Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
Applied filters
The Bone & Joint Journal

Include Proceedings
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 139 - 139
1 Jan 2006
Hamblen D


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 1 - 1
1 Jan 2004
Thomas N Hamblen D


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 157 - 159
1 Mar 2002
Horan F Adams JC Hamblen D Wilson JN


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1208 - 1209
1 Nov 2000
Hamblen D


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 753 - 753
1 Sep 1999
HAMBLEN D HORAN F


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 941 - 943
1 Nov 1998
Grigoris P Hamblen D


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 725 - 727
1 Sep 1994
James P Butcher I Gardner E Hamblen D

We investigated the incidence of cephalosporin-resistant bacteria in infected hip arthroplasties. Of 740 patients having hip replacement or related procedures performed over three years, 30 had positive bacteriological cultures from tissue removed at the time of surgery. In 18 of the 30 cultures Staphylococcus epidermidis was grown and 12 of these were methicillin-resistant. A prospective study of skin swabs taken from 100 consecutive patients at the time of admission for THR showed methicillin-resistant Staphylococcus epidermidis in 25. This cephalosporin-resistant organism was shown to be the commonest proven cause of infection, and its presence as a skin commensal raises important questions about current antibiotic prophylaxis for joint replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 521 - 523
1 Aug 1988
Hamblen D Paul J


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 470 - 472
1 May 1987
Hughes A Sherlock D Hamblen D Reid R

We report a case of malignant fibrous histiocytoma of the hip which occurred 30 years after the insertion of a single chrome-cobalt alloy screw for a slipped femoral epiphysis. The possible aetiological association between malignant tumours and metallic implants is discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 8 - 12
1 Jan 1987
Zoma A Sturrock R Fisher W Freeman P Hamblen D

We have reviewed 32 patients with rheumatoid disease of the cervical spine who underwent a total of 40 operations aimed at correcting instability and improving any associated neurovascular deficit. Apart from four patients with intractable pain, the main indication for surgery was progressive neurological impairment. Of the 32 primary operations, 19 (60%) were successful; the remainder failed to achieve their objective and there were two deaths in the immediate postoperative period. Of eight secondary operations performed for recurrence of symptoms or failure to relieve cervical myelopathy, only four were successful. Of nine operations for bony decompression to relieve cord compression from irreducible subluxation, only four were successful. The overall results show a success rate of 57% and a failure rate of 35% with early operative mortality in 8%. Indications for operation are discussed and earlier diagnosis is considered to be the key to improved results.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 689 - 690
1 Nov 1985
Hamblen D


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 625 - 627
1 Nov 1984
Hamblen D Carter R


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 502 - 506
1 Aug 1983
Whyte W Bailey P Hamblen D Fisher W Kelly I

A comparison was made in a laminar-flow operating room between total-body exhaust gowns and a clothing system made from Fabric 450. This disposable clothing was found to be much more comfortable and convenient than the total-body exhaust gowns. The average airborne bacterial counts obtained during total hip replacement operations from each of the clothing systems were identical when the downflow method of ventilation was used (0.7 per cubic metre) and no significant difference could be demonstrated when the crossflow system was used (2.2 per cubic metre with the total-body exhaust gowns and 3.1 per cubic metre with the disposable clothing). Tests in a dispersal chamber were carried out to find the effectiveness of each item of the disposable clothing in reducing bacterial dispersion. These tests demonstrated the relative ineffectiveness of wearing a surgical gown as compared with wearing the complete system. It was confirmed bacteriologically that the downflow system of ventilation was more efficient than the crossflow type; the importance of this observation with respect to clothing and sepsis is discussed in this paper.