Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 9 - 9
1 Dec 2021
Edwards T Soussi D Gupta S Patel A Liddle A Khan S Cobb J Logishetty K
Full Access

Abstract. Objectives. Non-technical skills including teamwork play a pivotal role in surgical outcomes. Virtual reality is effective at improving technical skills, however there is a paucity of evidence on team-based virtual reality (VR) training. This study aimed to assess if multiplayer virtual reality training was superior to solo training for acquisition of both technical and non-technical skills in learning the complex anterior approach total hip arthroplasty operation. Methods. 10 novice surgeons and 10 novice scrub nurses, were randomised to solo or team virtual reality training to perform anterior approach total hip arthroplasty. Solo participants trained with virtual avatar counterparts, whilst teams trained in pairs (surgeon and scrub nurse). Both groups underwent 5 VR training sessions over 6 weeks. Then, they underwent a real-life assessment in which they performed AA-THA on a high-fidelity model with real equipment in a simulated operating theatre. Teams performed together and solo participants were randomly paired up with a solo player of the opposite role. Videos of the assessment were marked by two blinded expert assessors. Outcomes were procedure time, procedural errors from an expert pre-defined protocol and acetabular component positioning. Non-technical skills were assessed using the NOTECHs II and NOTSS scores. Results. Teams were 28.11% faster than solos in the real world assessment (31.22 minutes ±2.02 vs 43.43 ±2.71, p=0.01), with 34.91% less errors (−15.25 errors ±3.09 vs −23.43 ±1.84, p=0.04). Teams had significantly higher NOTSS and NOTECHS II scores when compared to solos (p<0.001). 8/10 surgeons placed the acetabular component within the target safe zone. Conclusions. Multiplayer training appears to lead to faster surgery with fewer technical errors and the development of superior non-technical skills. VR learnt skills appear to translate to the physical world. This supports the application of multidisciplinary learning to create a more integrated approach to surgical team training


Bone & Joint Open
Vol. 1, Issue 5 | Pages 152 - 159
22 May 2020
Oommen AT Chandy VJ Jeyaraj C Kandagaddala M Hariharan TD Arun Shankar A Poonnoose PM Korula RJ

Aims. Complex total hip arthroplasty (THA) with subtrochanteric shortening osteotomy is necessary in conditions other than developmental dysplasia of the hip (DDH) and septic arthritis sequelae with significant proximal femur migration. Our aim was to evaluate the hip centre restoration with THAs in these hips. Methods. In all, 27 THAs in 25 patients requiring THA with femoral shortening between 2012 and 2019 were assessed. Bilateral shortening was required in two patients. Subtrochanteric shortening was required in 14 out of 27 hips (51.9%) with aetiology other than DDH or septic arthritis. Vertical centre of rotation (VCOR), horizontal centre of rotation, offset, and functional outcome was calculated. The mean followup was 24.4 months (5 to 92 months). Results. The mean VCOR was 17.43 mm (9.5 to 27 mm) and horizontal centre of rotation (HCOR) was 24.79 mm (17.2 to 37.6 mm). Dislocation at three months following acetabulum reconstruction required femoral shortening for offset correction and hip centre restoration in one hip. Mean horizontal offset was 39.72 (32.7 to 48.2 mm) compared to 42.89 (26.7 to 50.6 mm) on the normal side. Mean Harris Hip Score (HHS) of 22.64 (14 to 35) improved to 79.43 (68 to 92). Mean pre-operative shortening was 3.95 cm (2 to 8 cm). Residual limb length discrepancy was 1.5 cm (0 to 2 cm). Sciatic neuropraxia in two patients recovered by six months, and femoral neuropraxia in one hip recovered by 12 months. Mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) was 13.92 (9 to 19). Mean 12-item short form survey (SF-12) physical scores of 50.6 and mental of 60.12 were obtained. Conclusion. THA with subtrochanteric shortening is valuable in complex hips with high dislocation. The restoration of the hip centre of rotation and offset is important in these hips. Level of evidence IV. Femoral shortening useful in conditions other than DDH and septic sequelae. Restoration of hip centre combined with offset to be planned and ensured


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 72 - 81
1 Jan 2020
Downie S Lai FY Joss J Adamson D Jariwala AC

Aims

The early mortality in patients with hip fractures from bony metastases is unknown. The objectives of this study were to quantify 30- and 90-day mortality in patients with proximal femoral metastases, and to create a mortality prediction tool based on biomarkers associated with early death.

Methods

This was a retrospective cohort study of consecutive patients referred to the orthopaedic department at a UK trauma centre with a proximal femoral metastasis (PFM) over a seven-year period (2010 to 2016). The study group were compared to a matched control group of non-metastatic hip fractures. Minimum follow-up was one year.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 75 - 75
1 Oct 2018
Robinson RP Summers S
Full Access

Introduction

Modularity in femoral stem designs allow surgeons to independently control leg length, offset, and femoral version in revision or complex primary THA cases. Initial enthusiasm in these modular stems has been tempered by recognition of modular junction failures. This study evaluates mean 5-year clinical results and survival rates of a 3-part titanium alloy modular femoral implant with unique taper geometries and a metaphyseal plasma spray surface. The current results are presented after pre-market independent fatigue testing performed by Orthopaedic Laboratory (Greenwald) and previously published early clinical results in 2006. Low plasticity burnishing (LPB) was added in 2005 to further strengthen the neck metaphyseal modular junction. The modular stem component is a polished cylindrical splined clothespin design. Our hypothesis is that these unique modular junctions succeed in offering the advantages of modularity without failure at this midterm follow-up period.

Methods

Between May 2010 and July 2016, 32 total hip arthroplasties were performed using a 3-part femoral stem with neck-metaphyseal-stem modular junctions. Surgeries were either the final stage of a two-stage revision for infection, revision THR for loosening, or a revision of a previous non-prosthetic replacement procedure. Patients were entered into an IRB-approved registry and followed with x-rays, HHS, Oxford scores, and patient satisfaction scores. Patients who failed to return for routine follow-up were contacted by phone or email. Two patients had died with their implants intact. Six patients could not be reached for an updated follow-up. One stem was revised for loosening at 33 months due to failed osseointegration in a patient with chronic renal failure. This removed stem was submitted for taper exam and sectioning.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 436 - 442
1 Apr 2018
Choi HG Lee YB Rhyu SH Kwon BC Lee JK

Aims

The aim of this study was to compare the rate of mortality and causes of death in Korean patients who undergo surgery for a fracture of the hip, up to 11 years after the injury, with a control group from the general population.

Materials and Methods

National cohort data from Korean Health Insurance Review and Assessment Service – National Sample Cohort were used. A ratio of 1:4 matched patients with a fracture who underwent surgery (3383, fracture group) between 2003 and 2012, and controls (13 532) were included. The matches were processed for age, gender, income, and region of residence. We also undertook analyses of subgroups according to age and gender. The mean follow-up was 4.45 years (1 to 11).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 120 - 120
1 Mar 2017
Shemesh S Robinson J Overley S Moucha C Chen D
Full Access

Intro

Sciatic nerve injury (SNI) is a rare and potentially devastating complication after total hip arthroplasty (THA). Neural monitoring has been found in several studies to be useful in preventing SNI, but can be difficult to practically implement during surgery. In this study, we examine the results of using a handheld nerve stimulator for intraoperative sciatic nerve monitoring during complex THA requiring limb lengthening and/or significant manipulation of the sciatic nerve.

Methods

We retrospectively reviewed a consecutive series of 11 cases (9 patients, 11 hips) with either severe developmental dysplasia of the hip (Crowe 3–4) or other underlying conditions requiring complex hip reconstruction involving significant leg lengthening and/or nerve manipulation. Sciatic nerve function was monitored intra-operatively with a handheld nerve stimulator by obtaining pre- and post-reduction conduction thresholds during component trialling. The results of nerve stimulation were then used to influence intraoperative decision- making (downsizing components, shortening osteotomy).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 25 - 25
1 Jun 2016
Ferguson D Henckel J Holme T Berber R Matthews W Carrington R Miles J Mitchell P Jagiello J Skinner J Hart A
Full Access

Introduction. Surgical simulation and ‘virtual’ surgical tools are becoming recognised as essential aids for speciality training in Trauma & Orthopaedics, as evidenced by the BOA T&O Simulation Curriculum 2013. 1,2. The current generation of hip arthroplasty simulators, including cadaveric workshops, offers the trainee limited exposure to reproducible real life bony pathology. We developed and implemented a novel training course using pathological dry bone models generated from real patient cases to support senior orthopaedic trainees and new consultants in developing knowledge and hands on skills in complex total hip arthroplasty. Patient/Materials & Methods. A two-day programme for 20 delegates was held at a specialist centre for hip arthroplasty. Three complex femoral and three complex acetabular cases were identified from patients seen at our centre. 3D models were printed from CT scans and dry bone models produced (using a mold-casting process), enabling each delegate to have a copy of each case at a cost of around £30 per case per delegate (Figure 1). The faculty was led by 4 senior Consultant revision hip surgeons. A computerised digitising arm was used to measure cup positioning and femoral stem version giving candidates immediate objective feedback (Figure 2). Candidate experience and satisfaction with the course and models was evaluated with a standardised post-course questionnaire. Results. 91% of respondents rated overall course satisfaction good or very good with 100% stating learning objectives were met or exceeded. 100% of delegates rated the bone model workshop cases as good or very good for the acetabular course, and 88% for the femoral course. Discussion. This course has been shown to enhance learning of surgical techniques and skills in complex hip surgery. Conclusion. We have developed a novel, effective and low cost training simulation method using pathological dry bone models for complex and revision hip arthroplasty which could be developed for other anatomical areas


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1458 - 1463
1 Nov 2013
Won S Lee Y Ha Y Suh Y Koo K

Pre-operative planning for total hip replacement (THR) is challenging in hips with severe acetabular deformities, including those with a hypoplastic acetabulum or severe defects and in the presence of arthrodesis or ankylosis. We evaluated whether a Rapid Prototype (RP) model, which is a life-sized reproduction based on three-dimensional CT scans, can determine the feasibility of THR and provide information about the size and position of the acetabular component in severe acetabular deformities. THR was planned using an RP model in 21 complex hips in five men (five hips) and 16 women (16 hips) with a mean age of 47.7 years (24 to 70) at operation. An acetabular component was implanted successfully and THR completed in all hips. The acetabular component used was within 2 mm of the predicted size in 17 hips (80.9%). All of the acetabular components and femoral stems had radiological evidence of bone ingrowth and stability at the final follow-up, without any detectable wear or peri-prosthetic osteolysis. The RP model allowed a simulated procedure pre-operatively and was helpful in determining the feasibility of THR pre-operatively, and to decide on implant type, size and position in complex THRs.

Cite this article: Bone Joint J 2013;95-B:1458–63.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 34 - 34
1 Sep 2012
Singisetti K Mereddy P Cooke N
Full Access

Introduction. Internal fixation of pertrochanteric fractures is evolving as newer implants are being developed. Proximal Femoral Nail Antirotation (PFNA) is a recently introduced implant from AO/ASIF designed to compact the cancellous bone and may be particularly useful in unstable and osteoporotic hip fractures. This study is a single and independent centre experience of this implant used in management of acute hip fractures. Methods. 68 patients involving 68 PFNA nailing procedures done over a period of 2 years (2007–09) were included in the study. Average follow-up period of patients was 1 year. AO classification for trochanteric fractures was used to classify all the fractures. Radiological parameters including tip-apex distance and neck shaft angle measurement were assessed. Results. Average age of patients included in the study was 80 years. 18 patients died during the follow up period due to non-procedure related causes. Average tip-apex distance was 12.7 mm and radiological fracture union time was 5 months. Revision of short to a long PFNA was needed for periprosthetic fracture of shaft of femur in two patients. Two patients needed a complex total hip replacement eventually and further two patients had removal of the implant due to PFNA blade penetration through the femoral head. Discussion. PFNA is a technically demanding procedure and has a learning curve. Our experience shows that it is a useful implant in unstable pertrochanteric fracture fixation. A close radiological and clinical follow up is recommended due to the risk of late fracture and implant related complications


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 179 - 184
1 Feb 2012
Sutter M Hersche O Leunig M Guggi T Dvorak J Eggspuehler A

Peripheral nerve injury is an uncommon but serious complication of hip surgery that can adversely affect the outcome. Several studies have described the use of electromyography and intra-operative sensory evoked potentials for early warning of nerve injury. We assessed the results of multimodal intra-operative monitoring during complex hip surgery. We retrospectively analysed data collected between 2001 and 2010 from 69 patients who underwent complex hip surgery by a single surgeon using multimodal intra-operative monitoring from a total pool of 7894 patients who underwent hip surgery during this period. In 24 (35%) procedures the surgeon was alerted to a possible lesion to the sciatic and/or femoral nerve. Alerts were observed most frequently during peri-acetabular osteotomy. The surgeon adapted his approach based on interpretation of the neurophysiological changes. From 69 monitored surgical procedures, there was only one true positive case of post-operative nerve injury. There were no false positives or false negatives, and the remaining 68 cases were all true negative. The sensitivity for predicting post-operative nerve injury was 100% and the specificity 100%. We conclude that it is possible and appropriate to use this method during complex hip surgery and it is effective for alerting the surgeon to the possibility of nerve injury.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 448 - 448
1 Apr 2004
Schepers A van der Jagt D
Full Access

Primary total hip replacements are routine procedures with good outcomes. To ensure uniformly good results it is important that a thorough preoperative assessment of the patient is made. The prosthesis best suited to the patient and the pathology must be carefully selected and the optimal surgical technique must take into account patient, pathology and prosthesis parameters.

We discuss patients’ problems such as morbid obesity, the different arthritides and neuromotor abnormalities. Acetabular problems, including dysplastic acetabula and acetabula protrusio, are dealt with in detail. We examine post-traumatic hip pathologies, including retained fracture implants, nonunions and ankyloses. On the femoral side, dysplastic femurs, post-traumatic malunions and post-osteotomies are dealt with.