We report on the use of the Ilizarov method to
treat 40 consecutive fractures of the
Hindfoot (subtalar) movement and disability after fracture of the
One hundred patients who had sustained a fracture of the
We performed a prospective randomised trial on matched groups of patients with displaced
One hundred consecutive closed fractures of the adult
1. One hundred and eighty-one fractures of the
1. A study of the late results of 343 soundly united
We analysed the results of 93
1 . A series of 343
All
1. Eighty consecutive open fractures of the
We measured pressures in the anterior and deep posterior compartments continuously for up to 72 hours in 20 patients with closed fractures of the
The stability of union following the conservative treatment of
A prospective study of 141 patients with 143
We have reviewed our recent results with functional bracing of
1. A series of 705 fractures of the tibia is reviewed, 674 of which were treated conservatively. 2. The factors most conducive to delayed or non-union are initial displacement, comminution, associated soft-tissue wound and infection. The extent to which these are combined in any fracture determines its "personality" and its inherent propensity for union. 3. Eight fracture types are differentiated based on the above "personality rating." The incidence of delayed union or non-union varies from 9 per cent in the most favourable type to 39 per cent in the least favourable. Infection raises the incidence to 60 per cent. Comparative statistics which fail to recognise these differences can be entirely misleading. 4. Continuous traction does not retard union. 5. The results of conservative treatment are analysed with regard to union, deformity, stiff joints and contractures and the conclusion is reached that no case has yet been made out for internal fixation as the method of choice in the treatment of this fracture.
1. The probable greatest bending moment applied to a plated or nailed fracture of the tibia during restricted weight-bearing is estimated to be, in men, up to about 79 Newton metres (58 poundsforce feet). The maximum twisting moment is estimated to be about 29 Newton metres (22 poundsforce feet). 2. Twenty-two human tibiae were loaded in three-point bending and broke at bending moments of from 57·9 to 294 Newton metres (42·7 to 216 poundsforce feet) if they had not previously been drilled; tibiae which had holes made through both cortices with a c. 3-millimetre (⅛-inch) drill broke at from 32·4 to 144 Newton metres (23·8 to 106 poundsforce feet). Tibiae loaded in torsion broke at twisting moments of from 27·5 to 892 Newton metres (20·2 to 65·8 poundsforce feet) when not drilled, 23·6 to 77·5 Newton metres (l7·3 to 57·1 poundsforce feet) when drilled. 3. When bent so as to open the fracture site, the 14-centimetre Stamm was the strongest of all the single plates tested (reaching its elastic limit at a bending moment of 17·6 Newton metres (13 poundsforce feet) and 5 degrees total angulation at 22·6 Newton metres (16·6 poundsforce feet)), while the Venable was the weakest (elastic limit 4·9 Newton metres (3·6 poundsforce feet) and 5 degrees at 7·9 Newton metres (5·8 poundsforce feet)). A 13-millimetre Küntscher nail reached its elastic limit at 42·2 Newton metres (31·1 poundsforce feet) and 5 degrees total angulation at 49 Newton metres (36 poundsforce feet). 4. In torsion the 15-centimetre Hicks was the strongest ofthe plates (elastic limit 27·5 Newton metres (20·2 poundsforce feet) and 5 degrees rotation at 16·7 Newton metres (l2·3 poundsforce feet)). 5. Küntscher nails in bones provided no dependable strength in torsion. 6. In both bending and torsion, a preparation of one Venable plate on each of the two anterior surfaces was stronger than any single plate, and was as strong as the weaker drilled tibiae. 7. The three currently available metallic materials (stainless steel, cobalt-chrome and titanium) have static mechanical properties so similar that the choice between them can be made on other grounds. 8. The highest load applied to a screw during bending tests was about half that needed to pull a screw out of even a thin-walled tibia. 9. Screws beyond four for one plate are mechanically redundant at the moment of implantation but may be necessary as an insurance against subsequent deterioration in strength. 10. Countersinks in plates are a source of significant weakness, and should preferably be as shallow as possible. 11. An unoccupied screw hole in the centre of a plate is a source of serious weakness. 12. Only the strongest implants tested were strong enough to withstand the bending or twisting moments to be expected in restricted weight-bearing. In two-plate preparations a danger is introduced by the fact that these moments are similar to those required to Ireak a drilled tibia.
1. The thesis is advanced that in the treatment of fractures of the adult tibia rigid fixation is desirable. 2. The mechanical factors are discussed and a technique is described which provides a high degree of fixation without exposing more than one surface of the bone. 3. The process of healing of such fractures is described and the results in thirty-three unselected patients are given.