Advertisement for orthosearch.org.uk
Results 1 - 20 of 26
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 41 - 41
1 Oct 2020
Pandit HG Blyth M Maheshwari R McDonnell S Frappin G Hagen M Maybaum N Moreira S Seefried L
Full Access

Introduction. Topical diclofenac has proven efficacy and safety in the management of osteoarthritic pain. Its therapeutic efficacy is dependent on its ability to deliver pharmacodynamically active concentrations to the underlying tissues in the affected joint. However, the disposition of topical diclofenac is not fully characterized, and no studies have been performed using diclofenac diethylamine 2.32% gel. Methods. This study investigated the penetration of topical diclofenac into knee synovial tissue and fluid and evaluated relative exposure in the knee versus plasma. In this phase 1, double-blind, placebo-controlled steady-state multicenter pharmacokinetic study, patients scheduled for arthroplasty to treat knee OA were randomly assigned 2:1 to 4 g diclofenac/placebo gel, applied to the affected knee every 12 hours for 7 days pre-surgery. Diclofenac concentrations were measured in synovial tissue, fluid, and plasma ≥12 hours after last application. Adverse events (AEs) were evaluated. Diclofenac concentrations were assayed by validated high-performance liquid chromatography and tandem mass spectrometry. Results. Samples were obtained from 45 (diclofenac n=29; placebo n=16) of 47 patients enrolled. Mean (SD) age was 71.2 (7.9) years with 52.2% women and mean (SD) BMI 30.7 (4.8) kg/m. 2. All diclofenac-treated participants had measurable diclofenac concentrations in synovial tissue (mean [95% CI]) 1.57 [1.12, 2.20] ng/g) and fluid 2.27 [1.87, 2.76] ng/mL ≥12 hours after the last dose. The mean (95% CI) ratio of diclofenac in synovial tissue:plasma was 0.32 (0.23, 0.45) and in synovial fluid:plasma was 0.46 (0.34, 0.54). AEs were similar for diclofenac (55.2%) and placebo (58.8%); none were treatment related. No correlation (r=−0.003) between BMI and synovial fluid concentration, and weak positive correlation (r=0.315) between BMI and synovial tissue concentration were observed. Conclusions. Topical diclofenac diethylamine 2.32% gel penetrated the knee and remained detectable at the end of the final 12-hour dosing cycle. BMI had no impact on diclofenac's penetration into the knee


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 91 - 91
1 Dec 2020
Hanberg P Bue M Öbrink-Hansen K Thomassen M S⊘balle K Stilling M
Full Access

Tourniquet is widely used in extremity surgery. In order to prevent surgical site infection, correct timing of antimicrobial prophylaxis and tourniquet inflation is important. We aimed to evaluate the time for which the free drug concentration of cefuroxime is maintained above the minimal inhibitory concentration (T>MIC) in subcutaneous tissue and calcaneal cancellous bone during three clinically relevant tourniquet application scenarios.

Twenty-four female pigs were included. Microdialysis catheters were placed for sampling of cefuroxime concentrations bilaterally in calcaneal cancellous bone and subcutaneous tissue, and a tourniquet cuff was applied on a randomly picked leg of each pig. Subsequently, the pigs were randomized into three groups to receive 1.5 g of cefuroxime by intravenous injection 15 min prior to tourniquet inflation (Group A), 45 min prior to tourniquet inflation (Group B), and at the tourniquet release (Group C). The tourniquet duration was 90 min in all groups. Dialysates and venous blood samples were collected eight-hours postcefuroxime administration.

Cefuroxime concentrations were maintained above the clinical breakpoint MIC for Staphylococcus aureus (4 μg/mL) in calcaneal cancellous bone and subcutaneous tissue throughout the 90 min tourniquet duration in Group A and B. Cefuroxime administration at tourniquet release (Group C) resulted in concentrations above 4 μg/mL for a minimum of 3.5 hours in the tissues on the tourniquet side. There were no significant differences in the T>MIC (4 μg/mL) in subcutaneous tissue or calcaneal cancellous bone between the three groups. However, Group A tended toward shorter T>MIC in tourniquet calcaneal cancellous bone compared to Group C (p=0.08).

We conclude that administration of cefuroxime (1.5 g) in the 15–45 min window prior to tourniquet inflation resulted in sufficient calcaneal cancellous bone and subcutaneous tissue concentrations throughout the 90 min tourniquet application. If the target is to maintain postoperative cefuroxime concentrations above relevant MIC values, our results suggest that a second dose of cefuroxime should be administered at tourniquet release.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 92 - 92
1 Dec 2020
Hanberg P Bue M Kabel J J⊘rgensen AR Jessen C S⊘balle K Stilling M
Full Access

Tourniquet is widely used in orthopedic surgery to reduce intraoperative bleeding and improve visualization. We evaluated the effect of tourniquet application on both peri- and postoperative cefuroxime concentrations in subcutaneous tissue, skeletal muscle, calcaneal cancellous bone, and plasma. The primary endpoint was the time for which the free drug concentration of cefuroxime was maintained above the clinical breakpoint minimal inhibitory concentration (T>MIC) forStaphylococcus aureus (4 µg/mL).

Ten patients scheduled for hallux valgus or hallux rigidus surgery were included. Microdialysis catheters were placed for sampling of cefuroxime concentrations bilaterally in subcutaneous tissue, skeletal muscle, and calcaneal cancellous bone. A tourniquet was applied on the thigh of the leg scheduled for surgery. Cefuroxime (1.5 g) was administered intravenously as a bolus 15 minutes prior to tourniquet inflation, followed by a second dose 6 hours later. The mean tourniquet duration (range) was 65 (58; 77) minutes. Dialysates and venous blood samples were collected for 12 hours.

For cefuroxime the T>MIC (4 μg/mL) ranged between 4.8–5.4 hours across compartments, with similar results for the tourniquet and non-tourniquet leg. Comparable T>MIC and penetration ratios were found for the first and second dosing intervals.

We concluded that administration of cefuroxime (1.5 g) 15 minutes prior to tourniquet inflation is safe in order to achieve tissue concentrations above 4 µg/mL throughout surgery. A tourniquet application time of approximately 1 hour did not affect the cefuroxime tissue penetration in the following dosing interval.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 48 - 48
1 Oct 2022
Bos K v. Dorp A Koch BC Ringeling L Veltman ES v. Oldenrijk J
Full Access

Aim. The current antibiotic treatment of periprosthetic joint infection (PJI) is optimized by measuring concentrations in plasma. However, it remains unclear whether effective concentrations of the antibiotics are reached at the site of PJI. Nonetheless, adequate target site concentrations are important to achieve effective eradication of the micro-organism. In order to determine the efficacy of cefuroxime and flucloxacillin in synovial fluid, synovial tissue and bone tissue in relation to the minimal inhibitory concentration (MIC) of the pathogen causing the PJI, we perform a pharmacokinetic/pharmacodynamic (PK/PD) study. Therefore, we aimed to develop validated analytical methods for analysis of cefuroxime and flucloxacillin in synovial fluid, synovial tissue and bone tissue. Method. Blank samples of synovial fluid, synovial tissue and bone tissue were obtained by orthopedic surgeons during surgery. For validation the samples of each matrix were spiked with both cefuroxime and flucloxacillin. Synovial tissue and bone tissue was pulverized with a mikro-dismembrator. Samples were kept frozen at −20°C until analysis. After a sample preparation quantification of cefuroxime and flucloxacillin in each matrix was performed on the ultra-performance convergence chromatography-tandem mass spectrometry (UPC2-MS/MS). Stable-isotope-labeled meropenem-d6 served as internal standard. The linearity, limits of quantification, accuracy and precision and carry-over were determined for all methods separately. The methods were validated according to the European Medicine Agency (EMA) and Food and Drug Administration (FDA) guidelines on bioanalytical method validation. Results. These methods were successfully validated for cefuroxime and flucloxacillin quantification in all matrices according to the EMA and FDA guidelines. The limits of quantification were adequate to cover potential cefuroxime and flucloxacillin concentration in synovial fluid, synovial tissue and bone tissue as described in literature, with a range of 1–100mg/L for synovial fluid and 1–20 µg/g for synovial tissue and bone tissue (r >0.995). Accuracy and within-run precision were validated according to acceptance values (RSD <15%). Carry over was less than 20%. Matrix effects and recovery were investigated for synovial fluid. The results were within the range of 80–120%. Conclusions. The results of the validation fall within the limits of quantification according to the EMA and FDA guidelines. Therefore, these methods can be applied during a PK/PD study to discover the exposure of antibiotics in synovial fluid, synovial tissue and bone tissue at the site of infection in patients with a PJI


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 80 - 80
24 Nov 2023
Rojas-Sayol R Pardos SL No LR Perez CB Redó MLS Pérez-Prieto D
Full Access

Aim. The use of bone substitutes such as calcium sulfate (CaSO4) and hydroxyapatite with local antibiotics are crucial in the treatment of osteomyelitis. They allow the treatment of the dead space and locally provide large concentrations of antibiotics. However, it is unknown whether use of local vancomycin may elute and influence on vancomycin plasma levels. The aim of this study is to assess whether the addition of vancomycin to CaSO4 with hydroxyapatite may increase vancomycin plasma concentrations in in patients with osteomyelitis and therefore alter dosage adjustments. Method. The present study investigates the vancomycin plasma concentrations at 72–94 h post-surgery after the application of local vancomycin within CaSO4 (660mg vancomycin/10cc) and hydroxyapatite bone substitute in patients treated with empiric intravenous vancomycin and surgically treated for osteomyelitis. Vancomycin plasma concentrations were analyzed in twelve patients with osteomyelitis surgically treated with local release of vancomycin by CaSO4 and hydroxyapatite and undergoing therapeutic drug monitoring (TDM) of their vancomycin plasma concentrations as it is routinely done in our hospital. From 2019 to 2022, demographic data, microbiology, type of osteomyelitis, amount of local vancomycin applied, alteration of renal function, and vancomycin levels were retrospectively analyzed. Results. Twelve patients were included: 9(75%) were men. Median (range) demographic and clinical data: age: 51(26–67) years; body mass index: 27.7(18–46.4) kg/m2;baseline serum creatinine: 0.85 (0.7–1.24)mg/dl and 5(41.7%) with and glomerular filtration rate < 90ml/min(CPD-EPI, ml/min). Most frequently isolated microorganisms were Staphylococci (58%). Seven (54%) patients were classified as Cierny-Mader Osteomyelitis type III, 3(23%) as type IV and 2(23%) as type I. Treatment data: initial dose of vancomycin: 1g/8h in 9(75.0%) and 1g/12h in 3(25%) patients, total daily dose/body weight: 35.3(15.9–46.2) mg/kg. Pharmacokinetic data:days of iv vancomycin treatment until first TDM measurement: 3(3–4) days; minimum and maximum vancomycin plasma concentrations: 9.4(3–17.3) mg/L and 19.6(11.3–33.4) mg/L, respectively; patients with therapeutic concentrations: 6(50%); infratherapeutic: 4(33.3%) and supratherapeutic/potentially toxic: 2(16.7%). These 2 patients were young, had a baseline conserved renal function and were receiving the higher dose of 1g/8h. Conclusions. Vancomycin incorporated into the bone substitute appears not to increase blood concentrations of the glycopeptide in patients with osteomyelitis treated surgically and with intravenous vancomycin. However, 2 of the 12 patients presented supratherapeutic and potentially nephrotoxic vancomycin concentrations in the first TDM measurement, even though they were young and without renal impairment and needed and unexpected dose reduction. These results suggest the need to confirm the safety of local vancomycin in further larger clinical studies


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 81 - 81
1 Oct 2022
Hvistendahl MA Bue M Hanberg P Kaspersen AE Schmedes AV Stilling M Høy K
Full Access

Background. Surgical site infection following spine surgery is associated with increased morbidity, mortality and increased cost for the health care system. The reported pooled incidence is 3%. Perioperative antibiotic prophylaxis is a key factor in lowering the risk of acquiring an infection. Previous studies have assessed perioperative cefuroxime concentrations in the anterior column of the cervical spine with an anterior surgical approach. However, the majority of surgeries are performed in the posterior column and often involve the lumbar spine. Accordingly, the objective was to compare the perioperative tissue concentrations of cefuroxime in the anterior and posterior column of the same lumbar vertebra using microdialysis in an experimental porcine model. Method. The lumbar vertebral column was exposed in 8 female pigs. Microdialysis catheters were placed for sampling in the anterior column (vertebral body) and posterior column (posterior arch) within the same vertebra (L5). Cefuroxime (1.5 g) was administered intravenously over 10 min. Microdialysates and plasma samples were continuously obtained over 8 hours. Cefuroxime concentrations were quantified by Ultra High Performance Liquid Chromatography Tandem Mass Spectrometry. Microdialysis is a catheter-based pharmacokinetic tool, that allows dynamic sampling of unbound and pharmacologic active fraction of drugs e.g., cefuroxime. The primary endpoint was the time with cefuroxime above the clinical breakpoint minimal inhibitory concentration (T>MIC) for Staphylococcus aureus of 4 µg/mL as this has been suggested as the best predictor of efficacy for cefuroxime. The secondary endpoint was tissue penetration (AUC. tissue. /AUC. plasma. ). Results. Mean T>MIC 4 µg/mL (95% confidence interval) was 123 min (105–141) in plasma, 97 min (79–115) in the anterior column and 93 min (75–111) in the posterior column. Tissue penetration (95% confidence interval) was incomplete for both the anterior column 0.48 (0.40–0.56) and posterior column 0.40 (0.33–0.48). Conclusions. Open lumbar spine surgery often involves extensive soft tissue dissection, stripping and retraction of the paraspinal muscles which may impair the local blood flow exposing the lumbar vertebra to postoperative infections. A single intravenous administration of 1.5 g cefuroxime resulted in comparable T>MIC between the anterior and posterior column of the lumbar spine. Mean cefuroxime concentrations decreased below the clinical breakpoint MIC for S. aureus of 4 µg/mL after 123 min (plasma), 97 min (anterior column) and 93 min (posterior column). This is shorter than the duration of most lumbar spine surgeries, and therefore alternative dosing regimens should be considered in posterior open lumbar spine surgeries lasting more than 1.5 hours


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 30 - 30
1 Oct 2022
Jensen LK Jensen HE Blirup SA Bue M Hanberg P Soto S Aalbaek B Arkas M Vardavoulias M
Full Access

Aim. To develop a new system for antibacterial coating of joint prosthesis and osteosynthesis material. The new coating system was designed to release gentamicin immediately after insertion to eradicate surgical contamination. Method. Steel implants (2×15mm) were coated with a solid nanocomposite xerogel made from silica and the dendritic polymer, hyperbranched polyethyleneimine. The xerogel was anchored inside a porous surface made by pre-coating with titanium microspheres. Finally, gentamicin was encapsulated in the xerogel, i.e. no chemical binding. A total of 50 µg gentamicin was captured into each implant. The efficacy of the new coating was evaluated in a porcine model of implant associated osteomyelitis. In total, 30 female pigs were randomized into 3 study groups (n=10). Group A; plain implants + saline, Group B; plain implants + 10. 4. CFU of Staphylococcus aureus, and Group C; coated implants + 10. 4. CFU of S. aureus. Implant + inoculum was placed into a pre-drilled implant cavity of the right tibia and the pig was euthanized 5 days afterwards. Postmortem microbiology and pathology were performed. Two additional pigs were used in a pharmacokinetic study where microdialysis (MD) catheters were placed alongside coated implants. Extracellular fluid was sampled regularly for 24 hours from the MD catheters and analyzed for gentamicin content. Results. Within Groups A and C, all implants were found sterile by sonication and bacteria could not be identified within the surrounding bone tissue. In contrast, all Group B animals had S. aureus positive implant and tissue microbiology. Macroscopic and microscopic pathological examinations confirmed that Group A and C animals were complete identic, i.e. no pus around implants and only minor peri-implant inflammation related to insertion of implants per se. All Group B animals had pus around their implants and a massive peri-implant inflammatory response dominated by neutrophil granulocytes. Maximum gentamicin release (35 µg /mL) was measured in the first obtained MD sample, i.e. after 30 min, and the concentration stayed above the MIC level for the used S. aureus strain for 8 hours. Conclusions. The new xerogel coating prevented development of osteomyelitis. Prevention was due to a fast gentamicin release immediately following insertion and antimicrobial active concentrations were detectable several hours after implantation. This means that the critical time point of most relevant surgical procedures potentially could be protected by the novel coating. The new coating will be investigated on larger scale implants and full-size prosthesis in the future


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 50 - 50
1 Oct 2022
Pardos SL No LR Arderiu A Redó MLS Prieto DP Junyent JG Verdie LP Fabrego AA Prim N Cerrato SG
Full Access

Aim. Vancomycin is frequently used for bone and joint infections (BJI) because of the main role of Gram-positive bacteria as potential causal agents. It is crucial to achieve optimal vancomycin plasma concentrations since the first day to maximize treatment clinical and microbiological efficacy. The aim was to describe the patients’ profile that are more likely to achieve an optimal pharmacokinetic/pharmacodynamics (PK/PD) vancomycin target in the first therapeutic drug monitoring (TDM) sample. Methods. Retrospective study (March 2018-January 2022) in a university hospital including all patients treated with vancomycin for a BJI and undergoing TDM. Initial dose (1g/8-12h) was selected by the responsible clinician. Vancomycin plasma concentrations were obtained pre-dose (Cmin,ss) and 60-minutes after the infusion on day 2 of treatment. Global exposure measured by the area under the curve of plasma concentrations during 24h (AUC024h) was estimated using a bicompartmental PK model. An AUC024h/CMI=400–600mg*h/L was considered optimal, <400 infratherapeutic and >600 supratherapeutic, based on recent guidelines, and patients were classified into these 3 groups. A value of CMI=1 mg/L was considered, following guidelines recommendations. Categorial data: percentages and quantitative data as mean (standard deviation). Results. Ninety-five patients were included: 22(23.2%), 43(45.3%) and 30(31.6%) presented an infratherapeutic, optimal and supratherapeutic PKPD target, respectively. Medium age was 75,8(13,5) in the supratherapeutic group versus 57,2(16,3) in the infratherapeutic group. Weight (kg) was higher in the infratherapeutic group 80,8(18,4) versus 66,8(15,5) in the supratherapeutic group. Vancomycin dose (mg/kg/d) was 43,5(12,4) in the supratherapeutic group versus 34,5(10,8) in the infratherapeutic group. There were 17(56,7) patients who received 1g/8h of vancomycin in the supratherapeutic group and 6 (27,3) in the infratherapeutic group. Baseline glomerular filtration rate (BGF (CKD-EPI) (mL/min/1.73m2) was 71,5(20,1) in the supratherapeutic group and 100,0 (19,9) in the infratherapeutic group. The AUC24h/CMI was 788,0(186,1) in the supratherapeutic group and 323,7(55,4) in the infratherapeutic group. Significant differences observed in age, body weight (BW), baseline renal function and dose/frequency of vancomycin. Dosage adjustments recommendations were made in 62(65.3%) patients: 31(32.6%) dose-increase, 29(30.5%) reduction and 2 cases (2.1%) a temporary suspension. Conclusions. Less than 50% of patients achieved an optimal exposure of vancomycin on day 2 of treatment. Patients with infratherapeutic levels had a younger age and a higher body weight and glomerular filtration rate. In addition, they had received a lower vancomycin initial dose. On the contrary, a potentially toxic exposure was observed within older patients with impaired baseline renal function. These data suggest the relevance of an early vancomycin TDM for optimizing the treatment of BJI


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 44 - 44
1 Dec 2018
Stravinskas M Tarasevicius S Vitkauskiene A Nilsson M Lidgren L
Full Access

Aim. In vivo studies have shown a preventive and curative effect of using an injectable vancomycin containing biphasic ceramic in an osteomyelitis model. No clinical long term pharmacokinetic release study has been reported. Inadequate concentration in target tissues results in treatment failure and selection pressure for antibiotic-resistant organisms. Our hypothesis was that vancomycin in the first week would reach high local concentrations but with low systemic levels. Method. 9 patients (6 women, 3 men) with trochanteric hip fractures classified as A1 and A2 according to the AO-classification all had internal fixations. The mean age was 75.3 years (± S.D. 12.3 years, range 44–84y). An injectable ceramic with hydroxyapatite embedded in a calcium sulphate matrix containing 66mg vancomycin per mL augmented the fixation. A mean of 9.7 mL (± S.D. 0.7 mL, range 8–10mL) was used. The elution of vancomycin was followed by collecting drain fluid, blood (4 days) and urine (4 weeks). Results. The concentration of antibiotics in the drain showed an important burst during the first 12h after surgery, with a mean value of 709.9 µmol/L (± S.D. 383.9), which decreased linearly to a mean value of 60.9 µmol/L at 2.5 days. In the urine, the vancomycin concentration reached 68.9 µmol/L (± S.D. 34.4) during the first day, which was decreased logarithmic over the first two weeks to reach zero at 20 days (see Figure). The systemic concentration of vancomycin was constantly low, not exceeding 2.6 µmol/L. Conclusions. This is the first long term pharmacokinetic study reporting vancomycin release from a biphasic injectable ceramic bone substitute. The study shows initial high targeted local vancomycin levels (wound drainage), sustained and complete release at three weeks (verified by the urine concentrations), and systemic concentrations well below toxic levels. This system should be useful in preventing and treating bone infection


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 79 - 79
1 Sep 2012
Wahl P Livio F Jacobi M Gautier E Buclin T
Full Access

Introduction. Calcium sulphate is a resorbable void filler that can be used for local antibiotic delivery. Results from clinical studies on chronic osteomyelitis thus treated with local vancomycin have already been published. Despite significant exposure to this drug, there are no pharmacokinetic studies published so far. Based on observations in our patients, a model predicting vancomycin serum and wound fluid levels and toxicity potential is presented. Methods. Following implantation of Osteoset® added with vancomycin, serum and wound fluid concentrations of this antibiotic have been monitored systematically. The pharmacokinetic analysis was performed using a non-linear mixed-effects model based on a one-compartment model with first-degree absorption. Results. Data from 43 patients treated between October 2006 and August 2010 were analysed. Serum concentrations remained far below the usually accepted trough levels of 10 mg/L, and were still acceptable in two cases of post-operative renal failure. Wound fluid concentrations around 1,000 mg/l were observed for the first 7–10 days, and remained above usual minimal inhibitory concentrations for approximately a month. Discussion and Conclusion. This is the first pharmacokinetic exploration of calcium sulphate added with vancomycin for local antibiotic therapy. The systemic exposure to vancomycin is low and appears safe even after implantation of up to 6 g vancomycin, except in case of markedly impaired renal function. Wound fluid concentrations of vancomycin appear extremely interesting for further studies


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 62 - 62
1 Dec 2017
Hanberg PE Bue M Sørensen HB Søballe K Tøttrup M
Full Access

Aim. Pyogenic spondylodiscitis is associated with prolonged antimicrobial therapy and high relapse rates. Nevertheless, tissue pharmacokinetic studies of relevant antimicrobials in both prophylactic and therapeutic situations are still sparse. Previous approaches based on bone biopsy and discectomy exhibit important methodological limitations. The objective of this study was therefore to assess the concentration of cefuroxime in intervertebral disc (IVD), vertebral body cancellous bone, subcutaneous adipose tissue (SCT) and plasma pharmacokinetics after single dose administration by use of microdialysis (MD) in a large animal model. Method. Ten female pigs were assigned to receive 1,500 mg of cefuroxime intravenously over 15 min. Measurements of cefuroxime were obtained from plasma, SCT, the vertebral cancellous bone and the IVD for 8 hours thereafter. MD was applied for sampling in solid tissues. The cefuroxime concentration in both the MD and plasma samples was determined using ultra-high performance liquid chromatography. Results. For both the IVD and the vertebral cancellous bone, the area under the concentration-curve from zero to the last measured value was significantly lower than that of free plasma. Tissue penetration of cefuroxime was incomplete for the IVD, whereas for vertebral cancellous bone and SCT it was not. Furthermore, the penetration of cefuroxime from plasma to IVD was delayed. Additionally, a noticeable prolonged elimination rate of cefuroxime in the IVD was found. The maximal concentration and the elimination of cefuroxime were reduced in IVD compared to both SCT and vertebral cancellous bone. Due to this delay in elimination of cefuroxime, the time with concentrations above the minimal inhibitory concentration (T>MIC) was significantly higher in IVD than in SCT, vertebral cancellous bone and free plasma for MICs up to 6 μg/ml. Conclusions. MD was successfully applied for serial assessment of the concentration of cefuroxime in the IVD and the vertebral cancellous bone. Penetration of cefuroxime from plasma to IVD was found to be incomplete and delayed, but due to a prolonged elimination, the best results regarding T>MIC was found in IVD


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 306 - 306
1 May 2009
Swieringa A Jansman F Tulp N
Full Access

Although bovine carriers of antibiotics are generally accepted in the treatment of local infections, a literature search in PubMed, Medline and Embase up to April 2006 did not reveal any information on the human pharmacokinetics on Garacol®, a bovine carrier containing the equivalent of 130 mg gentamicin sulphate, on the market since 1995. The purpose of this study was to describe the human in vivo pharmacokinetics of Garacol®. A cohort of 19 consecutive patients with an acute periprosthetic infection to which 2 to 5 fleeces were applied in each case. Initially, the concentration in blood increased to 3.2–7.2 mg/L depending on the number of fleeces that were applied. The serum peak concentrations resulted in peak/MIC ratios of 2.5–36 for P. aeruginosa, S. aureus and Klebsiella spp. Peak gentamicin levels in the exudate are bactericidal for several days, even for gentamicin-resistant micro-organisms. Subsequently, the serum values decreased almost linearly below 0.3 mg/L in 18 to 62 hours. After 24 hours the gentamicin serum levels dropped below the threshold for toxicity of 2 mg/L. Comparison is made between the difference in pharmacokinetic behaviour of the Garacol® drug with Septocoll® and conventional and mini PMMA beads. The conclusion is that collagen-loaded fleeces may be useful as an adjuvant treatment of implant-related infections


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 46 - 46
1 Apr 2018
Raina DB Isaksson H Tägil M Lidgren L
Full Access

Background. The doses of local rhBMP-2 in commercially available materials are high with known drawbacks such as inflammation and premature bone resorption. The latter can be prevented by adding bisphosphonates like zoledronic acid (ZA) but systemic ZA has side effects and patient adherence to treatment is low. In a recent study, we have shown that local co-delivery of rhBMP-2 and ZA via a calcium sulphate/hydroxyapatite (CS-HA) biomaterial can be used to regenerate both cortical and trabecular bone in a rat model of metaphyseal bone defect. Even low doses of local ZA in the biomaterial showed promising results and increased bone formation within the defect compared to the controls. A step before clinical translation of the local treatment regimen is to evaluate the in-vivo release kinetics of these additives and thus in this study, we aimed to investigate the in-vivo pharmacokinetics of rhBMP-2 and ZA from the CS-HA biomaterial in a rat abdominal muscle pouch model over a period of 4-weeks. Methods. In-vivo release kinetics of 125I labeled rhBMP-2 and 14C labeled ZA was performed using an abdominal muscle pouch model in rats (n=6). Both rhBMP-2 and ZA were labeled commercially with a radiochemical purity of >95%. The detection of 125I -rhBMP-2 release was performed by implanting pellets of the CS-HA biomaterial containing 125I -rhBMP-2 and ZA and the same animals followed over a period of 4-weeks (day 1, 3, 7, 14, 21& 28) using SPECT imaging. Similarly, the 14C-ZA was detected by implanting CS-HA pellets containing rhBMP-2 and 14C-ZA. Release was detected via scintillation counting and at each time point (Day 1, 7, 14& 28) 6-animals were sacrificed. Results. BMP Release. The CS-HA biomaterial retained 95±11% after 3-days, 88±12% after a week, 66±9% after 2 weeks, 51±5% after 3 weeks and 43±7% of 125I labeled rhBMP-2 after 4-weeks in-vivo (SPECT-CT). ZA Release. The CS-HA biomaterial retained 89±14% after a week, 84±8% after 2 weeks, 83±9% after 3 weeks and 77±3% of 14C labeled ZA after 4 weeks of in-vivo implantation. Discussion. Improved carriers and better knowledge of the release might improve the effect of bone active drugs in orthopedics. Our previous study shows that an off-the-shelf ceramic biomaterial combined with ZA alone or with both rhBMP-2 and ZA can be used to regenerate bone with potential for clinical translational. This study demonstrates long-term co-delivery of both rhBMP-2 and ZA in-vivo via the biomaterial. Constant availability of rhBMP-2 over a long period of time can give osteoinductive properties to the material while presence of local ZA prevents premature bone loss. The pharmacokinetic release pattern differs from what we have reported in vitro with less BMP and more ZA being released in vivo during the first 4 weeks. We speculate that rapid protein passivation of the ceramic material slows the release of BMP and partly preventing the ZA binding to apatite


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 248 - 248
1 Sep 2005
Stolle L Arpi M Holmberg-Jørgensen P Riegels-Nielsen P Keller J
Full Access

Objectives: Antimicrobial agents exert their effect inside the interstitial space, which is the site of many infections. Recently, microdialysis was applied to cortical and cancellous bone for the evaluation of gentamicin. The principle of microdialysis is to introduce a semipermeable membrane into bone and perfuse it with liquid, thus enabling dynamic measurements to be made. The aim of this investigation was to measure pharmacokinetics of a Gentacoll sponge in bone tissue by microdialysis. Materials and Methods: Nine pigs were randomized to either wet or dry application of a Gentacoll sponge (10cm* 10cm) into the bone marrow of tibia. Two catheters were inserted into cancellous bone tissue, one 1 cm (MD. 1cm. ) and one 2 cm (MD. 2cm. ) apart from the aimed location of the sponge. Then, the Gentacoll sponge was implanted. Wet application was defined as; the sponge was wetted in 2 mL. blood. Dry application was defined as usual surgical procedure. Concentrations of gentamicin were measured in serum and microdialysates on an Abbott Drug Analyser. Data presented are median (range). A rank sum test was performed for statistical analysis. A p-value below 0,05 was considered significant..AUC describes the total amount of gentamicin that passed though the tissue. Results: The AUC. 6h, serum wet. was 92 (72–129) and AUC. 6h, serum dry. was 196 (142–626) mg*minute/L (P=0.02). The C. peak, wet-group. was 120 mg/L (33–585) and C. peak, dry-group. 178 mg/L(59–1294), (P=0.31). The overall (n=9) AUC. MD1cm. was 24431 mg*minute/L (5.155–152.855) and similar the AUC. MD2cm. 13759 mg*minute/L (6.351–74.573) (P=0,25). The C. peak, MD 1cm. was 106 (41–354) (P=0.21). was 209 (33–1294) and C. peak, MD 2cm. Conclusions: This first study applied microdialysis for pharmacokinetic measurements of a local implant. The distribution of local applied antibiotics into bone tissue is difficult to measure. The small sample size precludes a detailed analysis, but previous found variation on the distribution of gentamicin from a Gentacoll sponge is reproduced in this work. It seems that neither application nor distance had impact on the initial pharmacokinetic of Gentacoll in bone tissue


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 80 - 80
1 Dec 2019
Thomassen M Hanberg PE Stilling M Kjær K S⊘balle K Krag L H⊘jskov C Bue M
Full Access

Aim. Local treatment with gentamicin may be an important tool in the prevention and treatment of surgical site infections in high-risk procedures and patients. The aim of this study was to evaluate the pharmacokinetic profile of gentamicin in bone and surrounding tissue, released from a controlled application of a GentaColl sponge in a porcine model. Method. In 8 female pigs, a GentaColl sponge of 10×10 cm (1.3 mg gentamicin/cm. 2. ) was placed in a cancellous bone cavity in the proximal tibia. Microdialysis was used for sampling of gentamicin concentrations over 48 hours from the cavity with the implanted GentaColl sponge, cancellous bone parallel to the cavity over and under the epiphyseal plate, cortical bone, the intramedullary canal, subcutaneous tissue, and the joint cavity of the knee. Venous blood samples were obtained as reference. Results. The main finding was a mean peak drug concentration (95-CI) of gentamicin in the cancellous bone cavity containing the implanted GentaColl sponge of 11,315 (9,049–13,581) μg/ml, persisting above 1000 μg/ml until approximately 40 hours after application. Moreover, the concentrations were low (< 1 μg/ml) in the surrounding tissues as well as in plasma. Conclusions. The mean peak gentamicin concentration from the cancellous bone cavity after a controlled application of a GentaColl sponge was high and may be adequate for the prevention of biofilm formation. However, high MIC strains and uncontrolled application of the GentaColl sponge may jeopardize this conclusion


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 52 - 52
1 Oct 2019
Korte EA Malkani AL Gaskins J Hartley B Langman LJ Jannetto P McMillin G Maluf C Jortani SA
Full Access

Introduction. Insufficient pain control following lower extremity surgery can increase length of stay, readmission rates, and impair postoperative outcome. It has been shown that CYP2D6 genotypes predict function of the enzyme responsible for conversion of hydrocodone to hydromorphone (active metabolite) and plasma concentration of hydromorphone best predicted analgesic response. Purpose of this study was to evaluate relationship of CYP2D6 genotypes, drug-drug interactions, and plasma drug concentrations in patients undergoing lower extremity surgery. Methods. A prospective cohort of 271 orthopedic patients undergoing lower extremity surgery including TKA, THA and trauma were queried. Patients treated with hydrocodone were enrolled and tested for plasma concentrations of hydrocodone and hydromorphone. CYP2D6 genotyping was performed. Medications co-administered with hydrocodone during perioperative and postoperative periods were queried. Results. Out of 271 patients enrolled, only 41 (15%) had detectable hydromorphone (i.e. >0.5 ng/mL). 86% were extensive (normal) metabolizers, 7% were intermediate metabolizers, 5% poor metabolizers and 2% were ultra rapid metabolizers. 179 subjects were not administered any inhibitors of CYP2D6 whereas 92 were on at least one inhibitor. 33 (18%) with no pharmacological inhibitors had detectable hydromorphone, whereas only 7 (7.6%) on inhibitors had hydromorphone detected above the lower limit of quantification (0.5ng/mL), p=0.033. Diphenhydramine, fluoxetine, hydralazine, duloxetine, bupropion and sertraline, were the most common CYP2D6 inhibitors co-administered with hydrocodone in this cohort. Conclusions. Patients' home medications and selection of various drugs in the postoperative setting could impact the pharmacokinetics and pharmacodynamics of hydrocodone leading to a diminished analgesic response. We conclude that health care providers should become familiar with the inhibitors of CYP2D6 to obtain the best response with the use of hydrocodone following lower extremity surgery. Additional work is required to determine the ideal opioid for an individual patient's genotype following lower extremity orthopedic surgery. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 20 - 20
1 Dec 2019
Hanberg PE J⊘rgensen AR Stilling M Thomassen M Bue M
Full Access

Aim. Cefuroxime is a time-dependent antibiotic widely used as intravenous perioperative prophylaxis in spine surgery. A previous study has indicated that a single dose of cefuroxime provided insufficient spine tissue concentrations for spine procedures lasting more than 2–3 hours. Due to the fact that postoperative pyogenic spondylodiscitis is associated with prolonged antimicrobial therapy and high relapse rates, we aimed to evaluate if a twofold increase of standard dosage of 1.5g cefuroxime given as one double dose or two single doses with 4-hours intervals will lead to sufficient cefuroxime spine tissue concentrations throughout the dosing interval. Method. This is preliminary data for 8 out of 16 female pigs. Data from all 16 pigs will be included for the conference. Eight pigs were randomized into two groups: Group A received one double dose of cefuroxime (3g) as a bolus, and Group B received two single doses of cefuroxime (2×1.5g) with 4-hours intervals. Measurements were obtained from plasma, subcutaneous tissue (SCT), vertebral cancellous bone and the intervertebral disc (IVD) for 8-hours thereafter. Microdialysis was applied for sampling in solid tissues. The cefuroxime concentrations were determined using ultra-high performance liquid chromatography. Results. The time with concentrations above the minimal inhibitory concentration (T>MIC) for the clinical breakpoint MIC for Staphylococcus aureus of 4 μg/ml, was superior in all compartments when administering cefuroxime as two single doses with 4-hours intervals. For the target MIC of 4 μg/ml, the mean T>MIC in all compartments ranged between 53–73% and 85–95% for Group A and B, respectively. For both groups the area under the concentration-curve (AUC) was higher for plasma compared to the remaining compartments, and the lowest AUCs were found in the vertebral cancellous bone and the IVD. There were no differences in AUC between the two groups. Furthermore, the maximal concentrations were lower for both vertebral cancellous bone and IVD compared to both SCT and plasma. When comparing the two groups, higher maximal concentrations were found in all compartments for Group A. Tissue penetration was incomplete and delayed for all compartments and comparable between the two groups. Conclusions. Despite comparable pharmacokinetic results between the two groups, Group B exhibited superior T>MIC in all compartments for the clinical breakpoint MIC for Staphylococcus aureus of 4 μg/ml. As such administration of cefuroxime as two single doses with 4-hours intervals provided sufficient cefuroxime spine tissue concentrations for a minimum of 85% of an 8-hour dosing interval, which may be acceptable for most spine procedures


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 51 - 51
1 Oct 2019
Hamilton WG Parks NL Gargiulo JM
Full Access

Introduction. Pharmacogenetics evaluates a patient's DNA to determine if a particular drug is expected to have a normal clinical effect, heightened effect, or no effect at all on a patient. It may also predict which patients are most likely to experience side effects from the medications. The purpose of this study was to use pharmacogenetic testing to determine how frequently total knee arthroplasty (TKA) patients have genetic variants to standard postoperative pain medications. We further sought to determine if changing the multimodal program based on these results would improve pain control and reduce side effects. Methods. In this prospective, randomized study, buccal cheek swab samples were collected from 31 primary TKA patients. Pharmacogenetics testing was performed on the samples to examine genetic variants in genes OPRM1, CYP1A2, CYP2B6, CYP2C19, CYP3A4, CYP2C9, and CYP2D6. These genes affect the pharmacodynamics and pharmacokinetics of NSAIDs and opioids. We examined the frequency of a genetic variant to one of the multimodal medications we prescribe including celecoxib, hydrocodone, and tramadol. Subjects included 9 men and 22 women. Patients were randomized to one of two groups: the control group received the standard postoperative pain regimen; the study group received a customized regimen based on the pharmacogenetic results. For the first 10 postoperative days patients recorded pain scores, amount of pain medication taken, and any side effects experienced. Results. Genetic variations to one or more medications in our standard postoperative pain management protocol occurred in 13 of the 31 patients (42%). 8 patients (26%) had a variation of gene CYP2C9 affecting celecoxib. 11 patients (35%) had a variation of gene OPRM1 and/or CYP2D6 affecting the response to hydrocodone. 4 patients (13%) had a variation of gene CYP2D6 that altered their response to tramadol. Of the 31 patients tested, only 18 (58%) had no genetic variants related to the pain medications we routinely prescribe. 8 patients (26%) had variants affecting more than one of the medications. (Table 1, below) Both the average pain levels and morphine equivalents consumed in the first 10 days were higher in the control group than in the study group. Conclusion. 42% of patients in this study demonstrated a pharmacogenetic variant to one of the commonly used multimodal pain medications. Our early data suggests that customizing pain regimens based on this information can help reduce pain and the amount of pain medication used postoperatively. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 6 - 6
1 Dec 2017
Bouige A Fourcade C Bicart-Sée A Félicé M Gautié L Krin G Marlin P Giordano G Bonnet E
Full Access

Aim. Ceftobiprole, a broad-spectrum cephalosporin, could be used for post-operative treatment of bone implant-associated infections. The aim of the study is to evaluate the in vitro susceptibility of bacteria isolated from bone implant-associated infections to ceftobiprole. Method. We conducted an in vitro, retrospective and comparative study between July 2013 to April 2017 including patients with bone implant-associated infections (prosthesis joint infection (PJI) and osteosynthesis material (OM)). To evaluate MIC distribution of ceftobiprole against Gram positive and Gram negative strains and to compare activity of ceftobiprole to vancomycin for Gram positive and ceftriaxone or ceftazidime for Gram negative strains, we tested all strains (stored in Cryobank storage system) for minimal inhibitory concentrations (MIC) determination by E-test bandelet for ceftobiprole and comparator antibiotics. Results. We collected 63 Gram negative strains (57 Enterobateriaceae and 6 Pseudomonas aeruginosa), isolated from 25 patients with OM and 38 patients with PJI (23 hips and 15 knees), and 100 Gram positive strains (85 Staphylococcus sp, 8 E. faecalis, 7 Propionibacterium sp.) isolated from 38 patients with OM and 62 patients with PJI (33 hips, 28 knees, 1 shoulder). A total of 61.4% of Enterobacteriaceae were susceptible both with ceftobiprole and ceftriaxone, 100% of P. aeruginosa were susceptible with ceftazidime and 83,3% with ceftobiptrole and finally 100% of Gram positive were susceptible both with ceftobiprole and vancomycin (susceptibility interpretation was based on EUCAST breakpoints). Conclusions. Our results suggest that ceftobiprole has a good in vitro activity against strains isolated from bone implant-associated infections. It could be an effective alternative to vancomycin and ceftriaxone or ceftazidime in post-operative treatment but pharmacokinetics and pharmacodynamics studies must be performed in bone tissue


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 77 - 77
1 Dec 2016
Tøttrup M Bue M Koch J Jensen LK Hanberg P Aalbæk B Fuursted K Jensen HE Søballe K
Full Access

Aim. A reason for treatment failure, in cases of periprosthetic bone infections and osteomyelitis, may be incomplete or heterogeneous tissue distribution of antimicrobials to the affected bone. Decreased bioavailability has been demonstrated in healthy bones but never in pathological bone tissue. Therefore, the aim was to obtain pharmacokinetic parameters of cefuroxime in infected bone tissue by means of microdialysis in a porcine model of implant associated osteomyelitis. Method. An implant cavity of 4 mm in diameter was drilled 25 mm into the right tibial bone of ten pigs (30 kg/BW). Subsequently, a small steel implant (K-wire 2 × 2 mm) and 10. 4. CFU of Staphylococcus aureus was inserted and injected into the implant cavity. Five days after inoculation, two additional drill holes of 2 × 25 mm were drilled into the trabecular bone tissue adjacent to the implant cavity and into the left uninfected tibia. After intravenous administration of 1500 mg of cefuroxime, the concentration was measured in plasma and in the three tibial drill holes for 8 hours. All measurements were performed with microdialysis. Post mortem, the presence of bone infection was assessed by computed tomography (CT) scans and cultures of swabs. Results. Destruction of bone tissue was seen on CT scans around all implant cavities but not in the adjacent trabecular bone tissue of the right leg or in the left leg. All swabs from the implant cavity and 8/10 swabs from the adjacent trabecular tissue were positive for S. aureus. Conversely, all swabs from the left tibia were negative. The area under the concentration-time curves differed significantly, with the lowest found in the implant cavity (P<0.001). Although not significant, cefuroxime penetration into the adjacent bone tissue was incomplete. Conclusions. This is the first study to show, by microdialysis, that the destructive bone processes associated with implant associated osteomyelitis significantly impair cefuroxime penetration. Our results support the clinical conception of fast diagnosis and initiation of antibiotic treatment if surgery is to be avoided. It is of crucial importance to know the exact level of antibiotics, which actually reaches a pathological bone focus in order to obtain more targeted and effective antibiotic treatments of bone infections