Advertisement for orthosearch.org.uk
Results 1 - 20 of 2485
Results per page:
Bone & Joint Open
Vol. 5, Issue 8 | Pages 671 - 680
14 Aug 2024
Fontalis A Zhao B Putzeys P Mancino F Zhang S Vanspauwen T Glod F Plastow R Mazomenos E Haddad FS

Aims

Precise implant positioning, tailored to individual spinopelvic biomechanics and phenotype, is paramount for stability in total hip arthroplasty (THA). Despite a few studies on instability prediction, there is a notable gap in research utilizing artificial intelligence (AI). The objective of our pilot study was to evaluate the feasibility of developing an AI algorithm tailored to individual spinopelvic mechanics and patient phenotype for predicting impingement.

Methods

This international, multicentre prospective cohort study across two centres encompassed 157 adults undergoing primary robotic arm-assisted THA. Impingement during specific flexion and extension stances was identified using the virtual range of motion (ROM) tool of the robotic software. The primary AI model, the Light Gradient-Boosting Machine (LGBM), used tabular data to predict impingement presence, direction (flexion or extension), and type. A secondary model integrating tabular data with plain anteroposterior pelvis radiographs was evaluated to assess for any potential enhancement in prediction accuracy.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 36 - 36
7 Aug 2024
Salimi H Terai H Toyoda H Tamai K Nakamura H Shimada N
Full Access

Background. Surgical treatment of AIS includes several purposes such as arrest deformity progression through a solid fusion, obtain a permanent correction of the deformity and others. Objectives. To evaluate the improvement of sagittal spinopelvic parameters and clinical outcomes in patients with adolescent idiopathic scoliosis 2 years after corrective surgery. Methods. Radiological and clinical data of 134 consecutive scoliosis patients including 11 boys and 124 girls with the average age of 15.37 years, with AIS Lenke 1, 2, 3, 4, 5 or 6 were included in this retrospective study with 2-year follow-up. Whole spine anterior/posterior and lateral Xray, CT scan and MRI were taken preoperatively, immediately after surgery, at 3 months and 2 years after corrective surgery. Radiological parameters were evaluated and compared pre and post operatively. Result. In coronal plan, significant reduction was observed in main curve, proximal curve and distal curve P<0.001, 2 years after corrective surgery. Meanwhile, the translation of apex vertebra decreased p<0.001. But sagittal profile of the patients did not show obvious changes such as LL, TK. The pelvic parameters indicated that PI was 50.6 degrees, PT was 13.8, SS was 37.0 and TPA was 47.5 degrees preoperatively. Vertebral body height increased dramatically just after surgery and showed further in the last follow up. Conclusion. The changes in coronal plan was significant 2 years after correction surgery for AIS patients and were not correlated with restoration of sagittal profile. Conflict of interest. None. Sources of funding. None


Bone & Joint 360
Vol. 13, Issue 4 | Pages 5 - 6
2 Aug 2024
Ollivere B


Bone & Joint Open
Vol. 5, Issue 8 | Pages 628 - 636
2 Aug 2024
Eachempati KK Parameswaran A Ponnala VK Sunil A Sheth NP

Aims

The aims of this study were: 1) to describe extended restricted kinematic alignment (E-rKA), a novel alignment strategy during robotic-assisted total knee arthroplasty (RA-TKA); 2) to compare residual medial compartment tightness following virtual surgical planning during RA-TKA using mechanical alignment (MA) and E-rKA, in the same set of osteoarthritic varus knees; 3) to assess the requirement of soft-tissue releases during RA-TKA using E-rKA; and 4) to compare the accuracy of surgical plan execution between knees managed with adjustments in component positioning alone, and those which require additional soft-tissue releases.

Methods

Patients who underwent RA-TKA between January and December 2022 for primary varus osteoarthritis were included. Safe boundaries for E-rKA were defined. Residual medial compartment tightness was compared following virtual surgical planning using E-rKA and MA, in the same set of knees. Soft-tissue releases were documented. Errors in postoperative alignment in relation to planned alignment were compared between patients who did (group A) and did not (group B) require soft-tissue releases.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 817 - 825
1 Aug 2024
Borukhov I Ismailidis P Esposito CI LiArno S Lyon J McEwen PJ

Aims. This study aimed to evaluate if total knee arthroplasty (TKA) femoral components aligned in either mechanical alignment (MA) or kinematic alignment (KA) are more biomimetic concerning trochlear sulcus orientation and restoration of trochlear height. Methods. Bone surfaces from 1,012 CT scans of non-arthritic femora were segmented using a modelling and analytics system. TKA femoral components (Triathlon; Stryker) were virtually implanted in both MA and KA. Trochlear sulcus orientation was assessed by measuring the distal trochlear sulcus angle (DTSA) in native femora and in KA and MA prosthetic femoral components. Trochlear anatomy restoration was evaluated by measuring the differences in medial, lateral, and sulcus trochlear height between native femora and KA and MA prosthetic femoral components. Results. Femoral components in both MA and KA alignments exhibited a more valgus DTSA compared to native femora. However, DTSA deviation from native was significantly less in KA than in MA (4.8° (SD 2.2°) vs 8.8° (SD 1.8°); p < 0.001). DTSA deviation from native orientation correlated positively with the mechanical lateral distal femoral angle (mLDFA) in KA and negatively in MA (r = 0.53, p < 0.001; r = -0.18, p < 0.001). Medial trochlear height was not restored with either MA or KA, with MA resulting in lower medial trochlear height than KA in the proximal 20% of the trochlea. Lateral and sulcus trochlear height was not restored with either alignment in the proximal 80% of the trochlea. At the terminal arc point, KA replicated sulcus and lateral trochlear height, while MA led to over-restoration. Conclusion. Femoral components aligned in KA demonstrated greater biomimetic qualities than those in MA regarding trochlear sulcus orientation and trochlear height restoration, particularly in valgus femora. Variability across knees was observed, warranting further research to evaluate the clinical implications of these findings. Cite this article: Bone Joint J 2024;106-B(8):817–825


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 792 - 801
1 Aug 2024
Kleeman-Forsthuber L Kurkis G Madurawe C Jones T Plaskos C Pierrepont JW Dennis DA

Aims

Spinopelvic pathology increases the risk for instability following total hip arthroplasty (THA), yet few studies have evaluated how pathology varies with age or sex. The aims of this study were: 1) to report differences in spinopelvic parameters with advancing age and between the sexes; and 2) to determine variation in the prevalence of THA instability risk factors with advancing age.

Methods

A multicentre database with preoperative imaging for 15,830 THA patients was reviewed. Spinopelvic parameter measurements were made by experienced engineers, including anterior pelvic plane tilt (APPT), spinopelvic tilt (SPT), sacral slope (SS), lumbar lordosis (LL), and pelvic incidence (PI). Lumbar flexion (LF), sagittal spinal deformity, and hip user index (HUI) were calculated using parameter measurements.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 865 - 870
1 Aug 2024
Broida SE Sullivan MH Rose PS Wenger DE Houdek MT

Aims

Venous tumour thrombus (VTT) is a rare finding in osteosarcoma. Despite the high rate of VTT in osteosarcoma of the pelvis, there are very few descriptions of VTT associated with extrapelvic primary osteosarcoma. We therefore sought to describe the prevalence and presenting features of VTT in osteosarcoma of both the pelvis and the limbs.

Methods

Records from a single institution were retrospectively reviewed for 308 patients with osteosarcoma of the pelvis or limb treated between January 2000 and December 2022. Primary lesions were located in an upper limb (n = 40), lower limb (n = 198), or pelvis (n = 70). Preoperative imaging and operative reports were reviewed to identify patients with thrombi in proximity to their primary lesion. Imaging and histopathology were used to determine presence of tumour within the thrombus.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 783 - 791
1 Aug 2024
Tanaka S Fujii M Kawano S Ueno M Nagamine S Mawatari M

Aims

The aim of this study was to determine the clinical outcomes and factors contributing to failure of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, for advanced osteoarthritis secondary to hip dysplasia.

Methods

We reviewed patients with Tönnis grade 2 osteoarthritis secondary to hip dysplasia who underwent TOA between November 1998 and December 2019. Patient demographic details, osteotomy-related complications, and the modified Harris Hip Score (mHHS) were obtained via medical notes review. Radiological indicators of hip dysplasia were assessed using preoperative and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan-Meier product-limited method. A multivariate Cox proportional hazards model was used to identify predictors of failure.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims

Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up.

Methods

This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36).


Bone & Joint Research
Vol. 13, Issue 6 | Pages 294 - 305
17 Jun 2024
Yang P He W Yang W Jiang L Lin T Sun W Zhang Q Bai X Sun W Guo D

Aims

In this study, we aimed to visualize the spatial distribution characteristics of femoral head necrosis using a novel measurement method.

Methods

We retrospectively collected CT imaging data of 108 hips with non-traumatic osteonecrosis of the femoral head from 76 consecutive patients (mean age 34.3 years (SD 8.1), 56.58% male (n = 43)) in two clinical centres. The femoral head was divided into 288 standard units (based on the orientation of units within the femoral head, designated as N[Superior], S[Inferior], E[Anterior], and W[Posterior]) using a new measurement system called the longitude and latitude division system (LLDS). A computer-aided design (CAD) measurement tool was also developed to visualize the measurement of the spatial location of necrotic lesions in CT images. Two orthopaedic surgeons independently performed measurements, and the results were used to draw 2D and 3D heat maps of spatial distribution of necrotic lesions in the femoral head, and for statistical analysis.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 21 - 21
17 Jun 2024
Jamjoom B Malhotra K Patel S Cullen N Welck M Clough T
Full Access

Background. Ankle and hindfoot fusion in the presence of large bony defects represents a challenging problem. Treatment options include acute shortening and fusion or void filling with metal cages or structural allograft, which both have historically low union rates. Impaction grafting is an alternative option. Methods. A 2 centre retrospective review of consecutive series of 32 patients undergoing hindfoot fusions with impaction bone grafting of morselised femoral head allograft to fill large bony void defects was performed. Union was assessed clinically and with either plain radiography or weightbearing CT scanning. Indications included failed total ankle replacement (24 patients), talar osteonecrosis (6 patients) and fracture non-union (2 patients). Mean depth of the defect was 29 ±10.7 mm and mean maximal cross-sectional area was 15.9 ±5.8 cm. 2. Tibiotalocalcaneal (TTC) arthrodesis was performed in 24 patients, ankle arthrodesis in 7 patients and triple arthrodesis in 1 patient. Results. Mean age was 57 years (19–76 years). Mean follow-up of 22.8 ±8.3 months. 22% were smokers. There were 4 tibiotalar non-unions (12.5%), two of which were symptomatic. 10 TTC arthrodesis patients united at the tibiotalar joint but not at the subtalar joint (31.3%), but only two of these were symptomatic. The combined symptomatic non-union rate was 12.5%. Mean time to union was 9.6 ±5.9 months. One subtalar non-union patient underwent re-operation at 78 months post-operatively after failure of metalwork. Two (13%) patients developed a stress fracture above the metalwork that healed with non-operative measures. There was no bone graft collapse with all patients maintaining bone length. Conclusion. Impaction of morselised femoral head allograft can be used to fill large bony voids around the ankle and hindfoot when undertaking arthrodesis, with rapid graft incorporation and no graft collapse despite early loading. This technique offers satisfactory union outcomes without the need for shortening or synthetic cages


Bone & Joint Open
Vol. 5, Issue 6 | Pages 489 - 498
12 Jun 2024
Kriechling P Bowley ALW Ross LA Moran M Scott CEH

Aims

The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs).

Methods

All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 20 - 20
10 Jun 2024
Somanathan A Sharp B Saedi F Loizou C Brown R Kendal A
Full Access

Introduction. Primary ankle arthroplasty (TAR) is increasingly used to treat end-stage ankle arthritis. Reported revision rates of TAR vary from 8.5% to 11.1% at 9 years. Revision surgery remains technically challenging with options ranging from simple joint debridement to tibio-talar-calcaneal fusion. The efficacy of these procedures remains unclear and there is no consensus on optimal revision options. Methods. A retrospective cohort study was performed of all patients undergoing surgery for a failed primary TAR at the Nuffield Orthopaedic Centre (2004–2021). TAR failure was determined by clinical assessment, serial radiographs and CT scans. Primary outcome measures included type and time of index surgery post TAR. Secondary outcomes included frequency of re-operations, post-operative complications, patient reported outcomes and union rate (for revision arthrodesis procedures). Results. 70 failed TARs in 69 patients (35M:34F, mean 65.7 years, s.d.=11.6) underwent re-operation a mean of 6.24 years (range 1–30) post primary. In total, 107 operations were performed including revision fusion (n=50), revision arthroplasty (n=14), bearing exchange (n=9) and joint clearance (n=9). The overall revision fusion union rate was 73.5% over a mean of 12.5 months (s.d.=7.6). 16/23 (69.6%) Tibio-Talo-Calcaneal and 9/12 (75%) ankle fusions (previous subtalar/triple fusion) using a hindfoot nail united over a mean 11.4 months (s.d.=6.0) and 15 months (s.d.=9.48) respectively. Only 64% of ankle fusions using screws alone united (mean=10.6 months, s.d.=8.14). The average post-operative MOXFQ score was 28.3 (s.d.=19.3). 73% said the operation improved their function and would recommend it to a friend/family member. Conclusion. Despite low post-operative MOXFQ scores, over 70% of patients were satisfied with re-operation for a failed TAR. Over 26% of all TAR revision fusions fail to unite with the highest non-union rates observed post ankle arthrodesis with screws alone (36.4%)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 21 - 21
10 Jun 2024
Gordon C Raglan M Dhar S Lee K
Full Access

Objective. The purpose of this study was to determine the outcomes of revision ankle replacements, using the Invision implant and impaction allograft for massive talar dome defects following primary ankle replacement failure. Outcomes were assessed in terms of bone graft incorporation; improvement in patient reported outcome measures (PROMs); and survivorship of the revision ankle arthroplasty. Methods. A retrospective review of prospectively collected data identified eleven patients who had massive bone cysts and underwent revision of a failed primary total ankle replacement to the Invision revision system, combined with impaction grafting using morselized femoral head allograft. These revisions occurred at a single high volume ankle arthroplasty centre. Computed tomography (CT) scans were used to assess bone graft incorporation and the Manchester-Oxford Foot Questionnaire (MOXFQ) and EQ-5D scores were used pre and post operatively to assess PROMs. Results. The mean follow up was 18 months (12–48months). In all eleven patients, improvement was reported in the post-operative MOXFQ and EQ-5D scores. CT scans showed bone graft incorporation in all cases. None of the patients have required further surgery and are continue to do well clinically at latest follow up. Conclusions. In the short term, this study confirms revision ankle replacements with the Invision prosthesis and impaction with morselized femoral head allograft is a suitable revision option for primary ankle replacement failure with massive talar bone loss. Long term follow up continues of these complex patients


Bone & Joint 360
Vol. 13, Issue 3 | Pages 35 - 36
3 Jun 2024

The June 2024 Spine Roundup360 looks at: Intraoperative navigation increases the projected lifetime cancer risk in patients undergoing surgery for adolescent idiopathic scoliosis; Intrawound vancomycin powder reduces delayed deep surgical site infections following posterior spinal fusion for adolescent idiopathic scoliosis; Characterizing negative online reviews of spine surgeons; Proximal junctional failure after surgical instrumentation in adult spinal deformity: biomechanical assessment of proximal instrumentation stiffness; Nutritional supplementation and wound healing: a randomized controlled trial.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 16 - 16
10 May 2024
Bartle D Wesley J Bartlett J
Full Access

INTRODUCTION. Simulation plays an important role in surgical education and the ability to perfect surgical performance. Simulation can be enhanced by adding various layers of realism to the experience. Haptic feedback enhances the simulation experience by providing tactile responses and virtual reality imagery provides an immersive experience and allows for greater appreciation of three-dimensional structures. In this study, we present a proof-of-concept haptic simulator to replicate key steps of a cervical laminoplasty procedure. The technology uses affordable components and is easily modifiable so that it can be used from novice through to expert level. Custom models can be easily added ensuring the simulator can be used in a wide range of orthopaedic applications from baseline education through to day of surgery pre-operative simulation. METHOD. We used the Unity Game Engine, the 3D Systems “Touch” Haptic Feedback Device (HFD), and a Meta Quest VR headset. Our system uses a number of complex algorithms to track the shape and provide haptic feedback of a virtual bone model. This allows for simulation of various tools including a high-speed burr, Kerrison rongeur and intraoperative X-rays. RESULTS. Our simulator replicates the tactile sensations of bone-burring tasks. Although we focused on the cervical laminoplasty procedure, the system can load data from CT scans, enabling the simulation of multiple other procedures. The parts cost of our system, $10,000 NZD, is a fraction of the cost of traditional surgical simulators. DISCUSSION. Our simulator reduces financial barriers to accessing orthopaedic simulators. Trainees can perform hands-on practice without compromising patient safety. The immersive nature of VR, combined with realistic haptic feedback, enables trainees to develop the dexterity and three-dimensional understanding of detailed bony work. Further refinements are needed before we can perform validation studies on our system. CONCLUSIONS. We present an affordable surgical simulator capable of simulating bony surgical procedures in a VR environment using haptic feedback technology and consumer-grade components. ACKNOWLEDGEMENTS. This research was made possible by the generosity of the Wishbone Trust


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 10 - 10
8 May 2024
Nanavati N Davies M Blundell C Flowers M Chadwick C Davies H
Full Access

Introduction. The current treatment for Freiberg's osteochondrosis centres around either: simple debridement or debridement osteotomy. The main principle of the osteotomy is to rotate normal articular cartilage into the affected area. We recommend the use of CT scanning to delineate the amount of available, unaffected cartilage available to rotate into the affected space. Methods. We retrospectively reviewed 32 CT scans of new Freiberg's diagnoses in Sheffield over a 10 year period using the PACS system. We identified the sagittal CT slice that displayed the widest portion of proximal articular margin of the proximal phalanx and measured the diseased segment of the corresponding metatarsal head as an arc (in degrees). This arc segment was divided by 360°. This gave a ratio of the affected arc in the sagittal plane. Results. 28 out of 32 cases involved the 2nd metatarsal with the remaining 4 involving the 3rd metatarsal head. Of 32 cases, 18 had fragmentation. Surgically, 20 had debridement only, 5 also had an osteotomy and 1 had a fusion. 6 of the 32 cases were managed non-operatively. 11 cases out of 32 had an arc ratio of < 0.3. Of these, only 3 had an osteotomy, 3 had no procedure and 5 had a simple debridement. Of those that had osteotomies (5/32), 3 of the 5 cases had an arc ratio of < 0.3 with the other 2 being 0.42 and 0.38. Discussion. We hypothesise that those cases with an arc ratio of less 0.3 would be amenable to a dorsal closing wedge osteotomy and those with a ratio of more than 0.4 would be better suited to a simple debridement. For those cases between 0.3–0.4, we feel either option is viable. Further work to prove or disprove outcomes related to our classification is required


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 15 - 15
8 May 2024
Coetzee C Myerson M Anderson J McGaver RS
Full Access

Introduction. AlloStem/Cellular Bone Allograft and autologous bone graft are accepted methods for managing hindfoot degenerative arthritis. The purpose was to evaluate outcomes of AlloStem and autograft in subtalar arthrodesis and compare overall fusion rates. Methods. This study was conducted in IRB compliance. Patients between 18–80 years who qualified for a subtalar fusion were randomized 1:1 to AlloStem or autologous graft. The AOFAS hindfoot ankle scale, FFI-R and SF-12 were collected pre-operatively, 6 weeks, 3 & 6 months, 1 and 2 year. Weight-bearing 3-view ankle X-rays were done at the same intervals. A CT scan was obtained at 6 months. Results. 140 patients were enrolled; 124 patients had surgery(60-AlloStem and 64-Control). Withdrawals included 14 voluntarily before surgery and 2 intra-operative failures. 19 were lost to follow-up. Mean age for AlloStem was 56.69(20.3–79.6) and Autograft was 54.60(20.74–80.07). 59 AlloStem patients completed their 6 month visit and 45 completed 2 years. AOFAS score improved: 40.02 at pre-op to 72.16(6 mo) to 79.51 at 1 year and 80.38 at 2 year. SF-12 improved 58.29 at pre-op to 65.67 at 6 month and 71.59 at 2 year. FFI-R improved 236.88 at pre-op to 203.53 at 6 month 149.93 at 2 year.60 Autograft patients completed their 6 month visit and 51 patients completed their 2 year. AOFAS score improved 42.89 at pre-op to 75.67 (6 mo) to 79.75 at 1 year and 78.62 at 2 year. Autograft SF-12 improved 60.55 at pre-op to 70.40 at 6 month and 75.26 at 2 year. Autograft FFI-R improved 217.16 at pre-op to 166.77 at 6 month and 145.43 at 2 year. AlloStem patients had a mean posterior fusion rate of 28.9% at 6 months whereas the Autograft had 46.3%(p=.049). Non-union rates were AlloStem(9/57)(15.7%) whereas Autograft was 3/60(5%). Conclusion. AlloStem trended to be inferior to Autologous graft


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 1 - 1
2 May 2024
Mayne A Saad A Botchu R Politis A Wall P McBryde C
Full Access

Radiological investigations are essential in the work-up of patients presenting with non-arthritic hip pain, to allow close review of the complex anatomy around the hip and proximal femur. The aim of this study is to quantify the radiation exposure associated with common radiological investigations performed in assessing young adult patients presenting with non-arthritic hip pain. A retrospective review of our UK tertiary hip preservation centre institutional imaging database was performed. Data was obtained for antero-posterior, cross-table lateral and frog-lateral radiographs, along with data for the low dose CT hip protocol and the Mako CT Hip protocol. The radiation dose of each imaging technique was measured in terms of dose-area product (DAP) with units of mGycm2, and the effective doses (ED, mSv) calculated. The mean effective radiation dose for hip radiographs was in the range 0.03 to 0.83mSv (mean DLP 126.7–156.2 mGycm2). The mean effective dose associated with the low-dose CT hip protocol was 3.04mSv (416.8 mGycm2) and for the Stryker Mako CT Hip protocol was 8.4mSv (1061 mGycm2). The radiation dose associated with use of CT imaging was significantly greater than plain radiographs (p<0.005). Investigation of non-arthritic hip pain can lead to significant ionising radiation exposure for patients. In our institution, the routine protocol is to obtain an anteroposterior radiograph and then a specific hip sequence 3 Tesla MRI including anteversion views. This provides the necessary information in the majority of cases, with CT scanning reserved for more complex cases where we feel there is a specific indication. We would encourage the hip preservation community to carefully consider and review the use of ionising radiation investigations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 21 - 21
2 May 2024
Palit A Kiraci E Seemala V Gupta V Williams M King R
Full Access

Ideally the hip arthroplasty should not be subject to bony or prosthetic impingement, in order to minimise complications and optimise outcomes. Modern 3d planning permits pre-operative simulation of the movements of the planned hip arthroplasty to check for such impingement. For this to be meaningful, however, it is necessary to know the range of movement (ROM) that should be simulated. Arbitrary “normal” values for hip ROM are of limited value in such simulations: it is well known that hip ROM is individualised for each patient. We have therefore developed a method to determine this individualised ROM using CT scans. CT scans were performed on 14 cadaveric hips, and the images were segmented to create 3d virtual models. Using Matlab software, each virtual hip was moved in all potential directions to the point of bony impingement, thus defining an individualised impingement-free 3d ROM envelope. This was then compared with the actual ROM as directly measured from each cadaver using a high-resolution motion capture system. For each hip, the ROM envelope free of bony impingement could be described from the CT and represented as a 3d shape. As expected, the directly measured ROM from the cadaver study for each hip was smaller than the CT-based prediction, owing to the presence of constraining soft tissues. However, for movements associated with hip dislocation (such as flexion with internal rotation), the cadaver measurements matched the CT prediction, to within 10°. It is possible to determine an individual's range of clinically important hip movements from a CT scan. This method could therefore be used to create truly personalised movement simulation as part of pre-operative 3d surgical planning