12 months. While gains were modest, a subset of patients did achieve substantial gains in ROM > 20degrees even after 3 months post op. Dr Westrich's study demonstrated no difference in MUA outcomes with either IV sedation or neuraxial anesthesia although the length of stay was shorter in the IV sedation group. Several studies in Session II focused on kinematics and femoral component position. Dr Li's in vivo kinematic study during weightbearing flexion and gait demonstrated that several knees rotated with a lateral pivot motion and not all knees can be described with a single motion character. Dr Mayman and his group utilized a computational knee model to demonstrate that additional distal femoral resection results in increasing levels of mid -flexion instability and cautioned against the use of additional bony resection as the first line for flexion contractures. Using computer navigation, Dr Huddleston's study nicely outlined the variability in
Introduction. Instability is a common reason for revision after total knee arthroplasty. A balanced flexion gap is likely to enhance stability throughout the arc of motion. This is achieved differently by the gap balancing and measured resection techniques. Given similar clinical results with the two techniques, one would expect similar rotation of the femoral component in the axial plane. We assessed posterior-stabilized
There are comparatively few randomized studies evaluating knee arthroplasty prostheses, and fewer still that report longer-term functional outcomes. The aim of this study was to evaluate mid-term outcomes of an existing implant trial cohort to document changing patient function over time following total knee arthroplasty using longitudinal analytical techniques and to determine whether implant design chosen at time of surgery influenced these outcomes. A mid-term follow-up of the remaining 125 patients from a randomized cohort of total knee arthroplasty patients (initially comprising 212 recruited patients), comparing modern (Triathlon) and traditional (Kinemax) prostheses was undertaken. Functional outcomes were assessed with the Oxford Knee Score (OKS), knee range of movement, pain numerical rating scales, lower limb power output, timed functional assessment battery, and satisfaction survey. Data were linked to earlier assessment timepoints, and analyzed by repeated measures analysis of variance (ANOVA) mixed models, incorporating longitudinal change over all assessment timepoints.Aims
Methods
The primary aim of this study was to describe a baseline comparison of early knee-specific functional outcomes following revision total knee arthroplasty (TKA) using metaphyseal sleeves with a matched cohort of patients undergoing primary TKA. The secondary aim was to compare incidence of complications and length of stay (LOS) between the two groups. Patients undergoing revision TKA for all diagnoses between 2009 and 2016 had patient-reported outcome measures (PROMs) collected prospectively. PROMs consisted of the American Knee Society Score (AKSS) and Short-Form 12 (SF-12). The study cohort was identified retrospectively and demographics were collected. The cohort was matched to a control group of patients undergoing primary TKA.Introduction
Methods
Purpose. The purpose of this study was to elucidate kinematic change according to the implant's specific femoral rotation by using orthosensor (Verasense) implant with three degrees external rotation of femoral rotation rebuilt (Genesis-II) and traditional TKA implant without rebuilt of the femoral rotation (Anthem). Methods. Twenty-eight patients (34 knees) underwent TKA using Anthem (Smith & Nephew, Memphis, TN, USA) and 16 patients (22 knees) underwent TKA using Genesis-II (Smith & Nephew, Memphis, TN, USA). Patients were followed up for at least 1 year. Mean age of patients was 71.1 years (range, 60 to 80 years) at the time of surgery. After implantation of femur and tibial components, we applied Verasense, the orthosensor system, to evaluate femoral rollback of the new artificial joint. Femoral rollback was analyzed using digitized screenshot function of Verasense. Results. Overall femoral tracking proportion regardless of implants was significantly higher on the medial compartment compared to that on the lateral compartment (13.3 ± 8.4% vs. 6.3 ± 5.0%, p < 0.001). Regarding femoral tracking according to each compartment, Genesis-II and Anthem showed 12.1 ± 8.2% and 14.2 ± 8.6% (p = 0.371) on the medial compartment and 8.0 ± 5.8% and 5.2 ± 4.2% (p = 0.059) on the lateral compartment, respectively. Conclusion. Our study showed reverse femoral roll-back movement with higher tracking distance on the lateral compartment during TKA. Genesis-II TKA system with femoral component 3-degree rebuilt showed less roll-back difference between medial and lateral compartments compared to traditional TKA system. Fortunately, both TKA systems had excellent short-term clinical outcomes without having significant difference between the two. With longer follow-up and larger cohort, the advantage and effectiveness of
Introduction. Instability, loosening, and patellofemoral pain belong to the main causes for revision of total knee arthroplasty (TKA). Currently, the diagnostic pathway requires various diagnostic techniques such as x-rays, CT or SPECT-CT to reveal the original cause for the failed knee prosthesis, but increase radiation exposure and fail to show soft-tissue structures around TKA. There is a growing demand for a diagnostic tool that is able to simultaneously visualize soft tissue structures, bone, and TKA without radiation exposure. MRI is capable of visualising all the structures in the knee although it is still disturbed by susceptibility artefacts caused by the metal implant. Low-field MRI (0.25T) results in less metal artefacts and offers the ability to visualize the knee in weight-bearing condition. Therefore, the aim of this study is to investigate the possibilities of low field MRI to image, the patellofemoral joint and the prosthesis to evaluate the knee joint in patients with and without complaints after TKA. Method. Ten patients, eight satisfied and two unsatisfied with their primary TKA, (NexGen posterior stabilized, BiometZimmer) were included. The patients were scanned in sagittal, coronal, and transversal direction on a low field MRI scanner (G-scan Brio, 0.25T, Esaote SpA, Italy) in weight-bearing and non-weight-bearing conditions with T1, T2 and PD-weighted metal artefact reducing sequences (TE/TR 12–72/1160–7060, slice thickness 4.0mm, FOV 260×260×120m. 3. , matrix size 224×216). Scans were analysed by two observers for:. - Patellofemoral joint: Caton-Descamps index and Tibial Tuberosity-Trochlear Groove (TT-TG) distance. - Prosthesis malalignment:
Introduction. Component position and overall limb alignment following total knee arthroplasty (TKA) have been shown to influence prosthetic survivorship and clinical outcomes. Robotic-assisted (RA) total knee arthroplasty has demonstrated improved accuracy to plan in cadaver studies compared to conventionally instrumented (manual) TKA, but less clinical evidence has been reported. The objective of this study was to compare the three-dimensional accuracy to plan of RATKA with manual TKA for overall limb alignment and component position. Methods. A non-randomized, prospective multi-center clinical study was conducted to compare RATKA and manual TKA at 4 U.S. centers between July 2016 and August 2018. Computed tomography (CT) scans obtained approximately 6 weeks post-operatively were analyzed using anatomical landmarks. Absolute deviation from surgical plans were defined as the absolute value of the difference between the CT measurements and surgeons’ operative plan for overall limb, femoral and tibial component mechanical varus/valgus alignment, tibial component posterior slope, and femoral component internal/external rotation. We tested the differences of absolute deviation from plan between manual and RATKA groups using stratified Wilcoxon tests, which controlled for study center and accounted for skewed distributions of the absolute values. Alpha was 0.05 two-sided. At the time of this abstract, data collections were completed for two centers (52 manual and 58 RATKA). Results. Comparing absolute deviation from plan between groups, RATKA demonstrated clear benefits for tibial component alignment (median absolute deviation from plan: 1.5° vs. 0.8°, manual vs RATKA, p<.001), tibial slope (2.7° vs. 1.1°, manual vs RATKA, p<.001), and
It is unknown whether kinematic alignment (KA) objectively improves knee balance in total knee arthroplasty (TKA), despite this being the biomechanical rationale for its use. This study aimed to determine whether restoring the constitutional alignment using a restrictive KA protocol resulted in better quantitative knee balance than mechanical alignment (MA). We conducted a randomized superiority trial comparing patients undergoing TKA assigned to KA within a restrictive safe zone or MA. Optimal knee balance was defined as an intercompartmental pressure difference (ICPD) of 15 psi or less using a pressure sensor. The primary endpoint was the mean intraoperative ICPD at 10° of flexion prior to knee balancing. Secondary outcomes included balance at 45° and 90°, requirements for balancing procedures, and presence of tibiofemoral lift-off.Aims
Methods
Introduction. Component position and overall limb alignment following total knee arthroplasty (TKA) have been shown to influence prosthetic survivorship and clinical outcomes. 1. The objective of this study was to compare the accuracy to plan of three-dimensional modeled (3D) TKA with manual TKA for component alignment and position. Methods. An open-label prospective clinical study was conducted to compare 3D modeling with manual TKA (non-randomized) at 4 U.S. centers between July 2016 and August 2018. Men and women aged > 18 with body mass index < 40kg/m. 2. scheduled for unilateral primary TKA were recruited for the study. 144 3DTKA and 86 manual TKA (230 patients) were included in the analysis of accuracy outcomes. Seven high-volume, arthroplasty fellowship-trained surgeons performed the surgeries. The surgeon targeted a neutral (0°) mechanical axis for all except 9 patients (4%) for whom the target was within 0°±3°. Computed tomography (CT) scans obtained approximately 6 weeks post-operatively were analyzed using anatomical landmarks to determine femoral and tibial component varus/valgus position, femoral component internal/external rotation, and tibial component posterior slope. Absolute deviation from surgical plan was defined as the absolute value of the difference between the CT measurement and the surgeon's operative plan. Smaller absolute deviation from plan indicated greater accuracy. Mean component positions for manual and 3DTKA groups were compared using two-sample t tests for unequal variances. Differences of absolute deviations from plan were compared using stratified Wilcoxon tests, which controlled for study center and accounted for skewed distributions of the absolute values. Alpha was 0.05 two-sided. At the time of this report, CT measurements of
Background. Accurate implant positioning is of supreme importance in total knee replacement (TKR). The rotational profile of the femoral and tibial components can affect outcomes, and the aim is to achieve coronal conformity with parallelism between the medio-lateral axes of the femur and tibia. Aims. The aim of this study is to determine the accuracy of implant rotation in total knee replacement. Methods. Intra-operatively, the trans-epicondylar axis of the femur (TEA) and Whiteside's line were used as the reference points, aiming to externally rotate the femoral component by 1 degree. The medial third of the tibial tuberosity was used as the anatomical reference point, aiming to reproduce the rotation of the native tibia. Pre-and post-operative CT scans were reviewed. The difference in femoral rotation was calculated by determining the femoral posterior condylar axis (PCA) of the native femur pre-operatively and the implant post-operatively. Tibial rotational difference was calculated between the native tibial posterior condylar axis and tibial baseplate. Results. Pre and post-operative CT scans of 41 knees in 31 patients were analysed. All surgeries were carried out by a single surgeon using the same implant. The mean difference in rotation of the femur post-operatively was 1.2 degrees external rotation (ER), range −4.7 to 6.9 degrees ER. 83% of femoral components were within 3 degrees of the target rotation. Mean difference in tibial rotation was −3.8 degrees ER, range −11.1 to 12.4 ER. Only 39% of tibial components were within 3 degrees of the target rotation. A line perpendicular to the midpoint of the tibial PCA was actually medial to the tibial tubercle in 33 knees, and only corresponded to the medial 1/3 of the tibial tubercle in 8 of 41 knees. Conclusions.
INTRODUCTION. In gap balancing technique, we decided the
The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases? A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS).Aims
Patients and Methods
Introduction. Tibial tuberosity and trochlear groove (TT-TG) distance has been investigated for the patients with primary patellofemoral subluxation/dislocation. To date, TT-TG distance after TKA has not been evaluated, and the effect of postoperative TT-TG distance on patellar tracking is unknown. The purpose of the current study was to investigate the effect of TT-TG distance and rotational position of the femoral and tibial components on patellar tilt after TKA. Methods. Consecutive 115 knees for the diagnosis of osteoarthritis were included in the current study. TKA was performed using posterior cruciate ligament sacrificed prosthesis. A total of 17 men and 96 women with an average age of 75.3 years were included at the time of the surgery. Computed tomography (CT) was taken after TKA in full extension. Postoperative TT-TG distance was measured as a reference of surgical epicondylar axis (SEA) of the femur. Patellar tilt was defined as the angle of the patellar component relative to SEA. Femoral and tibial component rotation was measured as the angle relative to SEA and tibial antero-posterior (AP) axis. Tibial AP axis was defined as the line connecting medial one-third of the tibial tuberosity and center of medial-lateral width. Pearson correlation coefficients were calculated to determine the correlations between patellar tilt and TT-TG distance and between patellar tilt and femoral and tibial component rotation. Results. TT-TG distance had significant correlation with patellar tilt (Figure 1; r = 0.254, p = 0.006), whereas