Excellent results with use of tapered wedged cementless stem have been reported. The purpose of this study was to clarify the indication of tapered wedged cementless stems for patients with poor bone quality. Sixty-five hemiarthroplasties in 79 patients with diagnosis of femoral neck fracture were performed between February 2004 and August 2011. 14 patients were lost to follow-up after surgery, and it is 19 patients among the leaving 65 patients had the stovepipe canal. There were 2 men and 16 women, with a mean age at time of surgery 85 years (range, 75–92 years). All components were tapered wedged cementless stem (LINEAR: Encore, Kinectiv: ZIMMER). Evaluation of patient followed includes radiographic analysis (canal flare index, canal fill rate, stem alignment, bone reaction, and stem stability) and recording complication.Background
Method
Mean age of 120 patients (98 women and 22 men) was 45 y.o. (range: 32–61 y.o.). Follow-up time in study group was from 6 to 12 months (mean: 8,5 months). Follow-up time in control group was from 10 to 16 months (mean: 10,5 months). Mean preoperative functional status of the study group was 44,5p in Harris hip score. Radiographic evaluation of the results was made according to criteria of Joined Committee of The Hip Society, AAOS and SICOT.
Total hip arthroplasty has been constantly evolving with technological improvements to achieve the best survival rates. Although the new implants are under closer surveillance through processes such as Beyond Compliance, orthopaedic surgeons generally tend to look out for the latest implants with good
Introduction. Many minimally-invasive approaches have been described in an effort to improve
Short-stem total hip arthroplasty (THA) has primarily been recommended for young and active patients, mainly due to its bone preserving philosophy. Elderly patients, however, may also benefit of a minimally invasive technique due to the short and curved implant design. The purpose of this study was to compare the clinical and radiological outcomes as well as perioperative complications of a calcar-guided short stem between a young (75 years) population. Data were collected in a total of 5 centers, and 400 short stems were included as part of a prospective multicentre observational study between 2010 and 2014 with a mean follow-up of 49.2 months. Clinical and radiological outcomes were assessed in both groups. Secondary outcomes such as perioperative complications, rates and reasons for stem revision were also investigated. No differences were found for the mean visual analogue scale (VAS) values of rest pain, load pain, and satisfaction. Harris Hip Score (HHS) was found to be slightly better in the young group. Comparing both groups, no statistically significant differences ere found in the radiological parameters that were assessed (stress-shielding, cortical hypertrophy, radiolucency, osteolysis). Aseptic loosening was the main cause of implant failure in younger patients whereas in elderly patients, postoperative periprosthetic fractures due to accidental fall was found to be the main cause for stem revision. These
With the increase in the elderly population, there is a dramatic increase in the number of spinal fusions. Spinal fusion is usually performed in cases of primary instability. However it is also performed to prevent iatrogenic instability created during surgical treatment of spinal stenosis in most cases. In literature, up to 75% of adjacent segment disease (ASD) can be seen according to the follow-up time. 1. Although ASD manifests itself with pathologies such as instability, foraminal stenosis, disc herniation or central stenosis. 1,2. There are several reports in the literature regarding lumbar percutaneous transforaminal endoscopic interventions for lumbar foraminal stenosis or disc herniations. However, to the best our knowledge, there is no report about the treatment of central stenosis in ASD. In this study, we aimed to investigate the
Introduction. Total knee arthroplasty (TKA) is an effective surgical intervention, which alleviates pain and improves function and health-related quality of life in patients with end-stage arthritis of the knee joint. With improvements in anesthesia, general health care, and surgical techniques, this procedure has become widely accepted for use in very elderly patients. However, many elderly patients tend to have compromised function and low reserve capabilities of organs and are therefore likely to develop various complications during the perioperative period. Thus, elderly patients often hesitate to undergo simultaneous bilateral TKA (SBTKA). Our purpose was to report the
Introduction. Osteotomy for medial gonarthrosis is most often done as a proximal tibial valgus osteotomy, either as a closing wedge osteotomy (HTO) or as an opening wedge osteotomy including hemicallostasis (HCO). In case of lateral gonarthrosis the osteotomy is done as a proximal tibial varus osteotomy, closing or opening wedge or as a distal femoral varus osteotomy depending on the anatomy of the knee. The early period after osteotomy is influenced by complications to osteotomy. Complications depend on the operative method and localisation of surgery. Short- and long-term results are presented as knee scores or survivorship of high tibial osteotomy. Most often used scores are the HSS-score, NHP-score and the knee scores according to Lysholm and Tegner. Scores from the patient’s perspective are NHP, SF-36. KOOS (Knee Injury and Osteoarthritis Outcome Score) was introduced recently, and only
Introduction. Ankle arthrodesis is a common treatment for destroyed ankle arthrosis with sacrificing the range of motion. On the other hand, total ankle arthroplasty (TAA) is an operation that should develop as a method keeping or improving range of motion (ROM); however, loosening and sinking of the implant have been reported in especially constrained designs of the implant. The concept of FINE TAA is the mobile bearing system (Nakashima Medical Co., Ltd, Okayama Japan) that can reduce stress concentration to implants. The purpose of this study is to evaluate the
Introduction. Acetabular revision surgery is challenging due to severe bone defects. Burch-Schneider anti-protrusion cages (BS cage: Zimmer-Biomet) is one of the options for acetabular revision, however higher dislocation rate was reported. A computed tomography (CT)-based navigation system indicates us the planned direction for implantation of a cemented acetabular cup during surgery. A large diameter femoral head is also expected to reduce the dislocation rate. The purpose of this study is to investigate
Introduction. In our institution, we started to perform THA with SuperPATH approach, including preservation of soft tissue around the hip (James Chow et al. Musculoskelet Med 2011) since July 2014, aiming for fast recovery and prevention of hip dislocation. For minimally-invasive approaches, however, there have been a few reports on malalignment of the implants related to shortage of operative field. The purpose of this study is to examine the
Purpose. There is a large gap between UKA and TKA in terms of tissue preservation including bone stock and knee ligament. We have recently introduced bicompartmental UKA (Bi-UKA) to fill the gap and achieve more “physiological” knee than TKA. In this study, we report the
Total hip arthroplasty has become one of the most successful orthopaedic procedures with long-term survival rate. An ever-increasing acceptance of the potential longevity of THA systems has contributed to an increasing incidence of THA in younger and more active patients. Nowadays, especially in younger patients, cementless THA is the favored method worldwide. Since the first cementless THA in late 1970s, many implant designs and modifications have been made. Despite excellent long-term results for traditional straight cementless stems, periprosthetic fractures or gluteal insufficiency are still a concern. For instance, as reported in a meta-analysis by Masonis and Bourne, the incidence of gluteal insufficiency after THA varies between 4% and 22%. In contrast, the flattened lateral profile of the SP-CL. ®. anatomical cementless stem can protect the greater trochanter during the use of cancellous bone compressors and can avoid gluteal insufficiency after THA. Another benefit of this stem design is the rotational stability and the natural load transfer due to the anatomical concept. In this context, we report our experiences using the SP-CL. ®. anatomical cementless stem. The study group consists of 1452 THA cases (850 male, 602 female) with an average age of 62 years (range 25–76 years). After a mean follow-up of 20 months, in seven cases (0.5%) a stem exchange was necessitated. The reason for stem revision was periprosthetic fracture in 4 cases (0.3%) and periprosthetic joint infection in three cases (0.2%). In five patients, hip dislocation and in four patients migration of the stem occurred. However, stem exchange was not required in those cases. In conclusion, the SP-CL. ®. anatomical cementless stem has excellent
Introduction. MERA Quest Knee System (Quest Knee) is a posterior cruciate ligament–retaining prosthesis considering the anatomical features and lifestyles of the Japanese. As for the anatomical features, we reduced the size of prosthesis and set a smaller interval of sizes because Japanese knees are smaller and flatter than those of Caucasians. As for the lifestyles, we evaluated in vivo patellar tracking during deep knee flexion and the condylar geometry in the axial plane of magnetic resonance imaging. It was found that the patella sank deeply into the intercondylar notch and that the articular surface of the lateral condyle began to curve steeply. We adopted this shape and engraved the lateral condyle deep to reduce the pressure of the patellofemoral joint and to get better range of motion (ROM). For the contact pressure rise in the femorotibial joint by engraving the lateral condyle, the insert was suited to the shape of the femoral component. Furthermore, we increased the thickness of the posterior flange of the femoral component and changed the posterior radius of curvature gradually, and this shape allowed the flexion of 155°. We have used Quest Knee for clinical applications from October 2009. We studied the
Introduction. Osteochondral defects of the knee may occur following patella dislocation or following direct trauma or twisting injuries to the knee in adolescents. Often a diagnostic and therapeutic challenge, if these lesions are left, posttraumatic osteoarthritis may occur. This retrospective single centre study presents the
Reconstruction of massive acetabular bone defects in primary and revision THA is challenging for reconstructive joint surgeons. The use of porous metal augments is one of the options. The advantages of porous metal augments are easy to use, modularity and lack of resorption. We investigated the radiological results of porous metal augments used for massive acetabular bone defects in primary and revision THA. Forty-one hips in forty patients had porous metal augments between 2011 and 2016. Thirty of the procedures were revision arthroplasties and 11 were primary procedures (Crowe type III in 5 hips, Crowe type IV in 3, septic hip sequalae in 2 and RA in one). Four of the revisions were second-stage reimplantation after infection. The Paprosky classification for revision was 2B in 4 hips, 2C in one, 3A in 3 and 3B in 22. Regenerex augments were used in 39 hips and trabecular metal augments were used in 2. Thirty-six cups were cemented and 5 cups were uncemented. Mean follow-up was 37.6 months (range, 1–82). Radiographic findings of osteointegration between host bone and the porous metal augments were assessed. The presence or absence of radiolucent lines between cement or cup/host bone and augment/host bone interface was noted. Two revisions were performed due to infection, one month and 66 months after operation. The other implants were stable without any complications. Osteointegration between host bone and the porous metal augments were recognized in 36 hips. Radiolucent lines between cement/host bone interface, less than 1 mm in width, were visualized in 2 hips. Porous metal augments are convenient and our
The advent of modern anatomic shoulder arthroplasty occurred in the 1990's with the revelation that the humeral head dimensions had a fixed ratio between the head diameter and height. As surgeons moved from the concept of balancing soft tissue tension by using variable neck lengths for a given humeral head diameter, a flawed concept based on lower extremity reconstruction, improvements in range of motion and function were immediately observed. Long term outcome has validated this guiding principle for anatomic shoulder replacement with improved longevity of implants, improved patient and surgeon expectations and satisfaction with results. Once the ideal humeral head prosthesis is identified, and its position prepared, the surgeon must use a method to fix the position of the head that is correct in three dimensions and has the security to withstand patient activities and provide maximal longevity. Based again on lower extremity concepts, long stems were the standard of care, initially with cement, and now, almost universally without cement for a primary shoulder replacement. The incredibly low revision rates for humeral stem aseptic loosening shifted much of the attempted innovation to the challenges on the glenoid side of the reconstruction. However, glenoid problems including revision surgery, infections, periprosthetic fractures, and other complications often required the removal of the humeral stem. And, in many cases, the overall results of the procedure and the patient's long-term outcome was affected by the difficulty in removing the stem, leading surgeons to compromise the revision procedure, avoid revision surgery, or add to the overall morbidity with humeral fractures and substantial bone loss. With improved technology, including bone ingrowth methods, better matching of the proximal stem geometry to the humerus, and an understanding that the center of rotation (torque) on the humeral component is at the level of the humeral osteotomy, shorter stems and stemless humeral components were developed, now more than 10 years ago, primarily in Europe. With more than a decade of experience, our European colleagues have shown us that stemless humeral component replacement with a device that has both cortical and cancellous fixation is as effective as a stemmed device, easier to implant as well as revise when needed. The
Advances in implant design and instrumentation have led to total ankle replacement (TAR) becoming an attractive alternative to ankle fusion in selected cases. We present the
Isolated patellofemoral arthritis is not an uncommon problem, with no clear consensus on treatment. Nonoperative and many forms of operative treatments have failed to demonstrate long-term effectiveness in the setting of advanced arthritis. Total knee arthroplasty (TKA) has produced excellent results, but many surgeons are hesitant to perform TKA in younger patients with isolated patellofemoral arthritis. In properly selected patients, patellofemoral arthroplasty (PFA) is an effective procedure with good long-term results. Contemporary PFA prostheses have eliminated many of the patellar maltracking problems associated with older designs, and
Compromised patellar bone stock poses significant the chnical problems in primary and revision knee arthroplasty. In these situations, traditional approaches have included: non resurfacing, patellectomy, patellar bone grafting, ‘Gull-Wing’ osteotomy. A new material (Trabecular Metal) fabricated using a tantalum metal and vapor deposition techhnique that create a metallic strut configuration with 80%porosity, and physical and mechanical properties similar to bone has been introduced. The authors studied the