Executing an extended retinacular flap containing the blood supply for the femoral head, reduction osteotomy (FHO) can be performed, increasing the potential of correction of complex hip morphologies. The aim of this study was to analyse the safety of the procedure and report the
The management of severe acetabular bone defects poses a complex challenge in revision hip arthroplasty. Although biological fixation materials are currently dominant, cage has played an important role in complex acetabular revision in the past decades, especially when a biological prosthesis is not available. The purpose of this study is to report the long-term
The periacetabular osteotomy (PAO) is a well-described procedure for symptomatic acetabular dysplasia. For severe acetabular deformities, the efficacy of acetabular reorientation remains controversial and the literature on mid to long-term outcomes is limited. The purpose of this study was to analyze average 10-year
Trabecular metal (TM) augments are designed to support an uncemented socket in revision surgery when adequate rim fit is not possible. We have used TM augments in an alternative arrangement, to contain segmental defects to facilitate impaction bone grafting (IBG) and cementation of a cemented socket. However, there is a paucity of literature supporting the use of this technique. We present one of the largest studies to date, reporting early outcomes of patients from a tertiary centre. A single-centre retrospective analytical study of prospectively collected data was performed on patients who had undergone complex acetabular reconstruction using TM augments, IBG and a cemented cup. All patients operated between 2015 and 2019 were included. We identified 105 patients with a mean age of 74yrs. The mean follow-up was 2.3 years(1–5.5yrs). Our primary outcome measure was all-cause revision of the construct. The secondary outcome measures were, Oxford hip score (OHS), radiographic evidence of cup migration/loosening and post-op complications. Eighty-four out of 105 patients belonged to Paprosky grade IIb, IIc or IIIa. Kaplan-Meier survivorship for all-cause revision was 96.36% (CI, 90.58–100.00) at 2 years with 3 failures. Two were due to early infection which required two-stage re-revision. The third was due to post-operative acetabular fracture which was then re-revised with TM augment, bone graft and large uncemented cup. Pre-op and post-op matched OHS scores were available for 60 hips(57%) with a mean improvement of 13 points. Radiographic analysis showed graft incorporation in all cases with no evidence of cup loosening. The mean vertical cup migration was 0.5mm (Range −5 to 7mm). No other complications were recorded. This study shows that reconstruction of large acetabular defects during revision THA using a combination of TM augments to contain the acetabulum along with IBG to preserve the bone stock and a cemented socket is a reliable and safe technique with low revision rates and satisfactory
Aims. The hypothesis of this study was that bone peg fixation in the treatment of osteochondral lesions of the talus would show satisfactory clinical and radiological results, without complications. Methods. Between September 2014 and July 2017, 25 patients with symptomatic osteochondritis of the talus and an osteochondral fragment, who were treated using bone peg fixation, were analyzed retrospectively. All were available for complete follow-up at a mean 22 of months (12 to 35). There were 15 males and ten females with a mean age of 19.6 years (11 to 34). The clinical results were evaluated using a visual analogue scale (VAS) and the American Orthopaedic Foot and Ankle Society (AOFAS) score preoperatively and at the final follow-up. The radiological results were evaluated using classification described by Hepple et al based on the MRI findings, the location of the lesion, the size of the osteochondral fragment, and the postoperative healing of the lesion. Results. The mean VAS and AOFAS score improved significantly from 6.3 (4 to 8) and 70.6 (44 to 78) preoperatively to 1.6 (0 to 5) and 91.1 (77 to 100) at the final follow-up, respectively (p < 0.001). The classification on MRI was stage 2a in nine patients, stage 3 in 14, and stage 4 in two. The lesion was located on the posteromedial aspect of the dome of the talus in 19 patients, the anterolateral aspect in five, and the centrolateral aspect in one. The mean size of the fragment was 11.2 mm (5 to 20) horizontally, 10.4 mm (7 to 18) vertically, and 5.2 mm (3 to 10) deep, respectively. The postoperative healing state was good in 19 patients and fair in six. Conclusion. Bone peg fixation for osteochondral lesions of the talus showed satisfactory
Purpose. Long-term
INTRODUCTION. In patients presenting with significant ligamentous instability/insufficiency and/or significant varus/valgus deformity of the knee, reproduction of knee alignment and soft tissue stability continues to be a difficult task to achieve. These complex primary total knee arthroplasty (TKA) candidates generally require TKA systems incorporating increasing levels of constraint due to the soft-tissue and/or bone deficiencies. In addition, achievement of “normal” gap symmetry through physiologic kinematics is challenging due to the complexity of the overall correction. Advancements in TKA design have not fully addressed the negative consequences of the increased forces between the degree of component constraint, the femoral box, and the tibial post. The purpose of this early feasibility study was to introduce the design characteristics of a primary TKA system that incorporates progressive constraint kinematics using a low profile trapezoidal femoral box, and to assess the short-term
Introduction. Tibial component loosening is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include isolated tibial component revision or full component revision. A full component revision is frequently selected by surgeons who are unfamiliar with the existing implant or have a “let's just start over attitude.” This option adds morbidity versus isolated tibial exchange. While isolated tibial exchange has lower morbidity, it is technically more challenging with regard to exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options. Methods. Patients revised for isolated aseptic tibial loosening were identified from 2012–2017. Patients with revision implants, or those revised for infection, instability, osteolysis, or femoral component loosening were excluded. 161 patients met these criteria, 85 patients had an isolated tibial revision and 76 had revision of both components despite having only a loose tibial component. Patient demographics as well as clinical and radiographic outcomes were recorded for each cohort. Results. Patient demographical information, including age, gender, and BMI were statistically similar between the two cohorts. Median follow-up was 3.5 years. Supplemental metaphyseal fixation was used in 22 patients in the isolated tibial cohort and 19 of the full revision cohort. There was a higher incidence of radiographic loosening in the full component revision cohort (10.5% vs. 6.0%; p=0.28). There were five failures requiring revision in the isolated tibial cohort, two for sepsis, one for repeat isolated tibial loosening, one for femoral aseptic loosening, and one for an extensor mechanism disruption. There were eight failures in the full component cohort, three for patellar avascular necrosis, two for sepsis, one for repeat tibial loosening, one for arthrofibrosis, and one for a postoperative wound dehiscence. Conclusion. Isolated tibial revision for aseptic tibial loosening has similar
Introduction. Total knee arthroplasty is a highly effective procedure to improve the quality of life in patients with advanced osteoarthritis. The number of these procedures are expected to grow 174% by 2030. This growth rate is expected to economically strain the health care system. A potential solution to alleviate this problem is the utilization of single use instruments (SUI). Potential advantages of SUI include: improved operating room efficiencies, decreased costs associated with traditional instrument management (sterile processing, shipping), and decreased infection risk. The present study examines the clinical results of SUI compared to standard instrumentation. Furthermore, economic modeling is performed to examine the cost savings that is potentially realized with their use. Materials and Methods. 51 patients receiving a TKA with use of SUI were prospectively compared to 49 patients utilizing standard instrumentation. Knee Society Scores and Radiographic alignment will be evaluated. Adverse events will be recorded. Economic modeling of SUI will be performed in 4 different areas: 1. Decreased infection burden; 2. Operating room logistics; 3. Sterile processing savings; and 4. Instrument logistical savings. Results. The average Pre-operative KSS (Objective/Functional) scores were 48.7/41.6 for the SIU patients compared to 50.2/38.7 for the standard instrumentation patients. Post-operative improvements measured 84.0/72.8 and 83.9/76.4 for the 2 groups respectively. The Pre-operative Hip-Knee-Ankle Angle was 176.2 and 177.0 for the 2 groups. The SUI HKA improved to 179.3 while the standard improved to 178.9. There were no statistical differences between the 2 groups. Furthermore, there were no cases of subsidence, migration, loosening, or infection in either group. There were no SUI procedure abandonments. Economic analysis revealed a decreased risk of Infection burden of $28.08/case. Operating room efficiencies include reduced set-up/take-down time and case efficiency savings/case. This averages $348.14/case. Instrument sterilization savings occur by bypassing the central sterile-processing department completely and models to $700/case. Finally, instrument logistics savings include time and money spent organizing/turning over/shipping instrument sets for cases. This estimate is $112.88/case for a total economic value of $1, 189.10/case. Discussion. In summary, the present study confirms that SUI provides similar
Introduction. Cementless Total Knee Replacement (TKR) was introduced to improve the longevity of implant; but has yet to be widely adopted because of reports of higher earlier failures in some series. The cementless TKR design has evolved recently and we have been using cementless component – both femoral and tibial on our patients. The long follow-up for fully TKR has been scarce in the literature. The purpose of this study isto investigate the minimum of ten years
Introduction. Patients under the age of 50 who undergo a total hip arthroplasty (THA) are at high risk for wear-related complications due to their higher activity level. Previous studies have shown that highly crosslinked polyethylene (HXLPE) is more durable with no evidence of loosening compared to conventional polyethylene due to its improved wear characteristics. Unfortunately, there are few studies with long term follow-up of HXLPE in this patient population. The purpose of this study was to evaluate two questions related to this population of patients undergoing THA. First, what were the clinical outcomes for HXLPE in patients 50 years or younger at an average follow-up of 15 years? Second, was osteolysis observed in any of these hips?. Methods. Between November 1999 and April 2005, 105 THAs were performed for 90 patients 50 years of age or younger (mean, 42 years; range, 20–50 years). The mean body mass index (BMI) was 30 kg/m2 (range, 17–51 kg/m2). The mean follow-up was 15.25 years (range, 12–19 years). Eight patients (two bilateral) were lost to follow-up, which left 82 patients with 95 hips for analysis. HXLPE was the acetabular bearing for all hips. Harris Hip Scores were collected from all patients. Radiographs were obtained on all patients to evaluate for wear and osteolysis. Results. Clinical outcomes show excellent results in 81 hips, good results in ten, fair results in three, and a poor result in one hip using the Harris Hip Score. There have been no revisions, infections, or dislocations in this cohort of patients. Fourteen hips developed radiolucent lines in zone I, II, or III of the acetabulum, but none were circumferential. Two hips developed radiolucent lines in zones I and VII in the femur. None of the hips in our study developed osteolysis. Conclusions. The use of HXLPE in patients under the age of 50 who undergo THA shows excellent
Over the past 30 years, cemented, cementless, and hybrid fixation options have been utilised with various total knee arthroplasty (TKA) implant systems. While cemented components are widely used and considered the most reliable method of fixation, historical results may not be applicable to contemporary patients, who are increasingly younger than 65 years of age. Moreover, the literature is not definitive on which method of TKA fixation obtains the best
Objective. The purpose of the present study was to compare the
Purpose. Two-stage revision with the removal of all prosthesis has been considered to be the gold standard for treatment of periprosthetic joint infection. However, removal of well-fixed femoral stem is technically challenging and may cause excessive bone loss. The aim of this study was to compare the results between retention and removal of femoral stem when performing two-stage revision total hip arthroplasty for periprosthetic joint infection. Materials & Methods. From 2007 to 2014, ninety-four patients with infection after hip arthroplasty were treated by using two-stage exchange protocol with temporary articulating spacers. Among them, 38 patients completed the planned second stage reimplantation. Stem was exchanged in 15 patients (group I) and retained in 23 patients (group II). We retrospectively investigated the
Introduction. Long term results of Total Hip Arthroplasty (THA) are affected by wear of articulation. Ceramic on ceramic articulation have been used especially for young patients because of its low wear and bio-inert property. However, because of its hardness, it is concerned that ceramic fracture, chipping, or squeaking might happen with ceramic on ceramic articulation. Objective. The purpose of this study was to investigate over 10-years
Introduction. Although total knee arthroplasty (TKA) in end-stage hemophilic arthropathy can reduce the severe joint pain and improve the functional disability, it is technically demanding. In addition, it has generally reported a high rate of complication including periprosthetic joint infection (PJI) and component loosening up to 20%. Although the Knee Society classification system of TKA complication was introduced, the complications of TKA in hemophilic arthropathy has not stratified using this classification system in previous articles to the best of our knowledge. The purpose of this study was to evaluate the mid-term outcomes and complications of TKA in hemophilic arthropathy. Methods. The study retrospectively reviewed 131 consecutive primary TKAs (102 patients) in single institute. The mean patient age was 41.0 years and mean follow-up time was 6.4 years. The
The aim of this study was to analyze the results of reverse shoulder
arthroplasty (RSA) in patients with type 1 sequelae of a fracture
of the proximal humerus in association with rotator cuff deficiency
or severe stiffness of the shoulder. A total of 38 patients were included: 28 women and ten men. Their
mean age at the time of arthroplasty was 73 years (54 to 91). Before
the RSA, 18 patients had been treated with open reduction and internal
fixation following a fracture. A total of 22 patients had a rotator
cuff tear and 11 had severe stiffness of the shoulder with < 0°
of external rotation. The mean follow-up was 4.3 years (1.5 to 10).
The Constant score and the range of movement of the shoulder were
recorded preoperatively and at final follow-up. Preoperatively, radiographs in two planes were performed, as
well as CT or arthro-CT scans; radiographs were also performed at
final follow-up.Aims
Patients and Methods
Different pathologies, deformities, bone defects, previous surgeries and polyethylene wear limit the survival of total hip arthroplasty (THA) in young patients. We compare preoperative status and outcome in 171 young and very young patients (207 hips) who underwent a ceramic-on-ceramic THA. Sixty-three (77 hips) were less than 30 years old (group 1) and 108 (130) were between 30 and 40 years old. Mean follow-up was 11.3 years. Two-way ANOVA with repeated measures were used to analyse clinical and radiological changes. Juvenile rheumatoid arthritis (JRA) was the most frequent diagnosis in group 1 and avascular necrosis in group 2. Charnley class type C, low activivity, previous surgery and osteoporotic bone were more frequent in group 1 patients. There were 2 cup revisions for aseptic loosening in group 1 and 4 in group 2. Survivorship analysis at 15 years was 96.7% (95% IC 92.2 a 100) for group 1 and 96.1% (95% IC 92.2 to 100) for group 2 (p=0.749). Despite the worse preoperative status in group 1 patients, clinical outcome was similar in both groups. Severe dysplasia had the worst clinical result and avascular necrosis the best. Patients with Charnley class C and JRA showed the most improvement. Radiographic reconstruction of the abduction angle was worse in group 1 (p=0.02). No osteolysis or complications derived from ceramic use were found. We conclude that despite the worse preoperative status in group 1 patients,
Aim. Femoral or tibial massive bone defects (AORI F2B-F3 / T2B-T3) are common in septic total knee replacement. Different surgical techniques are described in literature. In our study we show clinical and radiological results associated with the use of tantalum metaphyseal cones in the management of cavitary bone defects in two-stage complex knee revision. Method. Since 2010 we have implanted 70 tantalum metaphyseal cones associated with constrained or semiconstrained knee prostheses in 47 patients. The indication for revision was periprosthetic knee infection (43 cases, 91.5%) or septic knee arthritis (4 patients, 8.5%) with massive bone defect. All cases underwent a two-stage procedure. Patients were screened for main demographic and surgical data. Clinical and radiological analysis was performed in the preoperative and at 3,6 months, 1 years and each year thereafter in the postoperative. The mean follow-up was 31.1 months ± 18.8. No dropout was observed. Results. Objective and subjective functional scores (KSS, OKS) showed a statistically significant improvement from the preoperative to last follow-up (p <0.001). All cones but one (98.6%) showed radiological osteointegration. We did not find any cone-related intraoperative or postoperative mechanical complication with a 100% survival rate when we consider aseptic loosening as cause of revision. Six non progressive radiolucencies were observed. Two septic failures (4.3%) with implant and cone removal were reported. Conclusions. The ideal treatment for cavitary bone defects in two-stage TKA septic revision is still unclear. The use of metaphyseal tantalum cones showed excellent