Advertisement for orthosearch.org.uk
Results 1 - 20 of 222
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 37 - 37
19 Aug 2024
Rego P Mafra I Viegas R Silva C Ganz R
Full Access

Executing an extended retinacular flap containing the blood supply for the femoral head, reduction osteotomy (FHO) can be performed, increasing the potential of correction of complex hip morphologies. The aim of this study was to analyse the safety of the procedure and report the clinical and radiographic results in skeletally mature patients with a minimum follow up of two years. Twelve symptomatic patients (12 hips) with a mean age of 17 years underwent FHO using surgical hip dislocation and an extended soft tissue flap. Radiographs and magnetic resonance imaging producing radial cuts (MRI) were obtained before surgery and radiographs after surgery to evaluate articular congruency, cartilage damage and morphologic parameters. Clinical functional evaluation was done using the Non-Arthritic Hip Score (NAHS), the Hip Outcome Score (HOS), and the modified Harris Hip Score (mHHS). After surgery, at the latest follow-up no symptomatic avascular necrosis was observed and all osteotomies healed without complications. Femoral head size index improved from 120 ± 10% to 100 ± 10% (p<0,05). Femoral head sphericity index improved from 71 ± 10% before surgery to 91 ± 7% after surgery (p<0,05). Femoral head extrusion index improved from 37 ± 17% to 5 ± 6% (p< 0,05). Twenty five percent of patients had an intact Shenton line before surgery. After surgery this percentage was 75% (p<0,05). The NAHS score improved from a mean of 41 ± 18 to 69 ± 9 points after surgery (p< 0,05). The HOS score improve from 56 ± 24 to 83 ± 17 points after surgery (p< 0,05) and the mHHS score improved from 46 ± 15 before surgery to 76 ± 13 points after surgery (p< 0,05). In this series, femoral head osteotomy could be considered as safe procedure with considerable potential to correct hip deformities and improve patients reported outcome measures (PROMS). Level of evidence - Level IV, therapeutic study. Keywords - Femoral head osteotomy, Perthes disease, acetabular dysplasia, coxa plana


The management of severe acetabular bone defects poses a complex challenge in revision hip arthroplasty. Although biological fixation materials are currently dominant, cage has played an important role in complex acetabular revision in the past decades, especially when a biological prosthesis is not available. The purpose of this study is to report the long-term clinical and radiographic results of Paprosky type Ⅲ acetabular bone defects revised with cage and morselized allografts. We retrospectively analyzed 45 patients who underwent revision hip arthroplasty with cage and morselized allografts between January 2007 and January 2019. Forty-three patients were followed up. There were 19 Paprosky type IIIA bone defect patients and 24 Paprosky type IIIB bone defect patients and 7 patients of the 24 were also with pelvic discontinuity. Clinical assessment included Harris Hip Score (HHS) and Short Form-12 (SF-12). Radiographic assessment included cage stability, allografts incorporation, and center of rotation. All patients were followed up with a mean follow-up of 10.6 years, HHS and SF-12 improved significantly at last follow-up in comparison to the preoperative. There were 2 re-revisions, one at 5 years after surgery, another at 13.6 years after surgery. Two patients had nonprogressive radiolucency in zone III and the junction of zone II and zone III at the bone implant interface. Allografts of 40 (93%) cases incorporated fully. The combination of cage and morselized allograft is an alternative option for acetabular revision with Paprosky type III bone defects with satisfactory long-term follow-up results


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 61 - 61
23 Jun 2023
Petrie JR Nepple JJ Thapa S Schoenecker PL Clohisy JC
Full Access

The periacetabular osteotomy (PAO) is a well-described procedure for symptomatic acetabular dysplasia. For severe acetabular deformities, the efficacy of acetabular reorientation remains controversial and the literature on mid to long-term outcomes is limited. The purpose of this study was to analyze average 10-year clinical and radiographic results of the PAO for severe acetabular dysplasia. We retrospectively analyzed a consecutive series of patients undergoing PAO for severe acetabular dysplasia as defined by LCEA < 5˚. Patient demographics, radiographic measurements, modified Harris Hip score (MHHS), UCLA activity, SF-12, and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were assessed. Sixty-eight patients (82 hips; 54 females) with an average age 20.7 and BMI of 24.4 kg/m2 were included. Mean follow-up was follow up was 10.3 years. . The LCEA and ACEA improved a mean of 32.8˚ (8.4˚ to 24.4˚, p<0.0001) and 31.6˚ (−4.9˚ to 26.7˚, p< 0.0001), respectively. MHHS improved an average of 17.5 points (64.6 to 82.3, p<0.0001), WOMAC Pain subscore improved an average of 21.1 points (65.7 to 85.0, p = 0.004), and SF-12 physical improved 11.8 points (from 40.3 to 50.6, p = 0.006). Activity improved as indicated by a 1.5-point increase in the UCLA Activity score (6.4 to 7.9, p=0.005). Six hips (9.1%) converted to THA at average 6.8 years post-PAO. Kaplan-Meier survival analysis with THA as the endpoint was 92% at 15 years (95% confidence interval [CI] (81%–96%). Multivariable linear regression analysis revealed concurrent osteochondroplasty was associated with a decreased risk of PAO failure. PAO is an effective treatment for severe acetabular dysplasia. At average 10.3 years, clinical and radiographic outcomes demonstrate pain relief, improved hip function, and major deformity correction. We observed minimal clinical deterioration over time


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 39 - 39
1 Aug 2021
Rajan A Leong J Singhal R Siney P Shah N Board T
Full Access

Trabecular metal (TM) augments are designed to support an uncemented socket in revision surgery when adequate rim fit is not possible. We have used TM augments in an alternative arrangement, to contain segmental defects to facilitate impaction bone grafting (IBG) and cementation of a cemented socket. However, there is a paucity of literature supporting the use of this technique. We present one of the largest studies to date, reporting early outcomes of patients from a tertiary centre. A single-centre retrospective analytical study of prospectively collected data was performed on patients who had undergone complex acetabular reconstruction using TM augments, IBG and a cemented cup. All patients operated between 2015 and 2019 were included. We identified 105 patients with a mean age of 74yrs. The mean follow-up was 2.3 years(1–5.5yrs). Our primary outcome measure was all-cause revision of the construct. The secondary outcome measures were, Oxford hip score (OHS), radiographic evidence of cup migration/loosening and post-op complications. Eighty-four out of 105 patients belonged to Paprosky grade IIb, IIc or IIIa. Kaplan-Meier survivorship for all-cause revision was 96.36% (CI, 90.58–100.00) at 2 years with 3 failures. Two were due to early infection which required two-stage re-revision. The third was due to post-operative acetabular fracture which was then re-revised with TM augment, bone graft and large uncemented cup. Pre-op and post-op matched OHS scores were available for 60 hips(57%) with a mean improvement of 13 points. Radiographic analysis showed graft incorporation in all cases with no evidence of cup loosening. The mean vertical cup migration was 0.5mm (Range −5 to 7mm). No other complications were recorded. This study shows that reconstruction of large acetabular defects during revision THA using a combination of TM augments to contain the acetabulum along with IBG to preserve the bone stock and a cemented socket is a reliable and safe technique with low revision rates and satisfactory clinical and radiographic results. Long term studies are needed to assess the possibility of preservation and regeneration of bone stock


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1349 - 1353
3 Oct 2020
Park CH Song K Kim JR Lee S

Aims. The hypothesis of this study was that bone peg fixation in the treatment of osteochondral lesions of the talus would show satisfactory clinical and radiological results, without complications. Methods. Between September 2014 and July 2017, 25 patients with symptomatic osteochondritis of the talus and an osteochondral fragment, who were treated using bone peg fixation, were analyzed retrospectively. All were available for complete follow-up at a mean 22 of months (12 to 35). There were 15 males and ten females with a mean age of 19.6 years (11 to 34). The clinical results were evaluated using a visual analogue scale (VAS) and the American Orthopaedic Foot and Ankle Society (AOFAS) score preoperatively and at the final follow-up. The radiological results were evaluated using classification described by Hepple et al based on the MRI findings, the location of the lesion, the size of the osteochondral fragment, and the postoperative healing of the lesion. Results. The mean VAS and AOFAS score improved significantly from 6.3 (4 to 8) and 70.6 (44 to 78) preoperatively to 1.6 (0 to 5) and 91.1 (77 to 100) at the final follow-up, respectively (p < 0.001). The classification on MRI was stage 2a in nine patients, stage 3 in 14, and stage 4 in two. The lesion was located on the posteromedial aspect of the dome of the talus in 19 patients, the anterolateral aspect in five, and the centrolateral aspect in one. The mean size of the fragment was 11.2 mm (5 to 20) horizontally, 10.4 mm (7 to 18) vertically, and 5.2 mm (3 to 10) deep, respectively. The postoperative healing state was good in 19 patients and fair in six. Conclusion. Bone peg fixation for osteochondral lesions of the talus showed satisfactory clinical and radiographic results, without complications. This technique could be a good form of treatment for patients with this condition who have an osteochondral fragment. Cite this article: Bone Joint J 2020;102-B(10):1349–1353


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 15 - 15
1 Feb 2020
Song S Kang S Park C
Full Access

Purpose. Long-term clinical and radiographic results and survival rates were compared between closed-wedge high tibial osteotomy (HTOs) and fixed-bearing unicompartmental knee arthroplasty (UKA) in patients with similar demographics. Methods. Sixty HTOs and 50 UKAs completed between 1992 and 1998 were retrospectively reviewed. There were no significant differences in preoperative demographics. The mean follow-up period was 10.7 ±5.7 years for HTO and 12.0 ±7.1 years for UKA (n.s.). The Knee Society knee and function scores, WOMAC, and range of motion (ROM) were investigated. The mechanical axis and femorotibial angle were evaluated. Kaplan–Meier survival analysis was performed (failure: revision to TKA), and the failure modes were investigated. Results. Most of the clinical and radiographic results were not different at the last follow-up, except ROM; ROM was 135.3 ±12.3° in HTO and 126.8 ±13.3° in UKA (p=0.005). The 5-, 10-, 15-, and 20-year survival rates were 100%, 91.0%, 63.4%, and 48.3% for closed-wedge HTO, respectively, and 90.5%, 87.1%, 70.8%, and 66.4% for UKA (n.s.). The survival rate was higher than that for UKA until 12 years postoperatively but was higher in UKAs thereafter, following a remarkable decrease in HTO. The most common failure mode was degenerative osteoarthritic progression of medial compartment in HTO and femoral component loosening in UKA. Conclusions. Long-term survival did not differ significantly between closed-wedge HTO and fixed-bearing UKA in patients with similar preoperative demographics and knee conditions. The difference in postoperative ROM and failure mode should be considered when selecting a procedure


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 75 - 75
1 Feb 2020
Sadhwani S Picache D Eberle R Shah A
Full Access

INTRODUCTION. In patients presenting with significant ligamentous instability/insufficiency and/or significant varus/valgus deformity of the knee, reproduction of knee alignment and soft tissue stability continues to be a difficult task to achieve. These complex primary total knee arthroplasty (TKA) candidates generally require TKA systems incorporating increasing levels of constraint due to the soft-tissue and/or bone deficiencies. In addition, achievement of “normal” gap symmetry through physiologic kinematics is challenging due to the complexity of the overall correction. Advancements in TKA design have not fully addressed the negative consequences of the increased forces between the degree of component constraint, the femoral box, and the tibial post. The purpose of this early feasibility study was to introduce the design characteristics of a primary TKA system that incorporates progressive constraint kinematics using a low profile trapezoidal femoral box, and to assess the short-term clinical and radiographic results of this patient cohort. METHODS. We retrospectively evaluated 22 consecutive, non-selected, complex primary TKA patients with a minimum of 3-years follow-up and varus deformity of > 20 degrees or valgus deformity of >15 degrees. The Progressive Constraint Kinematics® Knee System (PCK, MAXX Orthopedics, Norristown, PA) was used and provides a variable constraint profile, from high constraint in extension to less constraint in flexion through a novel trapezoidal femoral box. We evaluated patient demographics, pre- and post-operative serial radiography, range of motion (ROM), and total Knee Society Score (KSS – total score). General descriptive statistics and paired t-Test to assess the difference between means at p <0.05 level of significance. RESULTS. The average time to most recent follow-up was 40.5 ±3.5 months (range: 36.0 to 44.0 months). The PCK knee system had 100% survival rate at the most recent follow-up, with no reports of adverse events, subsequent corrective surgery, or revision. The average total KSS improved from 72.7 ±3.2 (range: 68 to 81) pre-operatively to 92.3 ±2.1 (range: 88 to 96) post-operatively (p < 0.001). Full post-operative arc of motion was 0 – 130° and there was no radiographic evidence of composite degradation, aseptic loosening or component malalignment. DISCUSSION/CONCLUSION. The PCK Knee System utilizes a trapezoidal shaped femoral box, where the narrower end is located anteriorly, allowing a valgus/varus tilt of 1–4 degrees and internal/external rotation of 2–7 degrees during flexion, while maintaining necessary soft-tissue constraint during extension. This variable constraint profile allows for fully tensed collaterals in extension, with a slight reduction in collateral tension through flexion. Furthermore, the combination of the condylar anatomy, trapezoidal femoral box and tibial post allows for adequate clearance through full flexion, while facilitating slightly progressive increases in tilt and rotation, thereby maintaining knee kinematics while dampening forces transmitted through the prosthetic composite. From this feasibility study we report promising short-term clinical and radiographic results in the absence of biomechanical failure in complex primary TKA cases. We recommend continuation of the use and further research of the PCK Knee System for complex primary TKA with the ultimate goal of further determining cost effectiveness and intermediate to long-term clinical relevance


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 27 - 27
1 Oct 2019
Martin JR Geary MB Ransone M Macknet D Fehring K Fehring TK
Full Access

Introduction. Tibial component loosening is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include isolated tibial component revision or full component revision. A full component revision is frequently selected by surgeons who are unfamiliar with the existing implant or have a “let's just start over attitude.” This option adds morbidity versus isolated tibial exchange. While isolated tibial exchange has lower morbidity, it is technically more challenging with regard to exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options. Methods. Patients revised for isolated aseptic tibial loosening were identified from 2012–2017. Patients with revision implants, or those revised for infection, instability, osteolysis, or femoral component loosening were excluded. 161 patients met these criteria, 85 patients had an isolated tibial revision and 76 had revision of both components despite having only a loose tibial component. Patient demographics as well as clinical and radiographic outcomes were recorded for each cohort. Results. Patient demographical information, including age, gender, and BMI were statistically similar between the two cohorts. Median follow-up was 3.5 years. Supplemental metaphyseal fixation was used in 22 patients in the isolated tibial cohort and 19 of the full revision cohort. There was a higher incidence of radiographic loosening in the full component revision cohort (10.5% vs. 6.0%; p=0.28). There were five failures requiring revision in the isolated tibial cohort, two for sepsis, one for repeat isolated tibial loosening, one for femoral aseptic loosening, and one for an extensor mechanism disruption. There were eight failures in the full component cohort, three for patellar avascular necrosis, two for sepsis, one for repeat tibial loosening, one for arthrofibrosis, and one for a postoperative wound dehiscence. Conclusion. Isolated tibial revision for aseptic tibial loosening has similar clinical and radiographic results when compared to full component revision. Although no intraoperative complications were identified when revising the femur, there is the potential for complications unique to femoral revision. Femoral component revision for isolated tibial loosening is unnecessary and should be avoided provided adequate ligamentous stability can be obtained. Keywords: Aseptic loosening, Tibial loosening, revision total knee replacement, total knee replacement. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 31 - 31
1 Apr 2019
Torres A Goldberg T Bush JW
Full Access

Introduction. Total knee arthroplasty is a highly effective procedure to improve the quality of life in patients with advanced osteoarthritis. The number of these procedures are expected to grow 174% by 2030. This growth rate is expected to economically strain the health care system. A potential solution to alleviate this problem is the utilization of single use instruments (SUI). Potential advantages of SUI include: improved operating room efficiencies, decreased costs associated with traditional instrument management (sterile processing, shipping), and decreased infection risk. The present study examines the clinical results of SUI compared to standard instrumentation. Furthermore, economic modeling is performed to examine the cost savings that is potentially realized with their use. Materials and Methods. 51 patients receiving a TKA with use of SUI were prospectively compared to 49 patients utilizing standard instrumentation. Knee Society Scores and Radiographic alignment will be evaluated. Adverse events will be recorded. Economic modeling of SUI will be performed in 4 different areas: 1. Decreased infection burden; 2. Operating room logistics; 3. Sterile processing savings; and 4. Instrument logistical savings. Results. The average Pre-operative KSS (Objective/Functional) scores were 48.7/41.6 for the SIU patients compared to 50.2/38.7 for the standard instrumentation patients. Post-operative improvements measured 84.0/72.8 and 83.9/76.4 for the 2 groups respectively. The Pre-operative Hip-Knee-Ankle Angle was 176.2 and 177.0 for the 2 groups. The SUI HKA improved to 179.3 while the standard improved to 178.9. There were no statistical differences between the 2 groups. Furthermore, there were no cases of subsidence, migration, loosening, or infection in either group. There were no SUI procedure abandonments. Economic analysis revealed a decreased risk of Infection burden of $28.08/case. Operating room efficiencies include reduced set-up/take-down time and case efficiency savings/case. This averages $348.14/case. Instrument sterilization savings occur by bypassing the central sterile-processing department completely and models to $700/case. Finally, instrument logistics savings include time and money spent organizing/turning over/shipping instrument sets for cases. This estimate is $112.88/case for a total economic value of $1, 189.10/case. Discussion. In summary, the present study confirms that SUI provides similar clinical and radiographic results to standard instrumentation for TKA. Furthermore, SUI offers significant cost savings/case via potential benefits of reduced risk of infection, increased operating room productivity, and significant tray sterilization and loaner instrumentation cost savings


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 95 - 95
1 Apr 2019
Osman A Tarabichi S Haidar F
Full Access

Introduction. Cementless Total Knee Replacement (TKR) was introduced to improve the longevity of implant; but has yet to be widely adopted because of reports of higher earlier failures in some series. The cementless TKR design has evolved recently and we have been using cementless component – both femoral and tibial on our patients. The long follow-up for fully TKR has been scarce in the literature. The purpose of this study isto investigate the minimum of ten years clinical and radiographic result of cementless titanium component and cementless tantalum component in primary TKR. Material & method. From 2008 to 2010 317 TKR underwent primary total knee with cementless femoral component titanium based (Zimmer Nexgen) and cementless tantalum component monoblock tibial component, The surgery was performed mainly on younger patients - average age was 48 yrs old ranging from 26 yrs old to 62 yrs old. All surgeries were performed by single surgeon. All patients were followed clinically and radiographically for a minimum of 8 yrs. Mean 7.8 years and range from 7 to 9 years. The underlying diagnosis for majority of the cases were degenerative arthritis in 97 of the cases and rheumatoid arthritis on the 3%. Result. We have revised 6 cases − 3 cases were for sepsis. They were revised in 2 stages. And we also revised 5 cases for loosening of femoral component. The tibial component revision for aseptic loosening or osteolysis for an end point for survivorship was a 100% for the tibia monoblock design. There was no radiographic evidence of tibial component loosening or subsidence, or migration at the time of the latest follow-up for tibia monoblock. On the femoral part we documented 16 cases other than those 4 revision for osteolysis, where limited osteolysis happened in some area of the tibial component but it did not affect stability and those has been followed up for a longer term. There was interesting phenomena in some of those cases where bone growth happened around the anterior cortex where it sealed the component entirely. Knee society scores improved from 51 pre-operatively to 94 pre-operatively on the last clinical visit. We had 32 cases where the patientswere able to regain their full mobility flexion of over 150 degrees. Conclusion. Our data clearly shows that the cementless TKR has excellent result as compared to the cemented with a good survival ship at 10 years. The tantalum tibial component shows an excellent survivorship. The femoral component also present reasonably good result but we still faced a few cases of loosening. The functional outcome for the implant with the surgery was satisfactory. With this result we strongly recommend using the cementless implant in young patients. We believe that cementless tibial is totally safe at this point as well as the femoral cementless prosthesis. However, we expect some improvement with the outcome with the femoral component when using the tantalum


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 17 - 17
1 Oct 2018
Garvin KL Otten MR Sveom DS
Full Access

Introduction. Patients under the age of 50 who undergo a total hip arthroplasty (THA) are at high risk for wear-related complications due to their higher activity level. Previous studies have shown that highly crosslinked polyethylene (HXLPE) is more durable with no evidence of loosening compared to conventional polyethylene due to its improved wear characteristics. Unfortunately, there are few studies with long term follow-up of HXLPE in this patient population. The purpose of this study was to evaluate two questions related to this population of patients undergoing THA. First, what were the clinical outcomes for HXLPE in patients 50 years or younger at an average follow-up of 15 years? Second, was osteolysis observed in any of these hips?. Methods. Between November 1999 and April 2005, 105 THAs were performed for 90 patients 50 years of age or younger (mean, 42 years; range, 20–50 years). The mean body mass index (BMI) was 30 kg/m2 (range, 17–51 kg/m2). The mean follow-up was 15.25 years (range, 12–19 years). Eight patients (two bilateral) were lost to follow-up, which left 82 patients with 95 hips for analysis. HXLPE was the acetabular bearing for all hips. Harris Hip Scores were collected from all patients. Radiographs were obtained on all patients to evaluate for wear and osteolysis. Results. Clinical outcomes show excellent results in 81 hips, good results in ten, fair results in three, and a poor result in one hip using the Harris Hip Score. There have been no revisions, infections, or dislocations in this cohort of patients. Fourteen hips developed radiolucent lines in zone I, II, or III of the acetabulum, but none were circumferential. Two hips developed radiolucent lines in zones I and VII in the femur. None of the hips in our study developed osteolysis. Conclusions. The use of HXLPE in patients under the age of 50 who undergo THA shows excellent clinical and radiographic results at an average of 15 years follow-up


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 106 - 106
1 Jun 2018
Abdel M
Full Access

Over the past 30 years, cemented, cementless, and hybrid fixation options have been utilised with various total knee arthroplasty (TKA) implant systems. While cemented components are widely used and considered the most reliable method of fixation, historical results may not be applicable to contemporary patients, who are increasingly younger than 65 years of age. Moreover, the literature is not definitive on which method of TKA fixation obtains the best clinical, functional, and radiographic results. A recent Cochrane meta-analysis on roentgen stereophotogrammetric analysis (RSA) included five randomised clinical trials (RCTs) in 297 participants. The authors observed that cemented fixation of tibial components demonstrated smaller displacement in relation to cementless fixation. However, the risk of future aseptic loosening with uncemented fixation was approximately half that of cemented fixation (risk ratio = 0.47, 95% CI 0.24 to 0.92) with a 16% absolute risk difference between groups. Almost all included studies recorded functional measures of Knee Society and Hospital for Special Surgery knee scores, but the authors of each study found no significant difference between the groups. Recently, highly porous metals have become an attractive fixation option in TKA due to their biomechanical properties. In a large RCT of 397 patients, Pulido et al found that uncemented highly porous metal tibias provided comparably durable fixation and reliable pain relief and restoration of function when compared with traditional cemented modular tibias. While longer term studies are needed, cementless TKAs may be a durable and reliable alternative with highly porous metals, particularly in younger patients


Bone & Joint 360
Vol. 7, Issue 2 | Pages 30 - 33
1 Apr 2018


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 98 - 98
1 Apr 2018
Song S Park C Liang H Kang S Bae D
Full Access

Objective. The purpose of the present study was to compare the clinical and radiographic results after TKA using a patellofemoral design modified prosthesis and its predecessor. The other purpose was to investigate whether the use of the recent prosthesis increase the risk of posterior tibial cortex injury or patellar fracture. Materials and Methods. The clinical and radiographic results of 300 knees which underwent TKA using the Attune®prosthesis (group A) were compared with those in a paired match-control group who underwent TKA using the P.F.C. Sigma® prosthesis (group B). The preoperative demographic data between the 2 groups did not differ significantly. The WOMAC, Feller and Kujala scores, and range of motion (ROM) were compared. The minimal distance between the tibial component stem to posterior tibial cortex, and the remnant patella thickness were compared. Results. The postoperative WOMAC score was better in the group A than in the group B (17.7 vs. 18.8, p=0.004). The postoperative ROM was greater in the group A than in the group B (131.4° vs. 129.0°, p=0.008). The postoperative Feller score was not different, but postoperative Kujala score was better in the group A. The minimal distance between the tibial component stem and posterior tibial cortex was significantly shorter in group A than in the group B (6.3mm vs 7.0mm, p<0.001). The proportion of high risk group for posterior tibial cortical injury, which had the minimal distance less than 4mm, was higher in the group A (20.0% vs 10.7%, p=0.002). The remnant patella was thinner in the group A than in the group B (14.8mm vs 15.7mm, p<0.001). The proportion of high risk group for patella fracture with remnant thickness of <12mm was higher in the group A (7.5% vs 2.1%, p=0.003). Conclusion. When comparing the clinical and radiographic results after TKA using the two prostheses of a design modified prosthesis and its predecessor, TKA using the recent prosthesis provided better satisfactory results. However, the risk of injury in the posterior cortex of the tibial metaphysis or remnant patella should be considered in this design modified prosthesis. Level of Evidence. Level III


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 62 - 62
1 Apr 2018
Lee K Min B Bae K Jung J
Full Access

Purpose. Two-stage revision with the removal of all prosthesis has been considered to be the gold standard for treatment of periprosthetic joint infection. However, removal of well-fixed femoral stem is technically challenging and may cause excessive bone loss. The aim of this study was to compare the results between retention and removal of femoral stem when performing two-stage revision total hip arthroplasty for periprosthetic joint infection. Materials & Methods. From 2007 to 2014, ninety-four patients with infection after hip arthroplasty were treated by using two-stage exchange protocol with temporary articulating spacers. Among them, 38 patients completed the planned second stage reimplantation. Stem was exchanged in 15 patients (group I) and retained in 23 patients (group II). We retrospectively investigated the clinical and radiographic results after an average 39.9 months follow up. Results. The rate of infection control was 86.6% (13/15) in group I, 86.9% (20/23) in group II. There were no statistical differences between the two groups in term of demographics or presence of resistant organism. Conclusion. Retention of well-fixed cementless stem during two-stage revision total hip arthroplasty could be alternative treatment option for the treatment of periprosthetic joint infection


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 41 - 41
1 Apr 2018
Taki N Mitsugi N Mochida Y Yukizawa Y Sasaki Y
Full Access

Introduction. Long term results of Total Hip Arthroplasty (THA) are affected by wear of articulation. Ceramic on ceramic articulation have been used especially for young patients because of its low wear and bio-inert property. However, because of its hardness, it is concerned that ceramic fracture, chipping, or squeaking might happen with ceramic on ceramic articulation. Objective. The purpose of this study was to investigate over 10-years clinical and radiographic results of ceramic bearing cementless THA. Methods. Evaluation was performed in 60 patients (68 joints) who underwent primary cementless THA from May 2003 to April 2007. Mean age at surgery was 59 years. Mean follow up period was 11.2 years. Forty-nine patients were female. Mean BMI at surgery was 24.0 kg/m. 2. Fifty-one patients had osteoarthrosis, 6 patients had osteonecrosis, 2 patients had rheumatoid arthraitis, and 1 patient had PSS. A 28mm-size femoral head was used in all patients. Clinical evaluation was performed with Japanese Orthopaedic Association Hip Score (JOA score). Radiographic results were evaluated with standard bilateral hip radiograph in supine position. Results. Mean clinical score at surgery was 45 (pain: 13/40, ROM: 12/20, gait: 9/20, ADL: 12/20). Mean clinical score at final follow up was 92 (pain: 39/40, ROM: 17/20, gait: 17/20, ADL: 18/20). Pain score was dramatically improved from 13 to 39 (maximum pain score: 40). One stem was revised because of recurrent dislocation. Two other patients experienced one time dislocation during follow up. One stem showed 5mm of subsidence. ALL cups and stems showed bone ingrowth at final follow up. Cortical hypertrophy was seen in 17 joints. However, there was no patient complained thigh pain. Stress shielding was seen in 55 joints (81%). First, second and third degree of stress shielding were seen in 12, 40, and 3 joints, respectively. Most of the female patients who had surgery at the age over 60 years showed second and third degree of stress shielding. There was no measurable wear. No osteolysis was found around the implants. There were no ceramic fracture, chipping, and squeaking. Conclusion. This study demonstrated excellent clinical and radiographic results of ceramic bearing cementless THA. Excellent long term results will be expected with this system


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 97 - 97
1 Apr 2018
Song S Liang H Bae D Yoo M Kim K Park C
Full Access

Introduction. Although total knee arthroplasty (TKA) in end-stage hemophilic arthropathy can reduce the severe joint pain and improve the functional disability, it is technically demanding. In addition, it has generally reported a high rate of complication including periprosthetic joint infection (PJI) and component loosening up to 20%. Although the Knee Society classification system of TKA complication was introduced, the complications of TKA in hemophilic arthropathy has not stratified using this classification system in previous articles to the best of our knowledge. The purpose of this study was to evaluate the mid-term outcomes and complications of TKA in hemophilic arthropathy. Methods. The study retrospectively reviewed 131 consecutive primary TKAs (102 patients) in single institute. The mean patient age was 41.0 years and mean follow-up time was 6.4 years. The clinical and radiographic results were evaluated. The complications were categorized according to the classification system of the Knee Society for TKA complications. Results. The average WOMAC score improved from 66.0 to 24.2. The average flexion contracture significantly decreased from 17.3° to 4.7°, but the average pre and postoperative maximum flexion did not differ (80.9 ° vs. 85.6°). The average mechanical axis was varus 5.2° preoperatively and valgus 0.3° postoperatively. The coronal position of femoral and tibial components and sagittal position of those components were within ±3° in 83.2%, 89.3%, 63.4%, and 73.3%. The complications occurred in 17 knees (13.0%). There were 7 bleeding and hemarthrosis. Five knees were treated with increased amounts of coagulation factor concentrate and two knees were treated with incision and drainage of hematoma. One medial collateral ligament injury of grade 2 required change of postoperative rehabilitation protocol and bracing. Two stiffness of grade 3 required unplanned admission and manipulation under anesthesia. Three deep PJI were treated with 2 stage revision TKA. There were 4 periprosthetic fractures. Three distal femur fractures were treated with open reduction and internal fixation for 3 knees. One patellar fracture was healed with conservative treatment. Conclusions. The mid-term results of TKA in end-stage hemophilic arthropathy were satisfactory with obtaining pain relief, improving function, and decreasing flexion contracture. Bleeding and PJI continues to be a major concern for TKA in patients with hemophilic arthropathy, and risk of periprosthetic fracture has to be taken into account for patient education and appropriate prevention. Level of evidence. Level IV


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 318 - 323
1 Mar 2018
Raiss P Alami G Bruckner T Magosch P Habermeyer P Boileau P Walch G

Aims

The aim of this study was to analyze the results of reverse shoulder arthroplasty (RSA) in patients with type 1 sequelae of a fracture of the proximal humerus in association with rotator cuff deficiency or severe stiffness of the shoulder.

Patients and Methods

A total of 38 patients were included: 28 women and ten men. Their mean age at the time of arthroplasty was 73 years (54 to 91). Before the RSA, 18 patients had been treated with open reduction and internal fixation following a fracture. A total of 22 patients had a rotator cuff tear and 11 had severe stiffness of the shoulder with < 0° of external rotation. The mean follow-up was 4.3 years (1.5 to 10). The Constant score and the range of movement of the shoulder were recorded preoperatively and at final follow-up.

Preoperatively, radiographs in two planes were performed, as well as CT or arthro-CT scans; radiographs were also performed at final follow-up.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 49 - 49
1 Jan 2018
Garcia-Cimbrelo E Garcia-Rey E Sedel L
Full Access

Different pathologies, deformities, bone defects, previous surgeries and polyethylene wear limit the survival of total hip arthroplasty (THA) in young patients. We compare preoperative status and outcome in 171 young and very young patients (207 hips) who underwent a ceramic-on-ceramic THA. Sixty-three (77 hips) were less than 30 years old (group 1) and 108 (130) were between 30 and 40 years old. Mean follow-up was 11.3 years. Two-way ANOVA with repeated measures were used to analyse clinical and radiological changes. Juvenile rheumatoid arthritis (JRA) was the most frequent diagnosis in group 1 and avascular necrosis in group 2. Charnley class type C, low activivity, previous surgery and osteoporotic bone were more frequent in group 1 patients. There were 2 cup revisions for aseptic loosening in group 1 and 4 in group 2. Survivorship analysis at 15 years was 96.7% (95% IC 92.2 a 100) for group 1 and 96.1% (95% IC 92.2 to 100) for group 2 (p=0.749). Despite the worse preoperative status in group 1 patients, clinical outcome was similar in both groups. Severe dysplasia had the worst clinical result and avascular necrosis the best. Patients with Charnley class C and JRA showed the most improvement. Radiographic reconstruction of the abduction angle was worse in group 1 (p=0.02). No osteolysis or complications derived from ceramic use were found. We conclude that despite the worse preoperative status in group 1 patients, clinical and radiographic results were good in both groups of patients who received a ceramic-on-ceramic THA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 46 - 46
1 Dec 2017
Burastero G Cavagnaro L Chiarlone F Riccio G Felli L
Full Access

Aim. Femoral or tibial massive bone defects (AORI F2B-F3 / T2B-T3) are common in septic total knee replacement. Different surgical techniques are described in literature. In our study we show clinical and radiological results associated with the use of tantalum metaphyseal cones in the management of cavitary bone defects in two-stage complex knee revision. Method. Since 2010 we have implanted 70 tantalum metaphyseal cones associated with constrained or semiconstrained knee prostheses in 47 patients. The indication for revision was periprosthetic knee infection (43 cases, 91.5%) or septic knee arthritis (4 patients, 8.5%) with massive bone defect. All cases underwent a two-stage procedure. Patients were screened for main demographic and surgical data. Clinical and radiological analysis was performed in the preoperative and at 3,6 months, 1 years and each year thereafter in the postoperative. The mean follow-up was 31.1 months ± 18.8. No dropout was observed. Results. Objective and subjective functional scores (KSS, OKS) showed a statistically significant improvement from the preoperative to last follow-up (p <0.001). All cones but one (98.6%) showed radiological osteointegration. We did not find any cone-related intraoperative or postoperative mechanical complication with a 100% survival rate when we consider aseptic loosening as cause of revision. Six non progressive radiolucencies were observed. Two septic failures (4.3%) with implant and cone removal were reported. Conclusions. The ideal treatment for cavitary bone defects in two-stage TKA septic revision is still unclear. The use of metaphyseal tantalum cones showed excellent clinical and radiographic results with a low rate of related complications. The main finding of our study is the cone-related infection rate (2.9%) in this particular series of patients. This data is comparable or better than other previous report about this topic with unhomogeneous cohort of patients