Abstract. Objective. To compare the
Background. As the number of primary or revision TKA with stem extension cases are growing simultaneously, the number of
Periprosthetic femur fracture (PFF) is a major complication following total hip arthroplasty (THA) that carries significant morbidity, mortality, and economic burden. Currently, uncemented stems are highly preferred in primary THA, but have been associated with higher risk of PFF compared to cemented stems. The use of collared stems in uncemented primary THA has shown promise in reducing PFF rates postoperatively. This retrospective study included 2,294 uncemented primary THAs using the posterior approach performed by two attending surgeons from January 2016 to December 2022. Both surgeons switched from a collarless femoral stem design to a collared design in May 2020. Data was collected regarding stem design, frequency of PFF, and requirement for revision surgery.
Introduction: Management of
The Lubinus SP II is an anatomical femoral stem with high survivorship levels notably described in the Swedish Arthroplasty Register. As the clinical and economic burden of revision total hip arthroplasty (THA) and
Background. Periprosthetic femoral fractures following total hip arthroplasty are relatively uncommon but are associated with significant morbidity. With an increasing number of total hip arthroplasties being carried out in an aging population we need to ensure correct implants are chosen for our patients. A recent review of NJR data suggested a significantly higher revision risk for the Zimmer CPT stems due to
Introduction: The amount of tension which surgeons apply to a two-side Dall-Miles cable during the fixation of
Aim. Periprosthetic joint infection (PJI) and
Mortality following revision hip surgery for
Periprosthetic femoral fractures can occur as a complication of total hip arthroplasty and are often challenging to treat as the mechanical scenario is influenced by the presence of the metal prosthesis within the bone. This research focuses on finding the optimum fixation for transverse, Vancouver type B1
Introduction and Aims:
PURPOSE OF STUDY.
Purpose of the study: Few data are available concerning the proper management of patients with a
We present a case of multifocal infection involving the left total hip replacement and the right total knee replacement of a patient, further complicated by an infected non-union of a
Aim.
Post-operative
Introduction: The JRI Furlong HAC LOL hemiarthroplasty stem has shown increased
Dual mobility (DM) is most often used by surgeons to reduce instability in high risk patients. NJR data on DM has not demonstrated a reduction in all cause revision and has reported an increase in revision for peri-prosthetic fracture (PPF). The aim of our study was: Report outcome of DM used in high-risk patients including non-revision re-operations (dislocation & PPF). Comparison with conventional bearing THA (cTHA) with local, national and NJR benchmarking data. Retrospective cohort assessment of falls risk for patients receiving DM. Prospective F/U of a DM implant since 2016 and enrolled into Beyond Compliance (BC). Primary outcome measure all-cause revision with secondary outcome including any re-operation and Oxford Hip Score (OHS). All patients were risk stratified and considered high risk for instability. Complications were identified via hospital records, clinical coding linkage, NJR and BC. Benchmarking data for comparison was obtained from same data sources we also considered all B type PPF that occurred with cemented polished taper stem (PTS). 159 implants in 154 patients with a mean age 74.0 years and a maximum F/U of 6.7 years. Survivorship for all-cause revision 99.4% (95% CI 96.2–99.8). One femoral only revision. Mean gain in OHS 27.4. Dislocation rate 0.6% with a single event. Patients with a PTS rate of Type B PPF 2.1% requiring revision/fixation. Compared to cTHA this cohort was significantly older (74.0 vs 68.3 years), more co-morbidity (ASA 3 46.5% vs 14.4%) and more non-OA indications (32.4% vs 8.5%). Relative risks for dislocation 0.57 (95%CI 0.08–4.1) and PPF 1.75 (95%CI 0.54–5.72). Every patient had at least one risk factor for falling and >50% of cohort had 4 or more risk factors using NICE tool. The selective use of DM in high-risk patients can reduce the burden of instability. These individuals are very different to the “average” THA patient. A “perfect storm” is created using a high-risk implant combination (DM & PTS) in high-risk falls risk population. This re-enforces the need to consider all patient and implant factors when deciding bearing selection.