Advertisement for orthosearch.org.uk
Results 1 - 18 of 18
Results per page:
Bone & Joint Research
Vol. 12, Issue 8 | Pages 504 - 511
23 Aug 2023
Wang C Liu S Chang C

Aims. This study aimed to establish the optimal fixation methods for calcaneal tuberosity avulsion fractures with different fragment thicknesses in a porcine model. Methods. A total of 36 porcine calcanea were sawed to create simple avulsion fractures with three different fragment thicknesses (5, 10, and 15 mm). They were randomly fixed with either two suture anchors or one headless screw. Load-to-failure and cyclic loading tension tests were performed for the biomechanical analysis. Results. This biomechanical study predicts that headless screw fixation is a better option if fragment thickness is over 15 mm in terms of the comparable peak failure load to suture anchor fixation (headless screw: 432.55 N (SD 62.25); suture anchor: 446.58 N (SD 84.97)), and less fracture fragment displacement after cyclic loading (headless screw: 3.94 N (SD 1.76); suture anchor: 8.68 N (SD 1.84)). Given that the fragment thickness is less than 10 mm, suture anchor fixation is a safer option. Conclusion. Fracture fragment thickness helps in making the decision of either using headless screw or suture anchor fixation in treating calcaneal tuberosity avulsion fracture, based on the regression models of our study. Cite this article: Bone Joint Res 2023;12(8):504–511


Bone & Joint 360
Vol. 2, Issue 1 | Pages 25 - 27
1 Feb 2013

The February 2013 Shoulder & Elbow Roundup. 360 . looks at: whether we should replace fractured shoulders; the limited evidence for shoulder fractures; cuffs and early physio; matrix proteins and cuff tears; long-term SLAP tear outcomes; suture anchors; recurrent Bankart repairs; and acromial morphology and calcific tendonitis


Bone & Joint Research
Vol. 5, Issue 6 | Pages 269 - 275
1 Jun 2016
Ono Y Woodmass JM Nelson AA Boorman RS Thornton GM Lo IKY

Objectives. This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Methods. Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’. Results. In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed ‘suture cutting through bone’ as the predominant source of suture displacement in cadaveric bone (qualitative) and greater ‘suture cutting through bone’ comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Conclusions. Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone. Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269–275. DOI: 10.1302/2046-3758.56.2000535


Bone & Joint 360
Vol. 1, Issue 5 | Pages 19 - 21
1 Oct 2012

The October 2012 Shoulder & Elbow Roundup. 360. looks at: fast-absorbing suture anchors for use in shoulder labral tears; double-row rotator cuff repair; degenerate massive rotator cuff tears addressed with partial repair; open and arthroscopic stabilisation of Bankart lesions; predicting the risk of revision humeral head replacement; arthroscopic treatment for frozen shoulder; and long-term follow-up of the Bristow-Latarjet procedure


Bone & Joint 360
Vol. 2, Issue 3 | Pages 27 - 29
1 Jun 2013

The June 2013 Shoulder & Elbow Roundup. 360 . looks at: whether suture anchors are still the gold standard; infection and revision elbow arthroplasty; the variable success of elbow replacements; sliding knots; neurologic cuff pain and the suprascapular nerve; lies, damn lies and statistics; osteoarthritis; and one- or two-stage treatment for the infected shoulder revision


Bone & Joint Research
Vol. 6, Issue 2 | Pages 82 - 89
1 Feb 2017
Nagra NS Zargar N Smith RDJ Carr AJ

Objectives. All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors. Materials and Methods. A total of four commercially available all-suture anchors, the ‘Y-Knot’ (ConMed), Q-FIX (Smith & Nephew), ICONIX (Stryker) and JuggerKnot (Zimmer Biomet) and a traditional anchor control TWINFIX Ultra PK Suture Anchor (Smith & Nephew) were tested in cadaveric human humeral head rotator cuff repair models (n = 24). This construct underwent cyclic loading applied by a mechanical testing rig (Zwick/Roell). Ultimate load to failure, gap formation at 50, 100, 150 and 200 cycles, and failure mechanism were recorded. Significance was set at p < 0.05. Results. Overall, mean maximum tensile strength values were significantly higher for the traditional anchor (181.0 N, standard error (. se). 17.6) compared with the all-suture anchors (mean 133.1 N . se. 16.7) (p = 0.04). The JuggerKnot anchor had greatest displacement at 50, 100 and 150 cycles, and at failure, reaching statistical significance over the control at 100 and 150 cycles (22.6 mm . se. 2.5 versus 12.5 mm . se. 0.3; and 29.6 mm . se. 4.8 versus 17.0 mm . se. 0.7). Every all-suture anchor tested showed substantial (> 5 mm) displacement between 50 and 100 cycles (6.2 to 14.3). All-suture anchors predominantly failed due to anchor pull-out (95% versus 25% of traditional anchors), whereas a higher proportion of traditional anchors failed secondary to suture breakage. Conclusion. We demonstrate decreased failure load, increased total displacement, and variable failure mechanisms in all-suture anchors, compared with traditional anchors designed for rotator cuff repair. These findings will aid the surgeon’s choice of implant, in the context of the clinical scenario. Cite this article: N. S. Nagra, N. Zargar, R. D. J. Smith, A. J. Carr. Mechanical properties of all-suture anchors for rotator cuff repair. Bone Joint Res 2017;6:82–89. DOI: 10.1302/2046-3758.62.BJR-2016-0225.R1


Bone & Joint Open
Vol. 3, Issue 10 | Pages 815 - 825
20 Oct 2022
Athanatos L Kulkarni K Tunnicliffe H Samaras M Singh HP Armstrong AL

Aims

There remains a lack of consensus regarding the management of chronic anterior sternoclavicular joint (SCJ) instability. This study aimed to assess whether a standardized treatment algorithm (incorporating physiotherapy and surgery and based on the presence of trauma) could successfully guide management and reduce the number needing surgery.

Methods

Patients with chronic anterior SCJ instability managed between April 2007 and April 2019 with a standardized treatment algorithm were divided into non-traumatic (offered physiotherapy) and traumatic (offered surgery) groups and evaluated at discharge. Subsequently, midterm outcomes were assessed via a postal questionnaire with a subjective SCJ stability score, Oxford Shoulder Instability Score (OSIS, adapted for the SCJ), and pain visual analogue scale (VAS), with analysis on an intention-to-treat basis.


Bone & Joint Open
Vol. 2, Issue 10 | Pages 871 - 878
20 Oct 2021
Taylor AJ Kay RD Tye EY Bryman JA Longjohn D Najibi S Runner RP

Aims

This study aimed to evaluate whether an enhanced recovery protocol (ERP) for arthroplasty established during the COVID-19 pandemic at a safety net hospital can be associated with a decrease in hospital length of stay (LOS) and an increase in same-day discharges (SDDs) without increasing acute adverse events.

Methods

A retrospective review of 124 consecutive primary arthroplasty procedures performed after resuming elective procedures on 11 May 2020 were compared to the previous 124 consecutive patients treated prior to 17 March 2020, at a single urban safety net hospital. Revision arthroplasty and patients with < 90-day follow-up were excluded. The primary outcome measures were hospital LOS and the number of SDDs. Secondary outcome measures included 90-day complications, 90-day readmissions, and 30day emergency department (ED) visits.


Bone & Joint Research
Vol. 9, Issue 6 | Pages 285 - 292
1 Jun 2020
Wang Z Li H Long Z Lin S Thoreson AR Moran SL Gingery A Amadio PC Steinmann SP Zhao C

Aims

Many biomechanical studies have shown that the weakest biomechanical point of a rotator cuff repair is the suture-tendon interface at the medial row. We developed a novel double rip-stop (DRS) technique to enhance the strength at the medial row for rotator cuff repair. The objective of this study was to evaluate the biomechanical properties of the DRS technique with the conventional suture-bridge (SB) technique and to evaluate the biomechanical performance of the DRS technique with medial row knots.

Methods

A total of 24 fresh-frozen porcine shoulders were used. The infraspinatus tendons were sharply dissected and randomly repaired by one of three techniques: SB repair (SB group), DRS repair (DRS group), and DRS with medial row knots repair (DRSK group). Specimens were tested to failure. In addition, 3 mm gap formation was measured and ultimate failure load, stiffness, and failure modes were recorded.


Bone & Joint Research
Vol. 9, Issue 4 | Pages 173 - 181
1 Apr 2020
Schon J Chahla J Paudel S Manandhar L Feltham T Huard J Philippon M Zhang Z

Aims

Femoroacetabular impingement (FAI) is a potential cause of hip osteoarthritis (OA). The purpose of this study was to investigate the expression profile of matrix metalloproteinases (MMPs) in the labral tissue with FAI pathology.

Methods

In this study, labral tissues were collected from four FAI patients arthroscopically and from three normal hips of deceased donors. Proteins extracted from the FAI and normal labrums were separately applied for MMP array to screen the expression of seven MMPs and three tissue inhibitors of metalloproteinases (TIMPs). The expression of individual MMPs and TIMPs was quantified by densitometry and compared between the FAI and normal labral groups. The expression of selected MMPs and TIMPs was validated and localized in the labrum with immunohistochemistry.


Bone & Joint 360
Vol. 8, Issue 3 | Pages 18 - 19
1 Jun 2019


Objectives

Bioresorbable orthopaedic devices with calcium phosphate (CaP) fillers are commercially available on the assumption that increased calcium (Ca) locally drives new bone formation, but the clinical benefits are unknown. Electron beam (EB) irradiation of polymer devices has been shown to enhance the release of Ca. The aims of this study were to: 1) establish the biological safety of EB surface-modified bioresorbable devices; 2) test the release kinetics of CaP from a polymer device; and 3) establish any subsequent beneficial effects on bone repair in vivo.

Methods

ActivaScrew Interference (Bioretec Ltd, Tampere, Finland) and poly(L-lactide-co-glycolide) (PLGA) orthopaedic screws containing 10 wt% β-tricalcium phosphate (β-TCP) underwent EB treatment. In vitro degradation over 36 weeks was investigated by recording mass loss, pH change, and Ca release. Implant performance was investigated in vivo over 36 weeks using a lapine femoral condyle model. Bone growth and osteoclast activity were assessed by histology and enzyme histochemistry.


Bone & Joint 360
Vol. 8, Issue 2 | Pages 2 - 8
1 Apr 2019
Shivji F Bryson D Nicolaou N Ali F


Bone & Joint 360
Vol. 3, Issue 6 | Pages 19 - 21
1 Dec 2014

The December 2014 Shoulder & Elbow Roundup360 looks at: cuff tears and plexus injury;

corticosteroids and physiotherapy in SAI; diabetes and elbow arthroplasty; distal biceps tendon repairs; shockwave therapy in frozen shoulder; hydrodilation and steroids for adhesive capsulitis; just what do our patients read?; and what happens to that stable radial head fracture?


Bone & Joint Research
Vol. 1, Issue 7 | Pages 131 - 144
1 Jul 2012
Papavasiliou AV Bardakos NV

Over recent years hip arthroscopic surgery has evolved into one of the most rapidly expanding fields in orthopaedic surgery. Complications are largely transient and incidences between 0.5% and 6.4% have been reported. However, major complications can and do occur. This article analyses the reported complications and makes recommendations based on the literature review and personal experience on how to minimise them.


Bone & Joint 360
Vol. 1, Issue 2 | Pages 25 - 27
1 Apr 2012

The April 2012 Trauma Roundup360 looks at fibula-pro-tibia plating, galeazzi fractures, distal radial fractures in the over 65s, transverse sacral fractures, acute dislocation of the knee, posterior malleolar fractures, immobilising the broken scaphoid, the terrible triad, lower limb amputation after trauma, and whiplash injuries


Bone & Joint 360
Vol. 1, Issue 3 | Pages 19 - 21
1 Jun 2012

The June 2012 Shoulder & Elbow Roundup360 looks at: reverse shoulder replacement; torn rotator cuffs and platelet-rich fibrin; rotator cuff repair; frozen shoulder; whether an arthroscopic rotator cuff repair actually heals; the torn rotator cuff’s effect on activities of daily living; subacromial impingement; how to improve the reliability of the Constant-Murley score; and failure of the Neer modification of an open Bankart procedure.


Bone & Joint Research
Vol. 1, Issue 9 | Pages 210 - 217
1 Sep 2012
Walton JR Murrell GAC

Objectives

The aim of this study was to determine whether there is any significant difference in temporal measurements of pain, function and rates of re-tear for arthroscopic rotator cuff repair (RCR) patients compared with those patients undergoing open RCR.

Methods

This study compared questionnaire- and clinical examination-based outcomes over two years or longer for two series of patients who met the inclusion criteria: 200 open RCR and 200 arthroscopic RCR patients. All surgery was performed by a single surgeon.