Advertisement for orthosearch.org.uk
Results 1 - 20 of 89
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 245 - 250
1 Feb 2011
Wilson J Bajwa A Kamath V Rangan A

Compression and absolute stability are important in the management of intra-articular fractures. We compared tension band wiring with plate fixation for the treatment of fractures of the olecranon by measuring compression within the fracture. Identical transverse fractures were created in models of the ulna. Tension band wires were applied to ten fractures and ten were fixed with Acumed plates. Compression was measured using a Tekscan force transducer within the fracture gap. Dynamic testing was carried out by reproducing cyclical contraction of the triceps of 20 N and of the brachialis of 10 N. Both methods were tested on each sample. Paired t-tests compared overall compression and compression at the articular side of the fracture. The mean compression for plating was 819 N (. sd. 602, 95% confidence interval (CI)) and for tension band wiring was 77 N (. sd. 19, 95% CI) (p = 0.039). The mean compression on the articular side of the fracture for plating was 343 N (. sd. 276, 95% CI) and for tension band wiring was 1 N (. sd. 2, 95% CI) (p = 0.038). During simulated movements, the mean compression was reduced in both groups, with tension band wiring at −14 N (. sd. 7) and for plating −173 N (. sd. 32). No increase in compression on the articular side was detected in the tension band wiring group. Pre-contoured plates provide significantly greater compression than tension bands in the treatment of transverse fractures of the olecranon, both over the whole fracture and specifically at the articular side of the fracture. In tension band wiring the overall compression was reduced and articular compression remained negligible during simulated contraction of the triceps, challenging the tension band principle


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 728 - 729
1 Nov 1988
Jakim I Sweet M

We report a case of transverse fracture through the body of the axis. This fracture was unstable, had been produced by extension forces and was managed conservatively. The classification of such fractures is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 969 - 971
1 Nov 1991
Phelan S Jones D Bishay M

Transverse fractures of the sacrum with neurological complications have been studied in four patients illustrating the following features: diagnosis is often delayed, there are radiological difficulties in making the diagnosis, and the indications for surgery are not well defined. Specific radiographic views are recommended. All the cases presented in this report responded well to conservative management


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 137 - 142
1 Mar 2024
van Veghel MHW van der Koelen RE Hannink G Schreurs BW Rijnen WHC

Aims. The aim of this study was to report the long-term follow-up of cemented short Exeter femoral components when used in primary total hip arthroplasty (THA). Methods. We included all primary 394 THAs with a cemented short Exeter femoral component (≤ 125 mm) used in our tertiary referral centre between October 1993 and December 2021. A total of 83 patients (21%) were male. The median age of the patients at the time of surgery was 42 years (interquartile range (IQR) 30 to 55). The main indication for THA was a childhood hip disease (202; 51%). The median follow-up was 6.7 years (IQR 3.1 to 11.0). Kaplan-Meier survival analyses were performed to determine the rates of survival with femoral revision for any indication, for septic loosening, for fracture of the femoral component and for aseptic loosening as endpoints. The indications for revision were evaluated. Fractures of the femoral component were described in detail. Results. The 20-year rate of survival was 85.4% (95% confidence interval (CI) 73.9 to 92.0) with revision for any indication, 96.2% (95% CI 90.5 to 98.5) with revision for septic loosening and 92.7% (95% CI 78.5 to 97.6) with revision for fracture of the femoral component. No femoral components were revised for aseptic loosening. There were 21 revisions of the femoral component; most (seven) as part of a two-stage management of infection. Fracture of the femoral component occurred in four THAs (1.0%) at 6.6, 11.6, 16.5, and 18.2 years of follow-up, respectively. Three of these were transverse fractures and occurred at the level of the lesser trochanter. In one THA, there was a fracture of the neck of the component. Conclusion. THAs using cemented short Exeter femoral components showed acceptable rates of survival of the femoral component at long-term follow-up, in this young cohort of patients. Although fracture is a rare complication of these components, surgeons should be aware of their incidence and possible risk factors. Cite this article: Bone Joint J 2024;106-B(3 Supple A):137–142


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 4 | Pages 728 - 738
1 Nov 1965
Devas MB

1. Stress fractures of the femoral neck in twenty-five patients are described. 2. Two distinct radiological types, compression fractures and transverse fractures, are described. A clinical distinction cannot be made in the early stages. 3. The importance of the early differential diagnosis between the two types is emphasised because the transverse stress fracture of the femoral neck will become displaced. 4. The morbidity after a displaced transverse fracture of the femoral neck can be severe


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 112 - 123
1 Feb 2023
Duckworth AD Carter TH Chen MJ Gardner MJ Watts AC

Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered.

Cite this article: Bone Joint J 2023;105-B(2):112–123.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 315 - 319
1 Feb 2010
Lalliss SJ Branstetter JG

Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when using a tension-band technique to stabilise the bone. Physiological cyclical loading simulating passive elbow movement (15 N) and using the arms to push up from a chair (450 N) were applied using an Instron materials testing machine whilst monitoring the osteotomy site with a video extensometer. Each osteotomy was repaired by one of four materials, namely, Stainless Steel Wire (7), No 2 Ethibond (3), No 5 Ethibond (5), or No 2 FiberWire (7). There were no failures (movement of > 2 mm) with stainless steel wire or FiberWire and no significant difference in the movements measured across the site of the osteotomy (p = 0.99). The No. 2 Ethibond failed at 450 N and two of the five of No. 5 Ethibond sutures had a separation of > 2 mm at 450 N. FiberWire as the tension band in this model held the reduction as effectively as stainless steel wire and may reduce the incidence of discomfort from the hardware. On the basis of our findings we suggest that a clinical trial should be undertaken


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 568 - 574
1 May 2023
Kobayashi H Ito N Nakai Y Katoh H Okajima K Zhang L Tsuda Y Tanaka S

Aims

The aim of this study was to report the patterns of symptoms and insufficiency fractures in patients with tumour-induced osteomalacia (TIO) to allow the early diagnosis of this rare condition.

Methods

The study included 33 patients with TIO who were treated between January 2000 and June 2022. The causative tumour was detected in all patients. We investigated the symptoms and evaluated the radiological patterns of insufficiency fractures of the rib, spine, and limbs.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 481 - 486
1 May 2023
Scott CEH Jain S Moran M Haddad FS

The Unified Classification System (UCS), or Vancouver system, is a validated and widely used classification system to guide the management of periprosthetic femoral fractures. It suggests that well-fixed stems (type B1) can be treated with fixation but that loose stems (types B2 and B3) should be revised. Determining whether a stem is loose can be difficult and some authors have questioned how to apply this classification system to polished taper slip stems which are, by definition, loose within their cement mantle. Recent evidence has challenged the common perception that revision surgery is preferable to fixation surgery for UCS-B periprosthetic fractures around cemented polished taper slip stems. Indications for fixation include an anatomically reducible fracture and cement mantle, a well-fixed femoral bone-cement interface, and a well-functioning acetabular component. However, not all type B fractures can or should be managed with fixation due to the risk of early failure. This annotation details specific fracture patterns that should not be managed with fixation alone.

Cite this article: Bone Joint J 2023;105-B(5):481–486.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1273 - 1278
1 Nov 2022
Chowdhury JMY Ahmadi M Prior CP Pease F Messner J Foster PAL

Aims

The aim of this retrospective cohort study was to assess and investigate the safety and efficacy of using a distal tibial osteotomy compared to proximal osteotomy for limb lengthening in children.

Methods

In this study, there were 59 consecutive tibial lengthening and deformity corrections in 57 children using a circular frame. All were performed or supervised by the senior author between January 2013 and June 2019. A total of 25 who underwent a distal tibial osteotomy were analyzed and compared to a group of 34 who had a standard proximal tibial osteotomy. For each patient, the primary diagnosis, time in frame, complications, and lengthening achieved were recorded. From these data, the frame index was calculated (days/cm) and analyzed.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 21 - 28
1 Jan 2023
Ndlovu S Naqshband M Masunda S Ndlovu K Chettiar K Anugraha A

Aims

Clinical management of open fractures is challenging and frequently requires complex reconstruction procedures. The Gustilo-Anderson classification lacks uniform interpretation, has poor interobserver reliability, and fails to account for injuries to musculotendinous units and bone. The Ganga Hospital Open Injury Severity Score (GHOISS) was designed to address these concerns. The major aim of this review was to ascertain the evidence available on accuracy of the GHOISS in predicting successful limb salvage in patients with mangled limbs.

Methods

We searched electronic data bases including PubMed, CENTRAL, EMBASE, CINAHL, Scopus, and Web of Science to identify studies that employed the GHOISS risk tool in managing complex limb injuries published from April 2006, when the score was introduced, until April 2021. Primary outcome was the measured sensitivity and specificity of the GHOISS risk tool for predicting amputation at a specified threshold score. Secondary outcomes included length of stay, need for plastic surgery, deep infection rate, time to fracture union, and functional outcome measures. Diagnostic test accuracy meta-analysis was performed using a random effects bivariate binomial model.


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 448 - 451
1 Aug 1983
Levai J McLeod H Freeman M

The results of resurfacing or not resurfacing the articular cartilage of the patella were reviewed in 71 knees--47 with rheumatoid arthritis and 24 with osteoarthritis--which had been replaced with the ICLH prosthesis. Two rheumatoid and osteoporotic patellae developed transverse fractures with separation and were excluded from the review. The results showed that resurfacing the patella greatly reduced peripatellar pain with no counter-balancing disadvantage


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 386 - 389
1 May 1988
Cooke P Newman J

We have reviewed the results of treating 75 fractures of the proximal femoral shaft in the presence of a cemented femoral prosthesis. A simple radiographic classification into four types is proposed, and suggestions are made on the appropriate management of each. Comminuted fractures around the implant need early revision, whilst spiral fractures in this region may be treated conservatively or by operation. Transverse fractures at the level of the tip of the prosthesis are difficult to manage, and may require open reduction and internal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 1 | Pages 162 - 166
1 Feb 1961
Alms M

1. Linear fractures of the shaft of the long bones are divided into four basic types: 1) transverse; 2) oblique transverse; 3) spiral; and 4) oblique. 2. The mode of production of these fractures is deduced on the grounds of simple mechanical theory: 1) transverse fractures are a result of angulation; 2) oblique transyerse are the result of angulation with axial loading; 3) spiral fractures are the result of axial twists with or without axial loading; 4) oblique fractures are the result of angulation and axial twisting in the presence of axial loading


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 450 - 453
1 Nov 1980
Loudon Charnley J

A method is described of measuring radiological subsidence of a femoral prosthesis in relation to the femur after total hip arthroplasty. The method depends on measuring the distance from the tip of the femoral prosthesis to a fixed point in the bone. Subsidence after the use of a conventional design of femoral stem is compared with that after the use of a stem with a dorsal flange (Cobra). A significant reduction in the incidence and amount of subsidence was found when using the dorsal flange. There was also a notable absence of transverse fractures involving the cement near the tip of the stem, which occurred in 26 per cent of the cases using a conventional prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 225 - 230
1 May 1981
Leslie I Dickson R

The scaphoid fracture is commonest in young men in the age group 15 to 29 years, who have the highest incidence of non-union, take the longest time to unite, lose more time from work, and spend the longest time as outpatients. A union rate of 95 per cent can be achieved using standard simple treatment. All but a few fractures are visible on the first radiograph, and failure of visualisation at this stage is not associated with a bad outcome. The postero-anterior and semipronated views are the most important to scrutinise. Crank-handle injuries have a particularly bad prognosis when they produce a transverse fracture of the waist of the scaphoid. Poor prognostic factors are displacement during treatment, the fracture line becoming increasingly more obvious, and the presence of early cystic change. The severity of trauma is an important factor to elicit from the history


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 1 | Pages 105 - 111
1 Feb 1966
Klenerman L

1. It appears that fracture of the humeral shaft occurs more often in persons over fifty. This incidence corresponds with that found in a study carried out by the Pennsylvania Orthopaedic Society in 1959. 2. The middle third of the bone is the most vulnerable portion of the shaft, where transverse fracture and radial nerve palsy most commonly occur. 3. Most fractures of the shaft of the humerus are best treated by simple splintage. The degree of radiological deformity that can be accepted is far greater than in other long bones. In this group anterior bowing of 20 degrees or varus of 30 degrees was present before it became clinically obvious and even then the function of the limb was good. 4. Internal fixation is only occasionally indicated but operation on the middle third of the bone increased the chances of delayed union. 5. In the treatment of delayed union intramedullary fixation and the application of slivers of iliac bone is effective in stimulating the fracture to join


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 3 | Pages 633 - 640
1 Aug 1960
Hirsch C Frankel VH

1. If a vertical load is applied to the head of the femur parallel to its shaft, the upper cortex is stretched and the lower cortex is compressed. The neck breaks from the upper subcapital border to the lesser trochanter. This type of fracture is rarely found clinically. 2. If a compressive force is applied to the area between head and greater trochanter while the head is loaded vertically, a transverse fracture of clinical appearance is produced. If this axial pressure acts along the part of the neck above the central axis a subcapital comminuted fracture results. If the pressure acts below the central axis the result is a transcervical fracture. 3. Strain gauge experiments have shown that axial compression within the upper segment of the neck is produced by the abductor muscles of the hip. Adductor muscles produce a low axial compression. It is suggested that muscular action at the time of injury influences the type of fracture produced by the injury


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 3 | Pages 563 - 570
1 Aug 1967
Scapinelli R

1. A study has been made of the blood supply of the human patella. There are two main systems, one penetrating the middle third of the anterior surface and the other entering the lower pole of the bone behind the patellar ligament. 2. The relationship between these findings and the complication of avascular necrosis of the upper fragment of the patella after fracture is discussed. Forty-one cases of necrosis after operation have been studied and notes made on the pathological, clinical and radiological evolution of the condition. Whatever the severity of the ischaemic necrosis the prognosis was not substantially affected and good function was observed in all knees six months after injury. 3. The surgical implications of the vascular anatomy are discussed. It is pointed out that surgical intervention may damage the blood vessels entering the anterior surface of the bone and that circumferential repair of patellar fractures may strangle the vessels in their peripatellar course. 4. If removal of one-half of the patella after a transverse fracture is indicated, vascular studies indicate that the upper fragment should be removed


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1339 - 1344
1 Aug 2021
Jain S Mohrir G Townsend O Lamb JN Palan J Aderinto J Pandit H

Aims

This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems.

Methods

Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs.