Advertisement for orthosearch.org.uk
Results 1 - 20 of 1395
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 50 - 50
1 Mar 2013
De Biase CF Delcogliano M Borroni M Gumina S Postacchini F Castagna A
Full Access

Introduction. the aim of the study is to evaluate the clinical results of the shoulder prosthesis revision procedure to reverse implant without removing the humeral stem using a modular system (Lima LTD) and determine if this procedure is beneficial for the patients. Methods. e selected only the patients where a revision to reverse (RSA) of hemiarthroplasty (Hemi) originally implanted for fracture (Group I) and revision to reverse (RSA) of anatomical total prosthesis (TSA) were performed. From 2004 to 2009 26 cases responding to these parameters were identified: 18 cases in Group I (failed hemiarthroplasty for tuberosities resorptions or rotator cuff failure) and 8 in Group II (failed TSA for rotator cuff omplication). The mean follow-up was 32 months (min 18–max 76) and the mean age was 72 (min 65–max 80). Clinical assessment was performed with preoperative and postoperative Constant score rating scale (CS) and range of motion evaluation (ROM). Radiological assessment was performer by AP and Axial X-ray views. Operative time was calculated. Results. overall pre-op CS was 24 (min 18–max 30), post-op CS was 47,8 (min 35–max 60). In Group I the mean improvement of CS was 25,3; in Group II was 17. All patients had a clinical improvement of the range of motion. X-Rays study did not show radiolucent lines related to implant mobilization. No major complications were observed in all the cases. Discussion and Conclusion. Revision surgery for failed Hemi or TSA is commonly related to a relatively increase of complication and/or poorer out come if compared to a primary RSA implant. Our study results demonstrate that using a full modular system from the first implant allows to skip the humeral stem removal/reimplant step in case of conversion of a shoulder prosthesis to a reverse with good clinical result, no radiological signs of mobilization and non major complication probably related to a shorter and less aggressive operative time and procedure


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 15 - 15
1 Jan 2016
Shishido T Kubo K Tateiwa T Masaoka T Yamamoto K
Full Access

Introduction

In most cases of revision acetabular total hip arthoplasty (THA), some degree of bone loss will be accompanied. If the bone loss is massive, the management of bone defect is more challenging problem. We consider that using cementless accetabular cup for revision acetabular reconstruction is good indication when stable interface fit between the acetabular cup and bone is achieved. The purpose of this study is to review the result of revision hip arthroplasty using cementless acetabular cup with and without bone graft.

Materials and methods

Between 1998 and 2012, 65 revisions using cementless acetabular cup (Mallory-Head 4 Finned component) were performed in 64 patients, whose mean age was 64.9 years. The cases of revision are aseptic loosening (53 joints), and infection (12 joints). All patients were followed up for a minimum period of 24.0 months (mean, 84 months) and were divided into two groups as follows: in group A, revisions without bone graft (28 joints); in group B, revisions with bone graft (37 joints). We compared clinical and radiographical results of group A with group B.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 161 - 161
1 Mar 2006
Sosin P Dutka J Libura M Skowronek P
Full Access

Aims: Evaluation of: 1/ type and incidence of pelvic ring injuries, 2/ type and incidence of associated injuries, 3/ type of pelvic ring injuries pathomechanism, 4/ influence of pelvic ring injuries on trauma severity score, 5/ analysis of clinical long term results. Material and methods: Retrospective evaluation of 257 patients with pelvic ring injuries treated between 1989–2003 had been made. Mean patients age was: 65 y.o. (Range: 32–61 y.o.). Mean follow-up time: 57,5 months (range: 18–192 m.). All patients were treated no operatively: bed-rest, hamaque suspension, and skeletal traction. Analysis of pelvic injuries was made by Tiles classification. Evaluation of pelvic injuries pathomechanism was made by Young-Burgess classification. Clinical end results were evaluated by Iowa Pelvic Score. In polytraumatized patients trauma severity was evaluated by AIS and ISS. Results: Incidence of pelvic injury in hospitalized patients was 1,3%. In study group there were following pelvic injury types: type A – 14 %, type B – 77 % and type C – 9%. Pathomechanisms of pelvic injuries in study group were following: type LC – 61%, type APC – 30%, type VS – 2%, type CMI – 7%. Long term clinical results in Iowa pelvic Score were for pelvic ring injuries: type A – 92 p., type B – 86 p., type C – 67 p. Mean value of ISS index in patients with pelvic ring injuries was 23p, mean value of ISS index in patients without pelvic ring injuries was 19p. Conclusions: 1/ pelvic ring injuries in standard orthopedic and traumatic department are rare, 2/ pelvic ring injuries are frequent in polytraumatized patients, 3/ type C according to Tile’s classification is the most frequent type of pelvic ring injury, 4/ type LC according to Young-Burgess classification is the most frequent type of pelvic ring injury pathomechanism, 5/ incidence of pelvic ring injury in polytraumatized patient increases ISS index, 6/ long term clinical results suggested that most pelvic ring injuries can be successfully treated nonoperatively


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 535 - 535
1 Oct 2010
Daniilidis K Fischer F Skuginna A Skwara A Tibesku C
Full Access

Aim: Cementation of tibial implants in total knee arthroplasty is a gold-standard considering the high loosening rates of cementless implants. In contrast, only sparse data exist regarding unicondylar arthroplasty due to limited use. In this study, we compare cemented with cementless unicondylar knee arthroplasty and aim to define both clinical and radiological differences in treatment outcome. Materials and Methods: In a retrospective study, 106 patients who had undergone a medial unicondylar replacement were examined after a mean postoperative period of 8 years. Of these, 42 patients (median age 81±7 years) had received a cemented and 64 (median age 73±7 years) a cementless knee arthroplasty by the same surgeon while 7 patients were deceased or could not be reached. Well-established clinical (VAS, HSS, KSS, UCLA, WOMAC) and quality of life (SF-36) scores were used to evaluate treatment outcome. X-rays were performed to evaluate periprosthetic loosening zones, according to Ewald’s criteria. Results: The cementless patient group presented significantly better clinical scores (HSS, KSS, UCLA, WOMAC), except in the Visual Analogue Scale (VAS) for pain assessment. The quality of life was significantly better in the cementless group except in the subgroups concerning physical function, vitality and social role, which resembled normal population. Moreover, radiographic analysis using antero-posterior X-rays revealed significantly more and larger periprosthetic loosening areas in tibial zone 2 in the cementless group. Conclusion: The inferior clinical results characterising the cemented group could be attributed to the higher mean age. Regarding the radiological loosening zones, we did not detect any differences in the techniques of fixation, although physical activity and mechanical stresses were higher in the cementless group


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 17 - 17
1 Mar 2017
Steppacher S Milosevic M Lerch T Tannast M Ziebarth K Siebenrock K
Full Access

Introduction. Hips following in-situ pinning for slipped capital femoral epiphysis (SCFE) have an altered morphology of the proximal femur with cam type deformity. This deformity can result in femoroacetabular impingement and early joint degeneration. The modified Dunn procedure allows to reorientate the slipped epiphysis to restore hip morphology and function. Objectives. To evaluate (1) hip pain and function, (2) 10-year survival rate and (3) subsequent surgeries and complications in hips undergoing modified Dunn procedure for SCFE. Methods. Between April 1998 and December 2005 we performed the modified Dunn procedure for 43 patients (43 hips) with SCFE. Twenty-five hips (58) presented with an acute or acute on chronic slip. The mean slip angle was 43° (range, 15° – 80°). A majority of 53% of procedures were performed in male patients and the mean age at operation was 13 years (10 – 19 years). We could followup all except one hip (followup of 5.5 year) for a minimum of 10 years (mean followup 13 [10 – 18 years]). We used the anterior impingement test to assess pain and the Merle d'Aubigné- ostel score to assess function. Survivorship calculation was performed using the method of Kaplan and Meier and any of the following factors as a definition of failure: radiographic evidence of worsening osteoarthritis (OA), or a Merle d'Aubigné-Postel score less than 15. Results. (1) The prevalence of a positive anterior impingement test decreased from 100% to 16% (p<0.001). The mean Merle d'Aubigné-Postel score improved from 13 (7 – 14) to 17 (14 – 18) at most recent followup (p<0.001). (2) Four hips (9%) showed progression of OA and three hips (7%) had a Merle d'Aubigné-Postel score of less than 15 at most recent followup. This resulted in a 93% survival rate at 10-year followup. (3) No hip developed avascular necrosis. Five hips (12%) had complications with reosteosynthesis due to screw breakage or nonunion. Another nine hips (21%) had subsequent surgeries including acetabular rim trimming / offset creation in 5 hips and screw removal in 4 hips. Conclusion. The modified Dunn procedure is a safe method to correct the morphology of the proximal femur in hips with SCFE. Ninety-free percent of the hips showed no progression of OA and a good clinical result at the 10-year followup. Twelve percent required revision surgery for complications all including screw breakage with nonunion of the greater trochanter


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 63 - 63
23 Jun 2023
Czubak J Kołodziejczyk K Czwojdziński A Czubak-Wrzosek M
Full Access

The aim of the study was to evaluate radiological and clinical outcomes of surgical treatment of developmental dysplasia of the hip (DDH) with Periacetabular Osteotomy (PAO) and to determine the values of radiological parameters allowing us to obtain an optimal clinical result. Radiological evaluation included a standardized AP digital radiograph of the hip joints. Centre edge angle (CEA), medialization, distalization, femoral head coverage (FHC) and ilioischial angle were measured. Clinical evaluation based on HHS, WOMAC, Merle d'Aubigne-Postel scales and Hip Lag Sign. Radiological and clinical evaluation was performed preoperatively and approximately 12 months after the surgery. Statistically significant (p<0.05) differences in radiological measurements and all clinical scales have been observed pre- and postoperatively for all of the parameters. The results of PAO presented decreased medialization by 3.4mm (range: 3 to 3.7), distalization by 3.5mm (range: 3.2 to 3.8) and the ilioischial angle by 2.7° (range: 2.2 to 3.7). There was also an improvement in the femoral head bone coverage: CEA increased by 16.3° (range: 12.1˚ to 20.5˚) and FHC by 15.2% (range: 10.8 to 19.8). Clinically we observed an increase in HHS by 22 points (range: 15.8 to 28.2) and M. Postel d'Aubigne by 3.5 points (range: 2.0 to 4.4) and a decrease in WOMAC by 24% (range: 22.6 to 25.8). HLS improvement of gluteal muscles’ efficiency has been observed in 67% of patients postoperatively. This study revealed that the qualification of patients with DDH for an elective PAO is more justified due to the predicted optimal clinical outcomes based on three parameters: CEA <25 degrees, FHC <75%, and ilioischial angle >85.9 degrees. Accordingly, to achieve better clinical results for all scales, it is necessary to increase the average CEA value by 11˚, the average FHC by 11%, and reduce the average ilioischial angle by 3˚


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 31 - 31
23 Feb 2023
Hong N Jones C Hong T
Full Access

Ideberg-Goss type VI/AO F2(4) glenoid fossa fractures are a rare and complex injury. Although some advocate non-operative management, grossly displaced glenoid fossa fractures in the young patient may warrant fixation. Current approaches still describe difficulty with access of the entirety of the glenoid, particularly the postero-superior quadrant. We present 2 cases of Ideberg-Goss type VI/AO F2(4) glenoid fossa fractures treated with fixation through a novel “Deltoid Takedown” approach, which allows safe access to the whole glenoid with satisfactory clinical results at 5 and 7 years respectively


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 67 - 67
1 Nov 2021
Zaffagnini S
Full Access

The medial opening-wedge high tibial osteotomy (OW-HTO) is an accepted option to treat the isolated medial compartment osteoarthritis (OA) in varus knee. Despite satisfactory outcomes were described in literature, consistent complication rate has been reported and the provided accuracy of coronal alignment correction using conventional HTO techniques falls short. Patient specific instrumentations has been introduced with the aim to reduce complications and to improve the intra-operative accuracy according to the pre-operative plan, which is responsible for the clinical result of the surgery. In this talk, an overview of the clinical results of HTO patient specific instrumentation available in literature will be performed. Moreover, preliminary intra-operative and clinical results of a new customised 3-D printed cutting guide and fixation plate for OW-HTO will be presented


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 95 - 95
11 Apr 2023
Dickson S Fraser E O'Boyle M Mansbridge D
Full Access

Neck of femur fracture (NOF#) is the commonest reason for admission to an orthopaedic ward with 70-75,000 cases each year in the UK. 1. The femoral head is often sent to pathology if there is clinical suspicion of a malignant cause. There is limited evidence in the literature to support the efficacy of this. 2. The purpose of this project was to study the incidence of femoral head pathology analysis in NOF # patients with a background of malignancy and evaluate the impact this investigation has on guiding future management. Retrospective analysis of all neck of femur fractures admitted to the Queen Elizabeth University Hospital between 01/01/2021 and 31/12/2021. The electronic notes were accessed and for patients with past medical history of malignancy, it was confirmed whether femoral head or bone reamings were sent to pathology, resultant findings and the impact on subsequent management. In 2021, 784 patients were admitted to the QEUH with a NOF#. Of these, 770 (98.2%) underwent operative management, 138 (17.3%) of whom had a past medical history (PMH) of malignancy. Intra-operative pathology was sent from 19 (13.7%) of these 138 patients. No malignant cells were found in 13 (69%) samples, and in 6 (31%), the known active malignancy was confirmed. In all cases where samples were sent for pathology, none caused any change in management. In this retrospective study, pathological investigations in NOF# patients with a PMH of malignancy had no impact on further management. The authors would not advocate for sending pathology results in this cohort group


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 13 - 13
10 Feb 2023
Giurea A Fraberger G Kolbitsch P Lass R Kubista B Windhager R
Full Access

Ten to twenty percent of patients are dissatisfied with the clinical result after total knee arthroplasty (TKA). Aim of this study was to investigate the impact of personality traits on patient satisfaction and subjective outcome of TKA. We investigated 80 patients with 86 computer navigated TKAs (Emotion®, B Braun Aesculap) and asked for patient satisfaction. We divided patients into two groups (satisfied or dissatisfied). 12 personality traits were tested by an independent psychologist, using the Freiburg Personality Inventory (FPI-R). Postoperative examination included Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and the Visual Analogue Scale (VAS). Radiologic investigation was done in all patients. 84% of our patients were satisfied, while 16% were not satisfied with clinical outcome. The FPI-R showed statistically significant influence of four personality traits on patient satisfaction: life satisfaction (ρ = 0.006), performance orientation (ρ =0.015), somatic distress (ρ = 0.001), and emotional stability (ρ = 0.002). All clinical scores (VAS, WOMAC, and KSS) showed significant better results in the satisfied patient group. Radiological examination showed optimal alignment of all TKAs. There were no complications requiring revision surgery in both groups. The results of our study show that personality traits may influence patient satisfaction and clinical outcome after TKA. Thus, patients personality traits may be a useful predictive factor for postoperative satisfaction after TKA


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 31 - 31
1 Nov 2022
Ahmed N Norris R Bindumadhavan S Sharma A
Full Access

Abstract. Background. We know that tears of the Triangular fibrocartilage complex (TFCC) can cause DRUJ instability and ulnar sided wrist pain. This study shows the clinical result of patients who had arthroscopic transosseous repair of the TFCC tear with DRUJ instability. Arthroscopic repair of TFCC tear is a promising, minimally invasive surgical technique especially in patients with DRUJ instability. Materials and methods. Fifteen patients who underwent TFCC one tunnel repair form 2018–2021 were reviewed retrospectively in hospital. The proximal component of TFCC was repaired through arthroscopic one- tunnel transosseous suture technique. VAS score for pain, wrist range of motion, grip strength and post operative complications were evaluated and each patient was rated according to the DASH score. Results. The patients had a TFCC tear confirmed on MRI and was confirmed on arthroscopy by doing a hook test. The patients were followed up for 6 months. Twelve patients had normal stability of DRUJ and three patients showed mild laxity compared with the contralateral side. The mean VAS score reduced from 4.7 to 0.8 (P=0.001) and grip strength increased significantly. The quick DASH score (P=0.001)also showed significant functional improvement. No surgical related complications occurred. Conclusions. Arthroscopic one tunnel transosseous TFCC foveal repair can be an excellent and safe method for repair of TFCC tear with DRUJ instability. Its a good treatment option in terms of reliable pain relief, functional improvement and reestablishment of DRUJ stability


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 2 - 2
16 May 2024
Schwagten K
Full Access

Background. Iatrogenic hallux varus is a rare complication after hallux valgus surgery. Operative treatment comprises a wide variety of techniques, of which the reversed transfer of the abductor hallucis tendon is the most recent described technique. Methods. This paper will present the long-term clinical results of the reversed transfer of the abductor hallucis longus. Therefore, we performed a prospective clinical observational study on 16 female patients. Our hypothesis is that the tendon transfer will persist in a good alignment and patient satisfaction on long term. There is a 100% follow-up rate with a range from 10 to 101 months. Patients were subjected to a clinical examination, three questionnaires and their general satisfaction. Results. Out of 16 patients, at time of follow-up, we found a positive correlation between the subjective outcome score and alignment (r = 0.59), and between the general satisfaction and alignment (r = 0.77). Based on the general satisfaction we achieved a success satisfaction rate of 69% (11 patients). The other 31% (5 patients) patient group was only satisfied with major reservations or not satisfied at all. The two most invalidating complications were a coronal or sagittal malalignment or the combination of both. Conclusion. Our results suggest that the reverse abductor hallucis tendon transfer is a good technique to treat a supple iatrogenic hallux varus with an observed success satisfaction rate of 69% at a mean follow-up time of 48 (range 10–101) months. However, patients should be informed that on the long-term loss of correction is possible


Full Access

Abstract. INTRODUCTION. 10% of patients with knee osteoarthritis (OA) have disease confined to the patellofemoral joint (PFJ). The main surgical options are total knee replacement (TKR) and PFJ replacement (PFJR). PFJR has advantages over TKR, including being less invasive, bone preserving, allowing faster recovery and better function and more ‘straight forward’ revision surgery. We aim to compare the clinical results of revised PFJR with primary TKR taking into consideration the survival length of the PFJR. METHODOLOGY. Twenty-five patients (21 female) were retrospectively identified from our arthroplasty database who had undergone revision from PFJR to TKR (2006–2019). These patients were then matched with regards to their age at their primary procedure, sex and total arthroplasty life (primary PFJ survival + Revision PFJ time to follow up) up to point of follow-up with a group of primary TKRs implanted at the same point as the primary PFJR. RESULTS. Mean survival of the PFJs revised were 4.2 years. In the PFJR revision group (mean arthroplasty life 7.8 years) mean Oxford knee score (OKS) at latest follow up was 27.8. In the primary knee group (mean arthroplasty life 7.5 years) mean OKS was 32.4. This difference was not statistically significant. All PFJR revisions were performed using primary prostheses. CONCLUSION. PFJR provides comparable clinical outcome even after revision surgery to TKR as primary TKRs at midterm follow up and should be considered in all patients meeting the selection criteria. Given comparable proms and straight forward revisions, staged arthroplasty to preserve bone-stock is a reasonable choice


Dual mobility cups (DMC) reduce the risk of dislocation in femoral neck fractures (FNF). Direct anterior approach (DAA), historically promoted for better stability, has been developed in recent years for better functional results. The aim of this study was to compare the early functional results of DMC in FNF by DAA versus posterolateral approach (PLA). A prospective study was conducted on a continuous series of patients who received DMC for FNF by DAA or PLA. The primary endpoint was Harris Hip Score and Parker score assessed at the first follow-up visit. Intraoperative complications were collected during hospitalization. One year clinical results and all cause revision rate were also collected. Radiographic data of cup positioning and limb length were evaluated. Fifty-two patients were included in the DAA group and 54 in the PLA group. Two patients were lost to follow-up. The mean age was 72.8 years. There was no significant difference in HHS or Parker score at 3 and 12 months follow up (p=0.6, p= 0.75). DAA was associated with more intraoperative complications with 4 fractures and 1 femoral nerve deficit (p=0.018). There were 3 revisions in the DAA group (1 infection, 1 dislocation, 1 peri prosthetic fracture) and 1 in the PLA group (infection), which was not statistically significant (p=0.34). Cup anteversion was 6° greater and inclination 9° lesser in DAA group (p=0.028, p<0.01). Results suggest that DAA does not provide any early functional benefit in THA-DMC for FNF compared to PLA. It could lead to more intraoperative complications and a higher revision rate. DAA requires an experienced surgeon and careful patient selection


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 26 - 26
2 Jan 2024
Legerlotz K
Full Access

As high incidences of tendinopathies are observed particularly in those who intensively use their tendons, we assume that pathological changes are caused, at least partially, by mechanical overload. This has led to the so-called overload hypothesis, explaining the development of tendinopathies by structural failure resulting from excessive load. At the same time, tendon loading is an important part in tendon rehabilitation. Currently, exercise treatment approaches such as eccentric training or heavy load resistance training are widely applied in tendinopathy rehabilitation, with good clinical results such as an improvement in function and a reduction in pain. Particularly those rehabilitative approaches which impose high strains on the tendon may induce an adaptation of the tendon's mechanical properties such as increased tendon stiffness. An increased tendon stiffness is often interpreted as desirable, as it may protect the tendon from overloading and thus prevent future strain injuries. However, the tendinopathic tendon is not necessarily less stiff than the tendon in the contralateral leg and an improvement in tendon stiffness is not necessarily accompanied by an improvement in tendon pain or function. In addition, metabolic factors, resulting e.g. in low-level systemic inflammation, may contribute to pathological tendon tissue changes and are not necessarily affected by an exercise program, while nutritional interventions or dietary supplements may potentially affect tendon cell metabolism. Indeed, dietary supplements have been introduced as an additional therapeutic approach in the treatment of tendinopathies in recent years, and their positive curative effects have been reported for both the general population and athletes. In the management of tendinopathies, it may thus be advisable if therapeutic approaches aim to address both tendon mechanics and tendon metabolism for better treatment effectiveness and a sustainable improvement in pain and function


Highly cross-linked polyethylene (HXLPE) has decreased wear and revision rates in total hip replacement (THR) at a long-term. However, the effect of HXLPE manufacturing characteristics on femoral head penetration has not been clearly defined yet. We report this single-institution study to investigate the clinical and radiological results of different HXLPE liners in THR. In this retrospective cohort analysis of our prospective database, we identified 904 THRs performed between 2000 and 2013. Seven different HXLPE liner types were assessed: remelted (3), annealed (2), sequentially annealed (1) and vitamin E-infused (1). The linear femoral head penetration rate was measured at six weeks, one year, and annually thereafter, using the Roman Software v1.70 package. Thirty hips were revised for the following reasons: aseptic loosening (11), dislocation (12), periprosthetic femoral fracture (6), and infection (1). No hip was revised for wear or osteolysis. 741 THRs were evaluated for a mean follow-up of 15 years (range, 10 to 20). The mean total penetration 15 years after THR was 0.17 mm in the sequentially annealed, and 0.16 mm in the vitamin E-infused groups, whereas it was 0.26 mm in the melted 95 kGy, 0.27 mm in the melted 5 Mrad and 0.25 mm in the melted 100 kGy groups (p=0.001). From one to 15 years after surgery, the mean wear was 0.206 mm in cups with an acetabular inclination greater than 50º and 0.105 mm in those placed between 35º and 50º (p<0.001). Although HXLPE characteristics can result in a different wear performance in patients undergoing THR at a mean follow-up of 15 years, the clinical results are excellent. The position of the acetabular component can influence on the femoral head penetration of modern HXLPEs. Nevertheless, these patients should continue to be monitored to detect future problems


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 11 - 11
23 Jun 2023
Lombardi AV Alexander JS Berend KR Houserman DJ Adams JB Crawford DA
Full Access

Previous studies have reported excellent results with tapered, titanium alloy, porous plasma-sprayed components in patients undergoing uncemented primary total hip arthroplasty (THA). The purpose of this study was to examine survival and clinical results at minimum 25-year follow-up. We reviewed all patients who underwent primary THA at our center through 1995 with a specific femoral component, the Mallory-Head Porous (MHP; Zimmer Biomet, Warsaw, IN). This device, marketed in the U.S. until December 2021, was essentially unchanged since its 1984 introduction, except the porous coating was continued circumferentially along the lateral aspect in 1987, a hydroxyapatite-coated option was offered in 1988, and an offset option was added in 1999 after the study period. Three hundred thirty-two patients (396 THA) had a minimum of 25-year follow-up. Mean age at surgery was 47.6 years (range, 21–70 years). Mean follow-up in non-failed patients was 28.7 years (range, 25 to 37 years). There were 31 femoral revisions (7.8%): 9 infection, 3 failure of ingrowth, 5 aseptic loosening, 8 osteolysis revised well-fixed, 2 periprosthetic fracture, 2 polyethylene wear with trochanteric avulsion, 1 component breakage, and 1 malalignment well-fixed. Kaplan-Meier survival with endpoint of stem revision for all causes was 94.8% (95% CI: ±0.9%) at 36.7 years, and survival with endpoint of aseptic loosening/failure of ingrowth was 98.7% (95% CI: ±0.5) at 36.7 years. Harris hip scores improved significantly from 43 preoperatively to 76 most recently. This tapered, titanium, porous plasma spray-coated femoral component continues to demonstrate high long-term survival with a low rate of femoral component revision for any reason or aseptic loosening/failure of ingrowth


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 14 - 14
10 Feb 2023
Vertesich K Staats K Böhler C Koza R Lass R Giurea A
Full Access

The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Aim of this study was to investigate long term results of a new RH prosthesis (EnduRo®, B Braun, Germany), which uses carbon-fiber reinforced poly-ether-ether-ketone (CFR PEEK) as a new bearing material, first time used in knee arthroplasty. Fifty-six consecutive patients, who received the EnduRo® RH prosthesis were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively as well as postoperatively after 3 and 12 months and annually thereafter. Min. Follow up was 7 and mean follow up 9,3 years. Clinical examination included Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), and range of motion (ROM). Competing risk analysis was assessed for survival with respect to indication and failure mode. KSS, WOMAC, OKS, and ROM significantly improved from the preoperative to the follow up investigations (p < 0.0001). There was no difference in clinical outcome between the primary and the revision group. The overall cumulative incidence for revision for any reason was 23.6% and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002). The evaluated RH prosthesis provided reliable and durable results with a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of cases. The use of this RH system in primary patients showed high survival rates. Long-term functional and clinical results proved to be satisfying in both revision and primary cases. No adverse events were associated with the new bearing material CFR-PEEK


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 9 - 9
23 Jun 2023
Lachiewicz PF Skalla LA Purcell KP
Full Access

Severe heterotopic ossification (grade III and IV) after contemporary total hip arthroplasty (THA) requiring excision is very uncommon. We performed a systematic review of the literature, and report a new case series with operative treatment after primary uncemented THA. A systematic review identified papers describing patients who had excision of heterotopic ossification (HO) after contemporary THA, defined as performed after 1988. Concepts of hip arthroplasty, heterotopic ossification, and surgical excision were searched in MEDLINE, Embase, and Scopus, from database inception to November 2022. Inclusion criteria were: articles that included specific patient data on grade of heterotopic ossification, operative procedure, and prophylaxis. Studies were screened for inclusion by two independent reviewers. Extracted data included demographic data, interval from index surgery to excision, clinical results, and complications. One surgeon performed reoperation for ankylosis of primary THA in three patients with severe pain and deformity. Seven case series or case report studies were included. There were 41 patients, with grade III or IV HO, that had excision, and in five patients, revision of a component was also performed. Perioperative prophylaxis was irradiation alone in 10 patients, irradiation and indomethacin in 10, and indomethacin alone in 21 patients. At a mean follow-up time of 14.8 months, definition of the results was not uniform, and range of motion was improved, but relief of pain was inconsistent. There was one dislocation, one gastrointestinal complication, and two recurrences. Treatment of the three patients, with wide excision of peri-articular bone, selective exchange of components, and peri-operative irradiation prophylaxis, was successful in improving motion and deformity. There is insufficient data on the treatment of severe symptomatic HO after contemporary THA. Prophylaxis with low-dose irradiation was successful to prevent recurrence. Multicenter studies will be needed to determine the optimum timing and prognosis for treatment


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 107 - 107
2 Jan 2024
Pastor T Zderic I Berk T Souleiman F Vögelin E Beeres F Gueorguiev B Pastor T
Full Access

Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and optimized plate-to-bone fit design. On the other hand, mini-fragment plates used in dual plating mode have demonstrated promising clinical results. However, these two bone-implant constructs have not been investigated biomechanically in a human cadaveric model. Therefore, the aim of the current study was to compare the biomechanical competence of single superior plating using the new generation plate versus dual plating with low-profile mini-fragment plates. Sixteen paired human cadaveric clavicles were assigned pairwise to two groups for instrumentation with either a 2.7 mm Variable Angle Locking Compression Plate placed superiorly (Group 1), or with one 2.5 mm anterior plate combined with one 2.0 mm superior matrix mandible plate (Group 2). An unstable clavicle shaft fracture AO/OTA15.2C was simulated by means of a 5 mm osteotomy gap. All specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis and monitored via motion tracking. Initial stiffness was significantly higher in Group 2 (9.28±4.40 N/mm) compared to Group 1 (3.68±1.08 N/mm), p=0.003. The amplitudes of interfragmentary motions in terms of craniocaudal and shear displacement, fracture gap opening and torsion were significantly bigger over the course of 12500 cycles in Group 1 compared to Group 2; p≤0.038. Cycles to 2 mm shear displacement were significantly lower in Group 1 (22792±4346) compared to Group 2 (27437±1877), p=0.047. From a biomechanical perspective, low-profile 2.5/2.0 dual plates demonstrated significantly higher initial stiffness, less interfragmentary movements, and higher resistance to failure compared to 2.7 single superior variable-angle locking plates and can therefore be considered as a useful alternative for diaphyseal clavicle fracture fixation especially in unstable fracture configurations