There is no consensus regarding optimum timing and frequency of ultrasound (US) for monitoring response to Pavlik harness (PH) treatment in developmental dysplasia of the hip (DDH). The purpose of our study was to determine if a limited-frequency hip US assessment had an adverse effect on treatment outcomes compared to traditional comprehensive US monitoring. This study was a single-centre noninferiority randomized controlled trial. Infants aged under six months whose hips were reduced and centred in the harness at initiation of treatment (stable dysplastic or subluxable), or initially decentred (subluxated or dislocated) but reduced and centred within four weeks of PH treatment, were randomized to our current standard US monitoring protocol (every clinic visit) or to a limited-frequency US protocol (US only at end of treatment). Groups were compared based on α angle and femoral head coverage at the end of PH treatment, acetabular indices, and International Hip Dysplasia Institute (IHDI) grade on one-year follow-up radiographs.Aims
Methods
Literature surrounding artificial intelligence (AI)-related applications for hip and knee arthroplasty has proliferated. However, meaningful advances that fundamentally transform the practice and delivery of joint arthroplasty are yet to be realized, despite the broad range of applications as we continue to search for meaningful and appropriate use of AI. AI literature in hip and knee arthroplasty between 2018 and 2021 regarding image-based analyses, value-based care, remote patient monitoring, and augmented reality was reviewed. Concerns surrounding meaningful use and appropriate methodological approaches of AI in joint arthroplasty research are summarized. Of the 233 AI-related orthopaedics articles published, 178 (76%) constituted original research, while the rest consisted of editorials or reviews. A total of 52% of original AI-related research concerns hip and knee arthroplasty (n = 92), and a narrative review is described. Three studies were externally validated. Pitfalls surrounding present-day research include conflating vernacular (“AI/machine learning”), repackaging limited registry data, prematurely releasing internally validated prediction models, appraising model architecture instead of inputted data, withholding code, and evaluating studies using antiquated regression-based guidelines. While AI has been applied to a variety of hip and knee arthroplasty applications with limited clinical impact, the future remains promising if the question is meaningful, the methodology is rigorous and transparent, the data are rich, and the model is externally validated. Simple checkpoints for meaningful AI adoption include ensuring applications focus on: administrative support over clinical evaluation and management; necessity of the advanced model; and the novelty of the question being answered. Cite this article:
Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture. Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The observers were asked to determine the presence of a scaphoid or other fracture and to classify the scaphoid fracture based on the Herbert classification system. Fleiss kappa statistics were used to calculate the interobserver agreement for the diagnosis of a fracture. Intraclass correlation coefficients (ICCs) were used to assess the agreement for the classification of scaphoid fracture.Aims
Methods
Morphological abnormalities are present in patients with developmental dysplasia of the hip (DDH). We studied and compared the pelvic anatomy and morphology between the affected hemipelvis with the unaffected side in patients with unilateral Crowe type IV DDH using 3D imaging and analysis. A total of 20 patients with unilateral Crowe-IV DDH were included in the study. The contralateral side was considered normal in all patients. A coordinate system based on the sacral base (SB) in a reconstructed pelvic model was established. The pelvic orientations (tilt, rotation, and obliquity) of the affected side were assessed by establishing a virtual anterior pelvic plane (APP). The bilateral coordinates of the anterior superior iliac spine (ASIS) and the centres of hip rotation were established, and parameters concerning size and volume were compared for both sides of the pelvis.Aims
Methods
Early cases of cauda equina syndrome (CES) often present with nonspecific symptoms and signs, and it is recommended that patients undergo emergency MRI regardless of the time since presentation. This creates substantial pressure on resources, with many scans performed to rule out cauda equina rather than confirm it. We propose that compression of the cauda equina should be apparent with a limited sequence (LS) scan that takes significantly less time to perform. In all, 188 patients with suspected CES underwent a LS lumbosacral MRI between the beginning of September 2017 and the end of July 2018. These images were read by a consultant musculoskeletal radiologist. All images took place on a 3T or 1.5T MRI scanner at Stoke Mandeville Hospital, Aylesbury, UK, and Royal Berkshire Hospital, Reading, UK.Aims
Methods
Although knee osteoarthritis (OA) is diagnosed and monitored radiologically, actual full-thickness cartilage loss (FTCL) has rarely been correlated with radiological classification. This study aims to analyze which classification system correlates best with FTCL and to assess their reliability. A prospective study of 300 consecutive patients undergoing unilateral total knee arthroplasty (TKA) for OA (mean age 69 years (44 to 91; standard deviation (SD) 9.5), 178 (59%) female). Two blinded examiners independently graded preoperative radiographs using five common systems: Kellgren-Lawrence (KL); International Knee Documentation Committee (IKDC); Fairbank; Brandt; and Ahlbäck. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC). Intraoperatively, anterior cruciate ligament (ACL) status and the presence of FTCL in 16 regions of interest were recorded. Radiological classification and FTCL were correlated using the Spearman correlation coefficient.Aims
Methods
In order to determine whether and for whom serial radiological evaluation is necessary in one-part proximal humerus fractures, we set out to describe the clinical history and predictors of secondary displacement in patients sustaining these injuries. Between January 2014 and April 2016, all patients with an isolated, nonoperatively treated one-part proximal humerus fracture were prospectively followed up. Clinical and radiological evaluation took place at less than two, six, 12, and 52 weeks. Fracture configuration, bone quality, and comminution were determined on the initial radiographs. Fracture healing, secondary displacement, and treatment changes were recorded during follow-up.Aims
Patients and Methods
Treatment for osteoarthritis (OA) has traditionally
focused on joint replacement for end-stage disease. An increasing number
of surgical and pharmaceutical strategies for disease prevention
have now been proposed. However, these require the ability to identify
OA at a stage when it is potentially reversible, and detect small
changes in cartilage structure and function to enable treatment
efficacy to be evaluated within an acceptable timeframe. This has
not been possible using conventional imaging techniques but recent
advances in musculoskeletal imaging have been significant. In this
review we discuss the role of different imaging modalities in the
diagnosis of the earliest changes of OA. The increasing number of
MRI sequences that are able to non-invasively detect biochemical
changes in cartilage that precede structural damage may offer a
great advance in the diagnosis and treatment of this debilitating
condition. Cite this article:
The femoral head receives its blood supply primarily
from the medial femoral circumflex artery, with its deep branch being
the most important. In a previous study, we performed classical anatomical dissections
of 16 hips. We have extended our investigation with a radiological
study, in which we aimed to visualise the arteries supplying the
femoral head in healthy individuals. We analysed 55 CT angiographic
images of the hip. Using 64-row CT angiography, we identified three main arteries
supplying the femoral head: the deep branch of the medial femoral
circumflex artery and the posterior inferior nutrient artery originating
from the medial femoral circumflex artery, and the piriformis branch
of the inferior gluteal artery. CT angiography is a good method
for visualisation of the arteries supplying the femoral head. The
current radiological studies will provide information for further
investigation of vascularity after traumatic dislocation of the
hip, using CT angiography.
The radiological and MRI appearances of 24 knees with patellar tendonitis resistant to conservative therapy were analysed to identify the characteristic MRI appearance and to determine if the patellar morphology was abnormal. A significant thickening of the tendon was found in all cases; this was a more reliable diagnostic feature than a high signal within the superior posterior and central aspect of the tendon at its proximal attachment The site of the lesion shown by MRI is more compatible with impingement of the inferior pole of the patella against the patellar tendon than a stress overload of the tendon. There were no significant differences in the length of the patella, inferior pole or length of the articular surface when the patellar morphology was compared with that of a matched control group.
The cam-type deformity in femoroacetabular impingement
is a 3D deformity. Single measurements using radiographs, CT or
MRI may not provide a true estimate of the magnitude of the deformity.
We performed an analysis of the size and location of measurements
of the alpha angle (α°) using a CT technique which could be applied
to the 3D reconstructions of the hip. Analysis was undertaken in
42 patients (57 hips; 24 men and 18 women; mean age 38 years (16
to 58)) who had symptoms of femoroacetabular impingement related
to a cam-type abnormality. An α° of >
50° was considered a significant
indicator of cam-type impingement. Measurements of the α° were made
at different points around the femoral head/neck junction at intervals
of 30°: starting at the nine o’clock (posterior), ten, eleven and
twelve o’clock (superior), one, two and ending at three o’clock
(anterior) position. The mean maximum increased α° was 64.6° (50.8° to 86°). The two
o’clock position was the most common point to find an increased α°
(53 hips; 93%), followed by one o’clock (48 hips; 84%). The largest α°
for each hip was found most frequently at the two o’clock position
(46%), followed by the one o’clock position (39%). Generally, raised α angles
extend over three segments of the clock face. Single measurements of the α°, whether pre- or post-operative,
should be viewed with caution as they may not be representative
of the true size of the deformity and not define whether adequate
correction has been achieved following surgery. Cite this article:
We describe the routine imaging practices of
Level 1 trauma centres for patients with severe pelvic ring fractures, and
the interobserver reliability of the classification systems of these
fractures using plain radiographs and three-dimensional (3D) CT
reconstructions. Clinical and imaging data for 187 adult patients
(139 men and 48 women, mean age 43 years (15 to 101)) with a severe
pelvic ring fracture managed at two Level 1 trauma centres between July
2007 and June 2010 were extracted. Three experienced orthopaedic
surgeons classified the plain radiographs and 3D CT reconstruction
images of 100 patients using the Tile/AO and Young–Burgess systems.
Reliability was compared using kappa statistics. A total of
115 patients (62%) had plain radiographs as well as two-dimensional
(2D) CT and 3D CT reconstructions, 52 patients (28%) had plain films
only, 12 (6.4%) had 2D and 3D CT reconstructions images only, and
eight patients (4.3%) had no available images. The plain radiograph
was limited to an anteroposterior pelvic view. Patients without
imaging, or only plain films, were more severely injured. A total
of 72 patients (39%) were imaged with a pelvic binder Interobserver reliability for the Tile/AO (Kappa 0.10 to 0.17)
and Young–Burgess (Kappa 0.09 to 0.21) was low, and insufficient
for clinical and research purposes. Severe pelvic ring fractures are difficult to classify due to
their complexity, the increasing use of early treatment such as
with pelvic binders, and the absence of imaging altogether in important
patient sub-groups, such as those who die early of their injuries. Cite this article: