Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
The Bone & Joint Journal

Include Proceedings
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 284 - 287
1 Mar 1998
Giurea A Paternostro T Heinz-Peer G Kaider A Gottsauner-Wolf F

We compared two methods of reconstruction of the abductor mechanism in 15 patients after prosthetic replacement of the upper femur, to assess abductor strength and function.

Six patients in group I had direct fixation of the gluteus medius tendon and a segment of the original bone to the prosthesis. Nine patients in group 2 had the abductor tendon fixed to the iliotibial band. We assessed clinical function, isometric muscle strength and muscle cross-sectional area for each patient.

The patients in group 1 had better clinical and functional results (p = 0.059), with average peak torques for hip abduction of 92% of that in the non-operated leg in group 1, and of 57% in group 2. Group 1 had a mean muscle cross-sectional area of 69% and a mean value of strength per cross-sectional area of 134% when compared with the control side. The respective values for group 2 were 52% and 91%.

Direct fixation of the abductor muscles to the prostheses gave improved function and higher isometric abductor muscle force.