Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Applied filters
The Bone & Joint Journal

Include Proceedings
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 508 - 512
1 Apr 2010
Pearse AJ Hooper GJ Rothwell A Frampton C

We reviewed the rate of revision of unicompartmental knee replacements (UKR) from the New Zealand Joint Registry between 1999 and 2008. There were 4284 UKRs, of which 236 required revision, 205 to a total knee replacement (U2T) and 31 to a further unicompartmental knee replacement (U2U). We used these data to establish whether the survival and functional outcome for revised UKRs were comparable with those of primary total knee replacement (TKR). The rate of revision for the U2T cohort was four times higher than that for a primary TKR (1.97 vs 0.48; p < 0.05). The mean Oxford Knee Score was also significantly worse in the U2T group than that of the primary TKR group (30.02 vs 37.16; p < 0.01). The rate of revision for conversion of a failed UKR to a further UKR (U2U cohort) was 13 times higher than that for a primary TKR.

The poor outcome of a UKR converted to a primary TKR compared with a primary TKR should contra-indicate the use of a UKR as a more conservative procedure in the younger patient.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 58 - 63
1 Jan 2009
Hooper G Rothwell A Frampton C

We have examined the outcome of 400 consecutive patients who underwent total knee replacement with the Low Contact Stress mobile-bearing system between 1993 and 1994 and were followed up for a minimum of ten years. All operations were performed by surgeons in Christchurch, New Zealand, who used no other knee prosthesis during the study time.

At ten years after operation 238 patients (244 knees) remained for independent clinical and radiological assessment. There was a significant improvement (p < 0.001) in the postoperative knee scores at one, three, seven and ten years, although a slight deterioration in the score occurred between seven and ten years which did not reach statistical significance. The survival for polyethylene wear or loosening was 97% (95% CI 96 to 98) and survival using reoperation for any cause was 92% (95% CI 90 to 94) at 12 years. Polyethylene wear was more common in the meniscal-bearing component, with five knees requiring revision and a further eight demonstrating early wear. Osteolysis was not seen in the rotating platform component, but was present in three of the meniscal-bearing knees.

There was no association between the radiological alignment at one year and those knees that subsequently required revision. However, there was an association between the overall limb alignment and the Western Ontario McMasters University score (p < 0.001).

The Low Contact Stress mobile-bearing total knee replacement has proved to be a reliable implant at ten years when used in primary knee replacement irrespective of the deformity and diagnosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 873 - 879
1 Nov 1992
Mohammed K Rothwell A Sinclair S Willems S Bean A

We reviewed the results of reconstruction of 97 upper limbs in a consecutive series of 57 tetraplegic patients, treated from 1982 to 1990. Of these, 49 had functional and eight had cosmetic reconstructions. The principal functional objectives were to provide active elbow extension, hook grip, and key pinch. Elbow extension was provided in 34 limbs, using deltoid-to-triceps transfer. Hook grip was provided in 58 limbs, mostly using extensor carpi radialis longus to flexor pollicis longus transfer, and key pinch in 68, mostly using brachioradialis to flexor pollicis longus transfer. Many other procedures were employed. At an average follow-up of 37 months, 70% had good or excellent subjective results, and objective measurements of function compared favourably with other series. Revisions were required for 11 active transfers and three tenodeses, while complications included rupture of anastomoses and problems with thumb interphalangeal joint stabilisation and wound healing. We report a reliable clinical method for differentiating between the activity of extensor carpi radialis longus and brevis and describe a successful new split flexor pollicis longus tenodesis for stabilising the thumb interphalangeal joint. Bilateral simultaneous surgery gave generally better results than did unilateral surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 1 | Pages 12 - 16
1 Feb 1982
Rothwell A

From a series of 190 consecutive fractures of the shaft of the femur treated by closed Kuntscher nailing, 32 of the more severely comminuted have been studied to determine whether treatment by closed nailing was justified. Radiological criteria were used to divide them into 19 who were moderately comminuted and 13 grossly so. Twenty-four patients were less than 21 years of age and 19 patients had 40 significant associated injuries. Fifteen fractures were nailed on the day of injury, and complications were few. Nineteen patients had a supplementary cast-brace and all those who had been employed returned to work. Twelve patients had shortening of up to two centimetres and two had three centimetres; four had mild rotational deformities; seven had mild restriction of knee flexion; and two had delayed union. There were no infections. The advantages of this technique include a negligible risk of infection and rapid stabilisation of even grossly comminuted fractures, thus facilitating management of other injuries. The 44 per cent incidence of shortening is counterbalanced by early mobilisation and rapid return of knee function. It is concluded that when proper equipment and expertise are available then closed nailing is the treatment of choice for severely comminuted fractures of the femoral shaft.


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 504 - 509
1 Nov 1978
Rothwell A Fitzpatrick C

One hundred and two fractures of the femoral shaft, including eighteen pathological fractures, in 100 patients were internally fixed by closed Kuntscher nailing. Sixty-eight fractures resulted from motor vehicle accidents; ten were compound. Seventy-five patients were under the age of thirty years and thirty-four had multiple injuries. Sixty-nine fractures were nailed on the day of the accident and the operative technique is described. Complications during and after operations were few. Fifty-eight patients left hospital within four weeks and 77% of those working returned to work in less than four months. There were no wound or bone infections. The results are discussed and it is concluded that, with the correct equipment and careful attention to detail, closed nailing is a straightforward procedure with few complications. Advantages include the wide range of fractures that can be nailed, the short hospitalisation, the rapid return of function to the knee, the early return to work and the absence of infection.