Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
The Bone & Joint Journal

Include Proceedings
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 479 - 483
1 Apr 2011
Chang C Lai K Yang C Lan S

Between April 2004 and July 2007, we performed 241 primary total knee replacements in 204 patients using the e.motion posterior cruciate-retaining, multidirectional mobile-bearing prosthesis. Of these, 100 were carried out using an image-free navigation system, and the remaining 141 with the conventional technique. We conducted a retrospective study from the prospectively collected data of these patients to assess the early results of this new mobile-bearing design.

At a mean follow-up of 49 months (32 to 71), 18 knees (7.5%) had mechanical complications of which 13 required revision. Three of these had a peri-prosthetic fracture, and were removed from the study. The indication for revision in the remaining ten was loosening of the femoral component in two, tibiofemoral dislocation in three, disassociation of the polyethylene liner in four, and a broken polyethyene liner in one. There were eight further mechanically unstable knees which presented with recurrent disassociation of the polyethylene liner. There was no significant difference in the incidence of mechanical instability between the navigation-assisted procedures (8 of 99, 8.1%) and the conventionally implanted knees (10 of 139, 7.2%).

In our view, the relatively high rate of mechanical complications and revision within 30 months precludes the further use of new design of knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1145 - 1149
1 Nov 2002
Lai K Lin C Chen J

Distraction osteogenesis (callotasis) has been widely used in patients with limb-length inequality or massive bone defects. This procedure, however, may be associated with a high incidence of physical and psychosocial complications. Callotasis telescoping on a locked intramedullary nail has been used to shorten the period of external fixation. Little attention has been given to the use of locked intramedullary nails in the treatment of complications after callotasis.

Between 1990 and 1999, we used locked intramedullary nailing in 27 patients for the treatment of complications after distraction osteogenesis. There were 17 men and ten women with a mean age of 33.2 years (16 to 66). The nail was inserted at a mean of 3.4 weeks (0 to 15) after removal of the external fixator. Simultaneous autogenous bone grafting and soft-tissue reconstruction were also undertaken in seven and two patients, respectively.

There was consolidation of the callus or docking site in all patients at a mean of 6.4 months (2 to 14) after surgery. The mean shortening of the callus was 0.7 cm (0 to 2.5). Two patients had infection at the site of a distal screw which resolved after removal of the nail. In 17 patients the nail was removed at a mean of 26 months after its insertion.

Locked intramedullary nails are useful in treating complications after distraction osteogenesis in skeletally mature patients. The risk of infection should be borne in mind.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 641 - 646
1 Jul 2002
Lai K Shen W Chen C Yang C Hu W Chang G

Between March 1990 and May 1991 we performed 85 primary total hip replacements in 74 patients using the Landos Atoll hydroxyapatite (HA)-coated cup and the Corail HA-coated stem. The patients were followed up for a mean of ten years. Of the 85 cups, 26 (31%) have already been revised and a further six are radiologically unstable and awaiting revision. Two femoral stems have been revised for infection without loosening.

The retrieved acetabular cups were studied by SEM and image-processing techniques to quantify the amount of residual HA on the cup. This was correlated with the clinical variables and modes of failure. The residual HA (as a percentage of the surface) on the loose cups correlated negatively with the duration of implantation (r = −0.732, p < 0.001). Six cups were stable at revision and had more residual HA coating than those which were loose (p < 0.01).

The rate of failure of the Landos Atoll HA-coated, smooth hemispherical cup with screw fixation is unacceptably high. Resorption of the HA coating is markedly increased in loose cups compared with stable cups. HA coating cannot substitute for stable mechanical fixation.