Advertisement for orthosearch.org.uk
Results 1 - 20 of 742
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1575 - 1580
1 Nov 2005
Böstman OM Laitinen OM Tynninen O Salminen ST Pihlajamäki HK

Despite worldwide clinical use of bio-absorbable devices for internal fixation in orthopaedic surgery, the degradation behaviour and tissue replacement of these implants are not fully understood. In a long-term experimental study, we have determined the patterns of tissue restoration 36 and 54 months after implantation of polyglycolic acid and poly-laevo-lactic acid screws in the distal femur of the rabbit. After 36 months in the polyglycolic acid group the specimens showed no remaining polymer and loose connective tissue occupied 80% of the screw track. Tissue restoration remained poor at 54 months, the amounts of trabecular bone and haematopoietic elements being significantly lower than those in the intact control group. The amount of trabecular bone within the screw track at 54 months in the polyglycolic acid group was less than in the empty drill holes (p = 0.04). In the poly-laevo-lactic acid group, polymeric material was present in abundance after 54 months, occupying 60% of the cross-section of the core area of the screw track. When using absorbable internal fixation implants we should recognise that the degradation of the devices will probably not be accompanied by the restoration of normal trabecular bone


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1033 - 1034
1 Sep 2019
Rodeo S Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 3 | Pages 455 - 473
1 Aug 1966
Tubiana R Stack HG Hakstian RW

1. Prehension is a complex mechanism for which both movement and sensation are required. 2. Two basic grips are considered: the digital pinch and palmar grasp, which are simpler expressions of the precision grip and the power grip. For the digital pinch the minimum requirement is a thumb or a reconstructed thumb, and a finger to which it can oppose. For palmar grasp mobile fingers are necessary so that they can wrap round the object grasped. 3. The restoration of prehension is considered under the following headings: mutilation of the fingers; mutilation of the thumb; and mutilation of both together. 4. The various methods of reconstruction are described that are appropriate to each type of mutilation, so as to provide restoration of length, mobility and sensation. 5. The indications for the various main methods to compensate for loss of the thumb are discussed. These methods include pollicisation and osteoplastic repair with neurovascular island flap


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 148 - 159
1 May 1975
Burrows HJ Wilson JN Scales JT

A personal experience is recounted of operations in cases of tumour involving the humerus or femur with restoration by endoprostheses. Twenty-four patients were treated in this way from 1950 to 1969 inclusive and have been followed up for between four and twenty-four years. The patients selected for treatment have presented chondrosarcoma (ten), so-called benign giant-cell tumour of bone, usually recurrent (nine), angiomatous osteolysis (two), seemingly single thyroid or renal metastasis (two), and ununited pathological fracture after irradiation of a tumour (one). Development of the prostheses from early beginnings is outlined. Some points in surgical management are referred to. The complications and results are recorded


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1597 - 1603
1 Dec 2016
Meermans G Doorn JV Kats J

Aims

One goal of total hip arthroplasty is to restore normal hip anatomy. The aim of this study was to compare displacement of the centre of rotation (COR) using a standard reaming technique with a technique in which the acetabulum was reamed immediately peripherally and referenced off the rim.

Patients and Methods

In the first cohort the acetabulum was reamed to the floor followed by sequentially larger reamers. In the second cohort the acetabulum was only reamed peripherally, starting with a reamer the same size as the native femoral head. Anteroposterior pelvic radiographs were analysed for acetabular floor depth and vertical and horizontal position of the COR.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1524 - 1532
1 Nov 2018
Angélico ACC Garcia LM Icuma TR Herrero CF Maranho DA

Aims

The aims of this study were to evaluate the abductor function in moderate and severe slipped capital femoral epiphysis (SCFE), comparing the results of a corrective osteotomy at the base of the femoral neck and osteoplasty with 1) in situ epiphysiodesis for mild SCFE, 2) contralateral unaffected hips, and 3) hips from healthy individuals.

Patients and Methods

A total of 24 patients (mean age 14.9 years (sd 1.6); 17 male and seven female patients) with moderate or severe SCFE (28 hips) underwent base of neck osteotomy and osteoplasty between 2012 and 2015. In situ epiphysiodesis was performed in seven contralateral hips with mild slip. A control cohort was composed of 15 healthy individuals (mean age 16.5 years (sd 2.5); six male and nine female patients). The abductor function was assessed using isokinetic dynamometry and range of abduction, with a minimum one-year follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1182 - 1182
1 Aug 2010
Nairn DS


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 238 - 243
1 Feb 2016
Qian L Li P Wu W Fang Y Zhang J Ouyang J

Aims

This study aimed to determine the relationship between pedicle-lengthening distance and bulge-canal volume ratio in cases of lumbar spinal stenosis, to provide a theoretical basis for the extent of lengthening in pedicle-lengthening osteotomies.

Methods

Three-dimensional reconstructions of CT images were performed for 69 patients (33 men and 36 women) (mean age 49.96 years; 24 to 81). Simulated pedicle-lengthening osteotomies and disc bulge and spinal canal volume calculations were performed using Mimics software.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1099 - 1109
1 Aug 2007
Munirah S Samsudin OC Chen HC Salmah SHS Aminuddin BS Ruszymah BHI

Ovine articular chondrocytes were isolated from cartilage biopsy and culture expanded in vitro. Approximately 30 million cells per ml of cultured chondrocytes were incorporated with autologous plasma-derived fibrin to form a three-dimensional construct. Full-thickness punch hole defects were created in the lateral and medial femoral condyles. The defects were implanted with either an autologous ‘chondrocyte-fibrin’ construct (ACFC), autologous chondrocytes (ACI) or fibrin blanks (AF) as controls. Animals were killed after 12 weeks. The gross appearance of the treated defects was inspected and photographed. The repaired tissues were studied histologically and by scanning electron microscopy analysis.

All defects were assessed using the International Cartilage Repair Society (ICRS) classification. Those treated with ACFC, ACI and AF exhibited median scores which correspond to a nearly-normal appearance. On the basis of the modified O’Driscoll histological scoring scale, ACFC implantation significantly enhanced cartilage repair compared to ACI and AF. Using scanning electron microscopy, ACFC and ACI showed characteristic organisation of chondrocytes and matrices, which were relatively similar to the surrounding adjacent cartilage.

Implantation of ACFC resulted in superior hyaline-like cartilage regeneration when compared with ACI. If this result is applicable to humans, a better outcome would be obtained than by using conventional ACI.


The Journal of Bone & Joint Surgery British Volume
Vol. 40-B, Issue 4 | Pages 742 - 764
1 Nov 1958
Allbrook D Kirkaldy-Willis WH

The experiments were performed to answer three main questions. These and our answers may be summarised as follows.

What is the precise mechanism of healing of a raw bony surface in a joint? What cells are involved? Where do they originate?—In all the implant experiments and in the control series the fundamental mechanism of healing was similar.

1. A massive proliferation of fibroblasts occurred from the cut periosteum, from the cut joint capsule, and to a lesser extent from the medullary canal.

2. Fibroblasts grew centripetally in the first few weeks after operation, attempting to form a "fibroblast cap" to the cut bone end.

3. Fibroblasts of this cap near the cut bone spicules metamorphosed to become prechondroblasts, chondroblasts laying down cartilage matrix, and hypertrophied (alkaline phosphatase-secreting) chondrocytes lying in a calcified matrix.

4. This calcified cartilage matrix was invaded by dilated capillaries probably bearing osteoblasts which laid down perivascular (endochondral) bone.

5. Some of the cells of projecting bone spicules died and their matrix was eroded in the presence of many osteoclasts.

6. In the control experiments of simple excision of the radial head new bone was produced at the periphery only by processes (3) and (4). This sealed off the underlying peripheral cortical bone from the superficially placed peripheral articular surface of fibrocartilage. At about a year from operation the central portion of the articular surface was still formed of bare bone, or of bone spicules covered by a thin layer of irregularly arranged collagen fibres. The opposite capitular articular cartilage was badly eroded.

Does the introduction of a dead cartilage implant over the raw bone end affect in any way the final constitution of the new articular surface?—In the implant experiments the new bone produced by processes (3) and (4) formed, after about a year, a complete cortical plate which entirely sealed off the cut end of the radius and left a superficially placed articular covering of smooth fibrocartilage, closely resembling a normal joint surface. The opposite capitular articular surface was normal.

What is the final fate of such an implant?—Whale cartilage implants underwent replacement by fibroblasts and collagen fibres, and took about nine months to disappear.

The cartilage of fixed autotransplants and homotransplants underwent similar gradual replacement, and took about the same time in each case. The dead bone, implanted in association with the cartilage in both cases, acted as a nidus for hyaline cartilage production by chondrocytes derived from fibroblasts. This cartilage underwent endochondral ossification. This observation suggests that induction by non-cellular osseous material is a factor in chondrification and ossification.

All the implants functioned as temporary articular menisci or in some cases as temporary radial articular surfaces. They were always replaced by a permanent fibrocartilaginous meniscus, or a fibrocartilaginous articular surface. An implant did, in fact, always act as a temporary protecting cap and mould for the subjacent growth offibroblasts which was necessary for the production of a satisfactory new joint surface.


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 2 | Pages 217 - 219
1 May 1976
Williams P

A new technique of tibialis posterior transfer is described which has been used in a wide variety of conditions producing muscular imbalance in the foot. The results in eighty-five feet are reviewed in terms of range of motion, power and voluntary control of the transfer. The effect of the transfer on shoe wear, on the necessity for bracing and on the child's or his parents' assessment of the results are used to allocate an overall evaluation of the operation. Recommendations on the indications for the operation are given.


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 3 | Pages 474 - 480
1 Aug 1961
Tubiana R Duparc J

In ten cases definitive loss of sensibility in an important territory of the hand has been treated by a hetero-digital, neurovascular skin island transfer. Operative technique and results obtained are reported. Although not enough patients have been treated to allow us to give precise indications for the procedure, two such indications clearly emerge: 1) the treatment of insensitive digits; 2) the reconstruction of the thumb or fingers. The procedure could probably be used elsewhere than in the hand.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 399 - 403
1 Aug 1981
Baksi D

Lateral instability of the patella was found after recurrent, habitual and permanent dislocations. Contracture of soft tissues lateral to the patella only occurred with habitual and permanent dislocations, but medial laxity was present in all cases. After adequate release of the lateral contracture, the medial stability was improved by transposition of the lower three-quarters of the pes anserinus to the medial border of the patella, and the patellar ligament. This created a relatively unstretchable physiological sling which ensured dynamic stability of the patella. Six recurrent, 21 habitual and nine permanent dislocations of the patella were treated by this method. Results were excellent in 21 patients, good in 13 and fair in two. The follow-up period varied from 21 to 84 months. There have been no recurrences to date.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 246 - 248
1 Feb 2007
Funahashi S Nagano A Sano M Ogihara H Omura T

We report the case of an eight-month-old girl who presented with a poliomyelitis-like paralysis in her left upper limb caused by enterovirus 71 infection. She recovered useful function after nerve transfers performed six months after the onset of paralysis. Early neurotisation can be used successfully in the treatment of poliomyelitis-like paralysis in children.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 817 - 825
1 Aug 2024
Borukhov I Ismailidis P Esposito CI LiArno S Lyon J McEwen PJ

Aims. This study aimed to evaluate if total knee arthroplasty (TKA) femoral components aligned in either mechanical alignment (MA) or kinematic alignment (KA) are more biomimetic concerning trochlear sulcus orientation and restoration of trochlear height. Methods. Bone surfaces from 1,012 CT scans of non-arthritic femora were segmented using a modelling and analytics system. TKA femoral components (Triathlon; Stryker) were virtually implanted in both MA and KA. Trochlear sulcus orientation was assessed by measuring the distal trochlear sulcus angle (DTSA) in native femora and in KA and MA prosthetic femoral components. Trochlear anatomy restoration was evaluated by measuring the differences in medial, lateral, and sulcus trochlear height between native femora and KA and MA prosthetic femoral components. Results. Femoral components in both MA and KA alignments exhibited a more valgus DTSA compared to native femora. However, DTSA deviation from native was significantly less in KA than in MA (4.8° (SD 2.2°) vs 8.8° (SD 1.8°); p < 0.001). DTSA deviation from native orientation correlated positively with the mechanical lateral distal femoral angle (mLDFA) in KA and negatively in MA (r = 0.53, p < 0.001; r = -0.18, p < 0.001). Medial trochlear height was not restored with either MA or KA, with MA resulting in lower medial trochlear height than KA in the proximal 20% of the trochlea. Lateral and sulcus trochlear height was not restored with either alignment in the proximal 80% of the trochlea. At the terminal arc point, KA replicated sulcus and lateral trochlear height, while MA led to over-restoration. Conclusion. Femoral components aligned in KA demonstrated greater biomimetic qualities than those in MA regarding trochlear sulcus orientation and trochlear height restoration, particularly in valgus femora. Variability across knees was observed, warranting further research to evaluate the clinical implications of these findings. Cite this article: Bone Joint J 2024;106-B(8):817–825


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 532 - 539
1 Jun 2024
Lei T Wang Y Li M Hua L

Aims. Intra-articular (IA) injection may be used when treating hip osteoarthritis (OA). Common injections include steroids, hyaluronic acid (HA), local anaesthetic, and platelet-rich plasma (PRP). Network meta-analysis allows for comparisons between two or more treatment groups and uses direct and indirect comparisons between interventions. This network meta-analysis aims to compare the efficacy of various IA injections used in the management of hip OA with a follow-up of up to six months. Methods. This systematic review and network meta-analysis used a Bayesian random-effects model to evaluate the direct and indirect comparisons among all treatment options. PubMed, Web of Science, Clinicaltrial.gov, EMBASE, MEDLINE, and the Cochrane Library were searched from inception to February 2023. Randomized controlled trials (RCTs) which evaluate the efficacy of HA, PRP, local anaesthetic, steroid, steroid+anaesthetic, HA+PRP, and physiological saline injection as a placebo, for patients with hip OA were included. Results. In this meta-analysis of 16 RCTs with a total of 1,735 participants, steroid injection was found to be significantly more effective than placebo injection on reported pain at three months, but no significant difference was observed at six months. Furthermore, steroid injection was considerably more effective than placebo injection for functional outcomes at three months, while the combination of HA+PRP injection was substantially more effective at six months. Conclusion. Evidence suggests that steroid injection is more effective than saline injection for the treatment of hip joint pain, and restoration of functional outcomes. Cite this article: Bone Joint J 2024;106-B(6):532–539


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 89 - 97
1 May 2024
Scholz J Perka C Hipfl C

Aims. There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation. Methods. We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75). Results. DM bearings were used significantly more frequently in elderly patients (p = 0.003) and in hips with abductor deficiency (p < 0.001). The re-dislocation rate was 13.2% for DM bearings compared with 17.9% for standard bearings, and 22.2% for constrained liners (p = 0.432). Re-revision-free survival for DM bearings was 84% (95% confidence interval (CI) 0.77 to 0.91) compared with 74% (95% CI 0.67 to 0.81) for standard articulations, and 67% (95% CI 0.51 to 0.82) for constrained liners (p = 0.361). Younger age (hazard ratio (HR) 0.92 (95% CI 0.85 to 0.99); p = 0.031), lower comorbidity (HR 0.44 (95% CI 0.20 to 0.95); p = 0.037), smaller heads (HR 0.80 (95% CI 0.64 to 0.99); p = 0.046), and retention of the acetabular component (HR 8.26 (95% CI 1.37 to 49.96); p = 0.022) were significantly associated with re-dislocation. All DM bearings which re-dislocated were in patients with abductor muscle deficiency (HR 48.34 (95% CI 0.03 to 7,737.98); p = 0.303). The radiological analysis did not reveal a significant relationship between restoration of the geometry of the hip and re-dislocation. The mean mHHSs significantly improved from 43 points (0 to 88) to 67 points (20 to 91; p < 0.001) at the final follow-up, with no differences between the types of bearing. Conclusion. We found that the use of DM bearings reduced the rates of re-dislocation and re-revision in revision THA for recurrent dislocation, but did not guarantee stability. Abductor deficiency is an important predictor of persistent instability. Cite this article: Bone Joint J 2024;106-B(5 Supple B):89–97


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 74 - 81
1 May 2024
Callary SA Broekhuis D Barends J Ramasamy B Nelissen RGHH Solomon LB Kaptein BL

Aims. The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) – the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) – using virtual modelling. Methods. Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants. Results. The median amount of bone removed for TMARS reconstructions was significantly greater than for CTAC implants (9.07 cm. 3. (interquartile range (IQR) 5.86 to 21.42) vs 1.16 cm. 3. (IQR 0.42 to 3.53) (p = 0.004). There was no significant difference between the median overall implant-bone apposition between TMARS reconstructions and CTAC implants (54.8 cm. 2. (IQR 28.2 to 82.3) vs 56.6 cm. 2. (IQR 40.6 to 69.7) (p = 0.683). However, there was significantly more implant-bone apposition within the residual acetabulum (45.2 cm. 2. (IQR 28.2 to 72.4) vs 25.5 cm. 2. (IQR 12.8 to 44.1) (p = 0.001) and conversely significantly less apposition with the outer cortex of the pelvis for TMARS implants compared with CTAC reconstructions (0 cm. 2. (IQR 0 to 13.1) vs 23.2 cm. 2. (IQR 16.4 to 30.6) (p = 0.009). The mean centre of rotation of the hip of TMARS reconstructions differed by a mean of 11.1 mm (3 to 28) compared with CTAC implants. Conclusion. In using TMARS, more bone is removed, thus achieving more implant-bone apposition within the residual acetabular bone. In CTAC implants, the amount of bone removed is minimal, while the implant-bone apposition is more evenly distributed between the residual acetabulum and the outer cortex of the pelvis. The differences suggest that these implants used to treat pelvic discontinuity might achieve short- and long-term stability through different biomechanical mechanisms. Cite this article: Bone Joint J 2024;106-B(5 Supple B):74–81


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1021 - 1030
1 Sep 2024
Oto J Herranz R Fuertes M Plana E Verger P Baixauli F Amaya JV Medina P

Aims. Bacterial infection activates neutrophils to release neutrophil extracellular traps (NETs) in bacterial biofilms of periprosthetic joint infections (PJIs). The aim of this study was to evaluate the increase in NET activation and release (NETosis) and haemostasis markers in the plasma of patients with PJI, to evaluate whether such plasma induces the activation of neutrophils, to ascertain whether increased NETosis is also mediated by reduced DNaseI activity, to explore novel therapeutic interventions for NETosis in PJI in vitro, and to evaluate the potential diagnostic use of these markers. Methods. We prospectively recruited 107 patients in the preoperative period of prosthetic surgery, 71 with a suspicion of PJI and 36 who underwent arthroplasty for non-septic indications as controls, and obtained citrated plasma. PJI was confirmed in 50 patients. We measured NET markers, inflammation markers, DNaseI activity, haemostatic markers, and the thrombin generation test (TGT). We analyzed the ability of plasma from confirmed PJI and controls to induce NETosis and to degrade in vitro-generated NETs, and explored the therapeutic restoration of the impairment to degrade NETs of PJI plasma with recombinant human DNaseI. Finally, we assessed the contribution of these markers to the diagnosis of PJI. Results. Patients with confirmed PJI had significantly increased levels of NET markers (cfDNA (p < 0.001), calprotectin (p < 0.001), and neutrophil elastase (p = 0.022)) and inflammation markers (IL-6; p < 0.001) in plasma. Moreover, the plasma of patients with PJI induced significantly more neutrophil activation than the plasma of the controls (p < 0.001) independently of tumour necrosis factor alpha. Patients with PJI also had a reduced DNaseI activity in plasma (p < 0.001), leading to a significantly impaired degradation of NETs (p < 0.001). This could be therapeutically restored with recombinant human DNaseI to the level in the controls. We developed a model to improve the diagnosis of PJI with cfDNA, calprotectin, and the start tail of TGT as predictors, though cfDNA alone achieved a good prediction and is simpler to measure. Conclusion. We confirmed that patients with PJI have an increased level of NETosis in plasma. Their plasma both induced NET release and had an impaired ability to degrade NETs mediated by a reduced DNaseI activity. This can be therapeutically restored in vitro with the approved Dornase alfa, Pulmozyme, which may allow novel methods of treatment. A combination of NETs and haemostatic biomarkers could improve the diagnosis of PJI, especially those patients in whom this diagnosis is uncertain. Cite this article: Bone Joint J 2024;106-B(9):1021–1030


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 215 - 219
1 Feb 2023
Buchan SJ Lindisfarne EA Stabler A Barry M Gent ED Bennet S Aarvold A

Aims. Fixation techniques used in the treatment of slipped capital femoral epiphysis (SCFE) that allow continued growth of the femoral neck, rather than inducing epiphyseal fusion in situ, have the advantage of allowing remodelling of the deformity. The aims of this study were threefold: to assess whether the Free-Gliding (FG) SCFE screw prevents further slip; to establish whether, in practice, it enables lengthening and gliding; and to determine whether the age of the patient influences the extent of glide. Methods. All patients with SCFE who underwent fixation using FG SCFE screws after its introduction at our institution, with minimum three years’ follow-up, were reviewed retrospectively as part of ongoing governance. All pre- and postoperative radiographs were evaluated. The demographics of the patients, the grade of slip, the extent of lengthening of the barrel of the screw and the restoration of Klein’s line were recorded. Subanalysis was performed according to sex and age. Results. A total of 19 hips in 13 patients were included. The mean age of the patients at the time of surgery was 11.5 years (9 to 13) and the mean follow-up was 63 months (45 to 83). A total of 13 FG SCFE screws were used for the fixation of mild or moderate SCFE, with six contralateral prophylactic fixations. No hip with SCFE showed a further slip after fixation and there were no complications. Lengthening occurred in 15 hips (79%), with a mean lengthening of the barrel of 6.8 mm (2.5 to 13.6) at final follow-up. Remodelling occurred in all hips with lengthening of the barrel. There was statistically more lengthening in patients who were aged < 12 years, regardless of sex (p = 0.002). Conclusion. The FG SCFE screw is effective in preventing further slip in patients with SCFE. Lengthening of the barrel occurred in most hips, and thus allowed remodelling. This was most marked in younger children, regardless of sex. Based on this study, this device should be considered for use in patients with SCFE aged < 12 years instead of standard pinning in situ. Cite this article: Bone Joint J 2023;105-B(2):215–219