Advertisement for orthosearch.org.uk
Results 1 - 20 of 41
Results per page:
Bone & Joint 360
Vol. 10, Issue 1 | Pages 4 - 9
1 Feb 2021
White JJE Manktelow ARJ


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1050 - 1057
1 Sep 2019
Lampropoulou-Adamidou K Hartofilakidis G

Aims

To our knowledge, no study has compared the long-term results of cemented and hybrid total hip arthroplasty (THA) in patients with osteoarthritis (OA) secondary to congenital hip disease (CHD). This is a demanding procedure that may require special techniques and implants. Our aim was to compare the long-term outcome of cemented low-friction arthroplasty (LFA) and hybrid THA performed by one surgeon.

Patients and Methods

Between January 1989 and December 1997, 58 hips (44 patients; one man, 43 woman; mean age 56.6 years (25 to 77)) with OA secondary to CHD were treated with a cemented Charnley LFA (group A), and 55 hips (39 patients; two men, 37 women; mean age 49.1 years (27 to 70)) were treated with a hybrid THA (group B), by the senior author (GH). The clinical outcome and survivorship were compared.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1052 - 1056
1 Aug 2013
Lampropoulou-Adamidou K Georgiades G Vlamis J Hartofilakidis G

We evaluated the outcome of 41 consecutive Charnley low-friction arthroplasties (LFAs) performed by a single surgeon in 28 patients aged ≤ 35 years at operation between 23 and 36 years previously. There were 20 women and eight men with a mean age of 32 years (23 to 35) at surgery. Two patients (three hips) were lost to follow-up at 12 and 17 years post-operatively, respectively, and one patient (one hip) died at 13 years post-operatively. These patients were excluded from the final evaluation. The survival rate of the acetabular components was 92.7% (95% confidence interval (CI) 88.7 to 96.7) at ten years, 67.1% (95% CI 59.75 to 74.45) at 20 years and 53.2% (95% CI 45.3 to 61.1) at 25 years. For the femoral component the survival was 95.1% (95% CI 91.8 to 98.5) at ten years, 77.1% (95% CI 73.9 to 80.3) at 20 years and 68.2% (95% CI 60.7 to 75.8) at 25 years. The results indicate that the Charnley LFA remains a reasonable choice in the treatment of young patients and can serve for comparison with newer techniques and implants.

Cite this article: Bone Joint J 2013;95-B:1052–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 601 - 607
1 May 2011
Hartofilakidis G Babis GC Georgiades G Kourlaba G

We studied the effect of trochanteric osteotomy in 192 total hip replacements in 140 patients with congenital hip disease. There was bony union in 158 hips (82%), fibrous union in 29 (15%) and nonunion in five (3%). The rate of union had a statistically significant relationship with the position of reattachment of the trochanter, which depended greatly on the pre-operative diagnosis. The pre-operative Trendelenburg gait substantially improved in all three disease types (dysplasia, low and high dislocation) and all four categories of reattachment position. A persistent Trendelenburg gait post-operatively was noticed mostly in patients with defective union (fibrous or nonunion). Acetabular and femoral loosening had a statistically significant relationship with defective union and the position of reattachment of the trochanter.

These results suggest that the complications of trochanteric osteotomy in total hip replacement for patients with congenital hip disease are less important than the benefits of this surgical approach.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 443 - 448
1 Apr 2011
Malviya A Walker LC Avery P Osborne S Weir DJ Foster HE Deehan DJ

Juvenile idiopathic arthritis (JIA) is a chronic disease of childhood; it causes joint damage which may require surgical intervention, often in the young adult. The aim of this study was to describe the long-term outcome and survival of hip replacement in a group of adult patients with JIA and to determine predictors of survival for the prosthesis. In this retrospective comparative study patients were identified from the database of a regional specialist adult JIA clinic. This documented a series of 47 hip replacements performed in 25 adult patients with JIA. Surgery was performed at a mean age of 27 years (11 to 47), with a mean follow-up of 19 years (2 to 36). The mean Western Ontario and McMaster Universities osteoarthritis index questionnaire (WOMAC) score at the last follow-up was 53 (19 to 96) and the mean Health Assessment Questionnaire score was 2.25 (0 to 3). The mean pain component of the WOMAC score (60 (20 to 100)) was significantly higher than the mean functional component score (46 (0 to 97)) (p = 0.02). Kaplan-Meier survival analysis revealed a survival probability of 46.6% (95% confidence interval 37.5 to 55.7) at 19 years, with a trend towards enhanced survival with the use of a cemented acetabular component and a cementless femoral component. This was not, however, statistically significant (acetabular component, p = 0.76, femoral component, p = 0.45). Cox’s proportional hazards regression analysis showed an implant survival rate of 54.9% at 19 years at the mean of covariates.

Survival of the prosthesis was significantly poorer (p = 0.001) in patients who had been taking long-term corticosteroids and significantly better (p = 0.02) in patients on methotrexate.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 935 - 940
1 Jul 2010
McCalden RW Charron KD Yuan X Bourne RB Naudie DD MacDonald SJ

This was a safety study where the hypothesis was that the newer-design CPCS femoral stem would demonstrate similar early clinical results and micromovement to the well-established Exeter stem. Both are collarless, tapered, polished cemented stems, the only difference being a slight lateral to medial taper with the CPCS stem. A total of 34 patients were enrolled in a single-blinded randomised controlled trial in which 17 patients received a dedicated radiostereometric CPCS stem and 17 a radiostereometric Exeter stem. No difference was found in any of the outcome measures pre-operatively or post-operatively between groups. At two years, the mean subsidence for the CPCS stem was nearly half that seen for the Exeter stem (0.77 mm (−0.943 to 1.77) and 1.25 mm (0.719 to 1.625), respectively; p = 0.032). In contrast, the mean internal rotation of the CPCS stem was approximately twice that of the Exeter (1.61° (−1.07° to 4.33°) and 0.59° (0.97° to 1.64°), respectively; p = 0.048). Other migration patterns were not significantly different between the stems. The subtle differences in designs may explain the different patterns of migration.

Comparable migration with the Exeter stem suggests that the CPCS design will perform well in the long term.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 486 - 488
1 Apr 2010
Wroblewski BM Purbach B Siney PD Fleming PA

Increasing follow-up identifies the outcome in younger patients who have undergone total hip replacement (THR) and reveals the true potential for survival of the prosthesis. We identified 28 patients (39 THRs) who had undergone cemented Charnley low friction arthroplasty between 1969 and 2001. Their mean age at operation was 17.9 years (12 to 19) and the maximum follow-up was 34 years. Two patients (4 THRs) were lost to follow-up, 13 (16 THRs) were revised at a mean period of 19.1 years (8 to 34) and 13 (19 THRs) continue to attend regular follow-up at a mean of 12.6 years (2.3 to 29). In this surviving group one acetabular component was radiologically loose and all femoral components were secure. In all the patients the diameter of the femoral head was 22.225 mm with Charnley femoral components used in 29 hips and C-stem femoral components in ten. In young patients who require THR the acetabular bone stock is generally a limiting factor for the size of the component. Excellent long-term results can be obtained with a cemented polyethylene acetabular component and a femoral head of small diameter.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 720 - 724
1 Jun 2009
Ollivere B Darrah C Brankin RC Donnell ST Walton NP

We report the follow-up at 12 years of the use of the Elite Plus total hip replacement (THR). We have previously reported the results at a mean of 6.4 years. Of the 217 patients (234 THRs), 83 had died and nine had been lost to follow-up. The patients were reviewed radiologically and clinically using the Oxford hip score.

Of the 234 THRs, 19 (8.1%) had required a revision by the final follow-up in all but one for aseptic loosening. Survivorship analysis for revision showed a survival of 93.9% (95% confidence interval (CI) 89.2 to 96.5) at ten years, and of 88.0% (95% CI 81.8 to 92.3) at 12 years. At the final follow-up survival analysis showed that 37% (95% CI 37.3 to 44.7) of the prostheses had either failed radiologically or had been revised. Patients with a radiologically loose femoral component had a significantly poorer Oxford hip score than those with a well-fixed component (p = 0.03). Radiological loosening at 6.4 years was predictive of failure at 12 years.

Medium-term radiographs and clinical scores should be included in the surveillance of THR to give an early indication of the performance of specific implants.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 90 - 90
1 Mar 2009
GAJJAR S Porter M
Full Access

Introduction: We previously reported our results of 98 Charnley Low-Friction Arthroplasty in 76 patients with Paget’s disease of the hip at an average follow-up of 10.4 years. The current report presents the outcome of this procedure at 15 to 30 years. Methods: A total of 98 Charnley low-friction arthroplasties were performed on 76 patients, 27 men (37 hips) and 49 women (61 hips) with an average age of 67.4 years (range 51–79 years). All operations were performed by the trans-trochanteric or antero-lateral approach. Results: When component revision was used as the endpoint, the survivorship of the acetabular component was 93% at 15 years (CI, 81% to 98%), 83% at 20 years (CI, 59% to 93%), 72% at 25 years (CI, 41% to 89%) and 36% at 30 years (CI, 2% to 78%). The survival of the femoral component was 91% at 15 years (CI, 80% to 96%), 84% at 20 years (CI, 60% to 94%), 84% at 25 years (CI, 60% to 94%) and 72% at 30 years (CI, 38% to 89%). The survival of both components was 89% at 15 years (CI, 76% to 95%), 81% at 20 years (CI, 56% to 92%), 81% at 25 years (CI, 56% to 92%) and 81% at 30 years (CI, 56% to 92%). When component failure was used as the endpoint, the survivorship of the acetabular component was 78% at 15 years (CI, 64% to 87%), 66% at 20 years (CI, 48% to 80%), 43% at 25 years (CI, 21% to 62%) and 12% at 30 years (CI, 2% to 32%). The survival of the femoral component was 76% at 15 years (CI, 62% to 85%), 67% at 20 years (CI, 48% to 80%), 47% at 25 years (CI, 25% to 67%) and 7% at 30 years (CI, 1% to 26%). The survival of both components was 74% at 15 years (CI, 59% to 83%), 64% at 20 years (CI, 44% to 78%), 43% at 25 years (CI, 20% to 64%) and 7% at 30 years (CI, 1% to 27%). Discussion and Conclusion: Long term results using Charnley’s Low Friction Arthroplasty achieved in this patient group are comparable to general arthroplasty population. (Previous report: Charnley low-friction arthroplasty for Paget’s disease of the hip. J Arthroplasty. 2000 Feb;15(2):210–9)


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1422 - 1427
1 Nov 2008
Utting MR Raghuvanshi M Amirfeyz R Blom AW Learmonth ID Bannister GC

We have reviewed 70 Harris-Galante uncemented acetabular components implanted as hybrid hip replacements with cemented stems between 1991 and 1995 in 53 patients whose mean age was 40 years (19 to 49). The mean follow-up was for 13.6 years (12 to 16) with no loss to follow-up. We assessed the patients both clinically and radiologically.

The mean Oxford hip score was 20 (12 to 46) and the mean Harris hip score 81 (37 to 100) at the final review. Radiologically, 27 hips (39%) had femoral osteolysis, 13 (19%) acetabular osteolysis, and 31 (44%) radiolucent lines around the acetabular component. Kaplan-Meier survival curves were constructed for the outcomes of revision of the acetabular component, revision of the component and polyethylene liner, and impending revision for progressive osteolysis.

The cumulative survival for revision of the acetabular component was 94% (95% confidence interval 88.4 to 99.7), for the component and liner 84% (95% confidence interval 74.5 to 93.5) and for impending revision 55.3% (95% confidence interval 40.6 to 70) at 16 years.

Uncemented acetabular components with polyethylene liners undergo silent lysis and merit regular long-term radiological review.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 537 - 537
1 Aug 2008
Veysi V Metcalf R Shutt D Gillespie P Stone M
Full Access

Introduction: We present our results of the first 413 Charnley arthroplasties performed by and under the supervision of the senior surgeon, using the posterior approach.

Methods: This is a prospective study of clinical and radiographic outcomes. Four hundred and thirteen hip replacements were performed in 380 patients (215 female and 165 male) between 1992 and 1996. The mean age at the time of primary surgery was 67 years (28 – 91 years).

Results: The primary aetiology in 297 of the hips was osteoarthritis. Eighty-two had rheumatoid arthritis.

Eleven patients (3%) had one or more episodes of dislocation.

There were 22 revisions. Three of the revisions were carried out for infection, and a further 2 for recurrent dislocation. Aseptic loosening was the cause of failure in the remaining 17.

Thirty three patients (36 hips, 9%) could not be traced at the time of the final follow-up. There was significant and maintained improvement in pain and function scores.

One hundred and thirty eight patients (146 hips) had died at the time of the final follow-up.

The best and worst case survivorship figures at 10 years were 93 +/− 2% and 83 +/− 2%, and those at 14 years were 88 +/− 4% and 78 +/− 4%, respectively, with revision for any reason as the end-point.

Discussion: Excellent results for the Charnley hip are possible using the posterior approach and surgeons of varying experience. The results presented compare favourably with the published data and confirm that the Charnley remains the gold-standard for longevity in hip arthroplasty. The newer and more costly implants not only need to reproduce these results but also match the cost effectiveness of this prosthesis.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 311 - 311
1 Jul 2008
Malik M Wadia F Porter M
Full Access

Total hip replacement is a successful and reliable procedure for the relief of pain, but the results achieved have been reported to be less successful in younger patients who tend to be relatively more active and place greater demands on prostheses than older patients.

Between 1966 and 1978, 226 Charnley low friction arthroplasties (LFAs) were implanted in young patients with an average age at operation of 31.7 years. Initial results were presented at an average of 19.7 years. We have performed a further retrospective analysis of this cohort at 10 years on from the time of data collection of the original study. Of the original cohort, 112 patients are alive and either under follow-up at our hospital or have been traced to other hospitals. 16 have been lost to follow-up. Mean follow-up was 26.4 years. At the time of final follow-up or death, rate of aseptic loosening of the stem was approximately 80%. Acetabular components proved to be less successful with less than 60% remaining well fixed. Differences in survival were apparent between subgroups with differing original pathology with stem survival greater in those with DDH as opposed to rheumatoid or degenerative arthritis and the opposite being true for socket survival.

This study adds to the available knowledge of the longevity of cemented total hip replacement as performed with unsophisticated cementation techniques and how it may perform in differing patients groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1015 - 1018
1 Aug 2007
Wroblewski BM Siney PD Fleming PA

We studied survival to 38 years after Charnley low-friction arthroplasty of the hip. We used revision as an end-point, while adopting a policy of regular follow-up and early revision for radiological changes alone if indicated. Between November 1962 and June 2005, 22 066 primary low-friction arthroplasties (17 409 patients) had been performed at Wrightington Hospital by more than 330 surgeons. By June 2006, 1001 (4.5%) hips had been revised and 1490 patients (2662 hips, 12%) had died. At 31 years, where a minimum of 40 hips were still attending follow-up, survival with revision for infection as an endpoint was 95%, for dislocation 98%, for a fractured stem 88.6%, for a loose stem 72.5% and for a loose acetabular component 53.7%. Wear and loosening of the ultra-high-molecular-weight polyethylene acetabular component were the main long-term problems. We conclude that regular follow-up after hip replacement is essential and that all operative findings should be recorded at revision


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 730 - 735
1 Jun 2007
Derbyshire B Porter ML

We performed a three-year radiostereometric analysis (RSA) study of the Elite Plus femoral component on 25 patients undergoing primary total hip replacement. Additional assessments and measurements from standard radiographs were also made.

Subsidence of the stem occurred at the cement-stem interface. At 36 months the subsidence of the stem centroid was a mean of 0.30 mm (0.02 to 1.28), and was continuing at a slow rate. At the same time point, internal rotation and posterior migration of the femoral head had ceased. One stem migrated excessively and additional assessments suggested that this was probably due to high patient demand.

The failure rate of 4% in our study is consistent with data from arthroplasty registers but contrasts with poor results from another RSA study, and from some clinical studies. We believe that the surgical technique, particularly the use of high-viscosity cement, may have been an important factor contributing to our results.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 449 - 454
1 Apr 2007
Kim Y Kim J Yoon S

We studied prospectively the long-term results of the Charnley Elite-Plus femoral stem in 184 consecutive young patients (194 hips). There were 130 men and 54 women with a mean age of 49.1 years (21 to 60). The predominant diagnosis was osteonecrosis of the femoral head (63.6%, 117 patients). Clinical and radiological evaluation was undertaken at each follow-up. The mean follow-up was 11.2 years (10 to 12).

The mean pre-operative Harris hip score was 43.4 (12 to 49) which improved to 91 (59 to 100) at the final follow-up. The survival of the femoral stem at 12 years was 99% with revision as the end-point. The mean annual linear wear of the polyethylene liner was 0.17 mm (0.13 to 0.22). The prevalence of acetabular osteolysis was 10.8% (21 hips) and osteolysis of the calcar femorale 12.9% (25 hips).

A third-generation cementing technique, accurate alignment of the stem and the use of a 22 mm zirconia head were important factors in the prevention of aseptic loosening of the Elite Plus femoral stem in these high-risk young patients.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 360 - 360
1 Sep 2005
Mullins M Norbury W Dowell J Heywood-Waddington M
Full Access

Introduction and Aims: We present the results of 228 consecutive Charnley low-friction arthroplasties, inserted in 193 patients between July 1972 and December 1976. Unusually for this time, all hips were inserted by the posterior approach without trochanteric osteotomy. Method: All patients were enrolled into a prospective study and pre- and post-operative findings recorded. This series was reviewed in 1985 and once again in 2002. The survivors were scored clinically using the Merle d’Aubigné-Postel score with a mean value of 12. The reason for revision was also recorded and analysed. Results: The pre- and peri-operative findings are similar to contemporary series. Due to our stable population, only two patients were lost to follow-up. Our survivor-ship results show a 10-year survival of 93%, deteriorating to a 30-year survival of 73%. Conclusion: Overall our results are comparable to other studies and really vindicate the choice of approach, which at the time was a source of some controversy


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 498 - 503
1 May 2004
Wroblewski BM Siney PB Fleming PA

Since wear and loosening of the ultra-high-molecular-weight polyethylene cup are factors which limit the life of an arthroplasty we have attempted to identify factors associated with either low wear (0.02 mm/year or less) or high wear (0.2 mm/year or more). In a series of 1434 Charnley low-friction arthroplasties (1092 patients) 190 (13.2%) showed low wear while 149 (10.4%) showed high wear. We used chi-squared test to assess the significance of various factors. The significant factors of the low-wear group were female gender (p = 0.042), rheumatoid arthritis (p = 0.014), Charnley grade C (p = 0.03) and varus position of the stem (p = 0.003). The use of acetabular cement pressurisation (p = 0.07) and medialisation of the cup (p = 0.07) approached significance. In the high-wear group there was a predominance of men (p = 0.042) with osteoarthritis (p = 0.006) as the underlying hip pathology, and the stem in a valgus position (p = 0.023). Support of the cup by the rim of the acetabulum approached significance (p = 0.07). There was no statistical significance between the two groups for revision for aseptic loosening of the stem or fracture of the stem (p = 0.49). There was a highly significant difference (p < 0.0001) between the two groups for revision for wear and aseptic loosening of the cup, 5.3% compared with 39%. Changes in the cup geometry are probably sufficient to explain the increasing incidence of loosening and revisions with the increasing depth of penetration of the cup. There is much to be gained from the use of a low-wearing ceramic-ultra-high-molecular-weight combination. Tissue reaction to the polyethylene particles cannot be the cause of aseptic loosening of the stem


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 70 - 70
1 Jan 2004
Wroblewski BM Siney PD Fleming PA
Full Access

Since wear and loosening of the ultra high molecular weight polyethylene is the one factor limiting the life of the arthroplasty we set out to identify factors associated with either low wear 0.02 mm/year or less, or high wear 0.2 mm/year or more. In a group of 1092 patients, 1434 Charnley low-friction arthroplasties 190 (13.2%) showed low wear while 149 (10.4%) showed high wear. We used Chi square test to assess the significance. The characteristics of the low wear group were: female gender (p=0.042) Rheumatoid arthritis (p= 0.014), Charnley category “C” patients (p=0.03) and varus position of the stem (p=0.003) The use of acetabular cement pressurization (p=0.07) and medialization of the cup (p=0.07) approached significance. In the high wear group there was a predominance of males (p=0.042) with primary arthritis (p=0.006) as the underlying hip pathology, and the stem in valgus position (p=0.023). Rim position of the cup was approaching significance (p=0.07). There was no statistical significance between the two groups for revision for aseptic stem loosening or stem fracture (p= 0.49). There was a highly significant difference (p< 0.0001) between the two groups for revision for wear and aseptic cup loosening: 5.3% against 40%. Changes in the cup geometry are sufficient to explain the increasing incidence with depth of cup penetration. There is much to be gained from the use of low wearing ceramic – ultra high molecular weight combination. Tissue reaction to the plastic particles cannot be the cause of stem loosening


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 20 - 20
1 Jan 2003
Wroblewski B Siney PD Fleming PA
Full Access

Ultra high molecular weight polyethylene (UHMWPE) was introduced into clinical practice by Charnley in November 1962 and has remained the standard material for the hip and other total joint arthroplasties. Wear of the UHMWPE cup, although studied from the beginning, did not appear to be a clinical problem although Charnley suspected that this would be so in the long term. A review of the outcome of the Charnley low-friction arthroplasty in patients under the age of 40 years at the time of the operation has shown that the incidence of cup migration was exponentially related to the depth of cup penetration. A prospective study using 22.225 mm alumina ceramic (Al 20 3 ) head articulating with cross linked polyethylene was set up with the initial penetration of 0.2 – 0.4 mm in about 2.5 years with no further penetration. The clinical results mirrored closely the experimental results obtained with the identical set of materials and design. The clinical results have now reached 14 year follow-up and the initial total penetration of 0.2 – 0.4mm has remained unchanged. Review of long term results of the Charnley LFA has shown a mean penetration rate of 0.1 mm/year (0.02 – 0.6). With a mean penetration rate of 0.1 mm/year, the revision rate for cup wear and loosening in patients under the age of 50 at the time of the LFA, and with a follow-up to 32 years, is in the region of 10%. If the penetration rate remained at 0.02 mm/year or less then no cups have been revised for aseptic loosening. Ceramic / UHMWPE articulation is the next stage of evolution of the Charnley LFA. A prospective study using zirconia 22.225 mm head is approaching 7 year follow-up in over 1000 cases


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 22 - 22
1 Jan 2003
Wroblewski B Siney PD Fleming PA
Full Access

A prospective study of Charnley low friction arthroplasty in patients under the age of 51 at the time of surgery. 1092 patients, 668 women and 424 men, mean age 41 years (12–51) at the time of surgery had 1434 Charnley low-friction arthroplasties carried out between November 1962 and December 1990. At mean follow-up 14.2 years (1 – 32), 742 patients (973 hips) are still attending and patients’ satisfaction with the outcome is 96.2%. Survivorship was 95.24% at 10 years and 58.67% at 27 years. Patients who had had previous hip surgery had revision rate 24.8% compared with 14.1%. Patients with rheumatoid arthritis had fewer revisions than those with developmental hip dysplasia or primary osteoarthritis. Large 43 mm diameter cup gave lower revisions for aseptic cup loosening as compared with 40mm cup. Presence and preservation of subchondral plate, rim support compared to medialization of the cup, use of acetabular cement pressurizer and the reduced diameter neck (10mm) all made a contribution to reducing the incidence of revisions for aseptic cup loosening. Closing the medullary canal with bone block reduced the incidence of aseptic stem loosening. Use of the brace reamers did not affect the outcome and there appears to have been no advantage with the flanged stem. The long-term problem was the increasing incidence of revisions for aseptic cup loosening. This was exponentially related to the depth of cup penetration by the head of the femoral component. The long term clinical results of the Charnley LFA remain excellent even in young patients. Rim support of the cup, preservation of the subchondral bone of the acetabulum, cup flange and pressurising of the acetabular cement all make a significant contribution. Distal closure of the medullary canal and central position of the stem are of benefit, but reaming the medullary canal to cortex must be avoided. The long-term problem has been highlighted again as: wear and cup loosening