Advertisement for orthosearch.org.uk
Results 1 - 20 of 39
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 278 - 288
1 Mar 1986
Roberts S Weightman B Urban J Chappell D

We studied the mechanical and biochemical properties of articular cartilage from 22 osteoarthritic femoral heads obtained at operation and 97 femoral heads obtained at autopsy. Cartilage from the zenith and from the antero-inferior aspect of each head was tested both in tension and in compression. Water content, swelling ability and proteoglycan content were measured, the cartilage was examined histologically and the density of the underlying bone was assessed. Fifty-five of the autopsy specimens were defined as macroscopically normal because they exhibited no progressive fibrillation patterns on staining with Indian ink; but significant changes in water content, bone density and tensile strength related to age were seen in this group. In 20 pairs of femoral heads which were both macroscopically normal, we found, surprisingly, that cartilage from the left and right sides of the same patient was sometimes very different. Compared with the normal autopsy specimens the osteoarthritic specimens had a significantly increased swelling ability, a lower proteoglycan content and impaired mechanical properties, being both weaker in tension and softer in compression. Abnormal autopsy specimens had values intermediate between those of osteoarthritic and normal groups. Results from this abnormal group suggest that there is no primary loss of proteoglycan in early osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 113 - 121
1 Jan 2012
Poultsides LA Gonzalez Della Valle A Memtsoudis SG Ma Y Roberts T Sharrock N Salvati E

We performed a meta-analysis of modern total joint replacement (TJR) to determine the post-operative mortality and the cause of death using different thromboprophylactic regimens as follows: 1) no routine chemothromboprophylaxis (NRC); 2) Potent anticoagulation (PA) (unfractionated or low-molecular-weight heparin, ximelagatran, fondaparinux or rivaroxaban); 3) Potent anticoagulation combined (PAC) with regional anaesthesia and/or pneumatic compression devices (PCDs); 4) Warfarin (W); 5) Warfarin combined (WAC) with regional anaesthesia and/or PCD; and 6) Multimodal (MM) prophylaxis, including regional anaesthesia, PCDs and aspirin in low-risk patients. Cause of death was classified as autopsy proven, clinically certain or unknown. Deaths were grouped into cardiopulmonary excluding pulmonary embolism (PE), PE, bleeding-related, gastrointestinal, central nervous system, and others (miscellaneous). Meta-analysis based on fixed effects or random effects models was used for pooling incidence data. In all, 70 studies were included (99 441 patients; 373 deaths). The mortality was lowest in the MM (0.2%) and WC (0.2%) groups. The most frequent cause of death was cardiopulmonary (47.9%), followed by PE (25.4%) and bleeding (8.9%). The proportion of deaths due to PE was not significantly affected by the thromboprophylaxis regimen (PA, 35.5%; PAC, 28%; MM, 23.2%; and NRC, 16.3%). Fatal bleeding was higher in groups relying on the use of anticoagulation (W, 33.8%; PA, 9.4%; PAC, 10.8%) but the differences were not statistically significant. Our study demonstrated that the routine use of PA does not reduce the overall mortality or the proportion of deaths due to PE


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 2 | Pages 245 - 248
1 May 1948
Taylor AR Blackwood W

1) A case is reported of paraplegia with normal radiographic appearances in which cervical cord damage was shown at autopsy to have been due to hyperextension injury. 2) The mechanism of such injuries is discussed, together with the differential diagnosis from acute prolapse of an intervertebral disc. 3) The grave dangers of using the fully extended position of the cervical spine in the management of these cases is noted


The Journal of Bone & Joint Surgery British Volume
Vol. 32-B, Issue 3 | Pages 376 - 383
1 Aug 1950
Strang C Rannie I

1. Maffucci's syndrome consists of dyschondroplasia (Ollier's disease) in association with cavernous haemangiomata and phlebectasia. Twenty-two cases have hitherto been described. 2. A further case is recorded with autopsy findings showing the characteristic features of the syndrome. Death was caused by a chondrosarcoma of the sphenoid, which led to subarachnoid haemorrhage, cranial nerve palsies, crossed hemiplegia and cavernous sinus thrombosis with almost total pituitary necrosis


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1062 - 1064
1 Sep 2004
DePalma MJ Slipman CW Siegelman E Bayruns TJ Bhargava A Frey ME Chin KR

We present a case of L2/3 interspinous bursitis treated with extraspinal injections. No previous investigations have used fluoroscopically guided spinal injections to confirm the clinical relevance of the MRI features of this type of bursae. Autopsy studies have revealed an increased incidence of interspinous lumbar bursal cavities with advancing age. Afflicted patients present with localised, midline lower lumbar pain exacerbated by extension. In young athletes these symptoms can mimic spondylolysis. MRI is useful in detecting soft-tissue injury of the posterior elements. Fluoroscopically guided diagnostic and therapeutic extraspinal injections can be used for confirmation and treatment of pain from such bursae


The Journal of Bone & Joint Surgery British Volume
Vol. 32-B, Issue 1 | Pages 42 - 47
1 Feb 1950
Fahrni WH

1. It is possible that neonatal sciatic palsy occurs more often than is suggested by perusal of the literature: paralysis of a foot may easily be overlooked in the new-born infant; it may be regarded as a temporary paresis due to mild birth trauma; or in later months it may be attributed to poliomyelitis. 2. Eleven cases of neonatal sciatic palsy are reported. Autopsy in one suggested that the paralysis was due to direct pressure on the sciatic nerve before birth. 3. A hypothesis is advanced by which to explain how pressure on the nerve trunk may arise in utero


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 543 - 547
1 Aug 1985
Lothe K Spycher M Ruttner

Human articular cartilage taken from 92 femoral heads at autopsy was examined macroscopically and microscopically. Fifty-two showed no changes except for occasional slight degeneration in the non-pressure areas; these changes were visible only microscopically. In the remaining 40 heads, different degrees of osteoarthrosis were seen; half the heads also showed focal lacunar resorptive lesions in the cartilage. The origin of this focal cartilage resorption is discussed and its possible association with necrosis, pannus formation and enzymatic synovial activities. We conclude that there is no evidence of a direct relationship between focal cartilage resorption and osteoarthrosis


The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 1 | Pages 418 - 433
1 Feb 1956
Sissons HA

1. The bone changes in four autopsied cases of Cushing's syndrome are described. The changes take the form of osteoporosis, which is most marked in the spine and the ribs. 2. The osteoporosis results from impaired osteoblastic bone formation in the presence of a normal degree of osteoclastic bone resorption. 3. Histological abnormalities of fracture callus in Cushing's syndrome indicate interference with the proliferation of osteoblasts and cartilage cells and with the formation of new tissue by these cells. 4. The bone changes in Cushing's syndrome are comparable with those produced in experimental animals by the administration of A.C.T.H. or cortisone


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 234 - 237
1 Mar 1987
Ferris B Dodds R Klenerman L Bitensky L Chayen J

Quantitative polarised light microscopy was applied to sections of unfixed, undecalcified bone taken at operation from patients with two types of proximal femoral fracture, subcapital and trochanteric. Specimens were also taken from the equivalent sites in otherwise normal subjects at autopsy, and from various other sites of traumatic fractures; these two latter groups acted as controls. Analysis of the 57 specimens disclosed changes in the nature of the bone at the site of subcapital fractures, namely the presence of relatively large crystals of hydroxyapatite and a change in the molecular orientation, but not total content, of the acidic proteoglycans of the bone matrix. Our results have confirmed and extended the findings of others on subcapital fractures, and have also shown very similar changes in the trochanteric fractures. It thus appears that the bony changes in the two types of proximal femoral fracture are not as different as has been suggested


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1123 - 1127
1 Nov 2003
Akizuki S Takizawa T Horiuchi H

Miller-Galante II total knee arthroplasty (MG II TKA) was performed on 32 knees in 30 patients. On both the femoral and tibial components, the fibre-metal area was plasma-sprayed with hydroxyapatite-tricalcium phosphate (HA-TCP). The clinical and radiographic outcome was evaluated. A mean pre-operative knee score of 26.0 ± 18.6 (SD) increased to 97.5 ± 3.5 and a mean pre-operative functional score of 21.7 ± 15.0 (SD) increased to 83.4 ± 12.4 at follow-up of seven years. Clear zones were common around the components at one month post-operatively but had completely disappeared after six months. An autopsy of a patient who underwent MG II TKA with HA-TCP two years previously, showed osteogenesis in all parts of the fibre-metal, and bone tissue comprised 77.7% of the interface. This coated prosthesis has good early fixation which is maintained at seven years with good clinical and radiographic outcomes


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 418 - 422
1 May 1986
Roberts S Weightman B Urban J Chappell D

Articular cartilage from the femoral heads of 27 patients having an arthroplasty for subcapital fracture was studied, and its mechanical and chemical properties compared to those of a group of 33 age-matched macroscopically normal autopsy specimens. Water and proteoglycan contents were measured, as were swelling ability, compressive and tensile strength of the cartilage, and the density of the underlying bone. Cartilage from the fracture specimens had a significantly reduced proteoglycan content, as measured by fixed charge density, and increased swelling ability. These results indicate that this group differs from the "normal" population and care should be taken before they are accepted as control material for studies on osteoarthritic cartilage. Another finding was that bone density was much the same in the fracture and the normal group. This casts some doubt upon the concept that patients who sustain subcapital fractures are more osteoporotic than the average for the same age range


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 3 | Pages 353 - 359
1 Aug 1975
Galasko CSB

Skeletal scintigraphy, which has now been established as a useful and accurate method of detecting early skeletal metastases and assessing their response to treatment, has been investigated for its pathological basis. Histological examination of several hundred necropsy specimens, from sixty-eight patients who died from malignant disease, showed a significant increase of osteoid and immature woven bone in the presence of metastatic cancer. Tumour-cell suspensions of the VX2 carcinoma were injected into the medullary cavity or on to the periosteal surface of the ilia or tibiae of New Zealand white rabbits. A combination of bone destruction and new bone formation, similar to the autopsy material, was seen. There were at least two mechanisms for the new bone production. Initially, intramembranous ossification was seen in the fibrous stroma surrounding the tumour. Once the cortex was involved and cortical bone destruction had occurred, large amounts of woven bone resembling fracture callus were laid down. The new bone had a markedly increased avidity for boneseeking isotopes, indicating why skeletal scintigraphy was useful. A further twenty rabbits, in whose ilia the VX2 carcinoma was growing, were treated by local irradiation. When treatment was successful the tumour was destroyed, the production of new bone ceased, and the lesion lost its increased avidity for bone-seeking isotopes, indicating that skeletal scintigraphy could be used to assess the response of skeletal metastases to therapy


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 71 - 77
1 Jul 2020
Gonzalez Della Valle A Shanaghan KA Nguyen J Liu J Memtsoudis S Sharrock NE Salvati EA

Aims

We studied the safety and efficacy of multimodal thromboprophylaxis in patients with a history of venous thromboembolism (VTE) who undergo total hip arthroplasty (THA) within the first 120 postoperative days, and the mortality during the first year. Multimodal prophylaxis includes discontinuation of procoagulant medications, VTE risk stratification, regional anaesthesia, an intravenous bolus of unfractionated heparin prior to femoral preparation, rapid mobilization, the use of pneumatic compression devices, and chemoprophylaxis tailored to the patient’s risk of VTE.

Methods

Between 2004 to 2018, 257 patients with a proven history of VTE underwent 277 primary elective THA procedures by two surgeons at a single institution. The patients had a history of deep vein thrombosis (DVT) (186, 67%), pulmonary embolism (PE) (43, 15.5%), or both (48, 17.5%). Chemoprophylaxis included aspirin (38 patients), anticoagulation (215 patients), or a combination of aspirin and anticoagulation (24 patients). A total of 50 patients (18%) had a vena cava filter in situ at the time of surgery. Patients were followed for 120 days to record complications, and for one year to record mortality.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 129 - 137
1 Jun 2020
Knowlton CB Lundberg HJ Wimmer MA Jacobs JJ

Aims

A retrospective longitudinal study was conducted to compare directly volumetric wear of retrieved polyethylene inserts to predicted volumetric wear modelled from individual gait mechanics of total knee arthroplasty (TKA) patients.

Methods

In total, 11 retrieved polyethylene tibial inserts were matched with gait analysis testing performed on those patients. Volumetric wear on the articular surfaces was measured using a laser coordinate measure machine and autonomous reconstruction. Knee kinematics and kinetics from individual gait trials drove computational models to calculate medial and lateral tibiofemoral contact paths and forces. Sliding distance along the contact path, normal forces and implantation time were used as inputs to Archard’s equation of wear to predict volumetric wear from gait mechanics. Measured and modelled wear were compared for each component.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 257 - 264
1 Feb 2012
Raskob GE Gallus AS Pineo GF Chen D Ramirez L Wright RT Lassen MR

In order to compare the effect of oral apixaban (a factor Xa inhibitor) with subcutaneous enoxaparin on major venous thromboembolism and major and non-major clinically relevant bleeding after total knee and hip replacement, we conducted a pooled analysis of two previously reported double-blind randomised studies involving 8464 patients. One group received apixaban 2.5 mg twice daily (plus placebo injection) starting 12 to 24 hours after operation, and the other received enoxaparin subcutaneously once daily (and placebo tablets) starting 12 hours (± 3) pre-operatively. Each regimen was continued for 12 days (± 2) after knee and 35 days (± 3) after hip arthroplasty. All outcomes were centrally adjudicated. Major venous thromboembolism occurred in 23 of 3394 (0.7%) evaluable apixaban patients and in 51 of 3394 (1.5%) evaluable enoxaparin patients (risk difference, apixaban minus enoxaparin, -0.8% (95% confidence interval (CI) -1.2 to -0.3); two-sided p = 0.001 for superiority). Major bleeding occurred in 31 of 4174 (0.7%) apixaban patients and 32 of 4167 (0.8%) enoxaparin patients (risk difference -0.02% (95% CI -0.4 to 0.4)). Combined major and clinically relevant non-major bleeding occurred in 182 (4.4%) apixaban patients and 206 (4.9%) enoxaparin patients (risk difference -0.6% (95% CI -1.5 to 0.3)).

Apixaban 2.5 mg twice daily is more effective than enoxaparin 40 mg once daily without increased bleeding.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1420 - 1430
1 Nov 2017
Azboy I Barrack R Thomas AM Haddad FS Parvizi J

The number of arthroplasties being performed increases each year. Patients undergoing an arthroplasty are at risk of venous thromboembolism (VTE) and appropriate prophylaxis has been recommended. However, the optimal protocol and the best agent to minimise VTE under these circumstances are not known. Although many agents may be used, there is a difference in their efficacy and the risk of bleeding. Thus, the selection of a particular agent relies on the balance between the desire to minimise VTE and the attempt to reduce the risk of bleeding, with its undesirable, and occasionally fatal, consequences.

Acetylsalicylic acid (aspirin) is an agent for VTE prophylaxis following arthroplasty. Many studies have shown its efficacy in minimising VTE under these circumstances. It is inexpensive and well-tolerated, and its use does not require routine blood tests. It is also a ‘milder’ agent and unlikely to result in haematoma formation, which may increase both the risk of infection and the need for further surgery. Aspirin is also unlikely to result in persistent wound drainage, which has been shown to be associated with the use of agents such as low-molecular-weight heparin (LMWH) and other more aggressive agents.

The main objective of this review was to summarise the current evidence relating to the efficacy of aspirin as a VTE prophylaxis following arthroplasty, and to address some of the common questions about its use.

There is convincing evidence that, taking all factors into account, aspirin is an effective, inexpensive, and safe form of VTE following arthroplasty in patients without a major risk factor for VTE, such as previous VTE.

Cite this article: Bone Joint J 2017;99-B:1420–30.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 304 - 310
1 Feb 2010
Jia W Zhang C Wang J Feng Y Ai Z

Platelet-leucocyte gel (PLG), a new biotechnological blood product, has hitherto been used primarily to treat chronic ulcers and to promote soft-tissue and bone regeneration in a wide range of medical fields. In this study, the antimicrobial efficacy of PLG against Staphylococcus aureus (ATCC 25923) was investigated in a rabbit model of osteomyelitis. Autologous PLG was injected into the tibial canal after inoculation with Staph. aureus. The prophylactic efficacy of PLG was evaluated by microbiological, radiological and histological examination. Animal groups included a treatment group that received systemic cefazolin and a control group that received no treatment.

Treatment with PLG or cefazolin significantly reduced radiological and histological severity scores compared to the control group. This result was confirmed by a significant reduction in the infection rate and the number of viable bacteria. Although not comparable to cefazolin, PLG exhibited antimicrobial efficacy in vivo and therefore represents a novel strategy to prevent bone infection in humans.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 31 - 37
1 Jan 2013
Zywiel MG Brandt J Overgaard CB Cheung AC Turgeon TR Syed KA

Symptomatic cobalt toxicity from a failed total hip replacement is a rare but devastating complication. It has been reported following revision of fractured ceramic components, as well as in patients with failed metal-on-metal articulations. Potential clinical findings include fatigue, weakness, hypothyroidism, cardiomyopathy, polycythaemia, visual and hearing impairment, cognitive dysfunction, and neuropathy. We report a case of an otherwise healthy 46-year-old patient, who developed progressively worsening symptoms of cobalt toxicity beginning approximately six months following synovectomy and revision of a fractured ceramic-on-ceramic total hip replacement to a metal-on-polyethylene bearing. The whole blood cobalt levels peaked at 6521 µg/l. The patient died from cobalt-induced cardiomyopathy. Implant retrieval analysis confirmed a loss of 28.3 g mass of the cobalt–chromium femoral head as a result of severe abrasive wear by ceramic particles embedded in the revision polyethylene liner. Autopsy findings were consistent with heavy metal-induced cardiomyopathy.

We recommend using new ceramics at revision to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components.

Cite this article: Bone Joint J 2013;95-B:31–7.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 632 - 639
1 May 2017
Hamilton TW Pandit HG Maurer DG Ostlere SJ Jenkins C Mellon SJ Dodd CAF Murray DW

Aims

It is not clear whether anterior knee pain and osteoarthritis (OA) of the patellofemoral joint (PFJ) are contraindications to medial unicompartmental knee arthroplasty (UKA). Our aim was to investigate the long-term outcome of a consecutive series of patients, some of whom had anterior knee pain and PFJ OA managed with UKA.

Patients and Methods

We assessed the ten-year functional outcomes and 15-year implant survival of 805 knees (677 patients) following medial mobile-bearing UKA. The intra-operative status of the PFJ was documented and, with the exception of bone loss with grooving to the lateral side, neither the clinical or radiological state of the PFJ nor the presence of anterior knee pain were considered a contraindication. The impact of radiographic findings and anterior knee pain was studied in a subgroup of 100 knees (91 patients).


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 585 - 588
1 May 2016
Bayley E Brown S Bhamber NS Howard PW

Aims

The place of thromboprophylaxis in arthroplasty surgery remains controversial, with a challenging requirement to balance prevention of potentially fatal venous thrombo-embolism with minimising wound-related complications leading to deep infection. We compared the incidence of fatal pulmonary embolism in patients undergoing elective primary total hip arthroplasty (THA) between those receiving aspirin, warfarin and low molecular weight heparin (LMWH) for the chemical component of a multi-modal thromboprophylaxis regime.

Patients and Methods

A prospective audit database was used to identify patients who had died within 42 and 90 days of surgery respectively between April 2000 and December 2012. A case note review was performed to ascertain the causes of death.