Advertisement for orthosearch.org.uk
Results 1 - 20 of 341
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1200 - 1209
14 Sep 2020
Miyamura S Lans J He JJ Murase T Jupiter JB Chen NC

Aims. We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. Methods. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves. Results. In the nonunion group, both the distal (100.2%) and proximal (126.6%) fragments had a significantly higher bone density compared to the union (distal: 85.7%; proximal: 108.3%) or control groups (distal: 91.6%; proximal: 109.1%) using the 3D bone density measurement, which were statistically significant for all comparisons. 2D measurements were highly correlated to 3D bone density measurements (Spearman’s correlation coefficient (R) = 0.85 to 0.95). Using 2D measurements, ROC curve analysis revealed the optimal cutoffs of 90.8% and 116.3% for distal and proximal fragments. This led to a sensitivity of 1.00 if either cutoff is met and a specificity of 0.82 when both cutoffs are met. Conclusion. Using 3D modelling software, nonunions were found to exhibit bone density increases in both the distal and proximal fragments in CTs performed between four to 18 weeks after fracture during the course of treatment. 2D bone density measurements using standard CT scans correlate well with 3D models. In patients with scaphoid fractures, CT bone density measurements may be useful in predicting the likelihood of nonunion. Cite this article: Bone Joint J 2020;102-B(9):1200–1209


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 467 - 471
1 Apr 2006
Leichtle UG Leichtle CI Schmidt B Martini F

Peri-prosthetic bone loss caused by stress shielding may be associated with aseptic loosening of femoral components. In order to increase primary stability and to reduce stress shielding, a three-dimensional, cementless individual femoral (Evolution K) component was manufactured using pre-operative CT scans. Using dual energy x-ray absorptiometry, peri-prosthetic bone density was measured in 43 patients, three months, six months, 3.6 and 4.6 years after surgery. At final follow-up there was a significant reduction in mean bone density in the proximal Gruen zones of −30.3% (zone 7) and −22.8% (zone 1). The density in the other zones declined by a mean of between −4% and −16%. We conclude that the manufacture of a three-dimensional, custom-made femoral component could not prevent a reduction in peri-prosthetic bone density


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1503 - 1509
1 Nov 2014
Ritter MA Davis KE Small SR Merchun JG Farris A

The relationship between post-operative bone density and subsequent failure of total knee replacement (TKR) is not known. This retrospective study aimed to determine the relationship between bone density and failure, both overall and according to failure mechanism. All 54 aseptic failures occurring in 50 patients from 7760 consecutive primary cemented TKRs between 1983 and 2004 were matched with non-failing TKRs, and 47 failures in 44 patients involved tibial failures with the matching characteristics of age (65.1 for failed and 69.8 for non-failed), gender (70.2% female), diagnosis (93.6% OA), date of operation, bilaterality, pre-operative alignment (0.4 and 0.3 respectively), and body mass index (30.2 and 30.0 respectively). In each case, the density of bone beneath the tibial component was assessed at each follow-up interval using standardised, calibrated radiographs. Failing knees were compared with controls both overall and, as a subgroup analysis, by failure mechanism. Knees were compared with controls using univariable linear regression. Significant and continuous elevation in tibial density was found in knees that eventually failed by medial collapse (p < 0.001) and progressive radiolucency (p < 0.001) compared with controls, particularly in the medial region of the tibia. Knees failing due to ligamentous instability demonstrated an initial decline in density (p = 0.0152) followed by a non-decreasing density over time (p = 0.034 for equivalence). Non-failing knees reported a decline in density similar to that reported previously using dual-energy x-ray absorptiometry (DEXA). Differences between failing and non-failing knees were observable as early as two months following surgery. This tool may be used to identify patients at risk of failure following TKR, but more validation work is needed. Cite this article: Bone Joint J 2014;96-B:1503–9


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 407 - 411
1 May 1987
Seitz P Ruegsegger P Gschwend N Dubs L

Loosening is a serious problem in total arthroplasty and early detection of bone loss in the vicinity of an implant would help in its investigation. We present a method for the objective evaluation of bone adjacent to metallic implants in which a modified technique of quantitative computed tomography (QCT) is used to reconstruct cross-sectional images with few artefacts. We have used this technique in 19 patients with knee arthroplasties to monitor the changes in bone density around the tibial stem of the prosthesis. In the first weeks after operation all patients showed a decrease in bone density ranging from 0.4% to 3.6% per month. One year after arthroplasty bone density had stabilised and only minor changes were observed. Our work indicates that modified QCT is a sensitive method for the long-term monitoring of the anchorage of implants and allows the early detection of osteolytic changes


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 3 | Pages 349 - 351
1 Aug 1977
Specht E

A computerised image analyser has been used experimentally to determine its possible usefulness in quantifying bone density. Rats were prepared for this purpose and ash weight/volume readings were obtained on femora which had been radiographed and studied to estimate radiographic density by means of the image analyser. The findings indicated that rats can be prepared by administering oestradiol or by allowing an additional week's growth, both of which give a statistically significant increase of bone density. The computerised image analyser was able to detect these differences but the correlations, although real and linear, between ash weight/volume and radiographic density were not large. Further refinements in techniques will be needed before the system is applied clinically


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1033 - 1044
1 Aug 2011
Periasamy K Watson WS Mohammed A Murray H Walker B Patil S Meek RMD

The ideal acetabular component is characterised by reliable, long-term fixation with physiological loading of bone and a low rate of wear. Trabecular metal is a porous construct of tantalum which promotes bony ingrowth, has a modulus of elasticity similar to that of cancellous bone, and should be an excellent material for fixation. Between 2004 and 2006, 55 patients were randomised to receive either a cemented polyethylene or a monobloc trabecular metal acetabular component with a polyethylene articular surface. We measured the peri-prosthetic bone density around the acetabular components for up to two years using dual-energy x-ray absorptiometry. We found evidence that the cemented acetabular component loaded the acetabular bone centromedially whereas the trabecular metal monobloc loaded the lateral rim and behaved like a hemispherical rigid metal component with regard to loading of the acetabular bone. We suspect that this was due to the peripheral titanium rim used for the mechanism of insertion


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1429 - 1430
1 Nov 2014
Wilton TJ


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 606 - 613
1 May 2006
Abu-Rajab RB Watson WS Walker B Roberts J Gallacher SJ Meek RMD

We compared peri-prosthetic bone mineral density between identical cemented and cementless LCS rotating platform total knee arthroplasties. Two matched cohorts had dual energy x-ray absorptiometry scans two years post-operatively using a modified validated densitometric analysis protocol, to assess peri-prosthetic bone mineral density. The knee that was not operated on was also scanned to enable the calculation of a relative bone mineral density difference. Oxford Knee and American Knee Society scores were comparable in the two cohorts. Statistical analysis revealed no significant difference in absolute, or relative peri-prosthetic bone mineral density with respect to the method of fixation. However, the femoral peri-prosthetic bone mineral density and relative bone mineral density difference were significantly decreased, irrespective of the method of fixation, particularly in the anterior distal portion of the femur, with a mean reduction in relative bone mineral density difference of 27%. There was no difference in clinical outcome between the cemented and cementless LCS total knee arthroplasty. However, both produce stress-shielding around the femoral implants. This leads us to question the use of more expensive cementless total knee components


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 2 | Pages 257 - 260
1 May 1954
Adam A Ritchie D

A case of parathyroid adenoma in a growing girl is described in which radiographs showed bands of increased density in the metaphyses in addition to the usual signs of osteitis fibrosa cystica. The literature is reviewed and the appearances are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1438 - 1440
1 Nov 2006
Niimi R Sudo A Hasegawa M Fukuda A Uchida A

Transient osteoporosis of the hip is a disorder characterised by pain, and associated with temporary osteopaenia. Although osteopaenia is the essence of the condition, data do not exist about the local bone density of the femoral neck if no medication is administered. We describe three patients who were treated with limitation of weight-bearing only. Repeated bone mineral density measurements were obtained, and that at the femoral neck was lowest two months after the onset of the condition. The mean reduction in bone mineral density when compared with an age-matched control group was 13% (3% to 24%). Spontaneous recovery was observed in all patients


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 914 - 917
1 Nov 1993
Janes G Collopy D Price R Sikorski J

We used dual-energy X-ray absorptiometry (DEXA) to measure the bone mineral content (BMC) of both tibiae in 13 patients who had been treated for a tibial fracture by rigid plate fixation. Within two weeks of plate removal the BMC was significantly greater in the bone that had been under the plate than at the same site in the control tibia. An unplated area of bone near the ankle showed a significant decrease in BMC at the time of plate removal with subsequent return to the level of the control tibia during the ensuing 18 months. We conclude that osteoinductive influences outweigh the potential causes of osteopenia, such as stress shielding and disuse, and that, contrary to expectation, demineralisation is not a factor in the diminished strength of the tibia after plating for fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1648 - 1653
1 Dec 2010
Cordingley R Kohan L Ben-Nissan B

The major advantage of hip resurfacing is the decreased amount of bone resection compared with a standard total hip replacement. Fracture of the femoral neck is the most common early complication and poor bone quality is a major risk factor. We undertook a prospective consecutive case control study examining the effect of bone mineral density changes in patients undergoing hip resurfacing surgery. A total of 423 patients were recruited with a mean age of 54 years (24 to 87). Recruitment for this study was dependent on pre-operative bilateral femoral bone mineral density results not being osteoporotic. The operated and non-operated hips were assessed. Bone mineral density studies were repeated over a two-year period. The results showed no significant deterioration in the bone mineral density in the superolateral region in the femoral neck, during that period. These findings were in the presence of a markedly increased level of physical activity, as measured by the short-form 36 health survey physical function score


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 548 - 554
1 Jun 2024
Ohyama Y Minoda Y Masuda S Sugama R Ohta Y Nakamura H

Aims. The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group). Methods. The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded. Results. There were significantly larger contact areas in Gruen zones 3, 5, and 6 in the N-HA group than in the T-HA group. At two years postoperatively, there was a significant decrease in BMD around the proximal-medial femur (zone 6) in the N-HA group and a significant increase in the T-HA group. BMD changes in both groups correlated with BMI or preoperative lumbar BMD rather than with the extent of contact with the femoral cortical bone. Conclusion. The N-HA-coated stem showed a significantly larger contact area, indicating a distal fixation pattern, compared with the traditional fully HA-coated stem. The T-HA-coated stem showed better preservation of periprosthetic BMD, two years postoperatively. Surgeons should consider these patterns of fixation and differences in BMD when selecting fully HA-coated stems for THA, to improve the long-term outcomes. Cite this article: Bone Joint J 2024;106-B(6):548–554


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 772 - 775
1 Jun 2009
Wilson J Bonner TJ Head M Fordham J Brealey S Rangan A

Low-energy fractures of the proximal humerus indicate osteoporosis and it is important to direct treatment to this group of patients who are at high risk of further fracture. Data were prospectively collected from 79 patients (11 men, 68 women) with a mean age of 69 years (55 to 86) with fractures of the proximal humerus in order to determine if current guidelines on the measurement of the bone mineral density at the hip and lumbar spine were adequate to stratify the risk and to guide the treatment of osteoporosis. Bone mineral density measurements were made by dual-energy x-ray absorptiometry at the proximal femur, lumbar spine (L2-4) and contralateral distal radius, and the T-scores were generated for comparison. Data were also collected on the use of steroids, smoking, the use of alcohol, hand dominance and comorbidity. The mean T-score for the distal radius was −2.97 (. sd. 1.56) compared with −1.61 (. sd. 1.62) for the lumbar spine and −1.78 (. sd. 1.33) for the femur. There was a significant difference between the mean lumbar and radial T scores (1.36 (1.03 to 1.68); p < 0.001) and between the mean femoral and radial T-scores (1.18 (0.92 to 1.44); p < 0.001). The inclusion of all three sites in the determination of the T-score increased the sensitivity to 66% compared with that of 46% when only the proximal femur and lumbar spine were used. This difference between measurements in the upper limb compared with the axial skeleton and lower limb suggests that basing risk assessment and treatment on only the bone mineral density taken at the hip or lumbar spine may misrepresent the extent of osteoporosis in the upper limb and the subsequent risk of fracture at this site. The assessment of osteoporosis must include measurement of the bone mineral density at the distal radius to avoid underestimation of osteoporosis in the upper limb


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1118 - 1122
1 Aug 2010
Lee JS Suh KT Eun IS

Low bone mass and osteopenia have been described in the axial and peripheral skeleton of patients with adolescent idiopathic scoliosis (AIS). Recently, many studies have shown that gene polymorphism is related to osteoporosis. However, no studies have linked the association between IL6 gene polymorphism and bone mass in AIS. This study examined the association between bone mass and IL6 gene polymorphism in 198 girls with AIS. The polymorphisms of IL6-597 G→A, IL6-572 G→C and IL6-174 G→A and the bone mineral density in the lumbar spine and femoral neck were analysed and compared with their levels in healthy controls. The mean bone mineral density at both sites in patients with AIS was decreased compared with controls (p = 0.0022 and p = 0.0013, respectively). Comparison of genotype frequencies between AIS and healthy controls revealed a statistically significant difference in IL6-572 G→C polymorphism (p = 0.0305). There was a significant association between the IL6-572 G→C polymorphism and bone mineral density in the lumbar spine, with the CC genotype significantly higher with the GC (p = 0.0124) or GG (p = 0.0066) genotypes. These results suggest that the IL6-572 G→C polymorphism is associated with bone mineral density in the lumbar spine in Korean girls with AIS


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1509 - 1514
1 Nov 2010
Smolders JMH Hol A Rijnders T van Susante JLC

We undertook a randomised prospective follow-up study of changes in peri-prosthetic bone mineral density (BMD) after hip resurfacing and compared them with the results after total hip replacement. A total of 59 patients were allocated to receive a hip resurfacing (n = 29) or an uncemented distally fixed total hip replacement (n = 30). The BMD was prospectively determined in four separate regions of interest of the femoral neck and in the calcar region corresponding to Gruen zone 7 for the hip resurfacing group and compared only to the calcar region in the total hip replacement group. Standardised measurements were performed pre-operatively and after three, six and 12 months. The groups were well matched in terms of gender distribution and mean age. The mean BMD in the calcar region increased after one year to 105.2% of baseline levels in the resurfaced group compared with a significant decrease to 82.1% in the total hip replacement group (p < 0.001) by 12 months. For the resurfaced group, there was a decrease in bone density in all four regions of the femoral neck at three months which did not reach statistical significance and was followed by recovery to baseline levels after 12 months. Hip resurfacing did indeed preserve BMD in the inferior femoral neck. In contrast, a decrease in the mean BMD in Gruen zone 7 followed uncemented distally fixed total hip replacement. Long term follow-up studies are necessary to see whether this benefit in preservation of BMD will be clinically relevant at future revision surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 279 - 287
1 Mar 1993
Kilgus D Shimaoka E Tipton J Eberle R

The measurement of bone mineral density in defined areas around metal implants has improved with the development of dual-energy X-ray absorptiometry. We used this technique to compare the bone mineral density adjacent to metal cementless femoral implants with that of identical regions of bone in normal proximal femora. We studied the anteroposterior views only of 72 femora which contained total hip implants and 34 non-operated femora. We compared the regional bone mineral density of bone adjacent to proximally porous-coated and distally porous-coated implants of one design, to measure the relative differences in the remodelling changes induced by different amounts of porous coating. We also measured differences in bone density with time and with variations in implant size (and therefore stiffness). The greatest decrease in bone mineral density (34.8%) occurred in the most proximal 1 cm of the medial femoral cortex around relatively stiff, extensively porous-coated implants. The next most severe decrease (20% to 25%) was in the next most proximal 6 cm of the medial femoral cortex. Small, progressive decreases in bone mineral density continued for five to seven years after implantation


Aims. The aim of this study was to compare the mid-term patient-reported outcome, bone remodelling, and migration of a short stem (Collum Femoris Preserving; CFP) with a conventional uncemented stem (Corail). Methods. Of 81 patients who were initially enrolled, 71 were available at five years’ follow-up. The outcomes at two years have previously been reported. The primary outcome measure was the clinical result assessed using the Oxford Hip Score (OHS). Secondary outcomes were the migration of the stem, measured using radiostereometric analysis (RSA), change of bone mineral density (BMD) around the stem, the development of radiolucent lines, and additional patient-reported outcome measures (PROMs). Results. There were no statistically significant differences between the groups regarding PROMs (median OHS (CFP 45 (interquartile range (IQR) 35 to 48); Corail 45 (IQR 40 to 48); p = 0.568). RSA showed stable stems in both groups, with little or no further subsidence between two and five years. Resorption of the femoral neck was evident in nine patients in the CFP group and in none of the 15 Corail stems with a collar that could be studied. Dual X-ray absorbiometry showed a significantly higher loss of BMD in the proximal Gruen zones in the CFP group (mean changes in BMD: Gruen zone 1, CFP -9.5 (95% confidence interval (CI) -14.8 to -4.2), Corail 1.0 (95% CI 3.4 to 5.4); Gruen zone 7, CFP -23.0 (95% CI -29.4 to -16.6), Corail -7.2 (95% CI -15.9 to 1.4). Two CFP stems were revised before two years’ follow-up due to loosening, and one Corail stem was revised after two years due to chronic infection. Conclusion. The CFP stem has a similar clinical outcome and subsidence pattern when compared with the Corail stem. More pronounced proximal stress-shielding was seen with the CFP stem, suggesting diaphyseal fixation, and questioning its femoral neck-sparing properties in the long term. Cite this article: Bone Joint J 2022;104-B(5):581–588


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 87 - 89
1 Jan 2000
Wigderowitz CA Rowley DI Mole PA Paterson CR Abel EW

To ascertain whether patients with Colles’ fracture should be investigated for osteoporosis and the risk of future fractures, we measured the bone mineral density of the distal radius of the other arm in 31 women patients and compared the results with those of a control group of 289 normal women. We divided the patients into two groups, those younger than 66 years and those older. In 25 patients we found values for bone mineral density which were lower than one standard deviation below the mean value for their age. Younger patients had a deficit greater than that expected for their ages. We believe that women with Colles’ fracture should be evaluated routinely for osteoporosis, particularly if they are under 66 years of age


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1036 - 1044
1 Aug 2012
Penny JO Brixen K Varmarken JE Ovesen O Overgaard S

It is accepted that resurfacing hip replacement preserves the bone mineral density (BMD) of the femur better than total hip replacement (THR). However, no studies have investigated any possible difference on the acetabular side. Between April 2007 and March 2009, 39 patients were randomised into two groups to receive either a resurfacing or a THR and were followed for two years. One patient’s resurfacing subsequently failed, leaving 19 patients in each group. Resurfaced replacements maintained proximal femoral BMD and, compared with THR, had an increased bone mineral density in Gruen zones 2, 3, 6, and particularly zone 7, with a gain of 7.5% (95% confidence interval (CI) 2.6 to 12.5) compared with a loss of 14.6% (95% CI 7.6 to 21.6). Resurfacing replacements maintained the BMD of the medial femoral neck and increased that in the lateral zones between 12.8% (95% CI 4.3 to 21.4) and 25.9% (95% CI 7.1 to 44.6). On the acetabular side, BMD was similar in every zone at each point in time. The mean BMD of all acetabular regions in the resurfaced group was reduced to 96.2% (95% CI 93.7 to 98.6) and for the total hip replacement group to 97.6% (95% CI 93.7 to 101.5) (p = 0.4863). A mean total loss of 3.7% (95% CI 1.0 to 6.5) and 4.9% (95% CI 0.8 to 9.0) of BMD was found above the acetabular component in W1 and 10.2% (95% CI 0.9 to 19.4) and 9.1% (95% CI 3.8 to 14.4) medial to the implant in W2 for resurfaced replacements and THRs respectively. Resurfacing resulted in a mean loss of BMD of 6.7% (95% CI 0.7 to 12.7) in W3 but the BMD inferior to the acetabular component was maintained in both groups. These results suggest that the ability of a resurfacing hip replacement to preserve BMD only applies to the femoral side