Advertisement for orthosearch.org.uk
Results 1 - 20 of 152
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 670 - 672
1 May 2006
Darmanis S Bircher M

We describe two patients aged 16 and 25 years with osteogenesis imperfecta who sustained displaced fractures of the acetabulum following minor trauma. The femoral heads were deformed by impact against the acetabular margin and both cases underwent surgical reconstruction. The quality of the bone and soft tissues made the operations challenging. There were potential complications specific to osteogenesis imperfecta, including bleeding, the creation of secondary fracture lines and shredding of the soft-tissue. The cases provide useful guidelines for addressing these difficulties


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 602 - 604
1 Aug 1985
Versfeld G Beighton P Katz K Solomon A

Study of 16 patients with Type III osteogenesis imperfecta showed marked elongation of the pedicles of the vertebrae in all cases, a deformity which was not seen in other types of the disease. Posterior rib angulation was also noted in Type III disease. These features have proved useful in suggesting the diagnosis of osteogenesis imperfecta even before long bones have fractured and in categorizing patients with osteogenesis imperfecta into the correct type for prognostic purposes


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 233 - 238
1 Mar 1984
Pozo J Crockard H Ransford A

Basilar impression is a well-recognised though rare complication of osteogenesis imperfecta. Three patients, all members of the same family, with advanced basilar impression complicating osteogenesis imperfecta tarda, are described. The clinical features in these cases illustrate the natural history of this condition: from asymptomatic ventricular dilatation, through the foramen magnum compression syndrome, to death from brain-stem compression. The radiological criteria on which the diagnosis is based, are defined. Review of the literature reveals only seven previously documented cases, all in patients with mild forms of osteogenesis imperfecta. The unusually low incidence of basilar impression in osteogenesis imperfecta and its apparent restriction to patients with mild forms of the disease is discussed. The examination of close relatives of patients with basilar impression and osteogenesis imperfecta is emphasised in order to anticipate the onset of severe neurological complications


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 812 - 814
1 Jun 2009
Ramaswamy R Kosashvili Y Cameron H

Osteogenesis imperfecta is a rare inherited disorder of connective tissue which may present with recurrent fractures which are prone to nonunion and malunion resulting in deformity. Some patients develop osteoarthritis of the hip. Formation of hyperplastic callus after recurrent fractures may deform the shape of the femur and preclude the use of standard implants at joint replacement. Replacement can thus be technically demanding. We present a case of bilateral hip replacement in a patient with osteogenesis imperfecta and hyperplastic callus which was treated by the use of long femoral allografts and cemented femoral stems


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 634 - 638
1 May 2011
Cho T Kim J Lee JW Lee K Park MS Yoo WJ Chung CY Choi IH

We investigated the fracture-free survival of long bones stabilised by a telescopic intramedullary rod (TIMR) in patients with osteogenesis imperfecta with respect to the remodelling status of fracture or osteotomy sites and TIMR regions, in order to identify risk factors for fracture. A total of 44 femora and 28 tibiae in 25 patients with a mean age of 5.0 years (1.9 to 10.5) at presentation were studied. There were six patients with Sillence type I, five with type III, 13 with type IV and one with type V osteogenesis imperfecta. All received bisphosphonate treatment at the same stage during the mean follow-up of 7.3 years (0.5 to 18.1). The fracture-free survival was estimated at 6.2 years (95% confidence interval 5.1 to 7.3) by Kaplan-Meier analysis. More than half the fracture or osteotomy sites remained in a less-remodelled state at the latest follow-up or time of fracture. Of the 33 fractures, 29 (87.9%) occurred in long bones containing a less-remodelled site, and these fractures were located at this site. The relative fracture risk at the rod tip was significantly greater than in any other TIMR region (p < 0.001), and this was higher in bone segments having a less-remodelled site. This study shows a persistent fracture risk in TIMR-stabilised long bones, especially at less-remodelled fracture or osteotomy sites and at the rod tip


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 422 - 427
1 May 1989
Stockley I Bell M Sharrard W

We report the results of using 83 expanding intramedullary rods in 24 children with osteogenesis imperfecta after a mean follow-up of five years three months. In all, 62% of the rods have expanded after one primary operation. Thirty-four additional operations were necessary; 11 for the correction of rotation or angulation deformities and 23 for revision of the rod or T-piece. All these revisions were successful. Complications were more frequent in children who required very small rods. Problems with Bailey-Dubow rods led to the development of the Sheffield rod system; 17 bones treated with these rods are included in the series. Before surgery only eight of the 24 children were able to walk but at review 20 children were walking, 15 without walking aids. Elongating intramedullary rods should be available to all children with osteogenesis imperfecta as they improve walking capability, reduce the number of fractures, prevent deformity and allow integration of the child into society


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 143 - 147
1 Jan 1995
Zionts L Nash J Rude R Ross T Stott N

We used dual-energy X-ray absorptiometry (DEXA) to compare the bone mineral density (BMD) of nine children aged from 2 years 7 months to 13 years 5 months who had mild osteogenesis imperfecta with an age- and sex-matched control group. The patients had only mild clinical symptoms but DEXA detected highly significant differences in BMD between them and the controls. The mean BMD in the children with osteogenesis imperfecta was 76.7% of normal in the lumbar spine (p < 0.001) and 71.2% of normal in the femoral neck (p < 0.001). DEXA is an objective, reproducible and sensitive method of measurement of BMD in children. It may help to establish the diagnosis, to assess prognosis and possibly to monitor the response to different types of treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 1 | Pages 36 - 43
1 Feb 1982
Yong-Hing K MacEwen G

A survey was conducted to document the results of bracing and spinal fusion for scoliosis associated with osteogenesis imperfecta. Observations were made of 121 patients who underwent treatment by bracing or spinal fusion and who had been treated by 51 orthopaedic surgeons in 14 countries. The average curve before bracing measured 43 degrees. The braces were ineffective in stopping progression even in small curves. We were unable to determine whether braces slowed the rate of progression of curvature. The average age at fusion was 15 years 7 months, the average curve before operation measured 74 degrees, and the average correction was 36 per cent. The high incidence of complications was related to the size of the curve before spinal fusion, the use of Harrington instrumentation, and the presence of associated kyphosis. In the absence of pseudarthrosis or kyphosis, late bending of the fused spine did not seem to occur


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 184 - 185
1 Mar 1983
Ziv I Rang M Hoffman H

Paraplegia occurred in an adolescent girl with osteogenesis imperfecta after chiropractic manipulation. The child had been able to walk freely out of doors. Complete motor paralysis with sensory sparing resulted due to anterior compression of the cord by spondyloptotic cervical vertebrae. Reconstructed computerised tomography was very helpful in demonstrating the abnormality. Anterior and then posterior decompression relieved the tethered spinal cord and were supplemented with bone grafting. Early diagnosis and surgical treatment will prevent similar neurological accidents


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 652 - 655
1 Nov 1984
Middleton R

Three cases of severe osteogenesis imperfecta are reported. Each was treated by closed intramedullary rodding, combined with osteoclasis to correct deformity. Operation was performed within a few months of birth. Both tibiae and both femora were stabilised in one operation, using x-ray image intensification to monitor placement of the rods. The technique used to insert the rods is described. The procedure appeared to be entirely satisfactory in reducing the incidence of fractures and it allowed the affected infants to be handled much more easily


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 54 - 55
1 Jan 1998
Karagkevrekis CB Ainscow DAP

We describe two patients with osteogenesis imperfecta who developed transient osteoporosis in both hips sequentially


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 475 - 479
1 May 1990
Sanguinetti C Greco F De Palma L Specchia N Falciglia F

We obtained specimens of growth-plate cartilage from four patients with osteogenesis imperfecta. Light microscopy showed structural changes in the tissue and morphological changes in chondrocytes and matrix, particularly in the hypertrophic zone. There were changes in the process of calcification in the primary mineralisation zone of the cartilage. We also found histochemical changes in the matrix glycosaminoglycans (GAGs) in the zones where physiological mineralisation was disturbed and where the trabeculae were interrupted and poorly mineralised. In addition to the known molecular defects in collagen, changes in GAGs and non-collagenous proteins are important factors in the pathogenesis of the disease


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 429 - 432
1 May 1987
Middleton R Frost R

This paper describes the design, development and early surgical experience with a stereotactic device to allow closed retrieval and interchange of intramedullary rods in children with osteogenesis imperfecta. This relatively atraumatic procedure may allow more frequent rod interchange than with other techniques, lessening the likelihood of deformity and fracture in the unsupported skeleton when the bone has outgrown the intramedullary rod. The procedure was developed by design studies in vitro followed by intramedullary rodding of tibiae of New Zealand white rabbits. It has been used in children 12 times, in six tibiae and six femora: 11 rods have been successfully retrieved, with rod interchange in eight of these cases


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 259 - 265
1 Mar 2004
Saldanha KAN Saleh M Bell MJ Fernandes JA

We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening. Angular deformities were corrected simultaneously. Five limb segments were treated using a monolateral external fixator and four with the Ilizarov frame. In three children, lengthening was done over previously inserted femoral intramedullary rods. The mean lengthening achieved was 6.26 cm (mean healing index, 33.25 days/cm). Significant complications included one deep infection, one fracture of the femur and one anterior angulation deformity of the tibia. The abnormal bone of OI tolerated the external fixators throughout the period of lengthening without any episodes of migration of wires or pins through the soft bone. The regenerate bone formed within the time which is normally expected in limb-lengthening procedures performed for other conditions. We conclude that despite the abnormal bone characteristics, distraction osteogenesis to correct limb-length discrepancy and angular deformity can be performed safely in children with OI


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 2 | Pages 189 - 196
1 May 1977
Nade S Burwell R

This paper examines the fate of decalcified allografts (homografts) of iliac cancellous bone impregnated with autologous red marrow and implanted intermuscularly into the anterior abdominal wall of rabbits. In contrast to the findings of Urist and other workers that cortical bone decalcified with hydrochloric acid (HCl) and then freeze-dried is inductive to new bone formation in various heterotopic sites, evidence is presented that iliac bone decalcified by HCl and grafted alone to a muscular site is itself very weakly inductive to bone formation. However, when combined with autologous bone marrow the HCl-decalcified bone provides a better substrate for bone formation by marrow cells than does either undecalcified iliac bone, or iliac bone decalcified with ethylene-diamine-tetra-acetic acid. The freezing or freeze-drying of decalcified bone does not affect new bone formation when implanted alone or with autologous marrow. The differences between the cortical and cancellous bone as inductive substrates for osteogenesis are discussed and the interrelationship of bone and marrow in combined bone grafts are re-evaluated


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 999 - 1004
1 Nov 1998
Wilkinson JM Scott BW Clarke AM Bell MJ

The Sheffield Expanding Intramedullary Rod System was developed after experiencing problems with existing rod systems in the management of osteogenesis imperfecta. Between 1986 and 1996 we treated 74 bones in the lower limb in 28 children at a median follow-up of 5.25 years. We have reviewed 24 children with a total of 60 rods. Before surgery, all children had had multiple fractures of the lower limb. At review eight patients had experienced no further fractures, but three had suffered five or more subsequently. Before initial stabilisation, 15 children had never walked, and only three (13%) used walking as their main means of mobility. After surgery, half of those who showed motor arrest were able to walk (p = 0.016). The number of patients able to walk, with or without aids, increased to 17 (p = 0.0001). We have experienced no evidence of epiphyseal damage after the procedure, and complication rates requiring rod exchange have been low (7%)


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 227 - 232
1 Mar 1984
Lang-Stevenson A Sharrard W

The results and complications of the use of Bailey-Dubow extensible rods in 28 lower limb bones of 10 patients suffering from osteogenesis imperfecta are reviewed. Twenty-eight operations were for the primary insertion of the rods into the femur or tibia; a further nine operations were needed for the treatment of complications. These complications included 10 instances of proximal migration of the distal end of the rod, one of incorrect placement in the proximal femur, four instances of loosening of a T-piece and three of infection about a rod, two of these being in one child. Most complications arose from technical faults at insertion. The details of technique which have evolved from experience are described. Only one fracture has occurred in a bone after correct placement of a rod. Of the 10 patients, seven of whom had never walked before, seven were able to walk and two others had achieved walking, but were under treatment for complications at the time of review. There was no evidence of damage to growth epiphyses. The greater technical complexity of insertion of Bailey-Dubow rods is well justified by the results obtained when they are correctly applied


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 11 - 16
1 Jan 2000
Li YH Chow W Leong JCY

We have reviewed the results of the Sofield-Millar operation on 58 long bones in ten patients. If more than three osteotomies were undertaken the time to union of the bone was significantly prolonged (p< 0.001) with significant thinning of the bone (p< 0.02).

We have used a modified technique in order to minimise surgical trauma and devascularisation of the bone. The rod is introduced under the control of an image-intensifier. Small surgical exposures are made only at the sites of corrective wedge osteotomies. The number of osteotomies is kept to the minimum.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 88 - 96
1 Jan 2023
Vogt B Rupp C Gosheger G Eveslage M Laufer A Toporowski G Roedl R Frommer A

Aims

Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences.

Methods

A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 155 - 156
1 Jan 1995
Ogilvie-Harris D Khazim R