Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Applied filters
The Bone & Joint Journal

Include Proceedings
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 986 - 989
1 Jul 2005
McMurtry I Bennet GC Bradish C

We report 12 consecutive cases of vertical scapular osteotomy to correct Sprengel’s deformity, performed during a 16-year period, with a mean follow-up of 10.4 years. The mean increase in abduction of the shoulder was 53°. The cosmetic appearance improved by a mean of 1.5 levels on the Cavendish scale. Neither function nor cosmesis deteriorated with time. We recommend the procedure for correction of moderate deformities with a functional deficit.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 155 - 155
1 Jan 1993
Marshall J Bradish C


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 106 - 108
1 Jan 1988
Bradish C Davies S Malone M

We report five patients with tibia vara due to focal fibrocartilaginous dysplasia of the medial aspect of the proximal tibia. In three patients spontaneous correction occurred, while in one of the remaining two treated by operation, a valgus deformity and neurological complications resulted. Conservative management is therefore recommended.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 276 - 284
1 Mar 1987
Bradish C Kemp H Scales J Wilson J

We report the long-term clinical follow-up and survivorship analysis of 40 distal femoral replacements performed between 1964 and 1980 for traumatic, locally aggressive and malignant conditions. Custom-made prostheses with fully-constrained knee joints were used to replace a mean of 42% of the length of the femur. Survivorship analysis showed a cumulative success rate of 80% at eight years, with no subsequent deterioration at 18 years. Clinical assessment revealed 78% excellent or good results. Failure was due to infection in three cases, and in two to fracture of a now-outmoded femoral stem.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 1 | Pages 130 - 132
1 Jan 1985
Bradish C

Eight cases of carpal tunnel syndrome are reported, all of which developed in patients on haemodialysis for chronic renal failure. In each case the arm involved had been used for a fistula. The aetiology of the syndrome in these patients is discussed; it is multifactorial, but related to the sites of arteriovenous fistulae. Decompressing the carpal tunnel provides effective and lasting relief.