Aims. The primary aim of this study was to determine the morbidity
of a tibial strut
Aims. To compare the structural durability of hydroxyapatite-tricalcium
phosphate (HATCP) to autologous iliac crest bone graft in calcaneal
lengthening osteotomy (CLO) for pes planovalgus in childhood. Patients and Methods. We present the interim results of ten patients (HATCP, n = 6
and
The use of autograft bone is the best option
when undertaking a procedure that requires bone graft because it
is osteogenic, osteoconductive and osseo-inductive. Pain, morbidity
and complications associated with harvesting iliac or non-iliac
sites occur in between 6% and 30% of cases. An alternative source
of graft with possibly a lower morbidity is the intramedullary canal.
In this study, 28 patients undergoing 30 arthrodesis procedures
on the hindfoot had a mean of 48 cm3 (43 to 50) of bone
harvested locally from the hindfoot or the tibial shaft by antegrade or
retrograde reaming. No patient sustained a fracture of the calcaneum,
talus or tibia. There was no morbidity except for one complication
when the reamer breached the medial tibial cortex. This healed uneventfully. This method of using the reamer–irrigator–aspirator system is
an extension of the standard technique of intramedullary reaming
of the lower limb: it produces good-quality bone graft with viable
growth factors consistent with that of the iliac crest, and donor
site morbidity is low. This is an efficient method of obtaining
autologous bone for use in arthrodesis of the ankle or hindfoot.
Aims. Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA). Methods. A total of 14 patients who underwent a rTSA with an
Aims. The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results. Methods. This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata
Aims. We analyzed the long-term outcomes of patients observed over ten years after resection en bloc and reconstruction with extracorporeal irradiated
Aims. The use of frozen tumour-bearing
In this retrospective study we evaluated the
proficiency of shelf
Between 1996 and 2003, 16 patients (nine female, seven male) were treated for a primary bone sarcoma of the femur by wide local excision of the tumour, extracorporeal irradiation and re-implantation. An additional vascularised fibular graft was used in 13 patients (81%). All patients were free from disease when reviewed at a minimum of two years postoperatively (mean 49.7 months (24 to 96). There were no cases of infection. Primary union was achieved after a median of nine months (interquartile range 7 to 11). Five host-donor junctions (16%) united only after a second procedure. Primary union recurred faster at metaphyseal junctions (94% (15) at a median of 7.5 months (interquartile range 4 to 12)) than at diaphyseal junctions (75% (12) at a median of 11.1 months (interquartile range 5 to 18)). Post-operatively, the median Musculoskeletal Tumour Society score was 85% (interquartile range 75 to 96) and the median Toronto Extremity Salvage score 94% (interquartile range 82 to 99). The Mankin score gave a good or excellent result in 14 patients (88%). The range of movement of the knee was significantly worse when the extracorporeally irradiated
We have evaluated the use of a synthetic porous ceramic (Triosite) as a substitute for bone graft in posterior spinal fusion for idiopathic scoliosis. In a prospective, randomised study 341 patients at five hospitals in the UK and France were randomly allocated either to
Between 1983 and 1988 we carried out 45 Charnley low-friction arthroplasties with
In 1999, we developed a technique for biological
reconstruction after excision of a bone tumour, which involved using
autografts of the bone containing the tumour treated with liquid
nitrogen. We have previously reported the use of this technique
in 28 patients at a mean follow up of 27 months (10 to 54). In this study, we included 72 patients who underwent reconstruction
using this technique. A total of 33 patients died and three were
lost to follow-up, at a mean of 23 months (2 to 56) post-operatively,
leaving 36 patients available for a assessment at a mean of 101
months 16 to 163) post-operatively. The methods of reconstruction included
an osteo-articular graft in 16, an intercalary in 13 and, a composite
graft with prosthesis in seven. Post-operative function was excellent in 26 patients (72.2%),
good in seven (19.4%), and fair in three (8.3%) according to the
functional evaluation system of Enneking. No recurrent tumour occurred
within the grafts. The
The aim of this study was to assess a specific
protocol for the treatment of patients with a parosteal osteosarcoma of
the distal femur with limb salvage involving hemicortical resection
and reconstruction using recycled pasteurised
In this study a combination of autologous chondrocyte implantation (ACI) and the osteochondral
Surgical reconstruction of articular surfaces by transplantation of osteochondral
We describe a method of reconstruction using tumour-bearing
We have reviewed 54 patients who had undergone 61 total hip replacements using bulk femoral
Femoroacetabular impingement causes groin pain
and decreased athletic performance in active adults. This bony conflict
may result in femoroacetabular subluxation if of sufficient magnitude. The ligamentum teres has recently been reported to be capable
of withstanding tensile loads similar to that of the anterior cruciate
ligament, and patents with early subluxation of the hip may become
dependent on the secondary restraint that is potentially provided
by the ligamentum teres. Rupture of the ligamentum may thus cause
symptomatic hip instability during athletic activities. An arthroscopic reconstruction of the ligamentum teres using
iliotibial band
To evaluate the donor site morbidity and tendon morphology after harvesting whole length, full-thickness peroneus longus tendon (PLT) proximal to the lateral malleolus for ligament reconstructions or tendon transfer. A total of 21 eligible patients (mean age 34.0 years (standard deviation (SD) 11.2); mean follow-up period 31.8 months (SD 7.7), and 12 healthy controls (mean age, 26.8 years (SD 5.9) were included. For patients, clinical evaluation of the donor ankle was performed preoperatively and postoperatively. Square hop test, ankle strength assessment, and MRI of distal calf were assessed bilaterally in the final follow-up. The morphological symmetry of peroneal tendons bilaterally was evaluated by MRI in healthy controls.Aims
Methods
The upper three-quarters of the fibula is commonly used as a non-vascularised