Use of anticoagulants for thromboembolic prophylaxis is strongly supported by evidence. However, the use of these medications beyond the prophylactic period is poorly understood. We identified anticoagulant naïve patients that underwent hip or knee replacement between 2012 and 2019 from an arthroplasty registry and probabilistically linked 3,018 surgeries with nationwide pharmaceutical claims data. Rates of anticoagulation use were examined during the early (<= 60 days post-discharge), mid-term (61–180 days post-discharge) and
Uncemented femoral components have been used in total hip arthroplasties (THAs) for over three decades. Data on
This study aimed to identify
The periacetabular osteotomy(PAO) is an effective common hip-preserving procedure to treat symptomatic acetabular dysplasia of the hip (DDH). The literature regarding truly
Abstract. Introduction. Patient selection is key to the success of medial unicondylar knee arthroplasty (UKA). Progression of arthritis is the most common indication for revision. Various methods of assessing the lateral compartment have been used including stress radiography, radioisotope bone scanning, MRI, and visualisation at the time of surgery. Arthroscopy is another means of assessing the integrity of the lateral compartment. Methods. We used per-operative arthroscopy as a means to confirm suitability for UKA in a consecutive series of 279 Oxford medial UKA. This study reports the
Aim. Antimicrobial suppression has shown to significantly improve treatment success of streptococcal periprosthetic joint infection (PJI) compared to 12-week standard antimicrobial therapy, however, only short-term follow-up was investigated. In this study we assessed the impact of suppression on the
Background. Iatrogenic hallux varus is a rare complication after hallux valgus surgery. Operative treatment comprises a wide variety of techniques, of which the reversed transfer of the abductor hallucis tendon is the most recent described technique. Methods. This paper will present the
The purpose of this study was to determine
Osteoarthritis (OA) of the hip is the most common indication for total hip replacement (THR). Obesity is a risk factor for the development of OA and has recently resulted in patients requiring THRs at much younger ages to relieve pain at the joint capsule and restore mobility. However, the impact of obesity on THR mortality is not well understood. An updated systematic review was performed to identify whether an obese BMI should influence patient selection for surgery. Specifically, the impact of obesity on short-term mortality,
We previously reported the five to ten-year results of the Birmingham Hip Resurfacing (BHR) implant. The purpose of this study was to evaluate the survivorship, radiographic results, and clinical outcomes of the BHR at
To compare the
Abstract. Background. To determine the
Aim. Fracture-related infection (FRI) is a severe post-traumatic complication which can be accompanied with a soft-tissue defect or an avital soft-tissue envelope. In these cases, a thoroughly planned orthoplastic approach is imperative since a vital soft-tissue envelope is mandatory to achieve fracture union and infection eradication. The aim of our study was to analyse plastic surgical aspects in the management of FRIs, including the type and outcome of soft-tissue reconstruction (STR), and to investigate the
The aim of this study was to evaluate the
Introduction. Vascularized fibular grafting following tumor resection is an essential treatment option in limb salvage surgery. This study aimed to assess the surgical and oncological outcomes of patients treated in Denmark between 2010 and 2022. Method. We present a retrospective review of a national cohort comprising 27 patients. The indications were 13 cases of Ewing sarcoma, 12 cases of osteosarcoma, and 2 cases of giant cell tumor. The median age at surgery was 16 years (range: 2-39), and the median follow-up was 82 months (range: 12-138). Patients were analyzed overall and stratified into upper and lower extremity groups based on tumor location. Result. The primary rate of graft union was 63%, and after secondary procedures, the overall rate of graft union was 67%, with a median time to union of 13 months (range: 7-29). The reoperation rate was 74%, while the rate of limb salvage was 93%, with two patients undergoing amputation during follow-up. The 5-year overall survival rate was 81% (95% CI: 61-92). Patients with upper extremity tumors were more likely to attain graft union (92% vs. 47%, p=0.02) and less likely to undergo multiple reoperations (17% vs 60%, p=0.047) compared to patients with lower extremity tumors. Conclusion. Vascularized fibula grafting remains a valuable option in limb salvage surgery with acceptable
The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Aim of this study was to investigate long term results of a new RH prosthesis (EnduRo®, B Braun, Germany), which uses carbon-fiber reinforced poly-ether-ether-ketone (CFR PEEK) as a new bearing material, first time used in knee arthroplasty. Fifty-six consecutive patients, who received the EnduRo® RH prosthesis were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively as well as postoperatively after 3 and 12 months and annually thereafter. Min. Follow up was 7 and mean follow up 9,3 years. Clinical examination included Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), and range of motion (ROM). Competing risk analysis was assessed for survival with respect to indication and failure mode. KSS, WOMAC, OKS, and ROM significantly improved from the preoperative to the follow up investigations (p < 0.0001). There was no difference in clinical outcome between the primary and the revision group. The overall cumulative incidence for revision for any reason was 23.6% and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002). The evaluated RH prosthesis provided reliable and durable results with a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of cases. The use of this RH system in primary patients showed high survival rates.
Introduction. It has been contentious whether an anatomic double-bundle technique for anterior cruciate ligament reconstruction (ACLR)is superior to that of a single-bundle technique. It has been hypothesized in the literature that the double-bundle technique could provide function closer to that of the anatomical knee joint. The purpose of this study was to compare the
The Accolade®TMZF is a taper-wedge cementless metaphyseal coated femoral stem widely utilized from 2002-2012. In recent years, there have been reports of early catastrophic failure of this implant. Establishing a deeper understanding of the rate and causes of revision in patients who developed aseptic failure in stems with documented concerns about high failure rates is critical. Understanding any potential patient or implant factors which are risk factors for failure is important to inform both clinicians and patients. We propose a study to establish the
With the introduction of highly crosslinked polyethylene (HXLPE) in total hip arthroplasty (THA), orthopaedic surgeons have moved towards using larger femoral heads at the cost of thinner liners to decrease the risk of instability. Several short and mid-term studies have shown minimal liner wear with the use HXLPE liners, but the safety of using thinner HXPLE liners to maximize femoral head size remains uncertain and concerns that this may lead to premature failure exist. Our objective was to analyze the outcomes for primary THA done with HXLPE liners in patients who have a 36-mm head or larger and a cup of 52-mm or smaller, with a minimum of 10-year follow-up. Additionally, linear and volumetric wear rates of the HXLPE were evaluated in those with a minimum of seven-year follow-up. We hypothesized that there would be minimal wear and good clinical outcome. Between 2000 and 2010, we retrospectively identified 55 patients that underwent a primary THA performed in a high-volume single tertiary referral center using HXLPE liners with 36-mm or larger heads in cups with an outer diameter of or 52-mm or smaller. Patient characteristics, implant details including liner thickness, death, complications, and all cause revisions were recorded. Patients that had a minimum radiographic follow-up of seven years were assessed radiographically for linear and volumetric wear. Wear was calculated using ROMAN, a validated open-source software by two independent researchers on anteroposterior X-rays of the pelvis. A total of 55 patients were identified and included, with a mean age of 74.8 (range 38.67 - 95.9) years and a mean BMI of 28.98 (range 18.87 - 63-68). Fifty-one (94.4%) of patients were female. Twenty-six (47.7%) patients died during the follow-up period. Three patients were revised, none for liner wear, fracture or dissociation. Twenty-two patients had a radiographic follow-up of minimum seven years (mean 9.9 years, min-max 7.5 –13.7) and were included in the
Background. Studies have compared open reduction internal fixation (ORIF) with fibular nail fixation (FNF) and shown reduced wound complications with minimal difference to PROMS in the short term. Our aim is to compare